25 x 25 CHAMFER

200 x 200 x 50 THICK GRANITE


BLOCKS BEDDED AND JOINTED IN
1 : 3 CEMENT / SAND MORTAR

75 THICK GRANITE STONE COPING SLOPE PROFILE


OR AS SPECIFIED BY THE ENGINEER

WEEPHOLES, AS REQUIRED EXISTING OR NEW CONCRETE VERTICAL


(SEE NOTE 3) WALL, INCLINED FACE OF WALL OR
STRUCTURAL MEMBERS WITH MINIMUM
THICKNESS NOT LESS THAN 150 CAST BY
SEE DETAILS OF TIE CONCRETING OR SPRAYED CONCRETE

HEIGHT OF THE LOWEST ROW


OF WEEPHOLES SHALL BE AS 500 OR AS
CLOSE TO GROUND LEVEL AS SPECIFIED BY
POSSIBLE AND SHALL NOT THE ENGINEER
EXCEED 150

PAVING
PAVING

50 THICK 20 MPa
SPRAYED CONCRETE
WEEPHOLES, AS REQUIRED OR GRADE 10 BLINDING
(SEE NOTE 3) CONCRETE AS SPECIFIED

VERTICAL / SUB-VERTICAL WALL AND SLOPE WITH GRANITE BLOCK FACING AT TOE
(DRAINAGE BEHIND VERTICAL WALL NOT SHOWN FOR CLARITY)

MASONRY BLOCK CONCRETE WALL OR


SPRAYED CONCRETE WALL
OR STRUCTURAL MEMBER
EQ. EQ.

55
25

3 THICK 40 WIDE
HOT-DIP GALVANIZED 10 DIA. STAINLESS STEEL
MILD STEEL WALL TIE ANCHOR BOLT WITH WASHER OR
EQUIVALENT AND MINIMUM 79
EMBEDMENT DEPTH

ELEVATION OF GRANITE BLOCK FACING


(SQUARE PATTERN) DETAILS OF TIE
NOTES:

1. ALL DIMENSIONS ARE IN MILLIMETRES. 6. TIES SHALL BE LAID AT A RATE OF 5 NOS.


2
PER m . FOR WALLS HIGHER THAN 2.5 m, THE
2. A TRIAL PANEL OF SIZE 1 m x 1 m SHALL ENGINEER SHALL SPECIFY THE NUMBER OF
BE PREPARED FOR ENGINEER’S APPROVAL. TIES PER m2.

3. WEEPHOLES SHALL BE PROVIDED AS 7. ALL STAINLESS STEEL ANCHOR BOLTS AND


APPROPRIATE. WHERE WEEPHOLES ARE WASHERS SHALL HAVE A DECLARATION OF
REQUIRED, THEY SHALL BE CONSTRUCTED PERFORMANCE FOR THE CONSTRUCTION PRODUCT
OF SINGLE CONTINUOUS PVC PIPES EXTENDED COVERED BY A EUROPEAN TECHNICAL ASSESSMENT
TO THE OUTER FACE OF THE GRANITE BLOCKS. REPORT ETAG 001 OR APPROVED EQUIVALENT.
SUBJECT TO THE ENGINEER’S AGREEMENT,
WATER TIGHT SOCKETED JOINTS MAY
NOTE 7 ADDED. DETAILS FOR ANCHOR
BE PROVIDED AS AN ALTERNATIVE. F Original Signed 07.2018
BOLT REVISED.

4. FOR OTHER PATTERNS, SEE STD. DRG. E MINOR AMENDMENT. Original Signed 03.2015
NO. C2002 / 2. D DETAILS OF WALL TIE REVISED. Original Signed 09.2007
C GENERAL REVISION. Original Signed 12.2005
5. ALTERNATIVE TREATMENT TO CONCRETE
SURFACE INCLUDES RIB FINISH, LARGE B GENERAL REVISION. Original Signed 01.2005
BLOCK PATTERN, APPLICATION OF PAINT A GENERAL REVISION. Original Signed 12.2002
AND SPRAYED GRANITE.
REF. REVISION SIGNATURE DATE

CIVIL ENGINEERING AND


STONE FACING TO
DEVELOPMENT DEPARTMENT
CONCRETE SURFACES SCALE DIAGRAMMATIC DRAWING NO.
(SHEET 1 OF 2) DATE JAN 1991 C2002 / 1F