Professional Documents
Culture Documents
xmcd
2
π× D r × L r Vr 3
-3 m
Volume spécifique : Vr := Vr = 981.7477 L Vvs := Vvs = 50.868 ´ 10
4 Mv kg
( )
3
m 2.038 3 -1
Relation de Bertin Pvs× Vvs = 2.038× bar× Pvs := × bar× m × kg Pvs = 40.065× bar
kg Vvs
4
4
Pvs
Relation de Duperay Tvs = 100× 0.981× Pvs Tvs := 100× 0.981× × °C Tvs = 250.4× °C
bar
Tvs = 523.5 K
Évaluation de la puissance électrique nécessaire P = ΦCV + ΦR
hc× D Ta = 288.1 K
ΦCV = hc× Slat× Tvs - Ta ( ) Nu =
λ
n
= C× ( Gr× Pr) = C× Ra
n
Ta + Tvs
On prend la moyenne arithmétique de T a et Tvs Tm := = 405.8 K
2
et on interpole :
37.90 - 25.90 æ Tm ö -6 2 -1
25.90 + ×ç - 400÷ = 26.60 νm := 26.60× 10 ×m ×s
500 - 400 è K ø
0.04038 - 0.03365 æ Tm ö W
0.03365 + ×ç - 400÷ = 0.03404 λm := 0.03404×
500 - 400 è K ø m× °C
0.680 - 0.689 æ Tm ö
0.689 + ×ç - 400÷ = 0.688 Prm := 0.688
500 - 400 è K ø
3
g× β× D 1 -2
Calcul du nombre de Grashof Gr = × ΔT β := g := 9.81× m× s
2 Tm
ν
3
g× β× Dr
Gr :=
2
( )
× Tvs - Ta = 1.005 ´ 10
9
Ra := Gr× Prm = 6.916 ´ 10
8
νm
régime laminaire
.25
Nu× λm W
Nu := 0.53× Ra = 85.947 hc := = 5.851
Dr 2
m ×K
-8 -2 -4 (
ΦCV := hc× π× Dr× Lr× Tvs - Ta = 10.817 kW )
σ := 5.67× 10 × W× m ×K
ΦR = σ× Slat× æ Tvs - Ta ö
4 4
è ø
P := ΦCV + ΦR = 41.202 kW
MH 1/1 18/05/2012