SCHEMATIC FEATURES AND TIPS


to date in order to access the latest features
of this schematic.

GET
Adobe Acrobat Reader

SAVE
a copy of this schematic

THE BOOKMARKS PANEL WILL ALLOW YOU TO THE FUNCTION ISOLATION TOOLS ISOLATE
QUICKLY NAVIGATE TO POINTS OF INTEREST. CIRCUITS FOR TRACING HYDRAULIC LINES

Function Isolation Tools

Grids On/Off

All Circuits Off


STANDARD VIEW
All Circuits On

021 (Orange) (Pilot Pump Output)

032 (Red) (Main Pump Output)

577 (Lt Green) (Drain/Return Line)

Machine Views

Machine View - Front

Machine View - Rear

Implement Stack 021 (Orange) (Pilot Output)


CIRCUIT ISOLATED
CLICK HERE TO VIEW THE SCHEMATIC
UTILIZE HYPERTEXT TO NAVIGATE TO COMPONENTS AND THEIR MACHINE LOCA- SYMBOLS AND DEFINITIONS PAGE
TION QUICKLY. HYPERTEXT IS INDICATED BY TEXT THAT IS BLUE AND UNDERLINED. ELECTRICAL SYMBOLS

Pressure Temperature Level


Switch Switch Switch Circuit Breaker

BASIC HYDRAULIC SYMBOLS

Fluid Pump Spring


Variability
Conditioner or Motor (Adjustable)

HOTKEYS (Keyboard Shortcuts)

FUNCTION KEYS
Zoom In “CTRL” / “+”
Zoom Out “CTRL” / “-”
Fit to Page “CTRL” / “0” (zero)
Hand Tool “SPACEBAR” (hold down)
Find “CTRL” / “F”
WHEN ONLY ONE CALLOUT IS SHOWING ON A Search “CTRL” / “SHIFT” / “F”

MACHINE VIEW, CLICKING ON THIS BUTTON WILL


VIEW ALL CALLOUTS MAKE ALL OF THE CALLOUTS VISIBLE. THIS
Due to different monitor sizes and PDF reader
preferences there may be some variance in linked
BUTTON IS TYPICALLY LOCATED IN THE TOP RIGHT schematic locations. This document is best viewed at
CORNER OF EVERY MACHINE VIEW PAGE. a screen resolution of 1024 X 768.

© 2021 Caterpillar. All Rights Reserved. CAT, CATERPILLAR, LET’S DO THE


WORK, their respective logos, “Caterpillar Corporate Yellow”, the “Power Edge”
and Cat “Modern Hex” trade dress as well as corporate and product identity used
herein, are trademarks of Caterpillar and may not be used without permission.
SCHEMATIC SYMBOLS AND DEFINITIONS
VALVES INTERNAL PASSAGEWAYS PUMPS BASIC HYDRAULIC
ENVELOPES FLOW IN ONE
DIRECTION
FLOW ALLOWED IN
EITHER DIRECTION
PARALLEL
FLOW
CROSS
FLOW
FIXED DISPLACEMENT
COMPONENT SYMBOLS

One Position Two Position Three Position Unidirectional Bidirectional Pump


Infinite Two Three Variability
Positioning Position Position or Motor
PORTS VARIABLE DISPLACEMENT
NON- COMPENSATED

CYLINDERS Fluid Spring


(Adjustable)
Two-way Three-Way Four-Way Conditioner
Unidirectional Bidirectional
CONTROL
AB AB
Single Acting Double Acting
MOTORS Pressure
FIXED DISPLACEMENT Spring
P T P T Compensation
Normal Position Shifted Position Infinite Position

CHECK
Control
ACCUMULATORS Unidirectional Bidirectional
Valves
Line Restriction
(Variable)
VARIABLE DISPLACEMENT
Basic Spring Shuttle NON- COMPENSATED
Pilot
Symbol Loaded Line Restriction
Controlled Spring Loaded Gas Charged Restriction
(Fixed)

Unidirectional Bidirectional

PILOT CONTROL Line Restriction


MAIN AUX.

2-Section
RELEASED PRESSURE Variable and Pressure
ROTATING SHAFTS Compensated
Pump

External Return Internal Return Unidirectional Bidirectional


REMOTE SUPPLY PRESSURE Attachment Pump: Variable and
Pressure Compensated

Internal
Simplified Complete Supply Pressure Hydraulic Pneumatic
Energy Triangles

COMBINATION CONTROLS
LINES MEASUREMENT

Solenoid Solenoid Solenoid Solenoid and Servo Thermal Detent Crossing Joining
or Manual and Pilot Pilot or Manual Pressure Temperature Flow

MANUAL CONTROL FLUID STORAGE RESERVOIRS

Push-pull Lever Manual Shutoff General Manual Push Button Pedal Spring Vented Pressurized Return Above Fluid Level Return Below Fluid Level

HYDRAULIC SYMBOLS - ELECTRICAL ELECTRICAL SYMBOLS


G
M T

Pressure Temperature Level Flow


Transducer Transducer Generator Electric Pressure Pressure Switch Temperature Electrical
Switch Switch Switch Switch Circuit Breaker
(Fluid) (Gas / Air) Motor Switch (Adjustable) Switch Wire

BASIC ELECTRICAL COMPONENT SYMBOLS HARNESS AND WIRE SYMBOLS


Wire, Cable, or Harness Assembly Identification:
Fuse: A component in an electrical circuit that will open the circuit if too much current flows through it. Includes Harness Identification Letters and Harness
Connector Serialization Codes (see sample).
Switch (Normally Open): A switch that will close at a specified point (temp, press, etc.). The circle indicates
that the component has screw terminals and a wire can be disconnected from it.
AG-C4 L-C12
Switch (Normally Closed): A switch that will open at a specified point (temp, press, etc.). 111-7898 3E-5179
No circle indicates that the wire cannot be disconnected from the component. Part Number: for 1
Connector Plug
Ground (Wired): This indicates that the component is connected to a grounded wire. 2
The grounded wire is fastened to the machine.
Plug Receptacle
Pin or Socket Number
Ground (Case): This indicates that the component does not have a wire connected to ground.
It is grounded by being fastened to the machine. Harness Identification Letter(s): (A, B, C, AA, AB, AC, ...)
Harness Connector Serialization Code: The "C" stands for
"Connector" and the number indicates which connector in the
Reed Switch: A switch whose contacts are controlled by a magnet. A magnet closes the contacts of
harness (C1, C2, C3, ...)
a normally open reed switch; it opens the contacts of a normally closed reed switch.
L-C12
3E-5179
Sender: A component that is used with a temperature or pressure gauge.
The sender measures the temperature or pressure. 5A
T Its resistance changes to give an indication to the gauge of the temperature or pressure. Component
Fuse (5 Amps) 9X-1123 Part Number
Relay (Magnetic Switch): A relay is an electrical component that is activated by electricity. 325-AG135 PK-14
It has a coil that makes an electromagnet when current flows through it. Harness identification code:
This example indicates wire group 325, Wire Gauge*
The electromagnet can open or close the switch part of the relay. wire 135 in harness "AG". Wire Color
*Wire gauge is shown in AWG (American Wire Gauge)
Solenoid: A solenoid is an electrical component that is activated by electricity. but could also be shown in metric denoted with mm
It has a coil that makes an electromagnet when current flows through it.
The electromagnet can open or close a valve or move a piece of metal that can do work. 1 Deutsch connector: Typical representation
of a Deutsch connector. The plug contains all
2 sockets and the receptacle contains all pins.
Magnetic Latch Solenoid: An electrical component that is activated by electricity and held latched by a
permanent magnet. It has two coils (latch and unlatch) that make electromagnet 1 Sure-Seal connector: Typical representation
when current flows through them. It also has an internal switch that places of a Sure-Seal connector. The plug and receptacle
2 contain both pins and sockets.
the latch coil circuit open at the time the coil latches.

© 2021 Caterpillar. All Rights Reserved. CAT, CATERPILLAR, LET’S DO THE


WORK, their respective logos, “Caterpillar Corporate Yellow”, the “Power Edge”
and Cat “Modern Hex” trade dress as well as corporate and product identity used
herein, are trademarks of Caterpillar and may not be used without permission.
M0095369-05
October 2021

320, 320 GC, 323, and 323 GC Excavator


Hydraulic System
FJM1-20000 YBP1-UP
YTF1-10000 ZBN1-40000
RGJ1-UP BR4215-40000
KHJ1-10000 ZBT1-UP
KTN449-UP DKJ2165-40000
XBJ231-UP LKS1-20000
HEX2106-UP JGY1-20000
YCP1-UP MYK1-20000
RAZ996-UP KFE1-20000
HDT1-UP NDL1-20000
BR91-40000 LTN1-20000
KTY1-40000 DWF133-40000
YBL1-40000 KPE1-20000
BR61-40000
XAR1-20000
DYT1-20000

Volume 1 of 2: Standard
Volume 2 of 2: Attachment

PUBLICATIONS.CAT.COM
© 2021 Caterpillar. All Rights Reserved. CAT, CATERPILLAR, LET’S DO THE WORK, their respective logos, “Caterpillar Corporate Yellow”, the “Power Edge”
and Cat “Modern Hex” trade dress as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission.
COMPONENT LOCATION
VOLUME 1 - STANDARD
Schematic Machine
Component
Location Location
Accumulator Gp - Hydraulic (Uncharged) H-9 1
Cylinder Gp - Boom J-9 2
Cylinder Gp - Bucket J-5 3
Cylinder Gp - Stick J-11 4
Filter Gp - Case Drain A-7 5
Filter Gp - Hydraulic Return A-8 6
Motor Gp - Swing C-9 7
Motor Gp - Travel (LH) C-13, H-14 8
Motor Gp - Travel (RH)
M C-11, H-11 9
Pump Gp - Main Hydraulics C-4 10
Sensor Gp - Pressure (Boom Cylinder Head End) I-9 11
Sensor Gp - Pressure (Bucket Cylinder Head End) I-4 12
Sensor Gp - Pressure (Bucket Cylinder Rod End) D-5 13
Sensor Gp - Pressure (Stick Cylinder Head End) H-7 14
Sensor Gp - Pressure (Stick Cylinder Rod End) D-10 15
Sensor Gp - Pressure (Pump 1) D-6 16
Sensor Gp - Pressure (Pump 2) D-7 17
Swivel Gp A-12 18
Valve Gp - Check (Return) I-11 19
Valve Gp - Fine Swing A-9 20
Valve Gp - Main Control H-4 21
Valve Gp - Solenoid (Heavy Lift) I-3 22
COMPONENT LOCATION
VOLUME 2 - ATTACHMENT
Schematic Machine
Component
Location Location
Cylinder Gp - Boom G-3 23
Cylinder Gp - Quick Coupler E-8 24
Cylinder Gp - Smart Boom J-4 25
Cylinder Gp - Stick D-4 26
Cylinder Gp - VA-Boom D-11 27
Filter Gp - Manual Relief (W/ Hammer Return) J-14 28
Filter Gp - Electric Relief (W/ Hammer Return) I-12 29
Filter Gp - One Way/ One Pump (W/ Hammer Return) F-11 30
Manifold Gp - Solenoid (Medium Circuit) G-8 31
Pump Gp - Auxiliary G-6 32
Sensor Gp - Pressure (Boom Cylinder Head End (BLCV) E-2 34
Sensor Gp - Pressure (Boom Cylinder Head End) (Smart Boom) H-5 35
Sensor Gp - Pressure (Boom Cylinder Rod End) (BLCV) E-3 36
Sensor Gp - Pressure (Boom Cylinder Rod End) (Smart Boom) H-4 33
Sensor Gp - Pressure (Hydraulic Pump Output #2) A-7 37
Sensor Gp - Squeeze Head End Pressure (Electric Relief) J-10 38
Sensor Gp - Squeeze Head End Pressure (Manual Relief) J-16 39
Sensor Gp - Squeeze Rod End Pressure (Electric Relief) I-10 40
Sensor Gp - Squeeze Rod End Pressure (Manual Relief) J-15 41
Valve As - Ball (Combined Function - Manual Relief) I-14 42
Valve Gp - Bank-2 (Medium Circuit) J-8 43
Valve Gp - Check-D (SLCV) C-4 44
Valve Gp - Check-D (VAB) C-11 45
Valve Gp - Check-D LH (BLCV) F-5 46
Valve Gp - Check-D LH (Smart Boom) J-5 47
Valve Gp - Check-D RH (Smart Boom) J-3 48
Valve Gp - Check-D RH (BLCV) G-2 49
Valve Gp - Check-E (Boom Float Up) H-5 50
Valve Gp - Check-E (Quick Coupler) A-7 51
Valve Gp - Main Control (Bank 4) F-11 52
Valve Gp - Main Control (Bank 5) H-10 53
Valve Gp - Main Control (Bank 6) (VAB) D-12 54
Valve Gp - Main Control (Smart Boom) I-2 55
Valve Gp - Shuttle-B (Smart Boom) J-2 56
Valve Gp - Solenoid (Auxiliary Hydraulic Boost Flow) C-7 57
Valve Gp - Solenoid (Boom Float Down) J-2 58
Valve Gp - Solenoid and Pressure Reducing (Quick Coupler) E-7 59
Valve Gp - Solenoid and Variable Relief #2 I-10 60
Valve Gp - Solenoid and Variable Relief #2 J-12 61
TAP LOCATION
VOLUME 1 - STANDARD

Tap Schematic
Description
Number Location
AA Pump 1 Pressure C-6
BB Pump 2 Pressure C-3
CC Case Drain Pressure A-4
DD Pilot Pressure E-11
TAP LOCATION
VOLUME 2 - ATTACHMENT

Tap Schematic
Description
Number Location
A1 Blade Lower Valve Pressure H-8
A2 Blade Raiser Valve Pressure H-9
T1 Stick Load Control Pressure D-3
T2 Variable Boom Control Pressure D-10
PP Medium Output Pressure H-6
14 13 12 11 10 9 8 7 6 5 4 3 2 1

(4) CYLINDER GP - STICK (2) CYLINDER GP - BOOM


490-4144 510-9212 (3) CYLINDER GP - BUCKET
490-4180
Dr Dr
M0095369-05 VOL 1 of 2

J J

BR2
(Dimensions: 48 inches x 35 inches)

(11) SENSOR GP - PRESSURE


(BOOM CYLINDER HEAD)
344-7392

Pi Pi

AL3 BL3 BR3 AR3 AR2


P2 P3 P3 P2 AUX MPV-T
RETURN NOTE J
I QC-T I
NOTE F (22) VALVE GP - SOLENOID
NOTE H HEAVY LIFT HPi
2 SPEED SWG (1) ACCUMULATOR GP (12) SENSOR GP - PRESSURE
CV-T TRAVEL PRKG BK (BUCKET CYLINDER HEAD END) 524-0912
HYDRAULIC (UNCHARGED) NOTE B
CONTROL CONTROL (14) SENSOR GP - PRESSURE 344-7392 BLCV-Pi
352-6860 A
D NOTE P
C (STICK CYLINDER HEAD END)
344-7392 NOTE R
B (LOWER) A (UPPER) A (LOWER) B (UPPER) AL3 AL2 AL1 HPi AR1 AR2 AR3
36 Page,

d P Pi5 SG Pi4 PAC


(8) MOTOR GP (9) MOTOR GP P T
A C
TRAVEL (LH) TRAVEL (RH) B 6 7 24
582-9758 582-9758 11 13 18 23 16 12
B D (19) VALVE GP 21 CV-Dr
H CHECK (RETURN) (21) VALVE GP - MAIN CONTROL H
AL1 BR1 STD: 516-8623
B' D' 490-3958
Dr1 HEAVY LIFT: 516-8625
BL1 AR1
A' C' BPi MU
d' P'
SWG-Dr (18) SWIVEL GP
490-3995
2 SPEED Dr2 Pi2 A AL3 AL2 AL1 SHS AR1 AR2 AR3 MU Pi3 Dr3
DRAIN
TRAVEL T <UP> <IN> <OUT> <L> <UP>
FILTER <BKWD> <BKWD> <CLOSE> BKHS <DOWN> <OUT>
CONTROL
Dr4
TRAVEL MOTOR FOR GC
G CV-Pi7 G

BOOM(1)
Pi6

BUCKET
TRAVEL(R)
NOTE R

STICK(2)
SWING
BOOM(2)

STR-TRAVEL
Pi7

TRAVEL(L)
STICK(1)
Dr6

F F

SWG PRI

STK UNL
Dr7

SRS <OUT> <IN> <R> <FWD> P2S P1S <FWD> BR1 <OPEN> BR2 BKRS <UP> <DOWN> BR3 <IN>
Pi1 BL3 BL2 BL1 P2 P1 Dr5 IDENT DEVICE NAME
1 SOLENOID - MAIN HYDRAULIC PUMP #1
2 SOLENOID - MAIN HYDRAULIC PUMP #2
5 SOLENOID - STICK UNLOAD
CV-Dr5 6 SOLENOID - TRAVEL SPEED
E DD NOTE R 7 SOLENOID - SWING BRAKE E
8 SOLENOID - SWING PRIORITY

P2 P1 9 SOLENOID - HYDRAULIC LOCK


10 SOLENOID - BOOM CYLINDER EXTEND
11 SOLENOID - PUMP TO BOOM HEAD END
8 5 12 SOLENOID - BOOM CYLINDER RETRACT
9 14 19 17
20 22 10 15 13 SOLENOID - STICK CYLINDER RETRACT
14 SOLENOID - STICK CYLINDER EXTEND
SPi bST 15 SOLENOID - PUMP TO STICK HEAD END
(15) SENSOR GP - PRESSURE 16 SOLENOID - BUCKET CYLINDER EXTEND
(STICK CYLINDER ROD END) BR3 17 SOLENOID - BUCKET CYLINDER RETRACT
344-7392 SLCV-Pi
18 SOLENOID - SWING LEFT
BL3 19 SOLENOID - SWING RIGHT
NOTE N BL2 BL1 bST BR1 BR2 (13) SENSOR GP 20 SOLENOID - LEFT TRAVEL FORWARD
21 SOLENOID - LEFT TRAVEL BACKWARD
PRESSURE (BUCKET
(17) SENSOR GP - PRESSURE (16) SENSOR GP - PRESSURE CYLINDER ROD END)
22 SOLENOID - RIGHT TRAVEL FORWARD
D 23 SOLENOID - RIGHT TRAVEL BACKWARD D
(PUMP 2) (PUMP 1) 344-7392 24 SOLENOID - STRAIGHT TRAVEL
344-7392 344-7392 25 SOLENOID - FINE SWING

(9) MOTOR GP
TRAVEL (RH)
(8) MOTOR GP 593-5123 (10) PUMP GP
TRAVEL (LH) SWG MAIN HYDRAULICS
593-5213 PRKG BK 320: 531-9885
CONTROL 323: 531-9886 NOTE B: FOR USE AS HEAVY LIFT
P1 P2 NOTE C: FOR USE AS FINE SWING
AA BB
NOTE F: FOR USE AS AUXILIARY RETURN LINE
NOTE H: FOR USE AS QUICK COUPLER
Pi Pi PG (7) MOTOR GP BLCV-Dr 1 2 NOTE J: FOR USE AS MEDIUM CIRCUIT
NOTE L: FOR USE AS VALUABLE BOOM LOWERING CHECK VALVE
C SWING NOTE P ADJ1 ADJ2 NOTE N: FOR USE AS STICK LOWERING CHECK VALVE
C
Dr1 Dr2 NOTE P: FOR USE AS BOOM LOWERING CHECK VALVE
SWG-Dr STD: 536-6580 NOTE R NOTE R: FOR USE AS SMART BOOM
DB MA1 A1 A2 MA2
Dr2 Dr1 GC: 489-3487
SLCV-Dr
NOTE N
MU HYDRAULIC CIRCUIT COLOR DESCRIPTIONS
M
PILOT CIRCUIT
PUMP 1 OUTPUT

PA PB HEAVY LIFT CONTROL CIRCUIT


TRAVEL LEFT CONTROL CIRCUIT

SMB-T VLCV-Dr SUPPLY LINE

G2 G1 G1 G2 NOTE L
STICK CONTROL CIRCUIT

Q MIN
Q MIN
SWING CONTROL CIRCUIT
NOTE R DRAIN / RETURN LINE
SWING BRAKE CIRCUIT
QC-Dr PUMP 2 OUTPUT

NOTE H
TRAVEL SPEED CONTROL CIRUIT
BUCKET CONTROL CIRCUIT
TRAVEL RIGHT CONTROL CIRCUIT
BOOM CONTROL CIRCUIT
B B
bST
LINE PATTERNS
P2 (LOWER) P1 (UPPER) d P P1 (LOWER) P2 (UPPER) DRAIN

Q MAX
Pressure Line

Q MAX
CV-Dr FILTER
A C Pilot / Load Sensing Pressure

Drain / Return Lines

B D CV-T T1 Air Line

Component Group
AL1 BR1
B' D' (5) FILTER GP MC1 S1 T2 MC2 CALLOUTS

BL1 AR1 CASE DRAIN YY Taps (Pressure, Sampling, Sensor - by letter)


A FA Dr FB B 491-6075
A' C' DL DL D Connectors (By letter)

d' P' Callout Number


(Machine Location from (52) VALVE GP - CONTROL
Component
Name

SWG-Dr
Component LocationsTable)
138-1234
(18) SWIVEL GP CC
Part Number

A 490-3995 25 A
THIS SCHEMATIC IS FOR THE 320, 320 GC, 323, AND 323 GC EXCAVATOR
2 SPEED
DRAIN HYDRAULIC SYSTEM
TRAVEL BL2 AL2
FILTER (20) VALVE GP
VOLUME 1 of 2: STANDARD
CONTROL (6) FILTER GP Do not operate or work on this product unless you have
read and understood the instruction and warnings in the MEDIA NUMBER: M0095369-05
FINE SWING HYDRAULIC RETURN relevant Operation and Maintenance Manuals and
relevant service literature. Failure to follow the instruc- SCHEMATIC PART NUMBER: 490-3960, CHANGE: 05, VERSION: HE
TRAVEL MOTOR FOR STD 493-3208 488-8581 tions or heed the warnings could result in injury or Components are shown installed on a fully operable machine with the key and engine off.

NOTE C
death. Proper care is your responsibility.
Refer to the appropriate Service Manual for Troubleshooting, Specifications and Systems Operations.
Refer to the Parts Manual using a specific serial number prefix in SIS before ordering parts from this schematic.

14 13 12 11 10 9 8 7 6 5 4 3 2 1
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

(25) CYLINDER GP - BOOM


527-5464
(43) VALVE GP - BANK-2
(MEDIUM CIRCUIT) (47) VALVE GP - CHECK-D LH
M0095369-05 VOL 2 of 2

310-0165 (BLCV) (48) VALVE GP - CHECK-D RH BLCV-Pi


J SINGLE SINGLE SINGLE (BLCV) NOTE N J
SINGLE 507-5967
NOTE M 507-5967
DOUBLE DOUBLE DOUBLE DOUBLE
T2 NOTE M (56) VALVE GP - SHUTTLE-B
(Dimensions: 56 inches x 35 inches)

(41) SENSOR GP - SQUEEZE ROD (38) SENSOR GP - SQUEEZE HEAD (SMART BOOM)
(39) SENSOR GP - SQUEEZE B
END PRESSURE END PRESSURE 164-6979 (58) VALVE GP - SOLENOID
HEAD END PRESSURE (61) VALVE GP - SOLENOID AND
338-6971 P1 338-6971 Pi Pi (BOOM FLOAT DOWN)
338-6971 VARIABLE RELIEF #1 B
(28) FILTER GP 545-9111 524-0911
(W/ HAMMER RETURN) (40) SENSOR GP - SQUEEZE ROD
545-9112 G
224-1687 END PRESSURE
<EXT> <RET>
NOTE G 338-6971 MP-Pa1 MP-Pb1
NOTE G R
X2 T
P1 X2 A1 CV-Dr5
NOTE R
Dr P
P2
G X1 A X1 A Dr
AUX
B A Pi
I RETURN R <RET> B1 I
NOTE F
(29) FILTER GP CV-Pi7
(W/ HAMMER RETURN) NOTE R
P2 (60) VALVE GP - SOLENOID AND
224-1687
NOTE G
VARIABLE RELIEF #2 <EXT> A1
(42) VALVE AS - BALL 545-9109 C T1
389-2407 (55) VALVE GP - CONTROL
AUX 545-9110 (SMART BOOM)
RETURN NOTE G 518-4461
AL5 AR5 BL5 BR5 AL5 AR5 BL5 BR5 AR3 T2
NOTE F
P
42 Page,

MPV-P Dr
(33) SENSOR GP - PRESS
COMBINED FUNCTION - MANUAL RELIEF COMBINED FUNCTION - ELECTRIC RELIEF PLS (BOOM CYLINDER
MPV-T T1 PPS (35) SENSOR GP - PRESSURE ROD END)
DETAIL OF ADDITIONAL VALVE (2) AL5
ADDITIONAL VALVE (2)
AR5
ADDITIONAL VALVE (1) NOTE J PP (BOOM CYLINDER HEAD END) 338-6971
SMB-T
NOTE E AR5 NOTE E NOTE D 338-6971
B A
NOTE R
H AL5 H
MPV-P BR3
31 (53) VALVE GP - MAIN CONTROL Dr BLCV-Dr

COVER

COVER
AUX(2)

AUX(1)
33 A1 A2
MAIN CONTROL VALVE (BANK 5) NOTE N

END

END
MP-Pb1 MP-Pa1 (50) VALVE GP - CHECK-E
516-8624 FOR STD
516-8626 FOR HL A (BOOM FLOAT UP)
297-0370
<EXT> Pi3 A2 A1
<EXT> SMART BOOM ATTACHMENT
BL5 BR5 A2 B2 A1 B1
<RET> <EXT>
36 35 S
AUXILIARY(1)

Dr
AR5 (32) PUMP GP
AUXILIARY(2)

ADDITIONAL VALVE (1) P


G S1 AUXILIARY
G
NOTE D (23) CYLINDER GP - BOOM
493-3206
527-5464

T (49) VALVE GP - CHECK-D RH

COVER

COVER
AUX(1)
MAIN CONTROL VALVE (BLCV)

END

END
(31) MANIFOLD GP
507-5967
SOLENOID (MEDIUM CIRCUIT)
Dr2 Pi2 NOTE M
259-7430

BR5 (46) VALVE GP - CHECK-D LH


(BLCV) B

COVER
COVER
(52) VALVE GP - MAIN CONTROL (BANK 4) Pi
507-5967 B
564-5032 FOR HL Pi

END
MAIN CONTROL VALVE

END
564-5033 FOR STD NOTE M

(30) FILTER GP
<RET>
(W/ HAMMER RETURN)
F SINGLE SINGLE BLCV-Pi F
224-1687 X2 NOTE M
X2
NOTE G
<RET>
X1 A Dr
MEDIUM CIRCUIT ATTACHMENT X1 A Dr

AUX
RETURN
32
NOTE F (24) CYLINDER GP - QUICK COUPLER
34
AR5 569-8000 AR3
BR5
(34) SENSOR GP - PRESSURE
BL5 ONE-WAY/ ONE PUMP ATTACHMENT
DETAIL OF ADDITIONAL VALVE (1) (BOOM CYLINDER HEAD END)
338-6971
NOTE D BLCV-Dr
TCS ATTACHMENT NOTE P
E BR3
E

(36) SENSOR GP - PRESSURE


VLCV-Pi (BOOM CYLINDER ROD END)
(59) VALVE GP - SOL AND 338-6971
PRESSURE REDUCING
514-7723 FOR UQC (CW)
AL6 A B 549-7972 FOR HQC (CPG)
aL6 BLCV ATTACHMENT
81

(26) CYLINDER GP - STICK


D <EXT> (27) CYLINDER GP - VA-BOOM 516-5834 D
T2 61 62 T1

S1 S2
CYL B
A(P) B(T) Pi SLCV-Pi
AL6 Pi
VLCV-Pi VLCV-Pi NOTE N
AUXILIARY(3)

(54) VALVE GP - MAIN CONTROL (BANK 6) QC-T


490-3957 QC-P
NOTE H
aL6
AL3
COVER

COVER

AL6
AUX(3)

AUX(2)

AUX(1)

MAIN CONTROL VALVE


END

END

C C
A (57) VALVE GP - SOLENOID
(AUXILIARY HYDRAULIC BOOST FLOW)
524-0912 A Dr
(45) VALVE GP - CHECK-D (44) VALVE GP - CHECK-D
ADDITIONAL VALVE (3) (VAB) BL3
CV Dr Dr (SLCV) SLCV-Dr
BL6 NOTE K 508-9741 P QC-Dr 5089741 NOTE N
BL6 NOTE H
VLCV-Dr
<RET> NOTE L LINE PATTERNS
Pressure Line

Pi2 Pilot / Load Sensing Pressure

Drain / Return Lines

COVER
Air Line

COVER
B MAIN CONTROL VALVE B
SLCV ATTACHMENT

END
Component Group

END
CALLOUTS
YY Taps (Pressure, Sampling, Sensor - by letter)

82 bST P2S
IDENT DEVICE NAME DL DL D Connectors (By letter)
ATTACHMENT VALVE#1 EXTEND
31 Callout Number Component
PRESSURE SOLENOID (Machine Location from (52) VALVE GP - CONTROL Name

QC-P ATTACHMENT VALVE#1 RETRACT


Component LocationsTable)
138-1234 Part Number

32
BL6 PRESSURE SOLENOID
(51) VALVE GP - CHECK-E 33
ATTACHMENT VALVE#2 EXTEND
(QUICK COUPLER) PRESSURE SOLENOID

DETAIL OF ADDITIONAL VALVE (3) 123-4750 34


ATTACHMENT VALVE#2 RETRACT
PRESSURE SOLENOID
Do not operate or work on this product unless you have

NOTE K
read and understood the instruction and warnings in the
(37) SENSOR GP - PRESSURE ATTACHMENT VALVE#3 EXTEND
NOTE D: FOR DETAIL OF
ADDITIONAL VALVE (1) FOR TCS
relevant Operation and Maintenance Manuals and
relevant service literature. Failure to follow the instruc-
35
(HYDRAULIC PUMP OUTPUT #2) PRESSURE SOLENOID
NOTE E: FOR DETAIL OF tions or heed the warnings could result in injury or
HYDRAULIC CIRCUIT COLOR DESCRIPTIONS death. Proper care is your responsibility.
338-6971 ATTACHMENT VALVE#3 RETRACT
ADDITIONAL VALVE (2) FOR TCS
NOTE F: FOR USE AS AUXILIARY RETURN LINE
36 PILOT CIRCUIT

A PRESSURE SOLENOID NOTE G: FOR USE AS W/ HAMMER RETURN FILTER


NOTE H: FOR USE AS QUICK COUPLER
PUMP 1 OUTPUT
MEDIUM PRESSURE CONTROL CIRCUIT A
61 QUICK COUPLER SOLENOID #1 QUICK COUPLER CONTROL CIRCUIT THIS SCHEMATIC IS FOR THE 320, 320 GC, 323, AND 323 GC EXCAVATOR
NOTE J: FOR USE AS MEDIUM CIRCUIT

VAB ATTACHMENT QCPLR ATTACHMENT


VAB CONTROL CIRCUIT
62 QUICK COUPLER SOLENOID #2 NOTE K: FOR DETAIL OF ADDITIONAL VALVE (3) HYDRAULIC SYSTEM
SUPPLY LINE
VARIABLE ANGLE BOOM EXTEND FOR VALUABLE BOOM LOWERING CHECK VALVE AUXILIARY PUMP OUTPUT VOLUME 2 of 2: ATTACHMENT
81 NOTE L: FOR USE AS VALUABLE BOOM LOWERING CHECK VALVE STICK CONTROL CIRCUIT
PRESSURE SOLENOID NOTE M: FOR DETAIL OF BOOM LOWERING CHECK VALVE AUXILIARY CONTROL CIRCUIT MEDIA NUMBER: M0095369-05
VARIABLE ANGLE BOOM RETRACT NOTE N: FOR USE AS STICK LOWERING CHECK VALVE
SWING CONTROL CIRCUIT
SCHEMATIC PART NUMBER: 490-3960, CHANGE: 05, VERSION: HE
82 DRAIN / RETURN LINE
PRESSURE SOLENOID NOTE P: FOR USE AS BOOM LOWERING CHECK VALVE PUMP 2 OUTPUT Components are shown installed on a fully operable machine with the key and engine off.
NOTE R: FOR USE AS SMART BOOM SMART BOOM/ BLCV CONTROL CIRCUIT Refer to the appropriate Service Manual for Troubleshooting, Specifications and Systems Operations.
Refer to the Parts Manual using a specific serial number prefix in SIS before ordering parts from this schematic.

16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
MACHINE - RIGHT SIDE VIEW
VIEW ALL CALLOUTS

2 4 3
MACHINE - RIGHT
VIEW ALL CALLOUTS

21
6

8 10

9
MACHINE - TOP
VIEW ALL CALLOUTS

7 20 18 11
1

19

14
MAIN CONTROL VALVE
VIEW ALL CALLOUTS

22

DD

12

13 17

15
16
PUMP - RIGHT REAR
VIEW ALL CALLOUTS

BB AA

CC
CHASSIS - FRONT VIEW
VIEW ALL CALLOUTS
29 54 58 56 60 61 38

51

37

40

59

55

50

33

36
CHASSIS - REAR
VIEW ALL CALLOUTS

A2

43 57

PP

31

A1

32
MACHINE - RIGHT VIEW
VIEW ALL CALLOUTS

26
35 44
T1

25

23
47

46
34
49 48
MACHINE - TOP RIGHT VIEW
VIEW ALL CALLOUTS

39

30

28
52
53 41

42
QUICK COUPLER

24
VA - BOOM
VIEW ALL CALLOUTS

27

45 T2

You might also like