You are on page 1of 2

PRODIGY48

Remote Monitoring/Control/Power Center for Solar & UPS Backup Solutions


One unit that gives you complete control & monitoring of your remote Solar and UPS Backup units through your connected antenna
or cellular gateway. Email alerts notify you in the event of developing problems at the site.

Intelligent - Powerful - Affordable


Remote Power Cycle Power In/Output, Battery,
Individual PoE Ports Turbine Disconnects

(1200W Skid Kit)

48/24 VDC Auxiliary Port


features Controlled by Voltage,
Temperature, Time
Power In/Out
Connections
Smart Selectable PoE Switch
• Gigabit PoE Switch with Passive Ports
(3) PoE+ 35W, (4) PoE 18W
• Power Cycle Individual Ports Auto/Manually
• Ports 1-7 Selectable as 24V, 48V, or OFF by User
• Selectable Auto Ping Watchdog Power Cycle Popular Applications
• Surveillance with Antenna or Cellular Gateway
• Remote IoT & M2M (Gas & Oil, Mines Agriculture)
Remote Monitoring/Control • Wireless Bridges/Backhauls (WISP)
• View System & Control through your Web Interface or SNMP • SCADA Upgrades (Gas & Oil, Agriculture)
• Log and graph the history of up to 15,000 Data Sets • UPS/Solar Backup Control (Cell Towers, Utilities)
• Auto Power Cycle or ON/OFF Auxiliary Power & Ports based on
change in Voltage, Temperature, Time or Ping
• Smart Battery Charging Based on Temperature
• Monitor and Graph a Systems: Power Control Through the Web
- Battery Voltage, Current, Temperature & Charge Level • Notify User of any Change of In/Output Power
- Input Voltage, Current & Load
• Power Cycle Individual PoE & Aux Ports
• Change Voltage of Individual PoE & Aux Ports
• Customize 200W of Available Power
Customizable Email Alerts • Powerful Automated Alerts/Resets
• Automated Email Alerts if User Programmed Limits are Exceeded • Smart Battery Charging Based on Temperature
• Alerts when:
- Battery Voltage Drops Below a User Set Voltage
- Temperature Reaches a Min/Max
- IP Address Ping Fails (x) Number of Times
- Battery Voltage Drops Below a Set Voltage
PRODIGY48 Specs
Alert Control Interface
220W Total (150W @ 48VDC and 70W @ 24VDC)
Total Max Power Output
from all output ports (including Aux Output)

(7) RJ45 10/100/1000MB Gigabit Ethernet,


PoE Switch
Auto Crossover, Layer 2

PoE Output Voltage 48VDC or 24VDC or OFF (Adjustable in Web Interface)

Port 1-3: 35W Passive PoE+ at 48VDC, 18W at 24VDC


PoE Output Power Ports 4-7: 17W Passive PoE at 48VDC, 9W at 24VDC
PoE Power supplied on pins 4,5 (V+) and 7,8 (V-) (Mode B)

Aux DC Output Voltage 24 VDC or 48 VDC (Adjustable in Web Interface)

Aux DC Output Current 2.25A Maximum


Power Control Interface
Aux DC Output Controls Set in Web Interface by Temperature, Voltage, or Time

Battery Volt/Current 48 VDC / 20A Max

Battery Type Sealed Lead Acid (SLA) or Lithium Iron (LiFePo4)

Solar Volt/Current Input 62 - 80 VDC, 20A Maximum

Fuse Type 58V 20A Fast Acting Automotive (Littelfuse 142.6185.5206)

Low Voltage Disconnect 45.8 - 47.8 VDC Adjustable in Web Interface


Recovery from LVD 48.1 - 49.2 VDC Adjustable in Web Interface
IEC 61000-4-2 (ESD) 15kV (air), 15kV (contact)
Port Surge Protection IEC 61000-4-4 (EFT) 40A (5/50ns)
IEC 61000-4-5 (Lightning) 25A (8/20µs) Data Graph Interface
LED #1 - Overload Warning: (Red)
LED #2 - External DC Power ON: (Green)
LED Control Lights LED #3 - Aux Out Voltage: (24VDC (Green)
(48VDC (Orange)
LED #4 - Battery Charging: (Green)

Self Power Consumption 1 - 3 Watts (if PoE ports not in use)


Via Web Browser and SNMP
Accessibility
Data-Logger FIFO, 15,000 data sets, Programmable log
Operating Temperature -76F to 158F (-60C to +70C) Humidity: (RH) 0% - 90%
Dimensions (HxWxD) 5.5” x 14” x 5.75”
Weight 4.2lbs
FCC/CE EN55022 (EMC); CE EN55024 (EMC);
Certifications
CE/UL EN60950-1 (LVD)
Data Monitor Interface

4774 South Hwy 191


Rexburg, ID 83440
Phone : + (208) 904-0424
(300W Kit above)
E-Mail : support@vorpenergy.com