You are on page 1of 2

Microsart® e.

jet
Laboratory Transfer Pump with Quick Connection for Microbiological Analysis

Technical Specification
Flow rate > 4.0 Nl/min
Max. Vacuum 0.4 bar
Max. Pressure 1.0 bar
Microbiological Analysis

Materials PTFE, ETFE,


(contact with Polypropylene, EPDM,
filtrate) POM, PSU
Mains 100-240 V | 47-63 Hz
Weight
Pump 1,425.3 g
Power supply 242.6 g
Dimensions 12+ 17+19 cm
(W + L + H)
Max. ambient temp. +5…+40°C
Max. temp. of liquid +5…+80°C
Max. viscosity < 150 cSt*
Typical Set-up: Microsart® e.jet connected to a 3-branch manifold with Microsart® Funnels 100 Protection type IP 64
Protection class l
Inlet | Outlet Quick Connection
New pump for vacuum filtration in Microsart® e. jet and stainless steel manifold
on hose nipples for
Microbiological Analysis require only 30% of the average space, which
DN 10 tubings
The Microsart® e.jet is a laboratory vacuum translates to less congestion when working
pump which creates vacuum and concomi- in laminar flow cabinets.
tantly transfers the filtered liquid to waste. Ordering Information
The Microsart® e.jet is ideal for sample pre- Safe operation | Maintenance-free Order Number Description
paration in microbiological analysis achieving Traditional vacuum pumps often lose their
a trans membrane pressure of 600 mbar efficiency and capability to generate suf- 166MP-4 Microsart® e.jet
and a flow rate of 4.0 Nl/min (4.0 Normliters ficient vacuum, when liquid is drawn into the Transfer Pump
water displacement by air in one minute). pump head. The Microsart® e.jet is designed
Constant flow rates and a defined maximum to pump both gas and liquids, meaning no Spare Parts
vacuum guarantees a smooth and reliable loss of efficiency or malfunction from water
filtration. drawn into the pump head. Order Number Description
1EP---0003 Pump head complete
Reduced operating complexity Building-up the vacuum filtration system is for 166MP-4
Until now vacuum equipment for the easy and fast thanks to the innovative Quick
Membrane Filtration Method consists of ®
Connections. The Microsart e.jet Transfer 1EE---0012  Power supply complete
Sartorius Lab Instruments
numerous parts including connectors, tubes, Pump is equipped with Quick Connection for 166MP-4
GmbH & Co. KG
vacuum containers, protection filter, Woulff’s Nipples assembled to Quick Connection 1EAS--0027  2 Quick Connection
Otto-Brenner-Strasse 20
bottle and a vacuum pump. After several Couplings on hose nipples for DN 10 tubings. Couplings (PSU)
37079 Goettingen, and
Germany
samples the vacuum must be broken to empty Simply push-to-connect for assembling and 2 Nipples (POM)
Phone +49.551.308.0
the filtrate collection container. The complete pull-to-disassembling the whole sytem
Fax +49.551.308.3289
1ZE---0053 Foot switch
traditional equipment requires far more labo- within seconds. The Quick Connections are
www.sartorius.com
ratory space and is time consuming to oper- non-shut-off.
ate and maintain. The new Microsart® e.jet Sartorius Lab Instruments USA Toll-free +1.800.635.2906
greatly reduces operating complexity. GmbH & Co KG UK +44.1372.737159
Otto-Brenner-Strasse 20 France +33.1.70.62.50.00
Smart design fits any laboratory 37070 Goettingen, Germany Italy +39.0362.5557.11
environment Phone +49.551.308.0 Spain +34.913.586.095
The Microsart® e.jet pump is an ideal accessory Fax +49.551.308.3289 Russian Federation +7.812.327.53.27
for 3-branch and 1-branch manifolds. www.sartorius.com Japan +81.3.3740.5408
Compared to traditional equipment, the Specifications subject to change without
Specifications
notice. subject
Copyright to change
Sartorius without notice.
Lab Instruments
Copyright
GmbH Sartorius
& Co. Lab Instruments
KG. Printed in the EU onGmbH
paper & Co. KG.
Printed inwithout
bleached the EU on paper bleached without chlorine.
chlorine.
Publication No.:
Publication No.: SM-2008-a170805
Order No.:
Order No.: 85034-539-02
Ver. 08
Ver. 01 || 2017
2017
Microsart® e.jet
Labor Transferpumpe mit Quick Connection für die Mikrobiologische Analyse

Spezifikationen
Durchflussrate > 4,0 Nl/min
Endvakuum 0,4 bar
Max. Druck 1,0 bar
Mikrobiologische Analyse

Materialien PTFE, ETFE,


(Filtrat-berührt) Polypropylen, EPDM,
POM, PSU
Netzanschlüsse 100–240 V | 47–63 Hz
Gewicht
Pumpe 1.425,3 g
Netzteil 242,6 g
Abmessungen 12+ 17+19 cm
(B + L + H)
Max. Umgebungs- +5…+40°C
temperatur
Max. Medium- +5…+80°C
temperatur
Typischer Aufbau: Microsart® e.jet angeschlossen an eine 3-fach Edelstahlleiste mit
Microsart® Funnels 100 Max. Viskosität < 150 cSt
Schutztyp IP 64
Neue Pumpe zur Vakuumfiltration in der lichem Equipment benötigen Microsart® e.jet
mikrobiologischen Analyse zusammen mit einer Edelstahlleiste lediglich Schutzklasse l
Microsart® e.jet ist eine neue Laborvakuum- 30% des Platzes und eignen sich hervorragend Ein- und Auslass Quick Connection für
pumpe, die während der Vakuumfiltration, für Arbeiten in einer Reinen Werkbank. DN 10 Schläuche
das Filtrat gleichzeitig dem Abfluss zuführt.
Mit einem Transmembrandruck von 600 mbar Wartungsfrei
und einer Durchflussrate von > 4,0 Nl/min Ein weiterer Vorteil ist, dass Microsart® e.jet Bestellinformationen
(4,0 Normliter Wasserverdrängung durch weder an Effizienz verliert, noch Störungen Bestellnummer Beschreibung
Luft in einer Minute) ist sie ideal zur mikro- während der Anwendung auftreten, weil
166MP-4 Microsart® e.jet
biologischen Analyse geeignet. Konstante Flüssigkeit in den Pumpenkopf eingedrungen
Transferpumpe
Durchflüsse und ein definiertes Maximum- ist. Außerdem kann sie nicht nur Flüssigkeiten
vakuum garantieren schonende und zuver­ sondern auch Gase fördern.
lässige Filtration. Ersatzteile
Der Aufbau des Vakuumfiltrationssystems ist Bestellnummer Beschreibung
Einfacher Aufbau und Non-Stop dank der innovativen Quick Connections
Filtrationen 1EP---0003 Pumpenkopf für
einfach und schnell. Die Microsart® e.jet
Herkömmlicherweise setzt sich ein Vakuum- 166MP-4, komplett
Transfer Pumpe ist mit Quick Connections auf
system für die Membranfiltrationsmethode Schlaucholiven versehen, welche für DN 10 1EE---0012 Netzstecker für
aus einzelnen Komponenten, wie Filterhalter, Schläuche geeignet sind. Zum Anbringen 166MP-4, komplett
Saugflasche, Wasserfalle, Vakuumpumpe, genügt ein einfaches Andrücken, zum
Schläuche, Anschlüsse etc. zusammen. 1EAS--0027 2 Quick Connection
Abbauen ein einfaches Abziehen der Quick Kupplungen (PSU) und
Nach einigen Filtrationsdurchgängen muss Connections. Die Quick Connections besitzen
das Vakuum entspannt werden, um das 2 Stecknippel (POM)
keine Absperrvorrichtung.
gesammelte Filtrat aus der Saugflasche zu 1ZE---0053 Fußschalter
verwerfen. Dieser raumintensive Aufbau und
die aufwändige Durchführung gehören mit
Microsart® e.jet der Vergangenheit an, das Sartorius Lab Instruments Specifications subject to change without
notice. Copyright Sartorius Lab Instruments
Filtrat wird direkt einem Ausguss zugeführt. GmbH & Co KG GmbH & Co. KG. Printed in the EU on paper
Otto-Brenner-Straße 20 bleached without chlorine.
Publication No.: SM-2008-a170805
Kompaktes Design 37070 Göttingen Order No.: 85034-539-02
Telefon 0551.308.0 Ver. 08 | 2017
Die Vakuumpumpe Microsart® e.jet ist optimal
für die Filtration mittels 1-fach und 3-fach Fax 0551.308.3289
Edelstahlleisten. Im Vergleich zu herkömm­ www.sartorius.com
Schweiz +41.44.746.50.00
Österreich +43.1.7965760.0