Professional Documents
Culture Documents
Bookmarks X
*This document is best viewed at a
Options
screen resolution of 1024 X 768.
Features
Cover Page
To set your screen resolution do the following:
Tables RIGHT CLICK on the DESKTOP.
Component Select PROPERTIES.
Connector
CLICK the SETTINGS TAB.
Schematic
Machine Views
MOVE THE SLIDER under SCREEN RESOLUTION
Chassis View until it shows 1024 X 768.
Cab View CLICK OK to apply the resolution.
Engine View
*Due to different monitor sizes and PDF reader preferences
The Bookmarks panel will allow you to there may be some variance in linked schematic locations
quickly navigate to points of interest.
EC-C1
When only one callout is showing on a
machine view, clicking on this button will
Click on any text that is BLUE and make all of the callouts visible. This
underlined. These are hyperlinks button is located in the top right corner
that can be used to navigate the of every machine view page.
schematic and machine views.
FUNCTION KEYS
Switch Switch Switch Switch Circuit Breaker
or Motor Variability
CHECK
Control
ACCUMULATORS Unidirectional Bidirectional
Valves
Line Restriction
(Variable)
VARIABLE DISPLACEMENT
Basic Spring Shuttle NON- COMPENSATED
Pilot
Symbol Loaded Line Restriction
Controlled Spring Loaded Gas Charged Restriction
(Fixed)
Unidirectional Bidirectional
MAIN AUX.
Line Restriction
PILOT CONTROL 2-Section
RELEASED PRESSURE ROTATING SHAFTS Variable and Pressure
Compensated
Pump
Unidirectional Bidirectional
External Return Internal Return
Attachment Pump: Variable and
REMOTE SUPPLY PRESSURE Pressure Compensated
COMBINATION CONTROLS
LINES MEASUREMENT
Solenoid Solenoid Solenoid Solenoid and Servo Thermal Detent Crossing Joining
or Manual and Pilot Pilot or Manual Pressure Temperature Flow
Push-pull Lever Manual Shutoff General Manual Push Button Pedal Spring Vented Pressurized Return Above Fluid Level Return Below Fluid Level
Reed Switch: A switch whose contacts are controlled by a magnet. A magnet closes the contacts of Harness Connector Serialization Code: The "C" stands for
"Connector" and the number indicates which connector in the
a normally open reed switch; it opens the contacts of a normally closed reed switch.
harness (C1, C2, C3, ...)
L-C12
Sender: A component that is used with a temperature or pressure gauge. 3E-5179
The sender measures the temperature or pressure.
T Its resistance changes to give an indication to the gauge of the temperature or pressure. 5A
Component
Relay (Magnetic Switch): A relay is an electrical component that is activated by electricity. Fuse (5 Amps) 9X-1123 Part Number
It has a coil that makes an electromagnet when current flows through it.
The electromagnet can open or close the switch part of the relay. 325-AG135 PK-14
Harness identification code:
This example indicates wire group 325, Wire Gauge
Solenoid: A solenoid is an electrical component that is activated by electricity. wire 135 in harness "AG". Wire Color
It has a coil that makes an electromagnet when current flows through it.
The electromagnet can open or close a valve or move a piece of metal that can do work. 1 Deutsch connector: Typical representation
of a Deutsch connector. The plug contains all
2 sockets and the receptacle contains all pins.
Magnetic Latch Solenoid: An electrical component that is activated by electricity and held latched by a
permanent magnet. It has two coils (latch and unlatch) that make electromagnet 1 Sure-Seal connector: Typical representation
when current flows through them. It also has an internal switch that places of a Sure-Seal connector. The plug and receptacle
2 contain both pins and sockets.
the latch coil circuit open at the time the coil latches.
UENR3964-02
July 2018
© 2018 Caterpillar CAT, CATERPILLAR, their respective logos, “Caterpillar Yellow”, and the POWER EDGE trade dress as well as
All Rights Reserved corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission.
COMPONENT LOCATION
Page 1 of 2
Tap Schematic
Description
Number Location
AA Implement Pump Pressure D-5, G-3
EE Charge Pressure A-14
MA Main System Pressure (Pump 2 Reverse) A-13
MB Main System Pressure (Pump 2 Forward) C-13
MC Main System Pressure (Pump 1 Forward) C-14
MD Main System Pressure (Pump 1 Reverse) A-14
SOS Oil Sampling F-11
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
(16) MOTOR GP
HYDROSTAT (ONE SPEED)
378-2823
ONE SPEED HYDROSTAT MOTORS 257D
LOC A-12
TO RADIATOR
X2 AND HYDRAULIC
LOADER ARMS MANUAL LOWER VALVE
OIL COOLER
LIFT CYLINDERS C2 TO HYDRAULIC TANK
LOC B-7
J J
Ls TO PORT X OF WORK TOOL PUMP
LOC D-11
LH TILT CYLINDER RH TILT CYLINDER
LOC E-7
H FROM PORT B1 OF TWO SPEED
FROM PORT H OF RIDE CONTROL VALVE B1 PILOT SHUTOFF MANIFOLD
LOC B-4
FROM PORT R OF RIDE CONTROL VALVE R
LOC E-7 (8) FITTING GP
QUICK COUPLER
(27) SENSOR GP 388-7960 (ALL MODELS)
SPEED - MOTOR
262-3764
(27) SENSOR GP
SPEED - MOTOR
262-3764
n n
(19) MOTOR GP
HYDROSTAT (TWO SPEED)
C D X7 A B
373-8424 (257D)
LOC C-14 LOC C-14 LOC C-13 LOC C-13 LOC C-13
I 442-5648 (259D)
A B A B T0 Ls Pp A B
I
442-5661 (277D/287D)
442-5642 (279D/289D)
TO RADIATOR
W1 AND HYDRAULIC
OIL COOLER
LOC B-10
TWO SPEED HYDROSTAT MOTORS 257D/259D/277D/279D/287D/289D
LOC A-12
TO RADIATOR
X2 AND HYDRAULIC
OIL COOLER
(33) VALVE GP
IMPLEMENT CONTROL (XHP/XPS HIGH FLOW)
456-1770 (242D/262D/277/279D/287D/289D)
H H
(27) SENSOR GP
SPEED - MOTOR
262-3764
(27) SENSOR GP
SPEED - MOTOR
262-3764
n n
C D X7 A B
LOC C-14 LOC C-14 A1 LOC C-13 LOC C-13 LOC C-13 (27) SENSOR GP
(27) SENSOR GP LOC B-4
FROM PORT A1 OF TWO SPEED
SPEED - MOTOR
SPEED - MOTOR
PILOT SHUTOFF VALVE 383-6830 (236D/242D)
383-6830 (236D/242D)
262-3764 (246D/262D)
262-3764 (246D/262D)
(13) MOTOR GP
TWO SPEED HYDROSTAT MOTORS 236D/242D/246D/262D HYDRAULIC FAN (STANDARD)
(17) MOTOR GP LOC A-12 (18) MOTOR GP 307-3036 (236D/242D/257D/259D)
HYDROSTAT (TWO SPEED) LH TO COOLER CI
HYDROSTAT (TWO SPEED) RH
X2
G 358-5011 (236D/242D) n n
358-5013 (236D/242D) G
358-5005 (246D/262D) A R 358-5007 (246D/262D)
Pg P T
XHP/XPS HIGH FLOW
B C2 TO HYDRAULIC TANK
I I LOC B-7
(7) FILTER AS
HYDRAULIC AND TRANSMISSION OIL
479-0592 (ALL MODELS) FmO FmI
R A Fl Fml
LOC F-11 LOC F-9
(4) CYLINDER GP
(5) CYLINDER GP (34) VALVE GP LIFT
B2 (2) ACCUMULATOR GP
X Y Y X TILT (LH) LOADER ARMS MANUAL LOWER 380-5668 (242D/257D/259D)
LOC A-8
STANDARD FAN RIDE CONTROL 378-7964 (236D/242D/257D/259D) 437-2882 (ALL MODELS) 378-0891(236D)
310-8460 (ALL MODELS) 293-5712 (ALL OTHER MODELS)
A1 (6) CYLINDER GP 492-4507 (262D/287D/289D)
LOC B-4 TILT (RH) 492-4510 (246D/277D/279D)
(11) MANIFOLD GP
FROM PORT A1 OF TWO SPEED 378-7963 (236D/242D/257D/259D)
RIDE CONTROL
F PILOT SHUTOFF VALVE
456-1824 (236D/242D/257D/259D) 293-5711 (ALL OTHER MODELS) F
437-2878 (ALL OTHER MODELS)
C D X7 A B Fml
FO FI FmO FmI P
LOC C-14 LOC C-14 LOC C-13 LOC C-13 LOC C-13
Fl B1
TO RADIATOR
T R W1 AND HYDRAULIC
(23) PUMP GP OIL COOLER
IMPLEMENT AND CHARGE (HIGH FLOW) R LOC B-10
C D X7 A B
LOC C-14 LOC C-14 LOC C-13 LOC C-13 LOC C-13
S1
ONE SPEED HYDROSTAT MOTORS 246D, AND 262D
S L2 L1 L
I
I (14) MOTOR GP HIGH FLOW IMPLEMENT PUMP FROM PORT X OF WORK TOOL PUMP LS
Ls
HYDROSTAT (ONE SPEED) LOC D-11
D R 455-7987 (246D/262D) L
S D
LOC B-8
Pg
LOC D-5
AA
FROM PORT Ls OF
B Ls IMPLEMENT CONTROL VALVES
(27) SENSOR GP
B X FROM IMPLEMENT PUMP B
SPEED - MOTOR
383-6830 (236D/242D)
262-3764 (ALL OTHER MODELS)
L R (24) PUMP GP
WORK TOOL
258-2555 (236D/242D/257D/259D)
487-6181 (ALL OTHER MODELS)
n
MC MB (28) STRAINER AS
HYDRAULIC TANK
M3
X7
C
B M 456-1838 (236D/242D/246D/257D/262D)
TO PORT Y OF TWO SPEED
HYDROSTAT MOTORS
A1
A1
T
6E-4701
CALLOUTS B
P LOC F-12 B2 TO HYDRAULIC TANK YY Taps (Pressure, Sampling, Sensor - by letter)
LOC A-8
Callout Number Component
(Machine Location from (52) VALVE GP - CONTROL Name
Component LocationsTable)
TO PORT Pp OF XHP/XPS 138-1234 Part Number
B1
STANDARD FLOW IMPLEMENT PUMP HIGH FLOW IMPLEMENT B1
FROM QUICK COUPLER CONTROL VALVE LOC J-1
FITTINGS Tap Locations
W1 Pressure and Sampling HYDRAULIC CIRCUIT COLOR DESCRIPTIONS
(1) ACCUMULATOR Tap Schematic PILOT PUMP OUTPUT
227-8807 Description MAIN PUMP OUTPUT
Number Location
L2 MD E L1 MA L3 AA Implement Pump Pressure D-5
TILT CYLINDER CIRCUIT
CHARGE PUMP OUTPUT
(21) PUMP GP CI CO AA Implement Pump Pressure G-3
A1 HYDRAULIC FAN CIRCUIT
HYDROSTAT EE Charge Pressure A-14 LOAD SENSE CIRCUIT
EE 378-2822 (ALL OTHER MODELS) (25) RADIATOR AND HYDRAULIC OIL COOLER GP B2
(30) VALVE GP MD MA X2 ONE SPEED TWO SPEED MA Main System Pressure (Pump 2 Reverse) A-13 SUPPLY LINE
CHECK (COOLER BYPASS) 398-7456 (246D/262D) 345-3609 (236D/242D/257D/259D) FROM PORT T OF MB Main System Pressure (Pump 2 Forward) C-13 QUICK COUPLER CIRCUIT
373-7039 (ALL MODELS) 345-3473 (ALL OTHER MODELS) TWO SPEED PILOT SHUTOFF MANIFOLD PILOT SHUTOFF PILOT SHUTOFF MC Main System Pressure (Pump 1 Forward) C-14
DRAIN / RETURN LINE
LOC B-3 (1) ACCUMULATOR GP STEERING CIRCUIT
MD Main System Pressure (Pump 1 Reverse) A-14 TRAVEL CONTROL CIRCUIT
227-8807 SOS Oil Sampling F-11 LIFT CYLINDER CIRCUIT
A A
THIS SCHEMATIC IS FOR THE 236D, 242D, 246D, AND 262D SKID STEER LOADER
257D, 277D, AND 287D MULTI-TERRAIN LOADER
259D, 279D, AND 289D COMPACT TRACK LOADER HYDRAULIC SYSTEM
Do not operate or work on this product unless you have
read and understood the instruction and warnings in the
MEDIA NUMBER: UENR3964-02
relevant Operation and Maintenance Manuals and SCHEMATIC PART NUMBER: 345-5170, CHANGE: 09, VERSION: -
relevant service literature. Failure to follow the instruc-
Components are shown installed on a fully operable machine with the key and engine off and with parking brake set.
tions or heed the warnings could result in injury or
death. Proper care is your responsibility. Refer to the appropriate Service Manual for Troubleshooting, Specifications and Systems Operations.
Note: Refer to the Parts Manual using a specific serial number prefix in SIS before ordering parts from this schematic.
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
FRONT VIEW
VIEW ALL CALLOUTS
26
27
22
23
24
8
20
14
15
16
6 5
REAR VIEW
VIEW ALL CALLOUTS
12
25 13
7 SOS
19 19
EE 30
MA MD 21
RIGHT SIDE VIEW
VIEW ALL CALLOUTS
3 AA 32 33 35
1
4
10
31
11
2
4
17
34
29
28
18 MB MC