A Design and Implementation of Short Circuit Indicator


Abstract
Short circuit condition is a condition in which the input terminals of a power supply get in
electrical contact with each other causing huge current flow. This leads to very large heat generation
which can damage the system and also pose a threat to people near by it.Thus, short circuit condition
is necessary to be detected and be attended immediately.Short Circuit Indicator Project does the task
of detecting the short circuit in a circuit in which it is connected automatically. With the help of
regulator and a pair of transistors we lit up an indicator LED that glows only when there is short circuit
event occurring. In this way one can easily understand the short circuit condition and take appropriate
measure of cutting off the power supply and removing the short circuit.We have demonstrated the
short circuit in our circuit board using a wire piece which has very low, close to zero value of
resistance thus creating a short circuit at the source connector.
Dr.Sunitha.R1
Keywords: Buzzers,Diodes,Resistors,Transistors,PCB,LED
Author Affiliation: 1Department of Electrical and Electronics Engineering ,QISCET,JNTUK University, Ongole- 523201,AP,India.
Corresponding Authors: N.LEKHANA,UGScholar,DepartmentofEEE,QISCET,Ongole,AP,India
G.VAMSI,UGScholar,DepartmentofEEE,QISCET,Ongole,AP,India
G.VYSHNAVI,UGScholar,DepartmentofEEE,QISCET,Ongole,AP,India
K.SATHWIKRAJU,UGScholar,DepartmentofEEE,QISCET,Ongole,AP,India
G.NAVEEN,UGScholar,DepartmentofEEE,QISCET,Ongole,AP,India
Email: gollanaveennavi@gmail.com sathwikrajuk@gmail.com

well. In industrial and utility distribution systems, dynamic by


1.INTRODUCTION
high short- forces generated circuit currents cause conductors to
Short circuit can cause circuit damage, overheating,
spread apart. Bus bars, cables, and apparatus can be damaged
fire or explosion. Although A Short circuit is an abnormal
by the forces generated in a short circuit.
connection between two nodes of an electric circuit
intended to be at different voltages. This results in an
electric connected limited only by the Thevenin equivalent 2.Literature Review
resistance of the rest of the network which usually the Recently, various investigations on transmission line fault
result of a fault, there are cases where short circuits are analysis using WT, KPCA, NN, SVM,FLC,AFL and WSE etc.,
caused intentionally, for example for the purpose of voltage have been discussed. With their application certain
sensing crowbar circuit protectors. Short circuit is a investigation on transmission line fault analysis is proposed
condition in which the input terminals of the power supply in the research work. Few schemes for fault detection,
get in contact with each other causing huge current flow. classification and location of power transmission lines are
presented.
This leads to very large heat generation which can damage
Short circuit current literature survey report contains the
the system and also pose a threat to people nearby it. Thus,
results of a literature investigation on short circuit current
short circuit condition is necessary to be detected and be
limiters the occasion for this is a research program
attended immediately. Short circuit indicator project does
performed in the group called apparatus and systems for
the task of detecting the short circuit in a circuit in which it
electrical energy supply of the Eindhoven University of
is connected automatically.With the help of regulator and a
technology on a method of short circuit current limiting.
pair of transistors we lit up a indicator LED which glows up
For this research the availability of survey of the literature
only when there is short circuit occurring. In this way one on the subject appeared desirable. With reference to
can easily understand the short circuit condition and take A.Bhatia (introduction to short circuit)
appropriate measure of cutting of the power supply and A short circuit results in excessive current flow in the power
removing the short circuit. source through the 'short,' and may even cause the power
In main circuits, short circuits may occur between two source to be destroyed. In electrical devices, unintentional
phases, between a phase and neutral or between a phase short circuits are usually caused when a wire's insulation
and earth. Such short circuits are likely to result in a very breaks down, or when another conducting material (such as
high current and therefore quickly trigger an over current water) is introduced, allowing charge to flow along a
protection device. To help reduce the negative effects of different path than the one intended.
short circuits, power distribution transformers are
deliberately designed to have a certain amount of leakage Damage from short circuits can be reduced or prevented by
reactance. In power sockets or even the site of the short employing fuses, circuit breakers, or other overload
circuit itself). Such is a common cause of an electric arc, if protection, which disconnect the power in reaction to
it forms during the short circuit, produces high amount of excessive current. If a fuse is in the supply circuit, it will do
heat and can cause ignition of combustible substances as its job and blow out, thus opening the circuit and stopping

1 South Asian Journal of Engineering andTechnology 11(1) (2021) 1-3


the current flow. If a circuit breaker is in the supply currents are usually much higher than normal in – service
circuit, it will trip and open the circuit. currents, because they are no longer limited by the load
Example regarding reference:- impedance and may only be limited by the impedance of
the transformer itself. The short circuit may arise because
A common type of short circuit occurs when the positive of a defect arising in the another item of network
and negative terminals of a battery are connected with equipment, or as a result of a system or environmentally
a low-resistance in the connection, like a wire With a generated transient , example close up lightning strike,
low resistance in the connection, a high current will which causes a phase to earth fault. Arising from the radial
flow, causing the delivery of a large amount of energy and axial forces acting on windings, the major deformation
in a short period of time. modes caused by fault currents are:
1. Radial buckling
A high current flowing through a battery can cause a 2. Conductor tilting
rapid increase of temperature, potentially resulting in
an explosion with the release of hydrogen gas and 3. Conductor bending between supporting spacer
electrolyte(an acid or a base), which can burn tissue columns, local distortion of the winding.
and cause blindness or even death. Overloaded wires 4. Conductor telescoping in winding's of limited radial
will also overheat causing damage to the wire's thickness and restraint where conductors have been able
insulation, or starting a fire. High current conditions to pass axially passed each other.
may also occur with electric motor loads under stalled 5. Spiral tightening under twisting forces
conditions, such as when the impeller of an electrically 6. Collapse of the winding and supports Movement of the
driven pump is jammed by debris; this is not a short, winding leads, particularly tap leads.
though it may have some similar effects.
3. Research Methodology
In electrical devices unintentional short circuits are Here we use two transistors T1 and T2. T1 is the general
usually caused when a wire's insulation breaks down, or purpose NPN transistor BC 547 and T2 is the medium power
when another conducting material is introduced, PNP transistor SK 100. It is also available as CK 100 and
allowing charge to flow along a different path than the BEL 100 P. At power on, T1 conducts and pulls the base of
one intended. T2 to ground potential. Since T2 is a PNP transistor, it
conducts when its base becomes negative. So full power is
In mains circuits, short circuits may occur between two available at the collector T2 which is used to power the
phases, between a phase and neutral or between a bread board. Green LED lights at this time to indicate the
phase and earth (ground). Such short circuits are likely availability of output power and no short in the bread
to result in a very high current and therefore quickly board.SK 100 can deliver maximum 800 mA current so
trigger an over current protection device. However, it almost full supply voltage (less 0 .6 to 0.8 volts due to D1
is possible for short circuits to arise between and T2) is available in the board.
neutral and earth conductors, and between two
conductors of the same phase. Such short circuits can
be dangerous, particularly as they may not immediately
result in a large current and are therefore less likely to
be detected. Possible effects include unexpected
energisation of a circuit presumed to be isolated. To
help reduce the negative effects of short circuits,power
distribution transformers are deliberately designed
to have a certain amount of leakage reactance. The
leakage reactance (usually about 5 to 10% of the full
load impedance) helps limit both the magnitude and
rate of rise of the fault current.
A short circuit may lead to formation of an electric arc.
The arc, a channel of hot ionized plasma, is highly
conductive and can persist even after significant
amounts of original material from the conductors has
evaporated. Surface erosion is a typical sign of electric
arc damage. Even short arcs can remove significant
amounts of material from the electrodes. The
temperature of the resulting electrical arc is very high If the bread board power is ok, Red LED remains off since
(tens of thousands of degrees), causing the metal on its cathode is connected to the output and in a high state.
the contact surfaces to melt, pool and migrate with the When a short circuit occurs in the board, Green LED
current, as well as to escape into the air as fine extinguishes and Red LED lights. Short circuit in the output
particulate matter. blocks the collector current of T2 so the cathode of Red
Short circuit forces and winding deformation failure LED gets the current path and it lights. Green LED remains
modes: off due to the absence of current from T2.
When a transformer is subjected to a short circuit in the 4. Finding and discussion
attached network, then it experiences considerably Short circuit indicator is a simple and easy. But it require
increases current flows for the duration of the external an DC power to operate at fault conditions of a system or in
fault. The magnitudes of the resulting ‘through fault’ a system’s circuit. Al the hardware equipment should be

3 South Asian Journal of Engineering and Technology 11(1) (2022) 1-3


installed on printed circuit board in possible switching 6. References
and indication of equipment whenever the fault occurs [1]"LabNote#105ContactLife-
in the system. The proposed system can be developed Unsuppressedvs.SuppressedArcing".Arc
with a law budget compared to currently available short SuppressionTechnologies.April2011.RetrievedFebruary5,201
circuit indicators. In addition, the user does not need to 2.
stay near the PCB to check whether fault is detected, [2]ManishabenJaiswal“SOFTWAREARCHITECTUREANDSOFTW
as they can sense and indicate the system automatically. AREDESIGN”
Further, since the system is automated, the users do InternationalResearchJournalofEngineeringandTechnology(I
not want to control motor manually. RJET)e-ISSN:2395-
0056,p-ISSN:2395-0072,Volume:06Issue:11,s.no-
5. Conclusion 303,pp.2452-2454,Nov2019
Finally, in short circuit study, we have to learn about Availableat:https://www.irjet.net/archives/V6/i11/IRJET-
the short circuit and we have to clarify some doubtable V6I11303.pdf
questions like: what is short circuit? How it happens? [3]ManishabenJaiswal"RISKANALYSISININFORMATIONTECHNO
When it happens? Why it happens? , when it happen? , LOGY",
why it happens? And also learn prevention methods of InternationalJournalofScientificResearchandEngineeringDev
short circuit study. Short circuit (fault current) studies elopment(IJSRED),
are required to insure that existing andnew equipment ISSN:2581-7175,Vol2-Issue6,P110,pp.857-860,November-
rating are adequate to withstand the available short December2019Available
circuit energy at each point in the electrical system. at:http://www.ijsred.com/volume2/issue6/IJSRED-
Whenever you are working with electricity, the proper V2I6P110.pdf
use of safety precautions is of the utmost importance to [4]ManishabenJaiswal,MehulPatel“THELEARNINGONCRMINER
remember, in the front of all electronic technical P-WITH
manuals, you will always a find a section on safety SPECIALREFERENCESTOSELECTEDENGINEERINGCOMPANIESIN
precautions. Also posted on each piece of equipment GUJARAT”,
should be sign list in the specific precautions for that InternationalJournalofManagementandHumanitiesScopus(IJ
equipment. One area that sometimes over looked, and MH),publishedby
is a hazard especially on-board ship, is the method in BlueEyesIntelligenceEngineering&SciencesPublication(BEIES
which the equipment is grounded. By grounding the P),ISSN2394-0913,
return side of the power transformer to the metal Volume-4Issue-8,April2020,Pg-117-
chassis, the load being supplied by the power supply 126,AvailableAt,http://www.ijmh.org/wp-
can be wired directly to necessity of wiring directly to content/uploads/papers/v4i8/H0798044820.pdf
the return side of transformer is eliminated. Fault [5]Bhatia,A."IntroductiontoShortCircuitAnalysis"(PDF).PDHon
currents that exceed equipment rating are capable of line.sec.What
extensive equipment damage and are serious threat to causesashortcircuit?.Retrieved3July2019.Laysummary–
human life. Recently, CourseE204.
23000 fire complaints a year from all over state. There [6]^BasicElectronics.I.K.InternationalPvtLtd.pp.184–
are a lot of fire accidents are occurred due to this short .GGKEY:9NLKFQ9D0F2.
circuit.To protect the buildings from this short circuits Retrieved20April2011.
we have to learn about this short circuit phenomenon. [7]^RobertSpence(5September2008).IntroductoryCircuits.Jo
Line Short Circuit And Earth Fault Indicator the fault hnWileyandSons.
current in the line will increase, when the current pp.99–.ISBN978-0-470-77971-2.Retrieved20April2011.
increases more than a certain set value, the use of over [8]^U.A.Bakshi;A.P.Godse(1January2010).LinearIntegratedCi
current fault indicator will alarms display. Such rcuits.Technical
indicators need to set a Short Circuit And Earth Fault Publications.pp.4–.ISBN978-81-8431-773-
Indicator alarm threshold in advance, short circuit in 2.Retrieved20April2011.
general400A-1200A,ground generally in the 5-
60A, ,adjustable range. When the line short circuit and
earth fault indicator, the line will occur more
significant instantaneous current changes ,when the
protection device action trip, the line steady current
will be zero. Detection of the current value of this
mutation , but also to determine the short circuit and
earth fault indicator
.Because thus type of indicator does not need to set the
alarm threshold in advance, its scope of application is
more extensive. But because of the need for real-time
monitoring of line current, product power consumption ,
shorter service life.