Project : 2-Storey Commercial BLDG Design by :
LOGO
Owner : Mark : CF1
Location : FREEDOM PARK SUBDIVISION, BRGY SAN VICENTE, GAPAN CITY N.E. Date : 6/5/2022
Check by : Engr. Mark Christian D. Esguerra
Material Properties Column Properties: Footing Properties: Reinforcement Details:
Concrete f'c = 20.70 Mpa Exterior Col. to Col. Distance = 1.30 m Location #
Reinforcing fy = 415.00 Mpa Width = 0.30 m Width = 1.80 m Top Bar Dia = 16.00
Height = 0.30 m Thickness = 0.35 m Bot Bar Dia = 16.00
Soil Properties: Edge to Face Dist = - Fixed Depth = 1.50 m Cover (mm) = 75.00
σall= 158.00 kPa Interior
γ= 18.00 kN/m3 Width = 0.30 m
Height = 0.30 m
Edge to Face Dist = 0.90 Free
Applied forces:
Pu Mx Fx Pu Mx Fx qa
Service kN kN.m kN Factore kN kN.m kN factor
Exterior = 139.59 0.58 17.15 Exterior = 182.70 0.59 28.64 1.33
Interior = 315.07 1.81 17.12 Interior = 401.85 1.03 29.16
3D Zoom In Zoom Out 2D
0.3 m
0.3 m
1.8 m
90 kPa
0.3 m 0.3 m
173.85 kPa 90 kPa
173.85 kPa
2.5 m
Summary Calculations
Check for Soil Pressures (Service Load) Footing Moment Diagram (Factored Load)
150.00
Location Value Unit
100.00
Exterior Footing = 173.85 kPa
Interior Footing = 90.00 kPa 50.00
Ratio 0.83 Safe
0.00
0.00 0.50 1.00 1.50 2.00 2.50
Check for Stability (Service Load)
-50.00
Overturning Sliding Footing Shear Diagram (Factored Load)
400.00
x-x 300.00
x-x
Resisting Overturning 200.00
100.00
670.84 14.39049286 Ratio
0.00
46.62 8.59 0.00 0.50 1.00 1.50 2.00 2.50
-100.00
Safe Safe -200.00
-300.00
Check for Shear Design (Factored Load)
Check Wide Beam Shear Check Punching Shear
-Side +Side Units Exterior Column Unit Interior Column Unit
Exterior Column - 0.06 Mpa Unbalance Moment factor = 0 0
Interior Column 0.05 0.06 Mpa Column Location Factor = 30.00 40.00
Absolute max. Stress = 0.060 MPa ColumnAspect Ratio = 1.00 1.00
Under-strenght φ Factor = 0.75 Actual Punching Stress = 0.53 MPa 0.41 MPa
Allowable Shear Capacity = 0.580 MPa Allowable Shear Capacity = 1.13 Mpa 1.13 Mpa
Ratio 0.103 Safe Ratio 0.47 Safe 0.36 Safe
This spreadsheets is licensed only to Engr. Mark Christian D. Esguerra
Detailed Calculations
Check for Stability (Service Load) Check for Shear (Factored Load)
Overturning about x-x Punching Shear (Exterior Column) Punching Shear Interior Column)
Exterior Column Vu at critical point Vu at critical point
Moment = 0.58 kN-m Point 1 = - kN Point 1 = 214.62 kN
Shear Force = 17.15 kN Point 2 = 16.65 kN Point 2 = 163.50 kN
Total = 6.59 kN-m Average = 8.32 kN Average = 189.06 kN
Interior Column Calculation of unbalanced moment transferred by eccentricity Calculation of unbalanced moment transferred by
Moment = 1.81 kN-m of shear eccentricity of shear
Shear Force = 17.12 kN β= 1.00 ACI [Link].a β= 1.00 ACI [Link].a
Total = 7.80 kN-m αs = 30.00 ACI [Link].b αs = 40.00 ACI [Link].b
Resisting about x-x b1 = 0.56 m b1 = 0.56 m
Footing Weight = 37.80 kN b2 = 0.43 m b2 = 0.56 m
Soil Weight = 116.64 kN bo = 1.42 m bo = 2.24 m
Ext. Axial = 139.59 kN Critical Area = 0.24 mm2 Critical Area = 0.31 mm2
Int. Axial = 315.07 kN Resultant = 8.32 kN Resultant = 189.06 kN
Total = 670.84 kN-m γf = 0.57 x-x ACI [Link] γf = 0.60 x-x ACI [Link]
Ratio 46.62 γv_x = 0.43 x-x ACI [Link] γv_x = 0.40 x-x ACI [Link]
Remark = Safe J/c 1= 0.0788 N/mm2 x-x J/c 1= 0.0977 N/mm2 x-x
Sliding Calculation Vu = 0.53 ACI [Link].a Vu = 0.41 ACI [Link].a
kp = 2.78 φVu = 1.13 ACI [Link].b φVu = 1.71 ACI [Link].b
Pressure mid d = 83.75 kPa Calculation of RC punching shear resistance without shear Calculation of RC punching shear resistance without
Passive Force = 52.76 kN reinforcement (φVn = φVc) shear reinforcement (φVn = φVc)
Friction force = 241.50 kN Vc (N/mm2) = 2.32 ACI [Link].a Vc (N/mm2) = 2.32 ACI [Link].a
2
Safe Factor = 8.59 Vc (N/mm ) = 2.82 ACI [Link].b Vc (N/mm2) = 2.50 ACI [Link].b
Remark = Safe Vc (N/mm2) = 1.50 ACI [Link].c Vc (N/mm2) = 1.50 ACI [Link].c
φVc (N/mm2) = 1.13 φVc (N/mm2) = 1.13
Check for Soil Pressure (Service Load) Ratio = 0.473 Ratio = 0.367
Soil Pressure Remark = Safe for punching shear! Remark = Safe for punching shear!
Footing Weight = 37.80 kN Check for Reinforcement (Factored Load)
Soil Weight = 116.64 kN a b c d e
Resisting Force = 593.65 kN
Eccentricity = 0.13 kN-m
Exterior Footing = 173.85 kPa
f g
Interior Footing = 90.00 kPa
Ratio 0.83 Safe
Check for Shear (Factored Load)
Wide Beam Shear
Shear Forces calculated as the volume of
bearing pressures Longitudinal direction Transverse direction
Section Units
Exterior Column a b c d e f g
-Side - MPa Width = 1.80 1.80 1.80 1.80 1.80 0.56 0.56 m
+Side 0.060 MPa Depth = 0.26 0.26 0.26 0.26 0.26 0.26 0.26 m
Interior Column Mu = 0.00 -19.78 38.53 84.97 83.25 63.63 45.23 kN-m
-Side 0.050 MPa Ru = 0.00 0.18 0.35 0.78 0.77 1.88 1.34 0.00
+Side 0.060 MPa m= 23.59 23.59 23.59 23.59 23.59 23.59 23.59 0.00
Maximum Stress = 0.060 MPa req'd p = - 0.0004 0.0009 0.0019 0.0019 0.0048 0.0034 -
Ultimate Shear Capacity min p = 0.0034 0.0034 0.0034 0.0034 0.0034 0.0034 0.0034 -
Vc = φ0.166λ√f'c - ACI [Link] use p = 0.0034 0.0034 0.0034 0.0034 0.0034 0.0048 0.0034 -
Reduc factor φ = 0.750 As = 1572.72 1572.72 1572.72 1572.72 1572.72 697.36 489.29 mm2
λ= 1.000 req'd n2 = 8 8 8 8 8 4 3 pcs
Vc = 0.580 MPa Use n2 = 9 pcs 9 pcs 9 pcs 9 pcs 9 pcs 4 pcs 3 pcs pcs
Ratio = 0.103 s (mm) = 182.00 mm 182.00 mm 182.00 mm 182.00 mm 182.00 mm 98.67 mm 156.00 mm mm2
Remark = Safe for beam shear! Location Bottom Top Bottom Bottom Bottom Bottom Bottom Location
This spreadsheets is licensed only to Engr. Mark Christian D. Esguerra