RXUQ18AYM RXUQ14AYM
RXUQ20AYM RXUQ16AYM
Automatic refrigerant
Energy savings High reliability
charge function
•Optimised operation efficiency •New inverter PC board
Uniting VRV, VRT and VAV
•Higher installation quality •Double backup operation
technologies
•Easier installation •Refrigerant cooling for PC board
1 2
VRV User Benefits For
Comfortable environment
USERS While operating optimally at low load, VRT
For property smart operation maintains the indoor
OWNERS
First launched in 1982, the Daikin VRV system has been
temperature and ensures a comfortable
providing comfort and reliability to building owners and their environment.
tenants for over 35 years. Leveraging the latest in
BP unit
energy-saving technology, Daikin has further improved
Residential indoor units*
energy savings while reducing space requirements. This Min. sound
level
added value is one reason why Daikin is the right choice for Because indoor units developed for residential use can be connected, it 19 dB(A)
is possible to realise quiet operation.
building owners.
You can include indoor units that operate at min.19 dB(A), and to reduce
the noise of refrigerant passing through the piping by remotely installing
Energy saving & an BP unit.
*For indoor units connectability, please refer to the indoor unit product lineups.
comfortable environment
Based on the idea of using only as much space as
Max. total
absolutely required, Daikin first launched its
For Varied lineup of models
piping length
CONSULTANT
commercial multi-split air conditioning systems in 1982. 1000 m
OFFICES
comfortable airflow is ensured in every space. outdoor units
ensure thermal loading is generally low, thus boosting 190 m and the indoor
units
energy efficiency. This greatly reduces the amount of
Long piping provides more
90 m
energy required for building air conditioning.
3 4
X SERIES New Heights in Energy Efficiency During Actual Operation
Advanced technologies
for greater energy savings VRV + VRT + VAV
By uniting advanced software and hardware technologies for greater energy savings during
actual operation and combining the technologies of VRV, VRT and VAV, we have attained
RXUQ-A
both energy savings and comfortable air conditioning.
Software
VRT Smart Control (Fully A utomatic Energy-sav ing Ref rigerant Cont r ol)
technology
Cooling Only Optimally supply only for the needed capacity of indoor units
Daikin developed VRT smart control by combining air volume control (VAV: Variable Air Volume)
6 HP - 60 HP for indoor units with conventional VRT control, which optimises compressor speed by
calculating the required load for the entire system and optimal target refrigerant temperature
(16 kW) (168 kW) based on data sent from each indoor unit. Coordination with the air volume control reduces
compressor load and minimises operation loss based on detailed control. VRT smart control
ensures energy savings and comfortable air conditioning to meet actual operating conditions. VRT Smart
Control
Function
movie
Different automatic energy-saving refrigerant control applies depending on the indoor units connected.
Greater energy savings during low-load operation Subject to VRT smart control
Target indoor units
Subject to VRT control
1
Temperature
data received
from indoor units
The key to innovative energy •Correlation between the load factor for the rated capacity and operation time
Coordin a t e d con tr ol
*According to a survey by Daikin (based on Air Conditioning Network Service System data)
2
Select the target
3
•Indoor fan air volume
Operation period
0 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Temperature
Room temperature setting
Turned off by Turned off by Turned off by
Load factor for the rated capacity the thermostat the thermostat the thermostat
*Graph shown above is for illustration purposes only.
Note:
25–26.
•If a system has indoor units subject to both VRT smart and VRT control, the system is operated under VRT control.
•If a system has both outdoor-air processing air conditioners and outdoor-air processing type indoor units, VRT smart control and VRT control are disabled.
Annual power
consumption
Optimum utilisation of VRT Smart Control and VRT Control
COP for 10 HP 20%* lower Effectiveness can be demonstrated for VRT Smart Control and VRT Control when all the indoor units operate under low load conditions in
a similar manner.
* Simulation conditions :
8.84 Low load conditions are the time when room temperature approaches set temperature.
9 8.42 8.19 • Location : Bangkok, Thailand
• System : Outdoor unit (10 HP) x 1 For this reason, please note the following to maximise energy .
Cooling Operation COP
55 66
New Heights in Energy Efficiency During Actual Operation
Available on Hardware
New Scroll Compressor all models technology Advanced oil temperature control
Standby power consumption is reduced
Refrigerant leakage is minimised during low-load operation.
The advanced oil temperature control reduces standby power consumption by up to 65.4%* annually compared to
Operation loss due to refrigerant leakage is reduced by the proprietary
conventional models. Standby power needed for preheating refrigerator oil, which consumed substantial standby power, was
back pressure control mechanism to ensure stable low-load operation.
reduced to save energy when the air conditioner is stopped.
* Operation calculation conditions: VRV X series 14 HP
New compressor Location: Singapore
Conventional compressor New Scroll Operation time: 08:00–18:00 on weekdays
Compressor
movie
6 HP 8 HP 10 HP 12 HP 14 HP 16 HP 18 HP 20 HP
Cooling operation conditions : Indoor temp, of 27°CDB, 19°CWB, and outdoor temp, of 35°CDB.
VRV IV
High-COP type (18 HP) X SERIES (18 HP)
The force pressing the The intermediate pressure COP 4.40 4.54 3% Increase
movable scroll decreases keeps pressing the movable
during low-load operation. scroll during low-load operation.
Installation space 2.13 m 2 1.66 m 2 22% Decrease
2,790 mm 400 kg 28% Decrease 2,170 mm
Product weight 555 kg
765 mm 765 mm
Intermediate pressure
adjustment port
7 8
7 8
Excellent Operational Performance
1 2 3 4 5
Calculate necessary Recalculate refrigerant Charge refrigerant Regularly check refrigerant Complete by manually
refrigerant amount from weight on weighing scale closing valves when proper Illustrated fan
design drawing installation drawing weight is reached
X SERIES
1 2 3 Automatic completion by proper
refrigerant amount
Calculation of necessary Pre-charge of refrigerant* Start of automatic
refrigerant amount from refrigerant charge operation
design drawing Monitoring refrigerant charging is
unnecessary Nighttime quiet operation function
No recalculation of charge amounts due For areas where there are stringent limitations to sound levels, the outdoor unit sound
to minor design changes locally level can be reduced during the nighttime, to meet the requirement.
High reliability Conventional inverter New inverter PC board 100% 8 hrs 9 hrs
99 10
Cloud Connection Ready Refined Design Meets Advanced Technologies
FAULT MANAGEMENT
Minimize downtime and strengthen preventive maintenance
by its real-time diagnostic data and predictive analytics.
W breakdown, preventing
O
11 12
Flexible
Refined System
Design Design
Meets AAdvanced
SERIES Technologies
A SERIES Reliable and Stable System
Positive
Eliminate suction More accurate test operation and stable system
electrical component
and residential indoor units pressure space resistance issue Efficient automatic test operation Automatic check
The VRV X series is designed with Without affecting the fan Wiring
Daikin VRV X series check
the electrical box strategically volume, the electric
function, not only greatly accelerating the installation process, but effectively
positioned between a region VRV:VRV
of indoor unit components are designed to
VRV A SERIES
positive and negative pressure. This
RA:Residential indoor unit be at the top and this ulitises Piping
dead space. This eliminates Automatically checks the wirings between outdoor units and indoor units check
negative pressure to positiveBetween BP unit the problem of suction
and indoor unit Negative pressure
pressure due to the high pressure space resistance.
difference.
BP unit Max. 15 m Even Stop valve
negative Automatically checks whether the stop valve in each outdoor unit is in check
pressure
space normal status to ensure the smooth operation of air conditioning system.
High pressure since Max. level
RA RA air enters near the fan difference
15 m
I-demand function
outdoor unit If the outdoor unit is above. 50 m
only residential indoor units are connected,
or unit If the outdoor unit is below. 40 m connection ratio must be 50% to 130%.
range up to 49℃
outdoor unit and the BP unit 40 m Refer to page 46 for outdoor unit
Note: When outdoor temperature falls below 10℃, the thermostat shuts OFF,
with low energy ef t the outdoor unit stops, and operation switches from cooling to fan
Time
operation.
15
17 13 40 16
14
Flexible
Outdoor System DesignSystem Design
Flexible
Unit Lineup
Unit backup operation function Compressor backup operation function 190 m 190 m 90 m 2
Single Outdoor Units Double Outdoor Units
If one of the units in a multiple outdoor system The outdoor unit is equipped with two compressors. Even Max.
Max. level
level difference
difference Max. level differen
6, 8 HP 10, 12,and
Between 14, 16,farthest
the first indoor 12, 14, 16 HP 18, 20, 22 HP 22, 24, 26, 28, 30, 32, 34, 36,
malfunctions, the other outdoor units provide if one compressor malfunctions, the other compressor branch
branch and the
the farthest branch andbetween
between the
the indoor
the farthest indoor between the indo
emergency operation until repairs can be made. provides emergency operation, reducing the risk of air 18, 20indoor
HP unit
indoor unit indoor unit units
units 38, 40 HP units
Emergency
operation Malfunction Actual piping length (Equivalent) Actual piping length (Equivalent) 165 m (190 m)
Total piping
Actual pipinglength
length (Equivalent) Total piping length 165 m (190 m) 1000 m
RXUQ6AYM
Maximum RXUQ10AYM
allowable piping length RXUQ12AMYM RXUQ18AMYM
Maximum allowable piping length RXUQ22AMYM RXUQ32AMYM
RXUQ8AYM RXUQ12AYM Total piping length
RXUQ14AMYM RXUQ20AMYM RXUQ24AMYM 90 m m1
RXUQ34AMYM
1000
Maximum allowable piping length
RXUQ14AYM Between RXUQ16AMYM
Between the
the outdoor
first branch
indoor andand
branch lastRXUQ22AMYM-SG
thethe outdoor
farthest unit (Equivalent)
indoor unit RXUQ24AMYM-SG
Between the outdoor branch RXUQ36AMYM
1090
and the last
mm (13
outdoor
1 m) unit (Equivalent)
200% 200%
For more information, please contact Daikin sales office.
Double outdoor units Double outdoor units 160%
With this smart connection, pipes can be joined easily and quickly RXUQ20AM1YM RXUQ44AMYM
Capacity index of the outdoor units
RXUQ52AMYM
outdoor units.
Capacity index
RXUQ60AMYM
of the outdoor units
RXUQ32AMYM-SG
outdoor units.
Note: Note:
without brazing or using any special tools. Only a wrench is required. RXUQ46AMYM RXUQ54AMYM RXUQ34AMYM-SG
indoor units. indoor units.
It meets the stringent requirements in terms of safety and leak New VRV with RXUQ48AMYM *Refer RXUQ56AMYM
to page 19 for outdoor unit combination details. RXUQ36AMYM-SG
*Refer to page 46 for outdoor unit combination details.
tightness while providing substantial benefits. RXUQ38AMYM-SG
RXUQ40AMYM-SG
15
17 13 39 16 16
18 20
Flexible
A SERIES System Design Outdoor Unit Lineup
VRV A SERIES
Automatic
RA:Residential indoor unitFor Automatic
connection of only VRVRA:Residential
indoor units indoor unit The single outdoor unit has only 2 different shapes and dimensions, not only simplifying the design process,
or sequencing sequencing Between the outdoor but also bringing the system flexibility to a new level.
t branch and the last
Total capacity index of the indoor units
Between BP unit Connection ratio =Between BP unit outdoor unit With the outdoor unit capacity increased in increment of 2 HP, customers' needs can be precisely met.
Max. level difference
Priority: between the outdoorand indoor unit Priority: Priority:
Capacity
and indoor unit index of the outdoor units Max. 13 m
unit and the BP units
BP unitequivalent
Max.
Max. 15 m BP unit Max.
Max. total piping 15
length m
1000 m
piping length
40 m Lineup
120 mof VRV indoor unit connection capacity
Double backup operation functions
Conditions Max. level Max. level HP 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60
Max. level
RA RA difference differenceRA RA difference
15 m between 15 m between the between the Single outdoor units
BP unitApplicable BP unit outdoor BPunitunit
and Other VRV indoor
outdoor unit and
Daikin
VRVVRV X series
indoor units outdoor unit boasts
thedouble
indoor unitbackup operation functions, unit models* which the
can secure
indoor unit the use of
1 air VRV X SERIES Double outdoor units
conditioners in this area to the greatest
Max. level
extent
FXDQ, 50 m
FXSQ, in an emergency
FXMQ-PA, FXAQ, by enabling
FXB(P)Q models double backup
Max. level 50 m operation
functions even if failure occurs Triple outdoor units
levelinbetween
difference a set of air conditioning equipment. difference between
RA RA
Singleindoor branch
outdoor and
units Max. 200%
200%
VRV the indoor units the indoor units
In the event
the of a
farthest
RA failure,
indoor unit
emergency
difference operation can be conveniently
Max. equivalentenabled to allow the remaining system to
RA
the BP Double outdoor units
operate in a limited1 fashion. between the BP
unit and15them
piping length 15 m 160%
Triple Max. 50units
outdoor m indoor unit 130%
Unit backup operation function Compressor
190 m backup operation function
*1 For the FXF(S)Q25 and FXVQ models, 5m maximum connection ratio is 130% for the entire range of outdoor units. Single Outdoor Units Double Outdoor Units
x. level difference If one of the units in a multiple outdoor system The outdoor unit is equipped with two compressors. Even Max. level differ
Note: If the operational capacity of indoor units is more than 130%, low airflow operation is enforced in all the indoor units. 6, 8 HP 10, 12, 14, 16, 12, 14, 16 HP 18, 20, 22 HP 22, 24, 26, 28, 30, 32, 34, 36,
ween the indoor malfunctions, the other outdoor
*Refer to page 24 for outdoor unit combination details.units provide if onebranch
compressor malfunctions, the other compressor
and the farthest between the indoor
units
emergency operation until repairs can be made.
indoor unit
provides emergency operation, reducing the risk of air
units 18, 20 HP 38, 40 HP
30 m VRV composed of two or more outdoor units.
* For systems VRV
conditioning 90 m 1 due to compressor failure.
Max.shutdown 30 m
Note: The above is just a schematic diagram. Note: The above is just a schematic diagram.
(Capacity is saved during backup operation.)
High external static pressure * For single outdoor unit system RXQ16-20AYM models. On-site settings are
required using the printed circuit board of the outdoor unit.
and residentialWhen indoor units iscombination of VRV and residentialEmergency
a mixed
Malfunction indoor units is
al indoor units are VRV X
connected
connected or when only residential indoor units are operation
connected
e: The above is just a dissipation
schematic diagram.
and stable Actual
operation Note: The above is just a schematic diagram.
piping of equipment
length (Equivalent)in either hierarchical or intensive arrangement.
100 m (120 m)
branch and BP unit or VRV indoor unit is branch and BP unit or VRV indoor unit is
Total piping length Emergency
over 20 m, it is necessary to increase the gas 250 m over 20 m, it is necessary to increase the gas
Between BP unit If indoor unit capacity index < 60. operation 2 m–15 m Actual piping length (Equivalent) Malfunction
Maximum allowable indoor branch and BP unit or VRV indoor indoor branch and BP unit or VRV indoor
and indoor unit If indoor unit capacity index is 60 and 71. 2 m–8 m
piping length unit. If the piping diameter of the sized up unit.length
Total piping If the piping diameter of the sized up
Maximum allowable piping length RXUQ6AYM RXUQ10AYM RXUQ12AMYM RXUQ18AMYM RXUQ22AMYM RXUQ32AMYM
78.4 Pa
piping exceeds the diameter of the piping piping exceeds the diameter of the piping
50 m 1 RXUQ8AYM RXUQ12AYM RXUQ14AMYM RXUQ20AMYM RXUQ24AMYM RXUQ34AMYM
VRV indoor unit
latter also requires a liquid piping and gas Betweenlatter also requires a liquid piping
last and gas unit (Equivalent)
ivalent)
5 m
the outdoor branch and the outdoor RXUQ14AYM RXUQ16AMYM RXUQ22AMYM-SG RXUQ24AMYM-SG RXUQ36AMYM
Ease of Maintenance
piping size up. Please refer to Engineering piping size up. Please refer to Engineering
More options inthe
theindoor
opening/angle of for
louvre BetweenData
the outdoor
Book forunits (Multiple use) RXUQ16AYM RXUQ26AMYM RXUQ38AMYM
Between units Data Book details. 15 m details.
Outstanding heat RXUQ18AYM RXUQ28AMYM RXUQ40AMYM
Between BP dissipation
units effect
*When in
a mixed both
Maximum allowable
combination level
of VRV anddifference15 m Between*When the indoor
a mixedunits
combination of VRV and
VRV X serieshierarchical
provides aand
maintenance feature* which allows RXUQ20AYM RXUQ30AMYM
intensive arrangement above. the shutdown 50 mof indoor unit without shutting down
residential indoor units is connected or when Betweenresidential
the outdoor indoor
unitsunits
and is connected
the indoor or when
units
Maximum allowable Between the outdoor unit If the outdoor unit is
only residential indoor units are connected, only residential indoor units are connected,
ons. The the
level whole VRV
difference system.
and This
the indoorfeature
unit comes in handy
If the outdoor
connection 1. No unit during
mustisbe
ratiospecial below. maintenance
requirements up to 40 m. 40
50% to 130%. period as the
Themmaximum actual remaining
connection ratio must
piping length indoor
can bebe9050% units
m, to 130%. on conditions. The
depending
continue
or details of these conditions to operate.Between the outdoor unit and
and requirements. Refer thetoBP
page
unit46 for outdoor
lessening unit from conventional
the conditions ReferBe
40 m VRV IV models. to sure
pageto19refer
for outdoor unit
to the Engineering Data Book for details of these conditions and requirements.
he outdoor unit combination details.
2. When level differences are 50 m or more, the diameter combination details.
of the main liquid piping size must be increased. If the outdoor unit Triple Outdoor Units
nformation. Between the BP unit and the indoor unit
on the outdoor unit is required. Refer to 5mthe Engineering Data Book and contact your local dealer for more information.
18, 20 HP 42, 44, 46, 48, 50, 52, 54, 56, 58, 60 HP 30, 32, 34, 36, 38, 40 HP
tic pressure
High external static pressure
Connection capacity at maximum is 200%. Applicable
Area A Area B Area C
VRV indoor units
FXMQ-PA, FXAQ, FXB(P)Q
VRV models
* FieldXsetting
seriesis outdoor
required. unit has been Connection ratio FXD(S)Q, FXSQ, FXMQ-PA,
78.4 Pa 78.4 Pa
This feature does not applystatic
to residential indoorup
unittoconnection.
ssure up to achieved high external pressure 50%–200% Single outdoor units
17 39 40 14 16 18 20
X SERIES
A
Outdoor Unit
Unit Combinations
Unit Combinations
Outdoor Combinations
VRV X SERIES
ndoor
indoorunits only
unitsFor
only
connection
Capacityof VRV indoor units only
Outdoor unit multi
Total capacity index of Maximum number of For mixed combination of VRV and residential indoor units or connection of
Outdoor
Outdoor unit
unit multi
multi Total capacity
Total capacity index
index of
of Maximum
Maximum number
number of
Outdoor
of unit multi
residential indoor units only
Combination
Combination Capacity connection piping 1 connectable indoor units*22 connectable indoor units*2
2 Total capacity index of con- Maximum number of Tick
HP kW index
connection piping kit*
Model name kit*1 connectable Combination
indoor connection
units* connectable indoor units* piping nectable indoor units*2 connectable indoor units*2 Ratings
kit*1 Total capacity index of connectable indoor units*2
RXUQ6A –– 75 to
to 195
195 (300)
(300) 9 (15)
(15)
VRV A SERIES
6RXQ6A
HP 16.0 150 RXUQ6A 75 RXUQ6A 9 – 75 to 195 (300) 9 (15) 5 Capacity Maximum number of Tick
RXUQ8A – 100 to 260 (400) 13 (20) Model name *1
kW HP Combination (%)*2
connectable indoor units ratings
8RXQ8A
HP 22.4 200 RXUQ8A– 100 to 260 (400)
RXUQ8A 13 (20) – 100 to 260 (400) 13 (20) 4 index
16 (25)
(25) 50% 100% 130%
RXUQ10A
10 HP 28.0
RXQ10A 250 RXUQ10A –– 125
125 toto 325
325 (500)
RXUQ10A
(500) 16 – 125 to 325 (500) 16 (25) 4
19 (30)
(30) RXUQ6AYM 16.0 6 150 75 150 195 9 5
RXUQ12A
12 HP 33.5
RXQ12A 300 RXUQ12A –– 150
150 toto 390
390 (600)
RXUQ12A
(600) 19 – 150 to 390 (600) 19 (30) 4
14 HP
RXUQ14A 40.0 350 RXUQ14A – 175 to 455RXUQ14A
(700) 22 (35) – 175 to 455 (700) 22 (35) 3 RXUQ8AYM 22.4 8 200 100 200 260 13 5
RXQ14A – 175 to 455 (700) 22 (35)
16 HP 45.0
RXUQ16A 400 RXUQ16A – 200 to 520RXUQ16A
(800) 26 (40) – 200 to 520 (800) 26 (40) 3 RXUQ10AYM 28.0 10 250 125 250 325 16 5
RXQ16A – 200 to 520 (800) 26 (40)
18 HP 50.0 450 RXUQ18A RXUQ18A – 225 to 585 (900) 29 (45) 2 RXUQ12AYM 33.5 12 300 150 300 390 19 4
RXUQ18A
RXQ18A –– 225
225 toto 585
585 (900)
(900) 29 (45)
29 (45)
20 HP 56.0 500 RXUQ20A RXUQ20A – 250 to 650 (1,000) 32 (50) 3 RXUQ14AYM 40.0 14 350 175 350 455 22 3
RXUQ20A
RXQ20A –– 250
250 to
to 650
650 (1,000)
(1,000) 32 (50)
32 (50)
12 HP 32.0 300 RXUQ12AM RXUQ6A + RXUQ6A 150 to 390 (480) 19 (24) RXUQ16AYM 45.0 16 400 200 400 520 26 3
RXUQ6A
RXQ8A14 HP++RXQ10A
RXUQ6A
38.4 350 RXUQ14AM 150 to
to 390
585 (480)
225 RXUQ6A (720)
+ RXUQ8A 19 (36)
29 (24) 175 to 455 (560) 22 (28) RXUQ18AYM 50.0 18 450 225 450 585 29 2
RXUQ6A
RXQ8A16 HP++RXQ12A
RXUQ8A
44.8 400 RXUQ16AM 175 to
to 455
650 (560)
250 RXUQ8A (800)
+ RXUQ8A 22 (40)
32 (28) BHFP22P100 200 to 520 (640) 26 (32) RXUQ20AYM 56.0 20 500 250 500 650 32 3
RXUQ8A
RXQ10A18 HP +
+ RXUQ8A50.4
RXQ12A 450 BHFP22P100
RXUQ18AM 200 to
to 520
275RXUQ8A715 (640)
+ RXUQ10A
(880) 26 (44)
35 (32) 225 to 585 (720) 29 (36)
20 HP Note: *1. Only single outdoor unit (RXUQ6-20AYM) can be connected.
RXUQ8ARXQ12A × 55.9
+ RXUQ10A 2 500 RXUQ20AM 225RXUQ8A
300 to 780
to + RXUQ12A
585 (960)
(720) 29 (48)
39 (36) 250 to 650 (800) 32 (40)
*2. Total capacity index of connectable indoor units must be 50%–130% of the capacity index of the outdoor unit.
RXUQ8A 18 HP 48.0 450 RXUQ18AM1 RXUQ6A
(800) × 3 32 (52)
(40) BHFP22P151 225 to 585 (585) 29 (29)
RXQ12A++RXUQ12ARXQ14A 250toto845
325 650(1,040) 42
20 HP × 54.4
RXUQ6A 3 500 RXUQ20AM1 RXUQ6A
225 × 2 + RXUQ8A 29 (29) 250 to 650 (650) 32 (32)
RXQ12A + RXQ16A 350 toto910
585(1,120)
(585) 45 (56)
22 HP 61.5 550 BHFP22P151
RXUQ22AM
BHFP22P100 RXUQ10A + RXUQ12A 275 to 715 (880) 35 (44)
RXUQ6A
RXQ12A ×+ 2+ RXUQ8A
RXQ18A 250toto975
375 650(1,200)
(650) 32 (60)
48 (32)
22 HP 62.4 550 RXUQ22AM-SG RXUQ8A + RXUQ14A 275 to 715 (880) 35 (44)
RXUQ10A
RXQ14A +
+ RXUQ12A
RXQ18A 275
400 toto 715 (1,280)
1,040 (880) 35 (64)
52 (44)
24 HP 67.0 600 RXUQ24AM RXUQ12A × 2 300 to 780 (960) 39 (48)
RXUQ12A
RXQ16A24 HP ×
+ RXQ18A 2
68.0 600 RXUQ24AM-SG 300
425 to to 780 (960)
1,105 (1,360)
RXUQ10A 39
+ RXUQ14A 55 (64) (48) 300 to 780 (960) 39 (48)
RXUQ12A
RXQ18A + RXUQ14A
26 HP × 73.5 2 650 RXUQ26AM 325 to 845
RXUQ12A
450 to (1,040) 42
+ RXUQ14A 58 (64)
1,170 (1,440) (52) 325 to 845 (1,040) 42 (52)
RXUQ12A28 HP+
RXQ18A + RXQ20A 78.5
RXUQ16A 700 RXUQ28AM 350 RXUQ12A
to 910 +
(1,120)
475 to 1,235 (1,520) RXUQ16A 45 (56)
61 (64) 350 to 910 (1,120) 45 (56)
BHFP22P100
RXUQ12A30 HP + 83.5
RXUQ18A 750 RXUQ30AM 375 RXUQ12A
to 975 + RXUQ18A 48 (60)
(1,200) 375 to 975 (1,200) 48 (60)
RXQ20A × 2 500 to 1,300 (1,600)
32 HP 89.5 800 BHFP22P100
RXUQ32AM RXUQ12A + RXUQ20A 52 (64) 400 to 1,040 (1,280) 52 (64)
RXUQ12A
RXQ12A ×+ 2+ RXUQ20A
RXQ18A 400 to
525 to 1,040 (1,365)
1,365 (1,280)
34 HP 96.0 850 RXUQ34AM RXUQ14A + RXUQ20A 425 to 1,105 (1,360) 55 (64)
RXUQ14A
RXQ12A + RXUQ20A 425 to
to 1,430
1,105 (1,430)
(1,360) 55 (64)
36×HP 2+ RXQ20A
101 900 RXUQ36AM 550 RXUQ16A + RXUQ20A 450 to 1,170 (1,440) 58 (64) Refer to
RXUQ16A
RXQ14A + RXUQ20A 450 to 1,170 (1,440) 58 (64)
38×HP 2 + RXQ18A
106 950 RXUQ38AM 575 to 1,495 (1,495)
RXUQ18A + RXUQ20A 475 to 1,235 (1,520) 61 (64) individual
RXUQ18A
RXQ14A + 40 +
RXQ16A
HP + RXUQ20A
112RXQ18A1,000 RXUQ40AM 475 to 1,235
600 to 1,560 (1,520)
(1,560)× 2
RXUQ20A 61 (64) 500 to 1,300 (1,600) 64 (64) models
RXQ14ARXUQ20A
30+HP RXQ18A ×84.0
2 × 2 750 RXUQ30AM -SG 500 to
RXUQ6A
625 to 1,625
1,300 (1,600) + RXUQ14A
+ RXUQ10A
(1,625) 64 (64)
64 (64) 375 to 975 (975) 48 (48)
BHFP22P151
RXUQ12A
RXQ16A 32+×HP 89.4× 2 800
2 + RXUQ18A
RXQ18A RXUQ32AM -SG RXUQ8A
525 to
650 + RXUQ12A
to 1,690
1,365 (1,365) + RXUQ12A
(1,690) 400 to 1,040 (1,040) 52 (52)
RXUQ12A 34×HP
RXQ18A 95.9
2 + ×RXUQ20A
3 850 RXUQ34AM -SG RXUQ8A
550 to
675 + RXUQ12A
to 1,755
1,430 (1,430) + RXUQ14A
(1,755) 425 to 1,105 (1,105) 55 (55)
RXUQ12A 36 HP
+ RXUQ14A 99.5 900
+ RXUQ20A RXUQ36AM -SG RXUQ6A
575 to +
to 1,820RXUQ12A
(1,495) + RXUQ18A
1,495 (1,820) 450 to 1,170 (1,170) 58 (58)
RXQ18A × 2 + RXQ20A 700
38 HP 106 950 RXUQ38AM -SG RXUQ6A + RXUQ12A + RXUQ20A 475 to 1,235 (1,235) 61 (61)
RXUQ12ARXQ18A+ RXUQ16A
+ RXQ20A + RXUQ20A
×2 600 to
725 to 1,885
1,560 (1,885)
(1,560)
40 HP 112 1,000 RXUQ40AM -SG RXUQ6A + RXUQ14A + RXUQ20A 500 to 1,300 (1,300)
RXUQ12A +RXQ20ARXUQ18A × 3 + RXUQ20A 625 to
750 to 1,950
1,625 (1,950)
(1,625)
42 HP 117 1,050 RXUQ42AM
BHFP22P151 RXUQ12A × 2 + RXUQ18A 64 (64) 525 to 1,365 (1,365)
RXUQ12A 44+HP
or unit multi connection piping
RXUQ20A 123 × 21,100
kit (separately RXUQ44AM
sold) is required.
650 to 1,690 (1,690)
RXUQ12A × 2 + RXUQ20A 550 to 1,430 (1,430)
RXUQ14A BHFP22P151
n connection of 46+HP
indoor units RXUQ20A
rated at130 × 21,150
maximum capacity,RXUQ46AM 675units,
200% for single outdoor
RXUQ12Ato 1,755
160%
+ (1,755)
for double
RXUQ14A outdoor units, and
+ RXUQ20A 575 to 1,495 (1,495)
r to page 39 for notes on connection capacity of indoor units.
RXUQ16A 48+HP RXUQ20A 135 × 21,200 RXUQ48AM 700 to 1,820
RXUQ12A (1,820) + RXUQ20A
+ RXUQ16A 600 to 1,560 (1,560)
RXUQ18A 50+HP RXUQ20A 140 × 21,250 RXUQ50AM RXUQ12A
725 to 1,885+ RXUQ18A
(1,885) + RXUQ20A 625 to 1,625 (1,625) 64 (64)
52 HP ×146
RXUQ20A 3 1,300 RXUQ52AM 750RXUQ12A + RXUQ20A × 2
to 1,950 (1,950) 650 to 1,690 (1,690)
54 HP 152 1,350 RXUQ54AM RXUQ14A + RXUQ20A × 2 675 to 1,755 (1,755)
unit multi connection piping kit (separately sold) is required.
n of VRV and residential indoor units or connection of
56rated
connection of indoor units HP at 157 maximum 1,400 RXUQ56AM
capacity, 200% RXUQ16A
for single outdoor units, 160% + forRXUQ20A × 2 units, and
double outdoor 700 to 1,820 (1,820)
to page 21 for notes on connection
58 HP 162 capacity1,450
of indoor units.
RXUQ58AM RXUQ18A + RXUQ20A × 2 725 to 1,885 (1,885)
s only 60 HP 168 1,500 RXUQ60AM RXUQ20A × 3 750 to 1,950 (1,950)
of VRV andNote:
residential
Total
*1. For capacity
multiple
indoor unitsunitor
index of connectable
connection, the outdoorindoor
connection
units
multi
*2 of
connection piping kit (separately sold) is required.
Capacity Maximum number of
s only index Combination
*2. Values inside brackets (%) on connection of indoor units rated at maximum capacity, 200% for single outdoor units, 160% for double outdoor units, and
are based
*2
connectable indoor units
130%
50% for triple outdoor units. Refer to page130%
100% 16 for notes on connection capacity of indoor units.
*2
150 Total
75 capacity index of150 connectable indoor units
195 9
Capacity Maximum number of
200 100 Combination
200 (%)*2 260 13indoor units
index connectable
250 50%
125 100%
250 130%
325 16
150
300 75
150 150
300 195
390 9
19
200
350 100
175 200
350 260
455 13
22
250
400 125
200 250
400 325
520 16
26
300
450 150
225 300
450 390
585 19
29
350
500 175
250 350
500 455
650 22
32
400 200 400 520 26
AYM(W)) can be connected.
450 225 450
ndoor units must be 50%–130% of the capacity index of the outdoor unit. 585 29
500 250 500 650 32
0AYM(W)) can be connected.
ndoor units must be 50%–130% of the capacity index of the outdoor unit.
19 46
28 20
VRV X Series Outdoor Units RXUQ-A
MODEL RXUQ6AYM RXUQ8AYM RXUQ10AYM RXUQ12AYM RXUQ14AYM RXUQ16AYM RXUQ18AYM RXUQ20AYM RXUQ12AMYM* RXUQ14AMYM* RXUQ16AMYM*
— — — — — — — — RXUQ6AYM RXUQ6AYM RXUQ8AYM
Combination units — — — — — — — — RXUQ6AYM RXUQ8AYM RXUQ8AYM
— — — — — — — — — — —
Power supply 3-phase 4-wire system, 380-415 V/380 V, 50/60 Hz 3-phase 4-wire system, 380-415 V/380 V, 50/60 Hz
Btu/h 54,600 76,400 95,500 114,000 136,000 154,000 171,000 191,000 109,000 131,000 153,000
Cooling capacity
kW 16.0 22.4 28.0 33.5 40.0 45.0 50.0 56.0 32.0 38.4 44.8
Power consumption kW 3.23 4.82 6.29 7.81 9.46 11.4 12.8 14.8 6.46 8.05 9.64
Capacity control % 23-100 19-100 13-100 12-100 11-100 9-100 7-100 11-100 10-100 9-100
Casing colour Ivory white (5Y7.5/1) Ivory white (5Y7.5/1)
Type Hermetically sealed scroll type Hermetically sealed scroll type
Compressor
Motor output kW 2.4×1 3.4×1 4.2×1 5.2×1 (3.4×1)+(2.9×1) (3.4×1)+(3.9×1) (3.7×1)+(4.3×1) (4.9×1)+(4.2×1) (2.4×1)+(2.4×1) (2.4×1)+(3.4×1) (3.4×1)+(3.4×1)
Airflow rate m3/min 119 178 191 218 218 268 297 119+119 119+178 178+178
Dimensions (H×W×D) mm 1,657×930×765 1,657×1,240×765 1,657×1,240×765 (1,657×930×765)+(1,657×930×765)
Machine weight kg 185 215 275 275 291 185+185
Sound level dB(A) 54 56 58 59 59 62 65 57 58 59
Operation range ℃DB 10 to 49 10 to 49
Type R-410A R-410A
Refrigerant
Charge kg 6.4 6.6 8.3 8.5 9.7 9.8 11.7 6.4+6.4 6.4+6.6 6.6+6.6
Piping Liquid mm φ9.5 (Brazing) φ12.7 (Brazing) φ12.7 (Brazing) φ15.9 (Brazing) φ12.7 (Brazing)
connections Gas mm φ19.1 (Brazing) φ22.2 (Brazing) φ28.6 (Brazing) φ28.6 (Brazing)
MODEL RXUQ18AMYM* RXUQ20AMYM* RXUQ18AM1YM* RXUQ20AM1YM* RXUQ22AMYM* RXUQ22AMYM-SG* RXUQ24AMYM* RXUQ24AMYM-SG* RXUQ26AMYM* RXUQ28AMYM* RXUQ30AMYM*
RXUQ8AYM RXUQ8AYM RXUQ6AYM RXUQ6AYM RXUQ10AYM RXUQ8AYM RXUQ12AYM RXUQ10AYM RXUQ12AYM RXUQ12AYM RXUQ12AYM
Combination units RXUQ10AYM RXUQ12AYM RXUQ6AYM RXUQ6AYM RXUQ12AYM RXUQ14AYM RXUQ12AYM RXUQ14AYM RXUQ14AYM RXUQ16AYM RXUQ18AYM
— — RXUQ6AYM RXUQ8AYM — ― — — — — —
Power supply 3-phase 4-wire system, 380-415 V/380 V, 50/60 Hz 3-phase 4-wire system, 380-415 V/380 V, 50/60 Hz
Btu/h 172,000 191,000 164,000 186,000 210,000 213,000 229,000 232,000 251,000 268,000 285,000
Cooling capacity
kW 50.4 55.9 48.0 54.4 61.5 62.4 67.0 68.0 73.5 78.5 83.5
Power consumption kW 11.1 12.6 9.69 11.3 14.1 14.3 15.6 15.8 17.3 19.2 20.6
Capacity control % 8-100 7-100 8-100 7-100 6-100 7-100 6-100 5-100
Casing colour Ivory white (5Y7.5/1) Ivory white (5Y7.5/1)
Type Hermetically sealed scroll type Hermetically sealed scroll type
Compressor
Motor output kW (3.4×1)+(4.2×1) (3.4×1)+(5.2×1) (2.4×1)+(2.4×1)+(2.4×1) (2.4×1)+(2.4×1)+(3.4×1) (4.2×1)+(5.2×1) (3.4×1)+(3.4×1)+(2.9×1) (5.2×1)+(5.2×1) (4.2×1)+(3.4×1)+(2.9×1) (5.2×1)+(3.4×1)+(2.9×1) (5.2×1)+(3.4×1)+(3.9×1) (5.2×1)+(3.7×1)+(4.3×1)
Airflow rate m3/min 178+178 178+191 119+119+119 119+119+178 178+191 178+218 191+191 178+218 191+218 191+218 191+268
(1,657×930×765)+(1,657×930×765)+ (1,657×1,240×765)+ (1,657×930×765)+
Dimensions (H×W×D) mm (1,657×930×765)+(1,657×1,240×765)
(1,657×930×765) (1,657×1,240×765) (1,657×1,240×765)
(1,657×1,240×765)+(1,657×1,240×765)
25 21 22 26
MODEL RXUQ30AMYM-SG* RXUQ32AMYM* RXUQ32AMYM-SG* RXUQ34AMYM* RXUQ34AMYM-SG* RXUQ36AMYM* RXUQ36AMYM-SG* RXUQ38AMYM* RXUQ38AMYM-SG* RXUQ40AMYM* RXUQ40AMYM-SG*
RXUQ6AYM RXUQ12AYM RXUQ8AYM RXUQ14AYM RXUQ8AYM RXUQ16AYM RXUQ6AYM RXUQ18AYM RXUQ6AYM RXUQ20AYM RXUQ6AYM
Combination units RXUQ10AYM RXUQ20AYM RXUQ12AYM RXUQ20AYM RXUQ12AYM RXUQ20AYM RXUQ12AYM RXUQ20AYM RXUQ12AYM RXUQ20AYM RXUQ14AYM
RXUQ14AYM — RXUQ12AYM — RXUQ14AYM — RXUQ18AYM — RXUQ20AYM — RXUQ20AYM
Power supply 3-phase 4-wire system, 380-415 V/380 V, 50/60 Hz 3-phase 4-wire system, 380-415 V/380 V, 50/60 Hz
Btu/h 287,000 305,000 305,000 328,000 327,000 345,000 339,000 362,000 362,000 382,000 382,000
Cooling capacity
kW 84.0 89.5 89.4 96.0 95.9 101 99.5 106 106 112 112
Power consumption kW 19.0 22.6 20.4 24.3 22.1 26.2 23.8 27.6 25.8 29.6 27.5
Capacity control % 5-100 4-100 4-100
Casing colour Ivory white (5Y7.5/1) Ivory white (5Y7.5/1)
Type Hermetically sealed scroll type Hermetically sealed scroll type
Compressor (2.4×1)+(4.2×1)+ (5.2×1)+(4.9×1)+ (3.4×1)+(5.2×1)+ (3.4×1)+(2.9×1)+ (3.4×1)+(5.2×1)+ (3.4×1)+(3.9×1)+ (2.4×1)+(5.2×1)+ (3.7×1)+(4.3×1)+ (2.4×1)+(5.2×1)+ (4.9×1)+(4.2×1)+ (2.4×1)+(3.4×1)+(2.9×1)+
Motor output kW (3.4×1)+(2.9×1) (4.2×1) (5.2×1) (4.9×1)+(4.2×1) (3.4×1)+(2.9×1) (4.9×1)+(4.2×1) (3.7×1)+(4.3×1) (4.9×1)+(4.2×1) (4.9×1)+(4.2×1) (4.9×1)+(4.2×1) (4.9×1)+(4.2×1)
Airflow rate m3/min 119+178+218 191+297 178+191+191 218+297 178+191+218 218+297 119+191+268 268+297 119+191+297 297+297 119+218+297
(1,657×930×765)+(1,657×1,2 (1,657×1,240×765)+ (1,657×930×765)+(1,657×1,2 (1,657×1,240×765)+ (1,657×930×765)+(1,657×1,2 (1,657×1,240×765)+ (1,657×930×765)+(1,657×1,2 (1,657×1,240×765)+ (1,657×930×765)+(1,657×1,2 (1,657×1,240×765)+ (1,657×930×765)+(1,657×1,2
Dimensions (H×W×D) mm 40×765)+(1,657×1,240×765) (1,657×1,240×765) 40×765)+(1,657×1,240×765) (1,657×1,240×765) 40×765)+(1,657×1,240×765) (1,657×1,240×765) 40×765)+(1,657×1,240×765) (1,657×1,240×765) 40×765)+(1,657×1,240×765) (1,657×1,240×765) 40×765)+(1,657×1,240×765)
Machine weight kg 185+215+275 215+291 185+215+215 275+291 185+215+275 275+291 185+215+291 291+291 185+215+291 291+291 185+275+291
Sound level dB(A) 62 66 62 66 63 66 64 67 66 68 66
Operation range ℃DB 10 to 49 10 to 49
Type R-410A R-410A
Refrigerant
Charge kg 6.4+8.3+9.7 8.5+11.7 6.6+8.5+8.5 9.7+11.7 6.6+8.5+9.7 9.8+11.7 6.4+8.5+11.7 11.7+11.7 6.4+8.5+11.7 11.7+11.7 6.4+9.7+11.7
Piping Liquid mm φ19.1 (Brazing) φ19.1 (Brazing)
connections Gas mm φ34.9 (Brazing) φ41.3 (Brazing)
MODEL RXUQ42AMYM* RXUQ44AMYM* RXUQ46AMYM* RXUQ48AMYM* RXUQ50AMYM* RXUQ52AMYM* RXUQ54AMYM* RXUQ56AMYM* RXUQ58AMYM* RXUQ60AMYM*
RXUQ12AYM RXUQ12AYM RXUQ12AYM RXUQ12AYM RXUQ12AYM RXUQ12AYM RXUQ14AYM RXUQ16AYM RXUQ18AYM RXUQ20AYM
Combination units RXUQ12AYM RXUQ12AYM RXUQ14AYM RXUQ16AYM RXUQ18AYM RXUQ20AYM RXUQ20AYM RXUQ20AYM RXUQ20AYM RXUQ20AYM
RXUQ18AYM RXUQ20AYM RXUQ20AYM RXUQ20AYM RXUQ20AYM RXUQ20AYM RXUQ20AYM RXUQ20AYM RXUQ20AYM RXUQ20AYM
Power supply 3-phase 4-wire system, 380-415 V/380 V, 50/60 Hz 3-phase 4-wire system, 380-415 V/380 V, 50/60 Hz
Btu/h 399,000 420,000 444,000 461,000 478,000 498,000 519,000 536,000 553,000 573,000
Cooling capacity
kW 117 123 130 135 140 146 152 157 162 168
Power consumption kW 28.4 30.4 32.1 34.0 35.4 37.4 39.1 41.0 42.4 44.4
Capacity control % 4-100 3-100 3-100 2-100
Casing colour Ivory white (5Y7.5/1) Ivory white (5Y7.5/1)
Type Hermetically sealed scroll type Hermetically sealed scroll type
Compressor (5.2×1)+(5.2×1)+ (5.2×1)+(5.2×1)+ (5.2×1)+(3.4×1)+ (5.2×1)+(3.4×1)+ (5.2×1)+(3.7×1)+ (5.2×1)+(4.9×1)+(4.2×1)+ (3.4×1)+(2.9×1)+(4.9×1)+ (3.4×1)+(3.9×1)+(4.9×1)+ (3.7×1)+(4.3×1)+(4.9×1)+ (4.9×1)+(4.2×1)+(4.9×1)+
Motor output kW (3.7×1)+(4.3×1) (4.9×1)+(4.2×1) (2.9×1)+(4.9×1)+(4.2×1) (3.9×1)+(4.9×1)+(4.2×1) (4.3×1)+(4.9×1)+(4.2×1) (4.9×1)+(4.2×1) (4.2×1)+(4.9×1)+(4.2×1) (4.2×1)+(4.9×1)+(4.2×1) (4.2×1)+(4.9×1)+(4.2×1) (4.2×1)+(4.9×1)+(4.2×1)
Airflow rate m3/min 191+191+268 191+191+297 191+218+297 191+268+297 191+297+297 218+297+297 268+297+297 297+297+297
Dimensions (H×W×D) mm (1,657×1,240×765)+(1,657×1,240×765)+(1,657×1,240×765) (1,657×1,240×765)+(1,657×1,240×765)+(1,657×1,240×765)
Machine weight kg 215+215+291 215+275+291 215+291+291 215+291+291 275+291+291 291+291+291
Sound level dB(A) 65 66 67 68 69 70
Operation range ℃DB 10 to 49 10 to 49
Type R-410A R-410A
Refrigerant
Charge kg 8.5+8.5+11.7 8.5+9.7+11.7 8.5+9.8+11.7 8.5+11.7+11.7 8.5+11.7+11.7 9.7+11.7+11.7 9.8+11.7+11.7 11.7+11.7+11.7
Piping Liquid mm φ19.1 (Brazing) φ19.1 (Brazing)
connections Gas mm φ41.3 (Brazing) φ41.3 (Brazing)
Note: Specifications are based on the following conditions; *Refer to individual models for Green Tick Rating.
•Cooling: Indoor temp.: 27℃DB, 19℃WB, Outdoor temp.: 35℃DB, Equivalent piping length: 7.5 m, Level difference: 0 m.
•Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m.
During actual operation, these values are normally somewhat higher as a result of ambient conditions and oil recovery mode.
When there is concern for noise to the surrounding area such as residences, we recommend investigating the installation location and taking soundproofing measures.
25 23
21 24
22 26
Indoor Unit Lineup A SERIES
VRV A SERIES
Type Model Name VRT (700 mm width type)
Slim Ceiling
Capacity Index 20 25 31.25 40 50 62.5 71 80 100 125 140 200 250 400 500 Mounted Duct
Slim Ceiling
(700 mm width type)
Mounted Duct
Ceiling Mounted Cassette FDKS-C(A)VMB VRT
FXFSQ-AVM VRT
New
Ceiling
(Round Mounted
Flow withCassette
Sensing) smart
FXFSQ-AVM VRT
capacity FDKS-C(A)VMB VRT (900/1,100 mm width type)
(Round Flow with Sensing) smart (900/1,100 mm width type)
FXHQ-MAVE VRT
Residential indoor unit and VRV indoor unit mix system
Ceiling
Wall Suspended
Mounted FXAQ-PVE VRT BP unit
FXHQ-AVM VRT
VRT BP unit
Floor Standing FXLQ-MAVE Max. Residential indoor units VRV indoor units
Concealed
Floor Standing
Concealed Floor Standing
FXNQ-MAVE
FXNQ-MAVE
VRT
VRT 32 indoor
units • BP units are necessary for residential indoor units. Only single outdoor unit (RXUQ6-20AYM) can be connected.
• If a system has both residential indoor units and VRV indoor units, the system is operated under VRT control.
FXVQ-NY1 VRT
VRT
FXVQ-NY1
Floor Standing Max. Residential indoor units VRV indoor units
Floor Standing Duct
Duct FXVQ-NY16
FXVQ-NY16 VRT
(high static pressure type) VRT
(high static pressure type)
32 unitsindoor
Residential
indoor
unit
• BP unitsonly systemfor residential indoor units. Only single outdoor unit (RXQ6-20AYM(W)) can be connected.
are necessary
• If a system has both residential indoor units and VRV indoor units, the system is operated under VRT control.
FXBQ-PVE
FXBQ-PVE VRT
VRT
Clean Room
Clean
Air Room Air Conditioner
Conditioner VRT
FXBPQ-PVE
FXBPQ-PVE VRT Residential indoor unit only system
BP unit BP unit
Heat Reclaim
Heat Reclaim Ventilator
Ventilator VKM-GAV1 3
/h
with DX-Coil VKM-GA(M)V1 3
/h
Heat Reclaim
Heat Reclaim Ventilator
Ventilator VAM-GJVE
VAM-GJVE
3
3 /h
/h
Max. BP unit Residential indoor units only BP unit
Air Handling
Air Handling Unit
Unit AHUR
AHUR
6–120 HP
6–120 HP 32 indoor
units • BP units are necessary for residential indoor units. Only single outdoor unit (RXUQ6-20AYM) can be connected.
• If a system has only residential indoor units, the system is operated under VRT control.
23 25
23 26
24 24
48
Daikin offers a wide range of indoor units includes both VRV and residential models P.171 Ceiling Susp
Outdoor-Air
responding to variety of needs of our customers that require air-conditioning solutions. Processing Unit
Daikin offers a wide range of indoor units includes both VRV and residential models P.171 Ceiling Suspended Type P.155 FXHQ-MAVE
Outdoor-Air
responding to variety of needs of our customers that require air-conditioning solutions.
neup Indoor Unit Lineup
Processing Unit FXMQ-MFV1
FXAQ-AVM FXLQ-MAVE
temperature can be detected to distribution and offers a comfortable
Combine fresh air treatment Combine fresh air treatment
Concealed
provide
Ceiling
Ceilingcomfort
Mountedand energy
Mounted savings. P.129
Cassette
Cassette living environment. and air conditioning,
P.129 Ceiling Mounted Cassette P.129
P.139
supplied from a single system.
4-Way Flow Ceilingand air conditioning,
P.140
FXNQ-MAVE
(Round
(RoundFlow
Flow)with
TypeSensing) Type (Round
(CompactFlow) Type
Multi Flow) Type Suspended Type
supplied from a single system. Concealed Floor Standing Type
Ceiling Mounted Cassette P.139 4-Way Flow Ceiling P.140 harmonised with your interior P.160
FXNQ-MAVE Suitable for p
FXFQ-AVM
FXFSQ-AVM FXZQ-MVE
FXFQ-AVM FXUQ-AVEB décor. conditioning.
(Compact Multi Flow) Type Suspended Type Wall Mounted Type P.157 FloorMounted
Wall Standing Type P.159
P.157 Floor Standing Type P.159
harmonised with your interior Suitable for perimeter zone air
FXZQ-MVE FXUQ-AVEB This slim and stylish indoor unit
décor. conditioning.
FXAQ-AVM FXLQ-MAVE
achieves optimum air distribution,
FXAQ-AVM FXLQ-MAVE
distribution and
temperature canoffers a comfortable
be detected to Quiet, compact,
distribution and designed
and offers for
a comfortable and can be installed without the
Floor Standing Duct Type P.161 Clean Room Air Conditioner P.1
living environment.
provide comfort and energy savings. This slim and
user comfort.
living stylish
environment. indoor unit need for ceiling cavity. FXVQ-NY1 FXBQ-PVE
achieves optimum air distribution,
Quiet, compact, and designed for and can be installed without the
Floor Standing
Concealed Duct Type
Floor Standing Type P.161 Clean Room Air Conditioner
ConcealedP.162 Air Handling
Floor Standing Type Unit P.169
user comfort. need for ceiling cavity. FXVQ-NY16 FXBPQ-PVE
4-Way Mounted
Ceiling Flow Ceiling
Cassette P.140
P.139 Ceiling
4-Way Mounted
Flow Ceiling Cassette P.140
P.141 Ceiling Mounted Cassette
FXVQ-NY1
P.143
FXNQ-MAVE
P.160 FXBQ-PVE AHURP.160
FXNQ-MAVE
(high static pressure type)
Suspended Type
(Compact Multi Flow) Type (Double Flow)Type
Suspended Type (Single Flow) Type
FXVQ-NY16 FXBPQ-PVE
Ceiling Mounted Cassette P.141 Ceiling Mounted Cassette
harmonisedP.143
with your interior Suitable for perimeter
harmonised zone air
with your interior Suitable for perimeter zone air
FXUQ-AVEB
FXZQ-MVE FXUQ-AVEB
FXCQ-AVM FXEQ-AV36
(high static pressure type)
(Double Flow) Type (Single Flow) Type décor. conditioning.
décor. conditioning.
This slim and stylish indoor unit This slim and stylish indoor unit
FXCQ-AVM FXEQ-AV36
achieves optimum air distribution, achieves optimum air distribution,
Quiet, compact,
and can and designed
be installed for
without the Thin, lightweight,
Floor
andwithout
easy tothe
Standing
install in
Duct Type P.161 Clean Room Air Conditioner
Floor Standing
P.162 Air Handling
Duct Unit
Type P.161 Clean Room
P.169 Air Conditioner P.162 Air Handling Unit P.169
and can be installed
user large spaces.
needcomfort.
for ceiling cavity. narrow
need forceiling
ceilingspaces
cavity. FXVQ-NY1 FXBQ-PVE FXVQ-NY1 AHUR FXBQ-PVE AHUR
Flexible interior design Suitable for hospitals
for each tenant. Integrate your air handling other clean spaces
Thin, lightweight, and easy to install in
FXVQ-NY16 FXBPQ-PVE FXVQ-NY16 large spaces. FXBPQ-PVE unit in a total solution for
narrow ceiling
Ceiling spaces Cassette P.143
Mounted
Ceiling Mounted Cassette P.141 Ceiling Mounted
Slim Ceiling MountedCassette
Duct Type P.143 P.145
(high static pressure type)
Slim Ceiling Mounted P.147
(high static pressure type)
Flexible interior design Suitable for hospitals and large size spaces such as
(Single
(DoubleFlow)Flow)Type
Type (Single Flow) Type for each tenant. other clean spaces factories and large stores.
Duct Type
Slim Ceiling Mounted Duct Type
FXEQ-AV36
FXCQ-AVM
P.145 Slim Ceiling Mounted
FXEQ-AV36
FXDSQ-AVM
Duct Type
P.147
FXDQ-PDVE(T) Residential indoor units with conn
FXDSQ-AVM FXDQ-PDVE(T)
Stylish & compact design, and 3D
FXDQ-NDVE(T) Residential indoor units with connection to BP units
Integrate your air handling Slim Ceiling Mounted Duct Type Wall
P.165Integrate yourMounted
air handling Type P.1
Thin, lightweight, and easy to install in Slim design, quietness and
FXDQ-NDVE(T) large spaces. large spaces. unit in a total solution for unit in a total solution for
narrow ceiling spaces provide comfort and energy savings. static pressure switching.
Stylish & compact design, and 3D Flexible interior design Flexible interior design large size spaces such as
Suitable for hospitals and SuitableFDKS-EAVMB
for hospitals and large sizeFTKJ-NVMW
spaces such as
for each tenant. Slim
other clean CeilingMounted
Slimspaces
Ceiling Mounted
for eachDuct
Duct TypeType
tenant. Wall
P.165 factories Mounted
and large stores. Type Wall
other clean Mounted
spaces
P.166 Type
Wall Mounted Type P.167
factories and large stores.
Slim design, quietness and
provideCeiling
Slim comfort Mounted
and energy savings. P.147 static pressure switching. FDKS-EAVMB FTKJ-NVMW FTKS-DVM FTKS-DVM
Slim Ceiling Mounted Duct Type P.145 Slim
SlimCeiling
CeilingMounted
Mounted P.147
P.148 Middle Static Pressure P.149
Duct Type Duct Type
Duct Type (Compact Series) Ceiling Mounted Duct Type
Residential indoor units with Residential
connection indoor
to BP units
units with connection to BP units
FDKS-C(A)VMB FTKJ-NVMS
Slim Ceiling Mounted P.148 Middle Static Pressure P.149
FXDQ-PDVE(T)
FXDSQ-AVM FXDQ-PDVE(T)
FXDQ-SPV1 FXSQ-PAVE FTKS-BVMA FTKS-BVMA
Duct Type (Compact Series) Ceiling Mounted Duct Type
FDKS-C(A)VMB FTKJ-NVMS
FXDQ-NDVE(T) FXDQ-NDVE(T) Slim and smooth design suits Elegant appearance w
FXDQ-SPV1 FXSQ-PAVE
Stylish & compact design, and 3D Slim Ceiling Mounted Duct Type Wall Mounted Type your shallow ceiling European style
P.165 Slim CeilingP.166
MountedWall
DuctMounted
Type P.165Type Wall Mounted P.167 Type P.166
FTKS-FVM Wall Mounted Type
FTKS-FVM P.167
Slim design, quietness and Slim
Slimdesign, quietness
and compact and for easy and
design Middle static pressure and slim design
static pressure
comfortswitching. Slim and smooth design suits
Slim and smooth design suits Elegant appearance with Stylish flat panel harmonises
provide and energy savings. static pressure switching.FDKS-EAVMB FTKJ-NVMW FDKS-EAVMB FTKS-DVM FTKS-DVM
your shallow ceiling your shallowFTKJ-NVMW
ceiling European style with your interior décor
Middle and high static pressure High static pressure allows VKM-GAV1 VAM-GJVE
FXMQ-MFV1 127
27
Heat Reclaim Ventilator with P.175 Heat Reclaim
Heat Reclaim Ventilator
Ventilator with P.179
P.175 Heat Reclaim Ventilator P.179
FXMQ-PVM FXMQ-PVM
FXMQ-MVE9 DX-Coil DX-Coil
127
27 FXHQ-AVM
VKM-GAV1 VAM-GJVE
128
28
High static
Middle and pressure allows
high static pressure High static pressure allows VKM-GAV1 VAM-GJVE
Combine fresh air treatment
and air conditioning,
supplied from a single system.
27 27
12725 28
128 28
2628
128
FXAQ-AVM FXLQ-MAVE
YouTube site.
FXFSQ-A FXFQ-A Ceiling Mounted Cassette (Round Flow with Sensing) Type
ding Type MODEL FXFSQ25AVM FXFSQ32AVM FXFSQ40AVM FXFSQ50AVM FXFSQ63AVM FXFSQ80AVM FXFSQ100AVM FXFSQ125AVM FXFSQ140AVM
Power supply 1-phase, 220 - 240 V/220-230 V, 50/60 Hz
P.160 with sensing Cooling capacity
Btu/h 9,600 12,300 15,400 19,100 24,200 30,700 38,200 47,800 54,600
kW 2.8 3.6 4.5 5.6 7.1 9.0 11.2 14.0 16.0
ne air Power consumption kW 0.028 0.035 0.056 0.061 0.092 0.164 0.170 0.194
Casing Galvanised steel plate
Wide variety of decoration panels (Option) m3/min 13/12.5/11.5/11/10 17/13.5/12.5/12/11 23/20.5/19/14.5/11 23.5/21/20/16/13.5 24.5/22/20.5/20/15 33.5/30.5/27/23.5/21 34.5/31.5/28.5/25.5/23 35.5/32.5/29.5/26.5/23
cfm 459/441/406/388/353 600/477/441/424/388 812/724/671/512/388 830/741/706/565/477 865/777/724/706/530 1,183/1,077/953/830/741 1,218/1,112/1,006/900/812 1,253/1,147/1,041/935/812
r Handling Unit Designer choice
P.169 has been given a boost with the increase in number of new types of decoration panels. Sound level (H/HM/M/ML/L) dB(A) 30/29.5/28.5/28/27 35/29.5/29/28/27 38/35/34.5/29.5/27 38/36/35.5/31.5/28 39/37/36/35.5/31 44/41/38/35/33 45/42.5/39.5/37/35 46/43.5/40.5/38/35
Dimensions (H×W×D) mm 256×840×840 298×840×840
HUR
Machine weight kg 19 24 22 25 26
Liquid (Flare) 6.4 9.5
Piping
connections Gas (Flare) mm 12.7 15.9
Drain VP25 (External Dia. 32/Internal Dia. 25)
Integrate your air handling Btu/h 9,600 12,300 15,400 19,100 24,200 30,700 38,200 47,800 54,600
Cooling capacity
unit in a total solution for kW 2.8 3.6 4.5 5.6 7.1 9.0 11.2 14.0 16.0
large size spaces such as Power consumption kW 0.029 0.036 0.040 0.063 0.096 0.158 0.178 0.203
factories and large stores. Casing Galvanised steel plate
m3/min 13/12.5/11.5/11/10 17/13.5/13/12/11 18/17/13.5/12.5/11 21/20/16/15/13.5 22.5/21.5/21/20/15 32/29/26/23/21 33/30.5/28/25.5/21 35.5/32.5/29.5/26.5/23
- Fresh White - - Fresh White - - Black - cfm 459/441/406/388/353 600/477/459/424/388 635/600/477/441/388 741/706/565/530/477 794/759/741/706/530 1,130/1,024/918/812/741 1,165/1,077/988/900/741 1,253/1,147/1,041/935/812
on to BP FXFSQ
units
Sound level (H/HM/M/ML/L) dB(A) 30/29.5/28.5/28/27 35/29.5/29/28/27 35/33.5/29.5/28.5/27 36/35.5/31.5/31/28 37/36.5/36/35.5/29.5 43/40.5/37.5/35/33 44/41.5/39/36.5/33 46/43.5/40.5/38/35
series only Designer panel Standard panel Dimensions (H×W×D) mm 256×840×840 298×840×840
Machine weight kg 19 22 25 26
Standard panel - Black - - Fresh White - Liquid (Flare) 9.5
6.4
with sensing Piping
Gas (Flare) mm 12.7 15.9
all Mounted Type P.167 connections
Drain VP25 (External Dia. 32/Internal Dia. 25)
TKS-DVM Designer panel (Option) •Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
•Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)
•Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.
Function List Round Flow with Sensing Type Round Flow Type
Standard panel with sensing*1 Standard panel*2 Designer panel*2 Sensing sensor low mode *1
BYCQ125EEF (Fresh White) BYCQ125EAF (Fresh White) BYCQ125EAPF (Fresh White) Sensing sensor stop mode *1
28
128
Auto swing
FXFSQ series only *1.Sensing function is applicable when Auto grille panel*2
sensing panel is installed. Swing pattern selection
Standard panel with sensing*1 Standard panel*2 BYCQ125EASF
*2.These panels do not contain the (Fresh White) High ceiling application
BYCQ125EEK (Black) BYCQ125EAK (Black) sensing function. *1. Applicable when sensing panel is installed.
29 29
12927 30
2830
130
décor. conditioning.
Floor Standing Duct Type P.161 Clean Room Air Conditioner P.162 Air Handling Unit P.169
FTKS-FVM
1 24
with sensing
Slim and smooth design suits Elegant appearance with
your shallow ceiling the automatically adjusts operation with
of the
your indoor unit to
Detecting European style interior décor
Sensing Sensor Functions*7,8,9 *7. Applicable when sensing panel (BYCQ125EEF/EEK) is installed.
*8. These functions are not available when using the group control system.
VKM-GAV1 VAM-GJVE *9. User can set these functions with remote controller.
Detecting the
2.7m
ceiling
Sensing sensor low mode (default: OFF)
height When there are no people in a room,
average temperature
the set temperature is shifted automatically. Operation is
- The system automatically saves energy by detecting reduced in places
80cm whether or not the room is occupied. The set temperature where there are
approx.8.5m 28
128 is shifted automatically if the room is unoccupied. no people.
*[Concerning infrared presence sensor]
- People are detected by large movements such as the motion of people walking at a • Cooling set temperature: 26°C • Shift temperature: 1.0°C
certain distance away from sensor. Example
- Human detection is not possible for blind areas of sensor. • Shift time: 30 min. • Limit cooling set temperature: 30°C
Shift temperature and time can be selected from 0.5 to 4°C in 0.5°C increments and 15, 30, 45, 60, 90 or 120 minutes respectively
with remote controller.
31 31
13129 32
3032
132
New Round Flow
YouTube site.
areas that were either too cool or not cool enough. Comfort to the Entire Room with Even Temperatures and No Cold Air Pockets at Floor Level
Problem 1 4-way cassette (Swing)
30.0
29.0
Comparison Conditions
28.0 Room size:
Hot outdoor air entering through 27.0 Width 7.5m x depth 7.5m
26.0 x height 2.6m
windows and walls causes these
areas to become hot. 4-Way Flow 25.0
24.0
Indoor unit capacity: 80 class
Outdoor air temperature: 35°C
23.0
22.0
21.0 high / swing
Problem 2 20.0
savings by reducing
causes discomfort for people in 3 uneven temperatures
the room. *2.Calculated under the following comparison
conditions: When the average temperature at a
Problem 4 temperature. (26°C)
Quick descent of cool air causes 4 2
Full comfort is
the room. provided with no
cold feet.
(Strongly)
All-round Two-way
flow flow
(all-round flow) begins. switches from 3-way horizontal flow to 4-way downward flow [swing] to
[Table 2]
Wall surface
2-way horizontal flow to 4-way downward flow [swing].)
Distance Minimum distance between Minimum distance between indoor units
Circulation airflow functions during connection with wired remote controller. to wall indoor units [Table 2]
Note: (BRC1E63). However, use is not possible for the following conditions: [Table 1] Indoor unit FXF(S)Q FXF(S)Q FXF(S)Q
Results may vary depending on capacity 25-50 63/80 100-140
Cools areas around Cools entire room using Cools areas around Cools entire room using 1.8m or more above floor surface
walls using walls using equipment conditions, room size, - When a sealing material of air discharge outlet and branch ducts are used;
4-way swing flow 4-way swing flow - When individual airflow setting is selected;
Minimum
4m or more 5m or more 7m or more
2-way horizontal flow 2-way horizontal flow and distance from indoor unit to walls.
- When using group control other than round flow.
Floor surface distance
33 33
13331 34
3234
134
New Round Flow
YouTube site.
Other Functions
*1. Applicable when wired remote controller BRC1E63 is used.
There are
Position 0
marks near
( the air outlets.
highest position) Remote controller L-shaped Opposite
BRC1E63 screen
No individual Position 0 (Highest point) (E.g., installed in (E.g., installed (E.g., installed in (E.g., installed in
setting middle of ceiling) near a wall) a corner) a long room)
Position 1
( )
Position 2
Note:
Position 3 Required * - Whatever the discharge direction, the same type of panel is used. If installing for other than all-round
distance to
Swing Position 4 Position 4 (Lowest point) wall surface
Minimum distance
of 500mm
(Up/down) ( Swing for closing -
* 200mm for corner
-
lowest position) air discharge * closing
35 35
13533 36
3436
136
Indoor Unit Lineup VRV Indoor Units
*1.Body height (ceiling required space) is 42 mm higher than standard panel. Ceiling Height
Drop Length
Standard (m)
Auto grille panel
2.4 1.2
256 mm 261 mm 2.7 1.6
298 mm +55 mm*2
55 mm*2
303 mm
24 mm diameter drain outlet 3.0 2.0
The drain outlet allows 3.5 2.4
*2.Body height (ceiling required space) is 55 mm higher than standard panel.
3.8 2.8
*When the ceiling space is limited, an optional panel spacer is available. dental mirror for inspection 4.2 3.1
(See page 207)
100) of the internal cleanliness 4.5 3.5
of the drain pan. Removal 5.0* 3.9
Ease in temporary hanging of the suction panel
Easy height adjustment of decoration panel enables access. Please refer to “criteria for ceiling height
Each corner of the unit has an and number of air discharge outlets” on
adjuster pocket that lets you In addition to the temporary page 36.
136.
37 37
13735 38
3638
138
Indoor Unit Lineup VRV Indoor Units
Ceiling Mounted Cassette (Compact Multi Flow) Type FXZQ-M 4-way Flow Ceiling Suspended Type FXUQ-A
Unit body and suction panel adopted round shapes and Built-in electronic Current model New model
1 Wide discharge angle: 0° to 60° Dimensions correspond with 600 mm X 600 mm architectural realised a slim appearance design. The unit can be used for expansion valve
Auto swing Fixed angles: 5 levels various locations such as the ceilings with no cavity and eliminates the need for
bare ceilings. a BEV unit, which
Low operation sound level BEV unit is
needed
BEV unit is
not needed
Flaps close automatically when the unit stops, which gives a installation.
Drain pump is equipped as standard accessory with
0° 0° 0° simple appearance.
750 mm lift.
60° 60° 60° 60° adoption of a new heat exchanger with smaller tubes, DC
*Angles can be also set on site to prevent drafts (0°-35°) fan motor and DC drain pump motor.
or soiling of the ceiling (25°-60°), other than standard setting (0°-60°). capacities are installed in the same area.
750 mm Drain pump is equipped as a standard accessory, and the lift
2 direction adjustment can be individually set for each air height has been improved from 500 mm to 600 mm.
enabling installation in the corner of a room. Depending on installation site requirements or room
selected with wired remote controller BRC1E63, which conditions, 2-way, 3-way and 4-way discharge patterns are
realises the optimum air distribution. available.
Position 0 Position 2
Position 3 Swing
L-shaped
• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
•Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. • Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)
•Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)
• Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward.
•Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.
During actual operation, these values are normally somewhat higher as a result of ambient conditions. During actual operation, these values are normally somewhat higher as a result of ambient conditions
39 39
13937 40
3840
140
Indoor Unit Lineup VRV Indoor Units
41 41
14139 42
4042
142
Indoor Unit Lineup VRV Indoor Units
to left or right within 45° swinging between 20° to 70° Power consumption kW 0.026 0.027 0.034 0.046 0.048 0.067
Casing Galvanised steel plate
Airflow rate m3/min 6.0/5.4/4.9/4.4/4.0 6.9/6.4/5.8/5.3/4.8 8.0/7.5/7.0/6.3/5.5 9.8/8.8/7.8/7.0/6.2 12.5/11.4/10.4/9.5/8.7 15.0/13.6/12.2/11.0/9.8
z (H/HM/M/ML/L) cfm 212/191/173/155/141 244/226/205/187/169 282/265/247/222/194 346/311/275/247/219 441/402/367/335/307 530/480/431/388/346
and quiet operation mode, which provides comfortable Sound level (H/HM/M/ML/L) dB(A) 30/29/28/27/26 32/31/30/29/28 35/34/33/32/30 38/37/35/33/31 38/37/35/33/31 43/41/39/37/35
Dimensions (H×W×D) mm 200×840×470 200×1,240×470
43 43
14341 44
4244
144
Indoor Unit Lineup VRV Indoor Units
Slim Ceiling Mounted Duct Type (Standard Series) FXDQ-PD / ND Slim Ceiling Mounted Duct Type (Compact Series) FXDQ-SP
Slim design, quietness and Slim and compact design for easy
static pressure switching and flexible installation
Only 200 mm in height, this model can be installed in It comes with a slim and compact design with a height of only
Suitable to use in drop-ceilings! rooms with as little as 240 mm in height for the ceiling 200 mm that requires as little as 240 mm in height for
space between the drop-ceiling and ceiling slab. the ceiling space between the drop-ceiling and ceiling slab.
Only 700 mm in width Great for The depth of the product is only 450 mm which is suitable to
and 23 kg in weight, hotel use! FXDQ20-32PD
install in limited spaces.
FXDQ40/50ND
this model is suitable
to install in limited spaces * 1,100 mm in width for Great for
like drop-ceilings in hotels. 200 mm the FXDQ63ND model.
900 mm 200 mm residential use
200 mm
Only 700 mm Suspension bolt* Air filter
700 mm* Only 450 mm
Control of the airflow rate can be selected from 3-step control
AIR 240 mm *For FXDQ20-32SP models
Discharge
It is available in two types – ceiling return and ordinary
and Auto. Auto airflow rate control can be selected with wired grille * Suction grille *
duct to suit different installation conditions.
remote controller BRC1E63. AIR * To be obtained locally
Low operation sound level. FXDQ-PD and FXDQ-ND models are available in two Duct Canvas Duct
types to suit different installation conditions. bellows
and air
External static pressure selectable Air suction Air
FXDQ-PD/NDVE: with a drain pump (750 mm lift) panel
discharge discharge
by remote controller switching as a standard accessory
make this indoor unit a very FXDQ-PD/NDVET: without a drain pump
comfortable and flexible model. Air suction Air suction
10 Pa-30 Pa/factory set:
10 Pa for FXDQ-PD models.
15 Pa-44 Pa/factory set: 750 mm Drain pump is equipped as
15 Pa for FXDQ-ND models.
standard accessory with 750
450 mm
200 mm
mm lift.
600 mm
Ceiling 240 mm 750 mm
and
above 700 mm
Specifications
Ceiling
Ceiling
Side view Top view
with drain pump FXDQ20PDVE FXDQ25PDVE FXDQ32PDVE FXDQ40NDVE FXDQ50NDVE FXDQ63NDVE
MODEL
without drain pump FXDQ20PDVET FXDQ25PDVET FXDQ32PDVET FXDQ40NDVET FXDQ50NDVET FXDQ63NDVET
Power supply
Btu/h 7,500 9,600
1-phase, 220-240 V/220 V, 50/60 Hz
12,300 15,400 19,100 24,200
Specifications
Cooling capacity
kW 2.2 2.8 3.6 4.5 5.6 7.1 MODEL FXDQ20SPV1 FXDQ25SPV1 FXDQ32SPV1 FXDQ40SPV1 FXDQ50SPV1 FXDQ63SPV1
Power consumption Power supply 1-phase, 220-240 V, 50 Hz
(FXDQ-PD/NDVE) 1 kW 0.086 0.089 0.160 0.165 0.181
Btu/h 7,500 9,600 12,300 15,400 19,100 24,200
Cooling capacity
Power consumption kW 2.2 2.8 3.6 4.5 5.6 7.1
kW 0.067 0.070 0.147 0.152 0.168
(FXDQ-PD/NDVET) 1 Power consumption 1 kW 0.072 0.075 0.078 0.180 0.180 0.196
Casing Galvanised steel plate Casing Galvanised steel plate
m3/min 8.0/7.2/6.4 10.5/9.5/8.5 12.5/11.0/10.0 16.5/14.5/13.0 m3/min 8.7/7.6/6.5 9.0/8.0/7.0 10.0/9.0/8.0 15.0/13.0/10.5 20.0/16.0/12.5
Airflow rate (HH/H/L) Airflow rate (HH/H/L)
cfm 282/254/226 371/335/300 441/388/353 583/512/459 cfm 307/268/229 318/282/247 353/318/282 530/459/371 706/565/441
45 46
147 148
Indoor Unit Lineup VRV Indoor Units
pressure when ducts advanced needs such as when During installation, even if the external static pressure
are short. using dampers and long ducts.
Bottom suction is possible which facilitate installation Casing Galvanised steel plate
14947
49 48150
50
IndoorUnit
Indoor UnitLineup
Lineup VRV Indoor Units
CeilingMounted
Ceiling MountedDuct
DuctType
Type FXMQ-PA
FXMQ-PA/ /MM
Middleand
Middle andhigh
highstatic
staticpressure
pressure MODEL
MODEL FXMQ20PAVE
FXMQ20PAVE FXMQ25PAVE
FXMQ25PAVE FXMQ32PAVE
FXMQ32PAVE FXMQ40PAVE
FXMQ40PAVE FXMQ50PAVE
FXMQ50PAVE
Power
Power supply
supply 1-phase,
1-phase, 220-240
220-240 V/220
V/220 V, 50/60
V, 50/60 Hz Hz
Btu/h
Btu/h 7,500
7,500 9,600
9,600 12,300
12,300 15,400
15,400 19,100
19,100
Cooling
Cooling capacity
capacity
kWkW 2.22.2 2.82.8 3.63.6 4.54.5 5.65.6
Power
Power consumption
consumption kWkW 1
0.056
0.056 1 1
0.060
0.060 1 1
0.151
0.151 1 1
0.128
0.128 1
Casing
Casing Galvanised
Galvanised steel
steel plate
plate
Using
Using a DC
a DC fanfan motor,
motor, thethe external
external static
static pressure
pressure can
can
bebe controlled
controlled within
within a range
a range of of
3030 Pa*
Pa* to to 200
200 Pa*.
Pa*. m3/min
m3/min 9/7.5/6.5
9/7.5/6.5 9.5/8/7
9.5/8/7 16/13/11
16/13/11 18/16.5/15
18/16.5/15
cfmcfm 318/265/230
318/265/230 335/282/247
335/282/247 565/459/388
565/459/388 635/582/530
635/582/530
Adjustable
Adjustable external
external static
static pressure
pressure External
External static
static pressure
pressure Pa Pa 30-100
30-100 (50)(50)
2 2 30-160
30-160 2
(100)
(100) 2 50-200
50-200 2
(100)
(100) 2
Sound
Sound level
level (HH/H/L)
(HH/H/L) dB(A)
dB(A) 33/31/29
33/31/29 34/32/30
34/32/30 39/37/35
39/37/35 41/39/37
41/39/37
Dimensions
Dimensions (H×W×D)
(H×W×D) mmmm 300x550x700
300x550x700 300x700x700
300x700x700 300x1,000x700
300x1,000x700
30Pa*
30 Pa* 200Pa*
200 Pa* Machine
Machine weight
weight kg kg 25 25 27 27 35 35
Liquid
Liquid (Flare)
(Flare) 6.46.4
Piping
Piping
Gas
Gas (Flare)
(Flare) mmmm 12.7
12.7
connections
connections
SetSet to low
to low static
static SetSet to high
to high static
static pressure
pressure for for
Drain
Drain VP25
VP25 (External
(External Dia,Dia, 32/Internal
32/Internal Dia,Dia,
25)25)
pressure
pressure whenwhen ducts
ducts advanced
advanced needs
needs such
such as as when
when
areare short.
short. using
using dampers
dampers andand long
long ducts.
ducts. MODEL
MODEL FXMQ63PAVE
FXMQ63PAVE FXMQ80PAVE
FXMQ80PAVE FXMQ100PAVE FXMQ125PAVE
FXMQ100PAVE FXMQ125PAVE FXMQ140PAVE
FXMQ140PAVE
Power
Power
supply
supply 1-phase,
1-phase,
220-240
220-240
V/220
V/220
V, 50/60
V, 50/60
Hz Hz
Btu/h
Btu/h 24,200
24,200 30,700
30,700 38,200
38,200 47,800
47,800 54,600
54,600
Cooling
Cooling
capacity
capacity
conditions
conditions such
such asas duct
duct length.
length. kWkW 7.17.1 9.09.0 11.2
11.2 14.0
14.0 16.0
16.0
Power
Power consumption
consumption kWkW 0.138
0.138 1 1 0.185
0.185 1 1 0.215
0.215 1 1 0.284
0.284 1 1 0.4051
0.405 1
*30*30 Pa–100
Pa–100 PaPa
forfor FXMQ20PA-32PA
FXMQ20PA-32PA
Casing
Casing Galvanised
Galvanised steel
steel plate
plate
*30*30 Pa–160
Pa–160 PaPa
forfor FXMQ40PA
FXMQ40PA
*50*50 Pa–200
Pa–200 PaPa
forfor FXMQ50PA-125PA
FXMQ50PA-125PA m3/min
m3/min 19.5/17.5/16
19.5/17.5/16 25/22.5/20
25/22.5/20 32/27/23
32/27/23 39/33/28
39/33/28 46/39/32
46/39/32
*50*50 Pa–140
Pa–140 PaPa
forfor FXMQ140PA
FXMQ140PA cfmcfm 688/618/565
688/618/565 883/794/706
883/794/706 1,130/953/812
1,130/953/812 1,377/1,165/988
1,377/1,165/988 1,624/1,377/1,130
1,624/1,377/1,130
External
External static
static pressure
pressure Pa Pa 50-200
50-200 2
(100)
(100) 2 50-140
50-140 2
(100)
(100) 2
AllAll models
models areare only
only 300
300 mmmm
in in height
height andand
thethe
Sound
Sound level
level (HH/H/L)
(HH/H/L) dB(A)
dB(A) 42/40/38
42/40/38 43/41/39
43/41/39 44/42/40
44/42/40 46/45/43
46/45/43
weight
weight of of
thethe FXMQ40-140PA
FXMQ40-140PA hashas been
been reduced.
reduced.
Dimensions
Dimensions (H×W×D)
(H×W×D) mmmm 300×1,000×700
300×1,000×700 300×1,400×700
300×1,400×700
Drain
Drain pump
pump is is equipped
equipped asas Machine
Machine weight
weight kg kg 35 35 45 45 46 46
standard
standard accessory
accessory with
with 700700
mmmm Liquid
Liquid (Flare)
(Flare) 9.59.5
700
700 mmmm lift.lift. Piping
Piping
Gas
Gas (Flare)
(Flare) mmmm 15.9
15.9
Separate
Separate drain
drain pipe
pipe connections
connections
Ceiling
Ceiling
Easy
Easy maintenance
maintenance andand inspection
inspection opening
opening Drain
Drain VP25
VP25 (External
(External Dia,Dia, 32/Internal
32/Internal Dia,Dia,
25)25)
Inspection
Inspection and
andcleaning
cleaningis is •Cooling:
•Cooling: Indoor
Indoor temp.:
temp.: 27°CDB,
27°CDB, 19°CWB,
19°CWB, Outdoor
Outdoor temp.:
temp.: 35°CDB,
35°CDB, Equivalent
Equivalent piping
piping length:
length: 7.5 7.5 m, Level
m, Level difference:
difference: 0 m.0 m.
facilitated
facilitated
byby
separating
separating thethe •Capacity
•Capacity
•Sound
•Sound
of indoor
of indoor
level:
level:
unit unit
Anechoic
Anechoic
is only
is only
chamber
chamber
for reference.
for reference.
conversion
conversion
Actual
Actual
value,
value,
capacity
capacity
measured
measured
of indoor
of indoor
at a at
unit unit
a point
point 1.5 m
is based
is based
1.5downward
on total
on the
m downward
the total
fromfrom
capacity
capacity
the unit
the unit
index.
index. (See(See
centre.
centre.
Engineering
Engineering DataData
BookBook for details.)
for details.)
selected
selected with
with wired
wired remote
remote controller
controller BRC1E63.
BRC1E63. drain
drain
pipe
pipe
andand
inspection
inspection 1: Power
1: Power
During
During actual
actual
consumption
consumption
operation,
operation,
values
values
these
these
are based
are based
values
values are normally
are normally
on conditions
on conditions of rated
of rated
somewhat
somewhat
external
external static
higher
higher as aas
static
a result
result
pressure.
pressure.
of ambient
of ambient conditions.
conditions.
Low
Low operation
operation sound
sound level
level opening
opening andand
bybythethe
drain
drainpanpan control.
control. These
These values
values indicate
indicate the lowest
the lowest andand highest
highest possible
possible static
static pressures.
pressures. The The rated
rated static
static pressure
pressure is 50isPa
50for
Pa FXMQ20-32PA
for FXMQ20-32PA
andand
100 100 Pa FXMQ40-140PA.
Pa for for FXMQ40-140PA.
maintenance
maintenance check
check hole.
hole. Drain
Drain panpan maintenance
maintenance
check
check hole
hole MODEL
MODEL FXMQ200MVE9
FXMQ200MVE9 FXMQ250MVE9
FXMQ250MVE9
DCDC
fanfan motor
motor is is used
used to to realise
realise energy-saving
energy-saving
Power
Power supply
supply 1-phase,
1-phase, 220-240
220-240 V/220
V/220 V, 50/60
V, 50/60 Hz Hz
operation.
operation. AnAn antibacterial
antibacterial treatment
treatment thatthat
usesuses silver
silver ions
ions hashas Btu/h
Btu/h 76,400
76,400 95,500
95,500
Cooling
Cooling capacity
capacity
Easy
Easy installation
installation been
been applied
applied to to
thethe drain
drain pan,pan, preventing
preventing thethe kWkW 22.4
22.4 28.0
28.0
growth
growth of of slime,
slime, mould
mould andand bacteria
bacteria thatthat cause
cause Power
Power
consumption
consumption kWkW 1
1.294
1.294 1 1
1.465
1.465 1
during
during test
test operation.
operation. It is
It is automatically
automatically adjusted
adjusted to to
thethe blockages
blockages andand odours.
odours. (The
(The lifespan
lifespan of of a silver
a silver ionion Casing
Casing Galvanised
Galvanised steel
steel plate
plate
range
range between
between approximately
approximately ±10%
±10% of of
thethe rated
rated HHHH taptap cartridge
cartridge depends
depends ononthethe usage
usage environment,
environment, butbut m3/min
m3/min 58/50
58/50 72/62
72/62
should
should bebe changed
changed once
once every
every twotwoto to three
three years.)
years.)
220220
V V 48/45
48/45
Sound
Sound level
level (H/L)
(H/L) dB(A)
dB(A)
Built-in
Built-in Drain
Drain Pump
Pump (Option)
(Option) 240240
V V 49/46
49/46
Pressure
Pressure Control
Control Housing
Housing thethe drain
drain pumppump inside
inside thethe unit
unit reduces
reduces thethe Dimensions
Dimensions (H×W×D)
(H×W×D) mmmm 470×1,380×1,100
470×1,380×1,100
External
External static
static pressure
pressure cancan space
space required
required forfor installation.
installation. kg kg
Machine
Machine weight
weight 137137
bebe easily
easily adjusted
adjusted using
using a a Without
Without drain
drain pump
pump With
With drain
drain pump
pump
change-over
change-over switch
switch inside
inside Liquid
Liquid (Flare)
(Flare) 9.59.5
Piping
Piping
thethe electrical
electrical boxboxto to meet
meet thethe GasGas (Brazing) mmmm
(Brazing) 19.1
19.1 22.2
22.2
0–2500–250 connections
connections
resistance
resistance in the
in the duct
duct mm mm
Drain
Drain PS1B
PS1B
system.
system. 470470
mm mm 470470
mm mm
FXMQ200/250MVE9
FXMQ200/250MVE9 222 mm
222 mm • Cooling:
• Cooling: Indoor
Indoor temp.:
temp.: 27°CDB,
27°CDB, 19°CWB,
19°CWB, Outdoor
Outdoor temp.:
temp.: 35°CDB,
35°CDB, Equivalent
Equivalent piping
piping length:
length: 7.5 7.5 m, Level
m, Level difference:
difference: 0 m.0 m.
25 mm25 mm • Capacity
• Capacity of indoor
of indoor unit unit is only
is only for reference.
for reference. Actual
Actual capacity
capacity of indoor
of indoor unit unit is based
is based on total
on the the total capacity
capacity index.
index. (See(See Engineering
Engineering DataData
BookBook for details.)
for details.)
• Sound
• Sound level:
level: Anechoic
Anechoic chamber
chamber conversion
conversion value,
value, measured
measured at a at a point
point 1.5 m1.5downward
m downward fromfrom the unit
the unit centre.
centre.
During
During actual
actual operation,
operation, these
these values
values are are normally
normally somewhat
somewhat higher
higher as aas a result
result of ambient
of ambient conditions.
conditions.
Indoor
Indoor unitunit Indoor
Indoor unitunit
1: Power
1: Power consumption
consumption values
values are based
are based on conditions
on conditions of standard
of standard external
external static
static pressure.
pressure.
2: External
2: External static
static pressure
pressure is changeable
is changeable to change
to change overover the connectors
the connectors inside
inside electrical
electrical box,box,
this this pressure
pressure meansmeans "Standard-High
"Standard-High static
static pressure".
pressure".
49
51151 50152
52
Indoor Unit Lineup VRV Indoor Units
dB(A)
Sound level
Indoor unit
H M L *Water used in the test-run can be drained from the air
discharge opening rather than from the side as was formerly
FXHQ32MA 36 ----- 31
the case.
New 125 / 140 models provide greater capacity FXHQ63MA 39 ----- 34
for large spaces FXHQ100MA 45 ----- 37
The technology of the DC fan motor, wide sirocco fan, FXHQ125A 46 41 37 Drain pump kit (option) can be easily incorporated.
FXHQ140A 48 42 37
and quiet operation. Drain pipe connection can be done inside the unit.
Refrigerant and drain pipe outlets are at the same
opening.
Sophisticated design Easy maintenance
Flap neatly closes when 600
not in use. Condensation does not easily mm
form on and dirt does not cling to
Drain pump kit
It is easy to clean. Non-dew flap (built inside the unit)
Suitable for high ceilings All wiring and internal servicing can be done from
the unit. under the unit.
4.3 Oil-resistant plastic is used for the air suction grille.
m Easier piping work for rear side
environments. by removable frame
• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
• Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)
• Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward.
Signal receiver unit (Installed type) During actual operation, these values are normally somewhat higher as a result of ambient conditions.
Wireless remote controller is supplied
in a set with a signal receiver.
15551
55 53 52
54156
56
Indoor Unit Lineup VRV Indoor Units
Flat panel can be cleaned with only the single pass of a cloth across their smooth surface.
Flat panel can also be easily removed and washed for more thorough cleaning.
Drain pump kit is available as optional accessory, which lifts the drain 1,000 mm from the bottom of the unit.
Height of drain-up
Indoor unit
Drain pump kit
The louver closes automatically when the unit stops.
Discharge angle is automatically set at the same angle as previous operation when restart.
15753
57 55 54
56158
58
Indoor Unit Lineup VRV Indoor Units
Designed to be concealed
Suitable for perimeter zone air conditioning in the perimeter skirting-wall
Floor Standing types can be hung on the wall for easier The unit is concealed in skirting-wall of perimeter, that enables to create high class interior design.
cleaning. Running the piping from the back allows the
unit to be hung on walls. Cleaning under the unit, where
The connecting port faces downward,
dust tends to accumulate, is considerably easier.
greatly facilitating on-site piping work.
Connecting
port
MODEL FXLQ20MAVE FXLQ25MAVE FXLQ32MAVE FXLQ40MAVE FXLQ50MAVE FXLQ63MAVE MODEL FXNQ20MAVE FXNQ25MAVE FXNQ32MAVE FXNQ40MAVE FXNQ50MAVE FXNQ63MAVE
Power supply 1-phase, 220-240 V/220 V, 50/60 Hz Power supply 1-phase, 220-240 V/220 V, 50/60 Hz
Btu/h 7,500 9,600 12,300 15,400 19,100 24,200 Btu/h 7,500 9,600 12,300 15,400 19,100 24,200
Cooling capacity Cooling capacity
kW 2.2 2.8 3.6 4.5 5.6 7.1 kW 2.2 2.8 3.6 4.5 5.6 7.1
Power consumption kW 0.049 0.090 0.110 Power consumption kW 0.049 0.090 0.110
Casing Ivory white (5Y7.5/1) Casing Galvanised steel plate
m3/min 7/6 8/6 11/8.5 14/11 16/12 m3/min 7/6 8/6 11/8.5 14/11 16/12
cfm 247/212 282/212 388/300 494/388 565/424 cfm 247/212 282/212 388/300 494/388 565/424
220 V 35/32 38/33 39/34 40/35 220 V 35/32 38/33 39/34 40/35
Sound level (H/L) dB(A) Sound level (H/L) dB(A)
240 V 37/34 40/35 41/36 42/37 240 V 37/34 40/35 41/36 42/37
Dimensions (H×W×D) mm 600×1,000×222 600×1,140×222 600×1,420×222 Dimensions (H×W×D) mm 610×930×220 610×1,070×220 610×1,350×220
Machine weight kg 25 30 36 Machine weight kg 19 23 27
Liquid (Flare) 6.4 9.5 Liquid (Flare) 6.4 9.5
Piping mm 12.7 15.9 Piping mm 12.7 15.9
Gas (Flare) connections Gas (Flare)
connections
Drain 21O.D. Drain 21O.D.
•Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
15955
61
59 57 56 62
60
58160
Indoor Unit Lineup VRV Indoor Units
Floor Standing Duct Type FXVQ-N Clean Room Air Conditioner FXB(P)Q-P
Flexible interior design for each tenant. Suitable for hospitals and
other clean spaces
accessory. * 8 hr/day, 26 day/month. For dust concentration of 0.15 mg/m3 Ceiling intake type Floor-level intake type
Type
(gentle wind distribution/high cleanness class model)
Construction work is simple and a ceiling installation is possible. Easy to increase the cleanness and air-conditioning effect.
Outdoor air intake mode is useable as an All-fresh (using outdoor air only) system Return + Outdoor air mixed system
Features
Outdoor air Outdoor air z Concentrated air conditioning centered z Total air conditioning with an emphasis
introduction introduction directly under the unit on cleanliness
z Easy installation
Intake
* Air introduced from the outside and circulated air must be mixed in the Integrated (sourced locally)
air conditioner primary side before introduction into the air conditioner. outlet unit
model
Applications: Surgery prep rooms, recovery rooms, nurse stations, etc. Applications: Operating theatres, delivery rooms, etc.
Blow
method
MODEL FXVQ125NY1 FXVQ200NY1 FXVQ250NY1 FXVQ400NY1 FXVQ500NY1 FXVQ500NY16 z Somewhat concentrated air conditioning z Total air conditioning with an emphasis
centered directly under the outlet on cleanliness
Power supply 3-phase 4-wire system, 380–415 V, 50 Hz z Can provide air conditioning in rooms with z Maintenance possible from a different
irregular shapes Outlet Air room
Separate
Btu/h 47,800 76,400 95,500 154,000 191,000 outlet unit
unit conditioner Intake
Cooling capacity (sourced locally)
*2: The value is the external static pressure with standard pulley.
63 57
61
16159 58 64
60162
62
Indoor Unit Lineup VRV Indoor Units
Filtration Type Integrated outlet unit model Separate outlet unit model
Indoor unit FXBQ40PVE FXBQ50PVE FXBQ63PVE FXBPQ63PVE
MODEL
(sold separately) Outlet unit Integrated with the indoor unit BAF82A63
Power supply 1-phase, 220-240 V/220 V, 50/60 Hz
Btu/h 15,400 19,100 24,200
Cooling capacity
kW 4.5 5.6 7.1
Power consumption kW 0.31 0.45
70% by gravimetric method
99.97% by DOP method *5
Indoor unit weight kg 140 *3 185 *3 120 *6
Casing Galvanised steel plate
m3/min 19.5/17.5 26/22.5
etc. Installation example (in a medical facility) (H/L)
cfm 688/618 918/794
Sound level (H/L) *4 dB(A) 44/42
* It may not be possible to maintain cleanliness in rooms with low air tightness. Dimensions (H×W×D) mm 492×1,788×1,000 492×1,788×1,300 492×1,078×1,300
Outlet unit weight kg – 65 *3
Liquid (Flare) 6.4 9.5
Piping 12.7 15.9
Gas (Flare) mm
Antibacterial connections
Drain PT1B
Suppresses the propagation of bacteria in the duct with a proprietary antibacterial coating Filter(Option) BAFH82A50 BAFH82A63
Panel Ceiling intake type Model BYB82A50C BYB82A63C BYB82A63CP
(Option) Floor-level intake type BYB82A50W BYB82A63W BYB82A63WP
organic antibacterial material that is effective against germs) that prevents mould.
This enhances the antibacterial properties of the duct. •Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
An antibacterial treatment using a silver-based organic substance reduces mould. Fan •Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.
(See Engineering Data Book for details.)
*4: Anechoic chamber conversion value under JIS B 8616 test conditions. Value usually increases slightly in practice due to surrounding conditions.
*5 : The clean room air conditioner does not support DOP testing (leak test) based on GMP standards (Standards for Manufacturing Control and
near the intake, cleaning performance is further enhanced. Quality Control for Medical Devices ) due to slight leakage at time of product installation.
*6: Weight including panel.
* Please be aware that antibacterial products suppress the propagation of bacteria but do not have a sterilizing effect.
Also, mould may grow in places where dust or soot accumulates. *In the case of an installation in an operating theatre etc. where an air conditioner malfunction may have serious consequences, please build
Outlet panel Sheet steel Intake panel in redundancy with two or more outdoor units.
law (Act on the Evaluation of Chemical Substances and Regulation of Their Manufacture, etc) is used for the
antibacterial material.
(punched) drain pan (punched)
(antibacterial treated)
Labor-saving
z Because the ceiling intake type provides concentrated air conditioning that blows directly under z
Easy access from underneath unit provides easy maintenance the outlet. Accordingly, please be aware of the following. type in the following kind of
locations.
• In the case of utilization in a hospital, some patients may be susceptible to cool drafts, so please ensure that they do • Locations in which heating of the
· Fan · Drip pan inspection not come directly under the outlet.
replacement inspection Warning • Install multiple units using two or more outdoor unit systems for installations to rooms such as operating rooms where
lower part or the entire room is
important.
of perspectives, including a service access system that eliminates the necessity the failure of the air conditioner may have serious consequences. • Locations necessitating a
• In order to maintain static pressure in a room, the indoor fan continues to operate even when an abnormality occurs
for service panels. due to the thermostat shutting off, defrost operation, protection device operation, or similar issue.
particularly high cleanliness
factor and in which there are
• When incorporating outdoor air from the fresh air intake, install a damper or similar device to the duct routing and many people.
have it interlocked with the indoor fan so that the outdoor air is shut out when the fan stops.
air conditioner operation.
• When using gas to disinfect hospital operating rooms where this unit is installed, stop operation and cover the air inlet
Quiet
All models incorporate an industry-leading quiet
design, operating at under 41dB
Operating noise is substantially reduced by employing a proprietary
65 59
163
63 61 60 66
62164
64
Indoor Unit Lineup Residential Indoor Units with Connection to BP Units
Standard accessory
Elegant appearance
Fan speed
Temperature control
5 steps, quiet and automatic
Microcomputer control
Note: Remote controllers
other than the standard with (H×W×D)
Dimensions European style
mm 200×700×620 200×900×620 200×1,100×620
accessory wireless remote Machine weight kg 21 25 27 30
controller cannot be used. Standard
Liquid (Flare) 6.4
Piping accessory
Gas (Flare) mm 9.5 12.7
connections
Drain VP20 (External Dia. 26/Internal Dia. 20)
Heat insulation Both liquid and gas pipes
Elegant
External static Appearance
pressure with Pa Curved Panel 30 40
Slim and smooth design suits your shallow ceiling Note: *The sleek design of the
The operation sound level values FTKJ-N
represent those forindoor unit
rear-suction features
operation and an external static pressure of 30 Pa for FDKS-EA and 40 Pa
for FDKS-C(A). Sound level values for bottom-suction operation can be obtained by adding 6 dB (A) for FDKS-EA and 5 dB (A) for FDKS-C(A).
a uniquely European style. This elegant body from blowing directly to a person’s body. During cooling
Models in the FDKS-EA series are only 700 mm in width Low operation sound level Standard accessory
(H/L/SL)
Note: Remote controllers houses state-of-the-art technology which delivers
and 21 kg in weight, made the installation easy in limited other than the standard
FDKS25 FDKS35 FDKS50 FDKS60
accessory wireless remote superior performance. impacts.
spaces. With only 200 mm in height, all models can be controller cannot be used.
installed in rooms with as little as 240 mm depth between
The FTKJ-N series
35/31/29 dB (A) 35/31/29 dB (A) 37/33/31 dB (A) 38/34/32 dB (A) offers a versatile
the drop ceiling and ceiling slab, making them ideal for
even shallow ceilings. choice for
Home Leave Operation prevents large increase or decrease in the
FDKS-EA home-owners,
Great for Slim and smooth design suits your shallow ceiling
hotel use!
indoor temperature by continuing operation* while someone is sleeping
or left the house. This means that an air-conditioned welcome awaits designers and
Models in the FDKS-EA series are only 700 mm in width Low
whenoperation soundup
someone wakes level
or returns. It also means that the indoor architects alike.
(H/L/SL)
and 21 kg in weight, made the installation easy in limited temperature can quickly return to the preferred comfort setting.
spaces. With only 200 mm in height, all models can be FDKS25 FDKS35 FDKS50 FDKS60
* Home Leave Operation can set to any temperature from 18 to 32˚C for cooling
installed in rooms with as little as 240 mm 200
depth
mm between 35/31/29
operation.dB (A) 35/31/29 dB (A) 37/33/31 dB (A) 38/34/32 dB (A)
the drop ceiling Only
and ceiling
700 mm slab, making them ideal for * Home Leave Operation function must be set by using the remote controller when going
even shallow ceilings.
to sleep or leaving the house, and after waking up or returning home. Two-Area Intelligent Eye
Home Leave Operation prevents large increase or decrease in the
circulates air to every part of a room for uniform cooling,
FDKS25EA FDKS-EA
FDKS35EA FDKS25CA FDKS35CA indoorAirtemperature
discharge duct* by continuing
Suspension operation*
bolt* Suction duct* while someone is sleeping
Great for
Dimensionshotel
(H x use!
W x D) 200 x 700 x 620 mm 200 x 900 x 620 mm
even for large spaces.
or left the house.
Air discharge grille* This means that an air-conditioned welcome awaits
Note:
receiver AIR * Locally obtained parts
1. To prevent an increase of the operation noise, avoid installing the air suction
grille directly below the suction chamber. MODEL FTKJ25NVMW FTKJ25NVMS FTKJ35NVMW FTKJ35NVMS FTKJ50NVMW FTKJ50NVMS
MODEL FDKS25EAVMB FDKS35EAVMB FDKS25CAVMB FDKS35CAVMB
2. Grilles, piping connections, FDKS50CVMB
ducts, and installation FDKS60CVMB
parts should be obtained
Power supply 1-phase, 220-240 V/220-230 V, 50/60 Hz
61
63
165
65 62
64 166
66
Indoor Unit Lineup Residential Indoor Units with Connection to BP Units
Wall Mounted Type FTKS-D/B/F BP Units for Connection to Residential Indoor Units
FTKS25D / FTKS35D
Standard accessory*
FTKS50B
Standard accessory*
Standard accessory*
* Remote controllers other than the standard accessory
wireless remote controller cannot be used.
Connectable to Residential Indoor Units Quiet Operating Sound
BP units allow VRV systems to be connected to Daikin’s Expansion valves tend to create refrigerant passing
Wall Mounted indoor units achieve quiet sound levels Titanium Apatite Deodorising Filter stylish and quiet residential indoor units. noise. However, this noise can be reduced by installing
of 22 dB (A). (H/L/SL)
apatite effectively adsorbs odours and allergens, ceiling or roof-space far from an indoor unit.
FTKS25D FTKS35D FTKS50F FTKS60F FTKS71F
as well as deodorises odours. Some Daikin residential indoor units also provide
37/25/22 dB (A) 39/26/23 dB (A) 43/34/31 dB (A) 45/36/33 dB (A) 46/37/34 dB (A) minimum sound levels of just 19 dB(A). Together these
Intelligent Eye with its infrared sensor features ensure your system continues to operate as
automatically controls air conditioner operation quietly as possible.
according to human movement in a room. When Titanium Apatite
Deodorising Filter
there is no movement, it adjusts the temperature BP unit
by 2˚C for energy savings.
Min. sound
level
19 dB(A)
combines Vertical
and Horizontal
Auto-Swing to
circulate air to every
part of a room for
uniform cooling of adsorption of odours and allergens and deodorisation
MODEL BPMKS967A3 BPMKS967A2
even large spaces. Power supply 1-phase, 220-240 V/220 - 230 V, 50/60 Hz
A uniform temperature of odours are only effective for substances which are Number of ports 3 (connectable to 1-3 indoor units) 2 (connectable to 1-2 indoor units)
* This function is available for is achieved throughout
the entire room. directly attached to the Titanium Apatite Deodorising Power consumption W 10
FTKS50/60/71F.
Filter. Running current A 0.05
Dimensions (HXWXD) mm 180X294 (+356*)X350
BPMKS967A3
16763
67 65 64
66168
68
Air Handling Unit Indoor
Air Unit Lineup
Treatment Equipment Lineup
Air Treatment
Equipment Lineup
3
2100 m3/h
be easily adjusted using a Without drain pump With drain pump
Daikin communication wire (F1, F2 communication) Liquid pipe *Refers to processing outdoor air close to indoor temperatureschange-over switch
and distributing inside
it indoor.
Other communication wire Gas pipe the electrical box to meet the 0–250
resistance in the duct
mm
Daikin air handling units can be connected to VRV systems. FXMQ200/250M system. 470 mm 470 mm
222 mm
This combination can be built to order as a system. Outdoor air series is also possible. Please contact your 25 mm
local sales office for details.
Indoor unit Indoor unit
69 65
16967 66 70
68170
Air Treatment Equipment Lineup
Outdoor-Air Processing Unit
• The unit introduces outdoor air and adjusts High-performance
;OL\UP[PU[YVK\JLZV\[KVVYHPYHUKHKQ\Z[Z • High-performance
filters with dustfilters
collection
with dust collection
the outdoor air thetemperature
outdoor airvia temperature
fixed discharge
via fixed discharge efficiencies (JIS
efficiencies
calorimetry)
(JISofcalorimetry)
90% and 65% of 90%
are and 65% are
temperature control,
temperature
therebycontrol,
reducing
thereby reducing the air also availablealso
the air as options.
available as options.
Combine fresh air treatment and air conditioning, supplied from a single system. conditioning load.conditioning load.
* The system can *operate
The system
with can
outdoor-air
operatetemperatures
with outdoor-air
ranging For the VRV system,
temperatures ranging For the VRVa system, a
Lineup MYVT[V͵/LH[PUNWLYMVYTHUJLPZZVTL^OH[HK]LYZLS`
from -5 to 43℃. Heating performance is somewhat adversely variety of control
variety
systems
of control systems
Model Name FXMQ125MFV1 FXMQ200MFV1 FXMQ250MFV1 HMMLJ[LK^OLU[OLV\[KVVYHPY[LTWLYH[\YLPZ͵VYILSV^
affected when the outdoor-air temperature is 0℃ or below. can be deployed, can beincluding
deployed, including
Capacity Index 125 200 250 * >OLUZOPWWLKMYVT[OLMHJ[VY`[OL[OLYTVZ[H[PZZL[H[͵
* When shipped from the factory, the thermostat is set at 18℃
remote control remote
from control from
for cooling. The set
fortemperature
cooling. Thecan
set be
temperature
varied within
canthe
be range
variedof
within the range of
13–25℃ during cooling operation, in the local setting modedistances
¶͵K\YPUNJVVSPUNVWLYH[PVUPU[OLSVJHSZL[[PUNTVKL\ZPUN using of up
distances
to 500 m. of up to 500 m.
the wired remote the
controller.
wired remote
The temperature,
controller. The
however,
temperature,
is not however, is *not Group control is*not
Group
possible
control
between
is not possible between
BRC1E63 BRC1E63
displayed on the remote
displayed controller.
on the remote controller. this unit and standard
this unit
typeand
indoor
standard Navigation
type indoorRemoteNavigation
Controller Remote Controller
* While in machine* While
protection
in machine
mode and protection
depending
modeonandoutdoor
depending
air on outdoor air Remote controllers
units. units. Remote
connectcontrollers
to (Wired connect tocontroller)
remote (Wired remote controller)
conditions, discharge
conditions,
air temperature
dischargemayair temperature
not be at themay each unit separately. (option)
set not be at the set each unit separately. (option)
temperature. temperature.
* The fan stops when
* Theoperating
fan stopsinwhen
defrosting,
operating
oil returning
in defrosting,
and hot ;OL¸ZLSMKPHNUVZPZM\UJ[PVU¹PUKPJH[LZ[OLVJJ\Y
oil returning and hot • The “self-diagnosis function” indicates the occur-
Fresh air treatment and air conditioning start operations. The
startfan
operations.
may stopThe duefan
to mechanical
may stop due protection
to mechanical protection
rence and nature rence ofand
abnormalities
nature of abnormalities
in the systemin the system
can be achieved with a single system by control. control.
by displaying by
codes
displaying
on the codes
remoteon
controller.
the remote controller.
using heat pump technology—without the
usual troublesome air supply and air Ceiling mounted
• Ceiling
ductmounted
units with
duct
three
units
different A central control
with three different • A central
system control system
discharge balance design. Fan coil units capacities arecapacities
available. are
These
available.
can beThese
connected
can be connectedcompatible with compatible
the VRV with the VRV
for air conditioning and an outdoor-air to VRV seriesto outdoor
VRV series
unitsoutdoor
to meet units to meet a variety system can be
a variety system
installed.
can be installed.
processing unit can be connected to the of different requirements.
of different requirements. * It is not possible* to
It is
change
not possible
the to change the
same refrigerant line. This results in discharge air temperature
dischargesettings
air temperature settings
enhanced design flexibility and significant Airflow rate from the central control
from thesystem.
central control system.
reduction in total system costs. FXMQ125MFV1FXMQ125MFV11,080 m3/ h 1,080 m*3/Do
h not associate* Do
thisnot
equipment
associate this equipment
Combination with VRV system FXMQ200MFV1FXMQ200MFV11,680 m3/ h 1,680 3 in areas which standard
m /h in areasindoor standard indoorDCS302CA61
whichunits units DCS302CA61
Central remote controller
Central remote controller
3 are installed, as central
are installed,
controlas central control
FXMQ250MFV1FXMQ250MFV12,100 m3/ h 2,100 m /h (option) (option)
cannot be used withcannot
them.be used with them.
6W[PVUHSLX\PWTLU[PUJS\KLZSVUNSPMLMPS[LYZ
• Optional equipment includes long-life filters. >P[O[OLVRV• With
system,
the VRV
the equipment
system, the
employs
equipment
the employs the
¸Z\WLY^PYPUNZ`Z[LT¹ZV[OH[[OL^PYPUNSPURPUN[OL
“super wiring system” so that the wiring linking the
*VTWH[PISL^P[OV\[KVVY[LTWLYH[\YLZMYVT͵[V
• Compatible with outdoor temperatures from -5℃ to and outdoor
indoor indoor units
and outdoor
can alsounits
be utilised
can also
forbe utilised for
͵ 43℃. central control.
central control.
Air conditioning and outdoor air processing can be accomplished using a single system.
Note: Note:
Usage LimitationsUsage Limitations
* Linked control of* Linked
the productcontroland ofthe
theHeat
product Reclaim
and the
Ventilator
Heat Reclaim
is Ventilator is
id 32
id 32
not supported. not supported.
ity
ity
VRV Outdoor Units
Re umi elat
* This equipment *isThis intended
equipment
for theistreatment
intended for of outdoor
the treatment
air only.of outdoor air only.
m
ive y
ive y
Hu
Hu
H R
H R
0%
0%
It is not to be used It is
fornot
maintaining
to be used indoor
for maintaining
air temperature,
indoor air temperature,
10
10
Installing or use withInstalling
standard or use
indoor
withunits.
standardBe sureindoor
to position
units. Bethe sure to position the
%
e e
ur ur
90
90
r at r at air discharge openings
air discharge
of the product
openings in positions
of the product
where inthe
positions
airflow where the airflow
Outdoor-Air Processing Unit pe pe
em Supported m Cooling Supported Cooling will not blow on people
Te B) will notdirectly.
blow onWhen people outdoor-air
directly. Whenprocessing
outdoor-air
is processing is
i r T ) i
Operation r
rA > r A W Range Operation Range
in excess, the unitinswitches
excess, the to thermo-off
unit switches mode, to thermo-off
and outdoor mode,
air and outdoor air
d oo ͵ d oo (℃
Indoor Unit Indoor Unit Ou
t
Ou
t
flows into the room flows
directly.
into the room directly.
t iv e * Fort ive outdoor ducts,
* Forbeoutdoor
sure to ducts,
providebeheat sureinsulation
to provide to heat
preventinsulation to prevent
Fan Fan idity la
Re ity ity la
Re ity
umid
Operation Hum
tOperation
ive 20% umid tive H 20% umcondensation.
id condensation.
R e la H R e la H
Heating
% tin
30ea
H g 30% * Group control of* the Group product
controland ofstandard
the product indoor
andunits
standard
is notindoor units is not
Supported Supported
pe ra tio n Range pe ra tio n Range supported. A separate
supported.
remote A controller
separate remote
should controller
be connectedshould to be connected to
O O
Air Outdoor –5 –5 15 19 15 19
(33.5) 43 (33.5)
individual unit. individual unit.
43
Conditioning Air Supply * The system will *not The operate
systeminwill fannot
modeoperate
wheninthe fanoutdoor
mode when air the outdoor air
Note: Note:
[LTWLYH[\YLPZ͵VYILSV^
temperature is 5℃ or below.
1. The data shown in1.theThegraph
data illustrates
shown in the the graphsupported illustrates operation the supported
ranges under operation ranges under
the following conditions.
the following conditions. * If the product is *utilised
If the product
to operate is utilised
24 hours to operate
a day, maintenance
24 hours a day, maintenance
Indoor and Outdoor IndoorUnit and Outdoor Unit (part replacement,(part etc.)replacement,
must be performed etc.) must periodically.
be performed periodically.
Effective piping length:Effective
7.5 m piping length: 7.5 m * Temperature setting * Temperature
and Powersetting Proportional
and Power Distribution
Proportional
(PPD)Distribution (PPD)
Height differential: 0Height
m differential: 0 m
are not possible even are notif the
possible
intelligent
evenTouch
if the Controller
intelligent Touch
or the Controller or the
2. The discharge temperature
2. The discharge
can be temperature
set using thecan remote be set controller.
using theHowever, remote controller. However,
the actual temperaturethe mayactual
nottemperature
match the temperature may not match setting under some setting under intelligent
the temperature some Touch Manager
intelligentisTouch
installed.
Manager is installed.
circumstances due to circumstances
the outdoor-air due processing
to the outdoor-air load or mechanicalprocessing load or mechanical * The remote controller
* The remote
wired tocontroller
the outdoor-air
wired toprocessing
the outdoor-air
unit processing unit
Connection Conditions protection controls. protection controls. must not be set as must
the not
master
be setremote
as thecontroller.
master remote Otherwise,
controller. Otherwise,
3. The system will not
3. The
operate
system
in fan willmode
not operate
when the in fan outdoor
modeair when temperature
the outdoor is air temperature is
^OLUZL[[V¸(\[V¹[OLVWLYH[PVUTVKL^PSSZ^P[JOHJJVYKPUN[V
when set to “Auto,” the operation mode will switch according to
The following restrictions must be observed in order to maintain the indoor units connected to the same system. ͵VYILSV^ 5℃ or below.
>OLUV\[KVVYHPYWYVJLZZPUN\UP[ZHYLJVUULJ[LK[OL[V[HSJVUULJ[PVUJHWHJP[`PUKL_T\Z[IL[VVM[OLJHWHJP[`PUKL_VM[OLV\[KVVY\UP[Z the outdoor air conditions,
the outdoor regardless
air conditions,
of the regardless
indoor temperature.
of the indoor temperature.
>OLUV\[KVVYHPYWYVJLZZPUN\UP[ZHUKZ[HUKHYKPUKVVY\UP[ZHYLJVUULJ[LK[OL[V[HSJVUULJ[PVUJHWHJP[`PUKL_VM[OLV\[KVVYHPYWYVJLZZPUN\UP[ZT\Z[UV[
exceed 30% of the capacity index of the outdoor units.
Because connection is possible depending on conditions ever when the capacity index of outdoor-air processing units exceeds 30% of the capacity index of the
outdoor units, contact your local distributor.
Outdoor-air processing units can be used without indoor units.
67
69 72 73 73 68
70
Air Treatment
Air Treatment
Equipment
Equipment
Lineup
Lineup Air Treatment Equipment Lineup
Standard
Standard
Specifications
Specifications Dimensions
Options
Indoor unitIndoor unit Air suction/discharge grille (Obtain locally)
C
mm
Dimensions (HxWxD)Dimensions (HxWxD) mm
470X744X1,100 470X744X1,100 470X1,380X1,100 470X1,380X1,100
Table of dimensions
B
A
SA Silencer (Option)
Motor output Motor kW
output kW 0.380 0.380 Duct
m3/min m3/min 18 18 28 28 35 35
(Obtain locally) Model A B C D
Fan Fan
Airflow rate Airflow rate
cfm cfm 635 635 988 988 1,236 1,236 FXMQ125MFV1 744 685 5X100=500 20- 4.7 hole
Thermal insulation material (Obtain locally)
External static pressure External static
220V/240V Papressure 220V/240V Pa185/225 185/225 225/275 225/275 205/255 205/255
D FXMQ200MFV1 1380 1296 11X100=1100 EA 32- 4.7 hole
(All around) OA
FXMQ250MFV1 1380 1296 11X100=1100 32- 4.7 hole
Air filter Air filter *2 *2 Option List
(Service space)
650 or more
Approx.
150
Liquid Liquidmm mm 9.5 (flare) 9.5 (flare)
Refrigerant Refrigerant Type Note:
VAM150 · 250 · 350 · 500 · 650 · 800 · 1000 · 1500 · 2000GJVE
piping Gas piping Gas mm mm15.9 (flare) 15.9 (flare) 19.1 (brazing) 19.1 (brazing) 22.2 (brazing) 22.2 (brazing) Item
Heat Reclaim Ventilator remote controller 1. The attached piping in the diagram is for FXMQ200MFV1 and
BRC301B61
Drain Drain mm mm PS1B female thread PS1B female thread
Residential central remote controller FXMQ250MFV1 only. The*1gas piping connection port ( 2 in the
DCS303A51
Machine weight Machine weight kg kg 86 86 123 123 Centralised diagram) has a different bore form with FXMQ125MFV1.
DCS302CA61
Sound level *3 Sound level *3
220V/240V dB(A) 220V/240V dB(A)42/43 42/43 47/48 47/48
controlling Central remote controller(Service 1100 or more
space) 2. An air filter DCS301BA61
is not supplied with this unit. Be sure to mount an air
Inspection hole 600 or more
device filter in the suction side. [Use a filter with dust collection efficiency
Connectable outdoorConnectable
units *4 outdoor units *4 6 HP and above 6 HP and above 8 HP and above 8 HP and above 10 HP and above 10 HP and above Schedule timer DST301BA61
of at least 50% (gravimetric method). This is available as an
Controlling device
Wiring adaptor for electrical 1 2 11 6 4 5
Operation range Operation range appendices option.] KRP2A61
(Fan mode operation between
(Fan15mode
andoperation
͵ Cooling
between 15 and 19℃) Cooling [V͵ 19 to 43℃ Discharge side
30 Suction side (Note.2) 3. For outdoor ducts, be sure to provide heat insulation to prevent
KRP50-2
PC Board Adaptor
condensation.
Range of the discharge
Range of the discharge Installation box for adaptor PCB KRP50-2A90 (Mounted electric component assy of Heat Reclaim Ventilator)
3X100=300
Cooling Cooling [V͵ 13 to 25℃
temperature *5 temperature *5 For heater
A Viewcontrol kit BRP4A50
470
FXFSQ-A
B View 1 Liquid pipe connection
FXDQ-PD 7 Power supply wiring connection FXLQ-MA FXBQ-P
Type
Note : *1. Specifications are
Notebased
: *1. Specifications
on the following areconditions;
based on the following conditions; *4. It is possible to connect
*4. to
It is
the
possible
outdoortounit
connect
if the total
to thecapacity
outdoorof unit
theifindoor
the total
units
capacity
is 50%oftothe indoor units is 50% to For wiring (VRV indoor unit) FXZQ-M FXUQ-A FXCQ-A FXEQ-A FXDSQ-A 2 Gas FXDQ-SP
pipe FXSQ-PA FXMQ-PA FXMQ-M8 FXMQ-P
connection FXHQ-MA FXHQ-A
Transmission wiring FXAQ-A
connection FXVQ-N
• Cooling: Outdoor temp. of 33℃DB, 28℃WB (68% RH), and discharge temp. of100%
*VVSPUN!6\[KVVY[LTWVM͵+)͵>)9/HUKKPZJOHYNL[LTWVM͵+) 18℃DB. of the capacity index
100% of the
of the
outdoor
capacity
unit.index of the outdoor unit. FXFQ-A
613 FXDQ-ND FXNQ-MA FXBPQ-P
3 Drain piping connection
50
,X\P]HSLU[YLMLYLUJLWPWPUNSLUN[O!TTOVYPaVU[HS
• Equivalent reference piping length: 7.5 m (0 m horizontal) *5. Local setting mode is *5.
notLocal
displayed
setting
onmode
the remote
is not displayed
controller. on the remote controller.
KRP1C11A KRP1BA57 —
760
KRP1B61 — KRP1C64 KRP1B56 — Hanger bracket
KRP1C64 KRP1B619 KRP1C13A KRP1BA54 — KRP1B61 KRP1C67 KRP1B61
*2. An intake filter is not supplied,
*2. An intake
so befilter
sure
is to
notinstall
supplied,
the optional
so be sure long-life
to install or optional long-life filter or ;OPZLX\PWTLU[JHUUV[ILPUJVYWVYH[LKPU[V[OLYLTV[LNYV\WJVU[YVSVM[OLVRV
filterthe • This equipment cannot be incorporated into the remote group system.
control of the VRV system. 4 Electric parts box 10 Discharge
Note 3 companion
Note 3 Noteflange
1100
high-efficiency filter. Pleasehigh-efficiency
mount it in the filter.
duct
Please
system
mount
of the
it insuction
the duct
side.
system of the suction side. Note 2, 3 Note 4 Note 2, 3 Note 3 Note 4 Note 2, 3 Note 2, 3 2, 3 —
Select a dust collection efficiency
Select a dust
(gravity
collection
method) efficiency
of 50% or(gravity
more. method) of 50% or more.
Installation box for adaptor PCB KRP1H98A KRP1BA101 KRP1BA97 KRP1B96 — BRP9A90 KRP1BA101
5 Ground— terminal
KRP4A98 KRP4A97 11—Water KRP1CA93
supplyKRP1D93A
port KRP4AA93
*3. Anechoic chamber conversion
*3. Anechoic
value,
chamber
measured conversion
at a point
value,
1.5 m measured
downward at afrom
point
the1.5
unit
m centre.
downward from the unit centre. 3 6 Name plate 12 Attached piping (Note. 1)
These values are normally These
somewhat
valueshigher
are normally
during somewhat
actual operation
higherasduring
a resultactual
of ambient
operation as a result of ambient
conditions. conditions. 2.
* box isdiagrams
Note: 1. InstallationThese necessaryare
for based
each adaptor marked and
on FXMQ200 . *1 For residential use only. When connect with a Heat Reclaim Ventilator (VAM), you can
FXMQ250MFV1.
only switch the power ON/OFF. It cannot be used with other central control equipment.
3. Only one installation box can be installed for each indoor unit.
4. Up to 2 installation boxes can be installed for each indoor unit.
FXMQ200/250MFV1 FXMQ125MFV1
Options
Options
Type VAM150GJVE 245
Item 12 VAM350GJVE VAM500GJVE VAM650GJVE VAM800GJVEVAM250GJVE
60
61
VAM1000GJVE VAM1500GJVE VAM2000GJVE
Silencer — KDDM24B50 KDDM24B100 KDDM24B100X2
Additional
function
Nominal pipe diameter mm — 200 250
3X100=300
3X100=300
KAF242J25M KAF242J50M KAF242J65M KAF242J80M KAF242J100M KAF242J80MX2 KAF242J100MX2
360
330
360
330
Indoor unitIndoor unit KAF241J25M KAF241H50M KAF241J65M KAF241J80M KAF241J100M KAF241J80MX2 KAF241J100MX2
390
390
296
296
250
250
25
25
Flexible duct (1 m) K-FDS101D K-FDS151D K-FDS201D K-FDS251D
Flexible duct (232-
m) 7 hole K-FDS102D K-FDS152D K-FDS202D
20- 7 hole 5X100=500
K-FDS252D
Model Model FXMQ125MFV1 FXMQ125MFV1 FXMQ200MFV1 FXMQ200MFV1 FXMQ250MFV1 FXMQ250MFV1 11X100=1100
(All around) — (All around) YDFA25A1
Operation remote controller
Operation remote controller BRC1E63/BRC1C62 BRC1E63/BRC1C62
Duct adaptor 1200
1230
30
8 —
600 30
8 250
Nominal pipe diameter mm 630
Operation/control
Operation/control
200
360
346
200
360
330
250
250
Wiring adaptor for electrical
Wiringappendices
adaptor for(2)electrical appendices (2) KRP4AA51 KRP4AA51
Long-life replacementLong-life
filter replacement filter KAFJ371L140 KAFJ371L140 KAFJ371L280 KAFJ371L280 PC board adaptor for heater control kit (BRP4A50) 5X200=1000 2X200=400
High-efficiency Colourimetric
High-efficiency Colourimetric methodKAFJ372L140
method 65% 65% KAFJ372L140 KAFJ372L280 KAFJ372L280 7 7 580
Filters
Filters
1230
filter filter
When the installation of an electric heater is required in a cold region, this adaptor with an internal timer function eliminates the
16-M5 hole 10-M5 hole 630
Colourimetric Colourimetric methodKAFJ373L140
method 90% 90% KAFJ373L140 KAFJ373L280 KAFJ373L280
complicated timer connecting
(All around) work that was necessary with conventional heaters.
B View (For FXMQ200MFV1)
(All around)
Filter chamber *1 Filter chamber *1 KDJ3705L140 KDJ3705L140 KDJ3705L280 KDJ3705L280 B View
PM2.5 filtration unit *2PM2.5 filtration unit *2 BAF429A20A BAF429A20A Notes when installing
1004 Indoor Outdoor
PM2.5 with activatedPM2.5
carbonwith activated
filtration carbon filtration unit *2
unit *2 BAF429A20AC BAF429A20AC
using the electric heater based on the standard and
Drain pump kit Drain pump kit KDU30L250VE KDU30L250VE RA EA regulation of each country.
200
360
330
Adaptor for wiring Adaptor for wiring KRP1B61 KRP1B61 Heat Reclaim Ventilator Supply the electric heater and safety production devices
250
69
71 74 74 183
75 70
72
Air Treatment Equipment Lineup
HEP Element
(Anti-mould)
Air Supply Fan
SA
(Supply air to room)
Operation of the heat exchanger element Electronics Box
(Control box)
DX-coil
Outdoor Indoor
30.6°C SA
62% RH 27.4°C
63% RH
airflow colliding people directly during cooling 32°C DX-coil (Direct expansion coil)
70% RH
operation, due to the after-cool operations
Integrally-formed liner
Daikin Electrostatic
Heat Reclaim Ventilator with Normal Filtration
Dust Collecting
DX Coil Filtration
Efficient fresh outdoor air supply with heat exchange and cooling operation.
Outdoor Air
Air Treatment
Equipment Lineup
Connection Conditions • Ventilation and cooling are possible with one remote controller.
The following restrictions must be observed in order to maintain the indoor units connected to the same system. –5 0 5 10 15 20 25 30 35 40
continuous
• When Supply
the Heat Reclaim Air isVKM
Ventilator guaranteed.
series units are connected, the total connection capacityand
indexthus ventilation
must be 50% to 130%effect is reduced.
of the capacity index of the outdoor units.
Dry bulb temperature (°CDB)
17571
73 76 72
74176
Air Treatment Equipment Lineup
Specifications Dimensions
Refrigerant
MODEL VKM50GAV1 VKM80GAV1
R-410A
VKM100GAV1
VKM50/80/100GAV1
Power Supply 1-phase, 220–240 V, 50 Hz
Airflow rate m³/h 500 750 950 Supply air fan Damper plate Direct expansion coil Hanger bracket
Ultra-high 387
1688
4-14 x 40 oval hole
Static pressure Pa 180 170 150 Exhaust air fan 160
235
20
Airflow Rate & Static Airflow rate m³/h 500 750 950
Pressure (Note 6) High
Static pressure Pa 150 120 100
D
B
Airflow rate m³/h 440 640 820 RA
Low EA Return air from room
Static pressure Pa 110 80 70 Exhaust air to outdoors 210
E
G
560 620 670
A
Heat Ultra-high
C
exchange High W 490 560 570 SA
mode 420 470 480 Supply air to room
Low OA
34
42
153
Power Consumption
560 620 670 Fresh air from outdoors
Ultra-high (Outdoor air)
130
Bypass
20
High W 490 560 570
60
More than 600
mode 153 160
Low 420 470 480 28
150– 250
Maintenance Cover
94
Fan Type Sirocco Fan Control box
Inspection Inspection 144
Motor Output kW 0.280 x 2 0.280 x 2 0.280 x 2 Maintenance cover
hatch hatch 210
Ultra-high 38/38.5/39 40/41/41.5 40/40.5/41
Heat
Maintenance space for the heat exchanger elements 360 (In case of 450 inspection hatch)
exchange High dB(A) 36/36.5/37 37.5/38/39 38/38.5/39 the air filters, fans 140 (In case of 600 inspection hatch)
mode Low 33.5/34.5/35.5 34.5/36/37 35/36/36.5
Sound Level (Note 4)
(220/230/240 V) Ultra-high 38/38.5/39 40/41/41.5 40/40.5/41
Bypass
High dB(A) 36/36.5/37 37.5/38/39 38/38.5/39 H 1764 I
mode
VKM50GAV1 VKM80/100GAV1 10 515
Low 33.5/34.5/35.5 34.5/36/37 35/36/36.5
A 832 1,214 High efficiency filter (option) 322
Ultra-high 76 78 74
B 248 439
Temp. Exchange High % 76 78 74 C 431 622
Efficiency
D 164 183
K
J
Low 77.5 79 76.5
E 420 592
Ultra-high 64 66 62 F 248 439
Enthalpy Exchange 64 66 62 G 878 1,262 Heat exchanger
High % Gas pipe * The specification subject to change without notice.
Efficiency (Cooling) H 137 89 elements * Be sure to provide two inspection hatch.
connection
Low 67 68 66 I 137 89 Air filters ( 450 or 600) at the service side of filters and elements.
(ø12.7)
* The high efficiency filter (option) can be attached to the SA surface
Ultra-high 67 71 65 J ø196 ø246 Liquid pipe connection Drain outlet
of the heat exchanger elements.
Enthalpy Exchange K ø250 ø263 (ø6.4) (PT3/4 male screw)
High % 67 71 65
Efficiency (Heating)
Low 69 73 69
Casing Galvanised Steel Plate
Insulating Material Self-Extinguishable Urethane Foam
Heat Exchanging System Air to Air Cross Flow Total Heat (Sensible + Latent Heat) Exchange
Options
Heat Exchanger Element Specially Processed Nonflammable Paper
Air Filter Multidirectional Fibrous Fleeces
Controlling device
Schedule timer DST301BA61
Around Unit 0°C–40°CDB, 80%RH or less
Wiring adaptor for electrical KRP2A61
Unit Ambient Condition OA (Note 7) -15°C–40°CDB, 80%RH or less appendices
PC Board Adaptor
RA (Note 7) 0°C–40°CDB, 80%RH or less For humidifier running ON signal output KRP50-2
Note: 1. Cooling and heating capacities are based on the following conditions. Fan is based on High and 10. Temperature exchange efficiency is the mean value for Cooling and Heating. Efficiency is measured
For heater control kit BRP4A50
Ultra-high. under the following condition: Ratio of rated external static pressure outdoor to indoor is kept Type FXFSQ-A FXDQ-PD FXLQ-MA FXBQ-P
When calculating the capacity as indoor units, use the following figures: constant at 7 to 1.
For wiring (VRV indoor unit) FXZQ-M FXUQ-A FXCQ-A FXEQ-A FXDQ-SP FXSQ-PA FXMQ-PA FXMQ-M FXHQ-MA FXHQ-A FXAQ-A FXVQ-N
VKM50GAV1: 3.5 kW, VKM80GAV1: 5.6 kW, VKM100GAV1: 7.0 kW 11. When connecting with a VRV system heat recovery outdoor unit and bringing the RA (exhaust gas FXFQ-A FXDQ-ND FXNQ-MA FXBPQ-P
2. Indoor temperature: 27°CDB, 19°CWB, Outdoor temperature: 35°CDB intake) of this unit directly in from the ceiling, connect to a BS unit identical to the VRV indoor unit
3. Indoor temperature: 20°CDB, Outdoor temperature: 7°CDB, 6°CWB (master unit), and use group-linked operation. (See the Engineering Data for details.) KRP1C11A KRP1BA57 — KRP1B61 — KRP1B56 — KRP1C64 KRP1B61 KRP1BA54 — KRP1B61 KRP1C67 KRP1B61
4. The operating sound measured at the point 1.5 m below the centre of the unit is converted to 12. When connecting the indoor unit directly to the duct, always use the same system on the indoor Note 2, 3 Note 4 Note 2, 3 — Note 4 — Note 2, 3 Note 2, 3 — Note 3 Note 3 Note 2, 3 —
that measured in an anechoic chamber built in accordance with the JIS C 1502 conditions. The unit as with the outdoor unit, perform group-linked operation, and make the direct duct connection Installation box for adaptor PCB KRP1H98A KRP1BA101 KRP1BA97 KRP1B96 KRP1BA101 KRP4A98 KRP4A97 KRP1CA93 KRP1D93A KRP4AA93
actual operating sound varies depending on the surrounding conditions (near running unit’s settings from the remote controller. (Mode No. “17 (27)” – First code No. “5” – Second code No.
sound, reflected sound and so on) and is normally higher than this value. “6”.) Also, do not connect to the outlet side of the indoor unit. Depending on the fan strength and
For operation in a quiet room, it is required to take measures to lower the sound. static pressure, the unit might back up. Note: 1. Installation box « is necessary for each adaptor marked « . *1 Necessary when operating a Heat Reclaim Ventilator (VKM) independently. When operating interlocked
For details, refer to the Engineering Data. 2. Up to 2 adaptors can be fixed for each installation box. with other air conditioners, use the remote controllers of the air conditioners.
5. The noise level at the air discharge port is about 8–11 dB(A) or higher than the unit’s operating 3. Only one installation box can be installed for each indoor unit. *2 For residential use only. When connected with a Heat Reclaim Ventilator (VKM), you can only switch
sound. 4. Up to 2 installation boxes can be installed for each indoor unit. the power ON/OFF, it cannot be used with other central control equipment.
For operation in a quiet room, it is required to take measures to lower the sound.
6. Airflow rate can be changed over to Low mode or High mode.
7. OA: fresh air from outdoor. RA: return air from room.
8. Specifications, design and information here are subject to change without notice.
Air Treatment
Equipment Lineup
9. Power consumption and efficiency depend on the above value of airflow rate.
Type VKM50GAV1 VKM80GAV1 VKM100GAV1
Item
— KDDM24B100
Additional function
Silencer
Nominal pipe diameter mm — 250
Air suction/ White K-DGL200B K-DGL250B
Discharge grille Nominal pipe diameter mm 200 250
High efficiency filter KAF242J80M KAF242J100M
Air filter for replacement KAF241G80M KAF241G100M
Flexible duct (1 m) K-FDS201D K-FDS251D
Flexible duct (2 m) K-FDS202D K-FDS252D
17773
75 74
76178
Air Treatment Equipment Lineup
Heat Reclaim Ventilator — VAM series Air conditioning load reduced by approximately 31%!
40 m
SA
by not operating the Heat
comfortable environment. Precise, thin-film
material Reclaim Ventilator while air is
EA Outdoor air still clean soon after the air
RA
1 For models: VAM150/250/350/650/800/1000/2000GJVE (Exhaust air to outdoors) (fresh air) Supply air Low-humidity air
31%
Air Treatment
Equipment Lineup
• Calculated for air conditioning sensible heat load only
Cold Climate Compatible (latent heat load not included).
Heat is discharged. The load is small so the temperature is rapidly reduced
306 mm to a comfortable level.
Standard operation at *Interlocked operation with an air conditioner
-15˚CDB 50˚CDB
temperatures down to
* For VAM500GJVE -15°C.
-20 -10 0 10 20 30 40 50
17975
77 76
78180
Air Treatment Equipment Lineup
(50/60 Hz) Ultra-High 28.5-29.5/29.5 28.5-30.5/30.5 33-34.5/34.5 34.5-36/35.5 35-37.5/37.5 40.5-42/41 40.5-42.5/40.5 41-43/42.5 43-45.5/44
Airflow up Bypass
High dB(A) 27.5-28.5/28.5 27.5-29/29.5 31.5-33/31.5 33-34.5/33.5 33-35.5/35.5 38.5-40/39 38.5-40.5/38.5 39.5-41/41.5 40.5-45/42
Mode
Low 22.5-23.5/22 22.5-23/22.5 24.5-26.5/24.5 25.5-28.5/25.5 27.5-30.5/29.5 36-38.5/35.5 36-38.5/35.5 36.5-38/37.5 37.5-39.5/41
indicates energy savings! Casing Galvanised steel plate
Airflow up Energy wastage for ventilation is reduced.
Air conditioning load for ventilation is reduced. Insulation Material Self-extinguishable polyurethane foam
Dimensions (HXWXD) mm 278X810X551 306X879X800 338X973X832 387X1,111X832 387X1,111X1,214 785X1,619X832 785X1,619X1,214
9 10 11 12 13 14 15 16 17 18 19 20 21 Hours Machine Weight kg 24 32 45 55 67 129 157
Heat Exchange System Air to air cross flow total heat (Sensible heat + latent heat) exchange
Sales Sales
Morning Lunch Overtime Heat Exchange Element Material Specially processed nonflammable paper
personnel leave personnel
meetings time work
office return Air Filter Multidirectional fibrous fleeces
Type Sirocco fan
Ultra-High 150/150 250/250 350/350 500/500 650/650 800/800 1,000/1,000 1,500/1,500 2,000/2,000
Airflow Rate
High m3/h 150/150 250/250 350/350 500/500 650/650 800/800 1,000/1,000 1,500/1,500 2,000/2,000
(50/60 Hz)
Low 100/95 155/155 230/230 320/295 500/470 700/670 860/840 1,320/1,260 1,720/1,580
Fan
Ultra-High 120/154 70/96 169/222 105/150 85/125 133/170 168/192 112/150 116/140
Heat Reclaim Ventilator External Static
Pressure High Pa 106/131 54/65 141/145 66/52 53/67 92/85 110/86 73/72 58/32
Air conditioner (50/60 Hz)
Low 56/60 24/20 67/30 32/18 35/38 72/61 85/60 56/50 45/45
Motor Output kW 0.030X2 0.090X2 0.140X2 0.280X2 0.280X4
Connection Duct Diameter mm 100 150 200 250 350
Many people increase CO2 level: Fewer people decrease CO2 level: Unit ambient condition -15°C–50°CDB, 80%RH or less
Note : 1. Sound level is measured at 1.5m below the centre of the body. 10. With large models in particular (1500 and 2000m3/h models), if the supply air
Airflow up Airflow down 2. Airflow rate can be changed over to Low mode or High mode.
3. Sound level is measured in an anechoic chamber.
(SA) grille is installed near the main unit, the noise of the main unit may be heard
from the discharge grille via the duct, and this will result in a marked increase in
Sound level generally becomes greater than this value depending on the noise. In such cases, if peripheral effects are included (such as reverberation of
operating conditions, reflected sound, and peripheral noise. the floor and walls, combination with other equipment, and background noise),
4. The sound level at the air discharge port is about 8 dB(A) higher than the unit's sound level may be as much as 15 dB(A) higher than the indicated value. When
sound level. installing a large model, please provide as much separation as possible between
5. The specifications, designs and information given here are subject to change the main unit and the discharge grille. If the equipment and discharge grille are
without notice. near each other, please consider countermeasures such as the following:
6. Temperature Exchange Efficiency is the mean value between cooling and heating. • Use a sound-muffling box, flexible duct and sound-muffling air supply/discharge
7. Efficiency is measured under the following conditions: grilles
Ratio of rated external static pressure has been maintained as follows; outdoor • Decentralised installation of discharge grilles
side to indoor side = 7 to 1. 11. When installing in a location with particularly low background noise such as a
8. In conformance with JIS standards (JIS B 8628), operating sound level is based on the classroom, please consider the following measures to avoid transmission sound
value when one unit is operated, with the value converted for an anechoic chamber. from the main unit:
This is transmission sound from the main unit, and does not include sound from • Use of ceiling materials with high sound insulating properties (high transmission
the discharge grille. Thus it is normal for the sound to be louder than the loss)
indicated value when the unit is actually installed. • Methods of blocking sound transmission, for example, by adding sound
9. Sound level from the discharge port causes the value to be approximately 8 insulating materials around the bottom of the sound source.
dB(A) (models with the airflow rate of less than 150 to 500m3/h) to approximately Alternatively, consider supplementary methods such as installing the equipment
Air Treatment
Equipment Lineup
11 dB(A) (models with the airflow rate of 650m3/h or more) greater than the in a different location (corridor, etc.)
indicated value. Furthermore, fan rotation and noise from the discharge grille
may increase depending on the on-site duct resistance conditions. Please
consider noise countermeasures when installing the unit.
18177
79 78
80182
Air Treatment Equipment Lineup
Dimensions
Options (Option) for VAM / FXMQ-MF series
Air suction/discharge grille (Obtain locally) Rapid urbanization has increased industrial and automobile emissions, resulting in higher PM2.5 levels.
This has become the source of respiratory diseases and poses a serious threat to a long term health
FXMQ125/200/250MFV1 Flexible duct
(Option) issue. As the air quality has worsened, research has shown the harmful effects of PM2.5 on the health
9 1148
RA Local connection piping size of the general public.
(Option)
10 SA
Model Gas piping diameter Liquid piping diameter
FXMQ125MFV1 15.9 9.5
FXMQ200MFV1 19.1 attached piping 9.5
FXMQ250MFV1 22.2 attached piping Round hood 9.5
Branch duct (Obtain locally)
(Obtain locally)
C
Table of dimensions
B
A
SA Silencer (Option)
Duct
(Obtain locally) Model A B C D
FXMQ125MFV1 744 685 5X100=500 20- 4.7 hole
Thermal insulation material (Obtain locally)
D FXMQ200MFV1 1380 1296 11X100=1100 EA 32- 4.7 hole
(All around) OA
FXMQ250MFV1 1380 1296 11X100=1100 32- 4.7 hole
Option List
(Service space)
650 or more
Approx.
150
Type Note:
VAM150 · 250 · 350 · 500 · 650 · 800 · 1000 · 1500 · 2000GJVE
Item
Heat Reclaim Ventilator remote controller 1. The attached piping in the diagram is for FXMQ200MFV1 and
BRC301B61
Residential central remote controller FXMQ250MFV1 only. The*1gas piping connection port ( 2 in the
DCS303A51
Centralised diagram) has a different bore form with FXMQ125MFV1.
DCS302CA61
controlling Central remote controller(Service 1100 or more
2. An air filter DCS301BA61
is not supplied with this unit. Be sure to mount an air
device Inspection hole 600 or more
space)
filter in the suction side. [Use a filter with dust collection efficiency
Front Filter
Schedule timer DST301BA61
of at least 50% (gravimetric method). This is available as an
Controlling device
condensation.
Installation box for adaptor PCB KRP50-2A90 (Mounted electric component assy of Heat Reclaim Ventilator)
3X100=300
For heater
A Viewcontrol kit BRP4A50
470
FXFSQ-A
B View
FXDQ-PD 1 Liquid pipe connection
FXDQ-PD 7 Power supply wiring connection FXLQ-MA
FXLQ-MA FXBQ-P
FXBQ-P
Type
For wiring (VRV indoor unit) FXZQ-M FXUQ-A
FXZQ-M FXUQ-AFXCQ-AFXCQ-AFXEQ-A
FXEQ-A
FXDSQ-A 2 Gas FXDQ-SP
pipeFXSQ-PA
FXDQ-SP FXSQ-PA
connection FXMQ-PA FXMQ-M
FXMQ-M FXHQ-MAFXHQ-MA
8 FXMQ-P
Transmission FXHQ-AFXHQ-AFXAQ-A
wiring FXAQ-A
connection FXVQ-N
FXVQ-N
FXFQ-A
613 FXDQ-ND
FXDQ-ND FXNQ-MA
FXNQ-MA FXBPQ-P
FXBPQ-P
3 Drain piping connection
50
9 Hanger bracket
760
KRP1BA57 — — KRP1B61
KRP1C11A KRP1BA57 KRP1B61— — KRP1C64KRP1B56KRP1B56 —— KRP1C64 KRP1B61
KRP1C64 KRP1B61KRP1C13A KRP1BA54 — — KRP1B61
KRP1BA54 KRP1B61KRP1C67
KRP1C67KRP1B61
KRP1B61
4 Electric parts box 10 Discharge 3 companion 3 flange
1100
Note4 4
Note 2, 3 Note Note Note
2, 3 2, 3 — —Note 3 NoteNote
4 4 Note
Note2,2,3 3 Note 2, 3
—— terminal Note 3 NoteNote
—11—Water 3 Note 3Note 2,Note 2, 3 ——
Installation box for adaptor PCB KRP1H98A KRP1BA101 KRP1BA97KRP1B96
KRP1BA101 KRP1BA97 KRP1B96 5 Ground
KRP1BA101
BRP9A90 KRP1BA101 KRP4A98 KRP4A97
KRP4A98 supply
KRP1CA93KRP1CA93
KRP1D93Aport KRP4AA93
KRP1D93A KRP4AA93
3 6 Name plate 12 Attached piping (Note. 1)
2.
* box isdiagrams
Note: 1. InstallationThese necessaryare
for based
each adaptor marked and
on FXMQ200 . *1 For residential use only. When connect with a Heat Reclaim Ventilator (VAM), you can
FXMQ250MFV1.
only switch the power ON/OFF. It cannot be used with other central control equipment.
3. Only one installation box can be installed for each indoor unit.
4. Up to 2 installation boxes can be installed for each indoor unit.
FXMQ200/250MFV1 FXMQ125MFV1
Type VAM150GJVE 245
Item 12 VAM350GJVE VAM500GJVE VAM650GJVE VAM800GJVE VAM250GJVE
60
61
VAM1000GJVE VAM1500GJVE VAM2000GJVE
Silencer — KDDM24B50 KDDM24B100 KDDM24B100X2
Additional
3X100=300
360
330
390
296
296
250
250
25
25
250
250
7 1230 7 580
When the installation of an electric heater is required in a cold region, this adaptor with an internal timer function eliminates the
16-M5 hole 10-M5 hole
complicated timer connecting
(All around) work that was necessary with conventional heaters. (All around)
630
With the capturing effect of static electricity,
B View (For FXMQ200MFV1) B View
Air Treatment
Equipment Lineup
RA EA
200
360
330
Heat Reclaim Ventilator Supply the electric heater and safety production devices
250
18379
75 81 80 76
82184
Air Treatment Equipment Lineup
The special substance added in the pores of active carbon can exclusively
target sulfur oxide and nitrogen oxide gases and stick to them without
Adhesives
Air Treatment
Equipment Lineup
18581
77 83 82
8478
186
Control Systems
Navigation Remote Controller (Wired remote controller) (Option) Convenience Setback Recovery
temperature differential
•Setback (default: OFF)
This simple, modern designed remote controller with fresh white colour Cooling 33 37ºC -2 -8ºC
Maintains the room temperature in a specific range during unoccupied period
matches your interior design. Operation is much easier and smoother, just by temporarily starting air conditioner that was turned OFF.
follow the indications on the navigation remote controller.
Ex) Setback temperature Cooling : 35ºC Recovery differential Cooling : -2ºC
When the room temperature goes above 35ºC, the air conditioner starts operating in Cooling automatically.
When room temprature reaches 33ºC, the air conditioner returns OFF.
BRC1F61
(Only for FXEQ series)
Simple operation
•Large buttons and arrow keys
•Auto display off
· Large buttons and arrow keys enable easy operation. Basic setting such as fan
· While operation is stopping, LCD display can be turned OFF. It will be displayed again if any button is pressed.
speed and temperature can be intuitively operated. For other settings, select the
· Period can be preset from 10, 30, 60 minutes, and OFF. Initial setting is 30 minutes.
function from the menu list.
•Guide on display
· The display gives an explanation of each setting for easy operation.
Comfort
•Individual airflow direction (*1)
Airflow direction can be individually adjusted for each air discharge outlet to deliver optimal air distribution that conforms to
Energy saving conditions for airflow direction (small and large loads).
*1. Only available for FXF(S)Q-A, FXCQ-A and FXUQ-A series.
•Setpoint range set •Setpoint auto reset
· Saves energy by limiting the min. and max. · Even if the set temperature is changed, the new set •5-step airflow control (*2)
set temperature. temperature returns to the previous preset value Control of airflow rate can be selected from 5-step control, which provides comfortable airflow.
· Avoids excessive cooling. after a preset duration of time. *2 . The number of airflow steps differs according to the type of indoor unit. 5-step airflow is only available for FXF(S)Q-A,FXCQ-A, FXEQ-A and FXDSQ-A series.
· This function is convenient when the remote · Period selectable from 30, 60, 90, or 120 min.
controller is installed at a place where •Auto airflow rate (*3)
any number of people may operate it. Airflow rate is automatically controlled in accordance to the difference between room temperature and set temperature.
Restaurant sample *3 .Only available for FXF(S)Q-A, FXCQ-A, FXEQ-A, FXDQ-PD/ND, FXSQ-PA, FXMQ-PA, FXUQ-A and FXAQ-A series.
Control
Systems
•Off timer
· Turns off the air conditioner after a preset
period of time.
· Period can be preset from 30 to 180 minutes *Preset-return time can be set
at 30, 60, 90, or 120 min
in 10-minute increments.
18783
85 86188
84
Control Systems
Individual Control Systems for VRV Systems Wide variation of remote controllers for VRV indoor units
FXFSQ FXFSQ
FXFQ FXZQ
FXFQ FXUQ
FXZQ FXUQ
FXCQ FXCQ
FXEQ FXDSQ
FXEQ FXDQ FXSQ FXMQ FXHQ FXAQ FXL(N)Q FXVQ FXB(P)Q
Simple operation
(BRC2E61)
•Using only six buttons, users have direct
access to basic functions. Wireless remote controller*
(Installed type signal receiver unit)
This enables them to easily set comfort to their
preference.
BRC2E61 Wireless remote controller*
(Separate type signal receiver unit)
·ON/OFF ·Operation mode
*Refer to page 100
211 for the name of each model.
·Temperature setting
•Group control
Intuitive design Equipment One remote controller can control the
Outdoor related to the operation of max.16 indoor units at
•By using pictograms, the user-friendly interface enables operation is much easier and unit the same time.
central control
smoother.
Compact size
•Measuring only 85 x 85 mm, the new remote controller is extremely compact and Indoor unit
Remote controller
complements any interior design.
Remote controller
1 2 3 4
Control
Systems
3 Control for the combined operation 4 Expansion of system control
Signal receiver unit The operation of Heat Reclaim Ventilator can be controlled The system can be expanded to add several controllers,
(Separate type) by the remote controller of the indoor unit. Of course, the such as BMS, Forced OFF input and etc.
BRC-C, E series
18985
81 87 86
88190
82
Control Systems
(DCS601C51)
Heat Reclaim Ventilator
(DCM601A51)
Via internet
Residential central
remote controller D -NET Interface Adaptor for SkyAir Series
(DCS303A51) SkyAir
(High Speed Multiple (DTA112BA51)
Transmission)
Via internet
* No adaptor is required for
some indoor units.
ACC Centre Control /Connection Interface
Central Control Adaptor Kit
Air Conditioning Network Service System DIII-NET, Daikin’s unique Packaged
(DTA107A55) Air-conditioner
(There are restrictions in applicable areas and Unification adaptor high speed multiple
release times, therefore please consult us for computerised control transmission system, links
separately for details.) (DCS302A52) air conditioners
(Optional Maintenance Service) and various other building
Home Automation
equipment—in
Master Controller accordance with Interface Adaptor for DIII-NET use
applications, scale and (KRP928BB2S)
Home Automation conditions—and transmits Residential Air-conditioner
Interface Adaptor vast amounts of
(DTA116A51) information between
BMS
them.
(Obtain locally)
VRV Caution:
Limitation may apply to some models and functions. Please contact your local sales office for details.
Consultation is necessary before employing this control system. Please contact your local sales office before
making a purchase.
Wiring adaptor Note: BACnet® is a registered trademark of American Society of Heating, Refrigerating and Air-Conditioning
for electrical appendices Engineers (ASHRAE). LONWORKS® is a trademark of Echelon Corporation registered in the United
(KRP2A61/62/53) States and other countries.
83 87
89 88
90 84
Control Systems
intelligent Touch Manager is an advanced multi-zone controller that provides the most cost-effective way to
control and monitor the Daikin VRV system.
The 10.4" LCD touch screen is easy to use with three different screen views to include the floor plan layout
view, icon view and list view and menus for system configurations.
It is also easy to use with standardized remote Web Access from your PC.
It can manage a total of 650 management points consisting of up to 512 Daikin indoor unit groups
(up to 1024 indoor units) along with building equipment control / monitoring with Digital Inputs / Output
DCM601A51 (Di/Dio), Analog Inputs / Output (Ai/Ao) and Pulse input (Pi) optional devices.
It can not
Why? be set
Common area: below this Oh! Cool.
Lighting control DALI-compatible
DALI-compatible Meeting room: 9:00-17:00
No schedule
DALI-compatible LED lighting systems can be
controlled and monitored. Lighting control is enhanced
22°C
through an interlock function with air conditioners and
other functions.
Turn the unit OFF if a user didn’t. Reset setpoint regularly.
Change to 20°C
Stop Start
Air-conditioning control for large spaces Building equipment control Working hours Turn ON again by remote controller, 24ºC
(Scheduled) forgot to turn OFF, and left. Saved power consumption
Air handling units can also be controlled. Large Various types of equipment other than air conditioners, by control system
spaces, such as entrance halls and shopping malls, including ventilators, fans, and pumps, can also be 20ºC
can be easily controlled to ensure comfort. controlled. Saved power consumption
by control system
8:00 17:00 18:30 8:00 8:00 10:00 18:00 8:00
85 89
91 90
92 86
Control Systems
m om
total power consumption of
indoor unit. It performs air conditioning billing
h al fr
the intelligent Touch Manager
er
individual indoor units
et
kW ign
calculations quickly and automatically.
th se s
System Tenant C
l
[Operation] MEDIUM
Pu
e
Tenant B
It is easy to output PPD data.
• Switch-on/switch-off operation PPD data is output in CSV format to a PC or USB memory Tenant A Tenant C
• Illuminance (1–100%) control device and can be freely processed and managed.
• Various illuminance patterns can be registered DCM009A51
Total power consumption
• Registered pattern can be selected from (BACnet® Client option) LAN *PPD (Power Proportional Distribution) is Daikin’s proprietary calculation method. kWh meter
intelligent Touch Manager
User’s PC
[Overview of control] [ Main functions ]
• Up to 5 DALI modules can be connected to a • 64 DALI addresses can be freely assigned to up • Up to 16 scenes can be set to a single DALI • Register tenants
single BACnet® controller. to 16 groups using a single DALI module. module.
• Set the electricity unit price for 5 time zones
• Up to 64 DALI LED drivers (64 addresses) can (Each group corresponds to a management point • Up to 12 sensors (occupancy, illuminance) can be • Calculate power consumption and electricity charge for each tenant
be connected to a single DALI module. of the intelligent Touch Manager.) connected to a single DALI module. • Show aggregation results in the specified period for each tenant
• DALI BAS simplifies wiring and setting work by • Output the results (Printout and CSV file)
daisy chain wiring and automatic address setting.
87 91
93 92
94 88
Control Systems
RS485 Modbus®Protocol
Protocol Internet
Internet
Wire length is up to 500m
500 m Television
• Set point range limitation and setback DTA116A51
VRV Outdoor unit • SVMPC1 allows
function operation
achieve energy VRV and
of saving DTA116A51 VRV
VRV Outdoor unit
Simple installation system from anywhere(inside
comfortable and
air-conditioning. Outdoor unit
Compatible with
The VRV outdoor unit and home automation Compatible with Electric curtains outside of air-conditioning
• Daily a premise) through the
operation is
Up to 2 units can be DTA116A51* an existing unit.
connected One Adaptor
adaptor system can be connected simply by using internet.
automatically done by schedule function It is easy to check You can control
requires for a house this dedicated adaptor. • Set point range limitation
with annual calendar.and setback if units have
The system not
can be VRV system from
Lighting function achieve energy saving and beenfrom
operated switched off, You can controlthrough
anywhere
*A separate power supply for Home Automation Interface
Interfere Adaptor
Adaptor is
is necessary.
necessary. equipment
outsideetc.a building system from
VRV WiFi
It may not be installed inside some outdoor unit models. comfortable air-conditioning.
e-mail to support quick maintenance.
via the Internet. anywhere through
• Daily air-conditioning operation is WiFi
Functions
automatically done by schedule function It is easy to check
if units have not
Functions with annual calendar.
Category Function Detail been switched off,
Monitor Control • Quick
Main notification
screen of malfunction
Status monitoring by On/Off, Setpoint, Operation mode,etc.Fan step, Flap, Error, Error code, Room Temperature
e-mail to supportManual
quick maintenance.
operation On/Off, Setpoint, Operation mode, Fan step, Flap, Scene Control
On/Off On/Off status of indoor units On/Off On/Off control of indoor units
Cooling, Heating, Fan, Dry, Auto Cooling, Heating, Fan, Dry, Auto Automatic Setpoint range limitation* Cool setpoint min/max, Heat setpoint min/max
Operation mode Operation mode control Off timer* Off timer on/off, Off timer duration (5min – 12h, every 5min)
(depend on indoor unit capability) (depend on indoor unit capability)
Setpoint Setpoint of indoor units Setpoint Cooling/Heating setpoint Setback operation* Setback setpoint range (Cool: 24-35°C, Heat: 10-20°C)
Schedule* Action registration: Time, On/Off, Setpoint, Operation mode, Fan step, Flap, Off timer on/off, Setback setpoint
Room temperature Suction temperature of indoor units Fan direction Swing, Stop, Flap direction (depend on indoor unit capability) Functions
Fan direction Swing, Flap direction (depend on indoor unit capability) Fan volume L, M, H (depend on indoor unit capability) Calendar setting: set by date or day of the week *
: only admin user can set
Category Function
Interlock DetailInterlock operation depend on equipment status
Fan volume L, M, H (depend on indoor unit capability) Filter sign reset Reset filter sign of indoor units
Access security
System User login
setting User name, password
Language, Password setting, User administration*, Point setting*
Forced off status Forced off status of indoor units
Retrieve system information Device
userregistration Registered device (Tablet, Smartphone) can access through the internet
Error Malfunction, Warning with Error code
Connected indoor units D -NET address of connected indoor units can be retrieved. *: Only admin
Main screen
can set.
Status monitoring On/Off, Setpoint, Operation mode, Fan step, Flap, Error, Error code, Room Temperature
Filter sign Filter sign of indoor units
Indoor unit capabilities such as operation mode, Manual operation On/Off, Setpoint, Operation mode, Fan step, Flap
Communication status Communication normal/error of indoor units Indoor unit capabilities
fan control, setpoint HV can be retrieved. Category Setpoint range limitation* Cool setpoint
Automatic Detail min/max, Heat setpoint min/max
ConnectableOff timer*
control Number of indoor units Off timer
Maxon/off,
16 (perOff timer duration (5min – 12h, every 5min)
DTA116A51)
units Setback operation*
Number of DTA116A51 Setback
Maxsetpoint rangeof
2 (maximum (Cool: 24-35°C,
32 indoor unitsHeat: 10-20°C)
can be connected)
VRV Smart PhoneControl
Smartphone ControlSystem
System ConnectableSchedule* ActionMax
Number of Tablet/Smartphone registration:
20 Time, On/Off, Setpoint, Operation mode, Fan step, Flap, Off timer on/off, Setback setpoint
device Device type Calendar
iPad,setting:
iPhone,set by date
Android or day
tablet, of the week
Android Phone, Windows Tablet, Windows Phone, Windows PC, Mac
VRV Smart
Smartphone
PhoneControl
ControlSystem
Systemcan
canbe
berealized
realizedby
bySVMPR1
SVMPR1which
whichisisaanew
newproduct
producttotoutilize
utilizeDTA116A51.
DTA116A51. System setting LanguageWeb browser English, Spanish,
Firefox, Portuguese,
Chrome, Safari Thai, Vietnam, Simplified Chinese, Traditional Chinese
Password setting
VRV Indoor unit
Just add Multi Site Management System by using SVMPC1: MSMPN1
User administration*
Point setting*
Add/Modify/Delete user, Set User name, Password, Accessible points
Set point name, Select icon
SVMPR1 The MSMPN1 enables monitoring and operation of all Function
SVMPR1 DTA116A51 Specifications
VRV system connected via SVMPC1 on each site. Monitoring: All site information show on a MSM screen.
Category Specification Detail Connection status, A/C operation status,
Head Site Site Error status, Energy consumption etc.
LAN cable Connectable
Quarters
MSMPN1
Number of indoor units Max 32 (with additional DTA116A51)
Operation: All SVMPC1 function can use on MSM
You can control units Number of DTA116A51 Max 2
screen.
VRV from Connectable Number of Tablet/Smartphone Max 20
Internet VRV Indoor unit
anywhere in your device Device type iPad, iPhone, Android tablet, Android Phone, Windows Tablet, Windows Phone, Windows PC, Mac
Control
Systems
VRV Outdoor unit SVMPC1
house through WiFi Web browser Firefox, Chrome, Safari
WiFi router
Smart
Smartphone
phone Monitor Control
WiFi DTA116A51
Modbus is a registered trademark of Schneider Electric S.A.
Modbus ®
router
VRV
Outdoor unit
WiFi router
19993
89 95 94
96 90
Option List
Even in
Even in dusty
dusty environments
environments where
where the
the air
air conditioning
conditioning Using this
Using this kit,
kit, a
a duct
duct can
can be
be connected
connected to
to take
take in
in outdo
outdo
X SERIES Options ofACeiling
Options
SERIESisMounted
constantly Cassette
of Ceiling
operating, ( Round
Mounted
the ultra Cassette
long-lifeFlow with
filter only( Round
Sensing
Flow
air. &
air. with
Round
There
There Sensing
are
are twoFlow
two )&Type
chamber
chamber Round
types
types that Flow
that have
have ) Type
intake
intake in
in two
two
Type has to
has to be
be cleaned
cleaned once a
Typeonce a year.
year. places: with
places: with T-duct
T-duct joint
joint and
and without
without T-duct
T-duct joint.
joint.
RXUQ12A
RXUQ12A RXUQ12AM
RXUQ12AM RXUQ18AM1
RXUQ18AM1
RXUQ6A
RXUQ6A RXUQ14A
RXUQ14A RXUQ14AM
RXUQ14AM RXUQ20AM1
RXUQ20AM1 Options requiredOptions
for specific
required
operating
for
Filterspecific
RXQ6A(W)
RXQ6A
Filter environments
chamber
chamber
RXQ8A(W)
RXQ8A
operating environments
RXQ12A(W)
RXQ12A
RXQ14A(W)
RXQ14A
RXQ18A(W)
RXQ18A
RXQ20A(W)
RXQ20A
RXQ18AM(W)
RXQ18AM
Outside
Outside
RXQ20AM(W)
RXQ20AM
No. RXUQ8A
RXUQ8A RXUQ16A
RXUQ16A RXUQ16AM
RXUQ16AM RXUQ22AM
RXUQ22AM No. (Can be used with high-efficiency filter)
RXQ10A(W)
RXQ10A RXQ16A(W)
RXQ16A RXQ22AM(W)
RXQ22AM
Item
RXUQ10A
RXUQ10A RXUQ18A
RXUQ18A
RXUQ20A
RXUQ20A
RXUQ18AM
RXUQ18AM
RXUQ20AM
RXUQ20AM
RXUQ22AM-SG
Ultra long-life
Item Ultra
filterlong-life
unit filter unit Fresh air intake kit air
Fresh intake
Note 1,
Note 1.22 kit Note 1,
Note 1.22
KHRP26M22H, KHRP26M33H KHRP26M22H, KHRP26M33H, KHRP26M72H
KHRP26M22H, KHRP26M33H KHRP26M22H, KHRP26M33H, KHRP26M72H Even
Even in dusty
1 in dusty environments
Even
REFNET
environments
Distributive Even inwhere
header
in dustythe
where
dusty environments
the air
air conditioning
environments
conditioning where
where
(Max. 4 branch) the
the air Using this
Using
air conditioning
(Max. 8 branch) conditioningthis(Max.
kit, 4a
kit, abranch)
duct (Max.
duct can
Using
can
Using be
8be this
connected
this
branch) kit, a
connected
kit,
(Max. a8 branch)
duct
to take
duct
to take
can be
can be
in outdoor
in outdoor
connected to
connected to take
take in
in outdo
outdo
Distributive REFNET header piping
1
piping
(Max. 4 branch) (Max. 8 branch) (Max. 4 branch) (Max. 8 branch) (Max. 8 branch)
is constantly operating, is the
REFNETconstantly
jointultra long-life
operating, Ultra
filter the
only
KHRP26A22T,
long-life
ultra filter
long-life
KHRP26A33T air.only
air.
filter There
There are
are two
two chamber
KHRP26A22T, air. There
chamber
air. There
types
types
KHRP26A33T, are
arethat
two
that
two have
chamber
have
KHRP26A72T intake
intaketypes
chamber in
in two
twothat
types that have
have intake
intake in
in two
two
REFNET joint KHRP26A22T, KHRP26A33T KHRP26A22T, KHRP26A33T, KHRP26A72T has 2to
has to be
beOutdoor
cleaned
cleaned once
once
unit multi has
a year.
has
a
Dustyyear.
to
to be
be
area:
connection cleaned
cleaned
annual
piping once
kit filter once a year.
changea year. places:
places: with T-duct
— with T-duct joint
places:
joint
Theand
places:
The without
with T-duct
andunits T-duct
without
with
units T-duct
can bejoint
T-duct
can be joint.
joint and
and without
joint.
installed
BHFP22P100 in T-duct
without
installed in T-duct
the joint.
joint.
the following
following
—
different ways
2 Outdoor unit multi connection piping kit BHFP22P100 *For dust
*For dust concentration
Filter
Filter
1 year
1
concentration of
chamber
chamber
year (Approx.
(Approx. 5,000
of 0.3
5,000 hr)
0.3 mg/m
hr) 15
mg/m33 (Requires separately sold Air purifier.)
15 hr/day
hr/day x
Filter
Filter
x 28
chamber
chamber
28 day/month
day/month xx 12
12 month/year
month/year different
Outside
Outside ways Outside
Outside
Type
(Can be used with high-efficiency
(Can
filter)
be used with high-efficiency
RXQ24AM(W)
RXQ24AM filter)
RXQ34AM(W)
RXQ34AM RXQ42AM(W)
RXQ42AM RXQ52AM(W)
RXQ52AM
Type RXUQ24AM
RXUQ24AM RXUQ32AM
RXUQ34AM RXUQ30AM-SG
RXUQ42AM RXUQ42AM RXUQ52AM
RXUQ52AM Ordinary store or office: filter change every 4 years
RXQ26AM(W)
RXQ26AM RXQ36AM(W)
RXQ36AM Chamber
Chamber
RXQ44AM(W) type (without
RXQ44AM type (without T-duct joint)
T-duct
RXQ54AM(W)
RXQ54AM joint) Note
Note 3,
3.4.5
4, 5
RXUQ24AM-SG
RXUQ26AM RXUQ34AM
RXUQ36AM RXUQ32AM-SG
RXUQ44AM RXUQ44AM RXUQ54AM
RXUQ54AM *For dust
*For dust concentration
concentration of
of 0.15
0.15 mg/m
mg/m33
No. RXQ28AM(W)
RXQ28AM RXQ38AM(W)
RXQ38AM RXQ46AM(W)
RXQ46AM RXQ56AM(W)
RXQ56AM
No.
4 years
4 years (Approx.
(Approx. 10,000
10,000 hr)
hr) 8 8 hr/day
hr/day x
x 25
25 day/month
day/month x
x 12
12 month/years
month/years KDDP55B160
KDDP55B160
RXUQ26AM
RXUQ28AM RXUQ36AM
RXUQ38AM RXUQ34AM-SG
RXUQ46AM RXUQ46AM RXUQ56AM
RXUQ56AM x4
x yearsRXQ30AM(W)
4 years RXQ30AM RXQ40AM(W)
RXQ40AM RXQ48AM(W)
RXQ48AM RXQ58AM(W)
RXQ58AM
RXUQ28AM
RXUQ30AM RXUQ38AM
RXUQ40AM RXUQ36AM-SG
RXUQ48AM RXUQ48AM RXUQ58AM
RXUQ58AM Item Ultra long-life filter Ultra long-life filter
RXQ32AM(W)
RXQ32AM RXQ50AM(W)
RXQ50AM RXQ60AM(W)
RXQ60AM Flexible duct
Flexible duct
Item RXUQ30AM
RXUQ32AM RXUQ40AM RXUQ38AM-SG
RXUQ50AM RXUQ50AM RXUQ60AM
RXUQ60AM (obtained locally)
(obtained locally)
Item RXUQ40AM-SG
KHRP26M22H, KHRP26M33H, KHRP26M72H, KHRP26M73H
Dusty area: annual
1
filter change
Distributive Dusty
REFNET High-efficiency filter unit
area: annual filter change
header The (Max.
(Max. 4 branch) units can(Max.
8 branch) be8 The
The
installed
branch) units
KHRP26M22H, KHRP26M33H, KHRP26M72H, KHRP26M73H
The units can be installed
units in
can
in
canthebe
the
(Max. 8 branch) befollowing
following
installed in
installed in the
the following
following
T-duct joint
T-duct joint
Distributive REFNET header *For
*For dust piping
dust concentration
concentration of
of 0.3
0.3 mg/m
mg/m*For
*For
(Requires
dust concentration
dust concentration
separately sold
of Air
of 0.3purifier.)
0.3
different
different
mg/m (Requires separately sold Air purifier.)
mg/m
ways
ways different ways
different ways (obtained locally)
(obtained locally)
3
3 3
3
(Max. 4 branch) (Max. 8 branch) (Max. 8 branch) (Max. 8 branch)
1
piping
Distributive REFNET header
KHRP26M22H, KHRP26M33H, KHRP26M72H, KHRP26M73H 1 year
1 year (Approx.
(Approx. 5,000
5,000 hr)
hr) 15
15 hr/day
hr/day
REFNET1x
1 Available in
Available
xyear
year
28joint
28 in two
two types:
day/month
day/month
(Approx. types: 65%
(Approx. 5,000
5,000
x 12
x 12hr)65% and
hr) and 90%
90% colorimetry.
month/year
15 hr/daycolorimetry.
hr/day x
month/year
15 x 28
28 day/month
day/month x
x 12
12 month/year
month/year
KHRP26A22T, KHRP26A33T, KHRP26A72T, Suction
KHRP26A73T
Suction
1 REFNET joint (Max. 4 branch) (Max.
KHRP26A22T, 8 branch) (Max.
KHRP26A33T, 8 branch)KHRP26A73T
KHRP26A72T, (Max. 8 branch) chamber
chamber Intake duct
Intake duct
2
piping
Pipe size reducer
REFNET joint KHRP26M73TP,
KHRP26A22T, KHRP26A33T, KHRP26M73HP
KHRP26A72T, KHRP26A73T
2
Ordinary Pipeorsize
store reducer
office: filterOrdinary
change store
every or
4 years
office: filter change every 4 years
Filter chamber
Filter chamber Chamber
Chamber type (without
type Chamber
KHRP26M73TP, KHRP26M73HP
(withoutChamber
T-duct type
type
T-duct joint)
joint) (without
Note
Note 3.4.5
(without
3, 4, 5 T-duct joint)
T-duct joint) Note 3.4.5
Note 3, (obtained
4, (obtained
5 locally)
locally)
(duct length:
(duct length: 4
4mm ma
ma
*For dust
*For dust concentration
Outdoorof
3 concentration of 0.15
unit mg/m
multi
0.15 mg/m *For dust concentration
connection
*For
3
3
dust concentration of 0.15
piping kit of 0.15 mg/m
mg/m33 BHFP22P100 BHFP22P151
Connection
Connection
3
2 Outdoor
Pipe sizeunit multi connection piping kit
reducer BHFP22P100 KHRP26M73TP, KHRP26M73HP BHFP22P151 4 years
4 years (Approx.
(Approx. 10,000
10,000 hr)
hr) 8 4 years
8 hr/day
hr/day
4 years
x 25
x (Approx.
25 (Approx.
day/month
day/month10,000
x 12
10,000
x hr) 8
12 month/years
month/years
hr) 8 hr/day
hr/day(Can25be
x 25
x used with
day/month
day/month ultra
x 12
x 12 long-life filter)
month/years
month/years KDDP55B160
KDDP55B160
chamber
chamber KDDP55B160
KDDP55B160
x4
x 4 years
years x4
x 4 years
years
3 Outdoor unit multi connection piping kit BHFP22P100 BHFP22P151 Flexible
Flexible duct
duct Flexible duct
Flexible duct
REFNET joint (KHRP26A22/33/72/73T) Chamber type
Chamber type (with
(with (obtained
T-duct joint)
T-duct
(obtained joint) Note 3,
locally) Note
locally) 3.4.5
4, 5 (obtained locally)
(obtained locally)
Filter chamber
Filter chamber
chamber
chamber
Suction
Suction
chamber
chamber Intake duct
Intake duct
(obtained locally)
(obtained locally)
Flexibleduct
Flexible
Intake
Intake duct
duct
duct
(obtained locally)
(obtained locally)
(duct length:
(duct length: 4
4mm max.)
max.) (duct length:
(duct length: 44m m ma
ma
Please
Please usewith
use
(Can be used if you
if you think filter)
think
ultra long-life the
the temperature
temperature
(Can be and
and humidity
used with ultra long-lifehumidity
filter)
Connection
Connection
chamber
chamber
Connection
Connection
chamber
chamber
T-duct joint
T-duct joint
inside the
inside the ceiling
ceiling exceeds
exceeds 30°C 30°C and
and RH RH 80%,80%, Suction
Suction
chamber Intake duct
Intake duct
respectively.
respectively. Chamber type
Chamber type (with
chamber
Chamber
Chamber
(with T-duct
T-duct joint) type
type
joint) Note
Note (with
3.4.5
3, (with T-duct joint)
4, 5 T-duct joint) Note 3,
Note 3.4.5
4, 5 (obtained locally)
(obtained locally)
Option PCB High-efficiency filter High-efficiency filter Connection
Connection (duct length:
(duct length: 4
4mm ma
ma
Option PCB Option PCB Top panel
Top panel insulation(1)
insulation(1) KDDP55B160K
chamber
KDDP55B160K
chamber KDDP55B160K
KDDP55B160K
Type RXUQ10A
Type
RXUQ12AM Top
Top panel insulation(2)
Type
panel
RXQ6A(W)
RXQ6A insulation(2) RXQ14A(W)
RXQ14A Direct
Direct installation RXQ26AM(W)
installation
RXQ18AM(W)
RXQ18AM type
type
RXQ26AM Note 6
Note 6
No.
RXUQ6A
RXUQ12A
RXUQ10A
RXUQ14A
RXUQ12A
RXUQ14AM
RXUQ12AM
RXUQ16AM
RXUQ14AM
RXUQ18AM Insulation
No.
kitInsulation
for high humidity
kit for high humidity RXQ8A(W)
Top
TopRXQ8A
panel insulation(3)
panel insulation(3) RXQ16A(W)
RXQ16A RXQ20AM(W)
RXQ20AM
Flexible
Flexible duct
RXQ28AM(W)
RXQ28AM
duct
KDDP55X160A
KDDP55X160A
Flexible duct
Flexible duct
— insulation(2) —
3
2 Home Automation
External Interface Adaptor
control adaptor DTA116A51
DTA104A61 4 Option plate for control
Top
Top
Use
adaptor
panel insulation(2)
panel
when insulation(2) Top
only minimal Top panel
isinsulation(2)
panel
Use when only minimal space is available between
space available Direct installation
Direct
between installation BKS26A *1
type
Direct
type (with
Direct installation
insulation
(withinstallation
Note
Note insulation
6
6 type
material) BKS26A *1
material)type Note 6
Note 6
Intake duct
Intake duct
4
3 Option plate for control
Home Automation adaptor
Interface Adaptor — BKS26A *1 DTA116A51 — BKS26A *1 Top panel
panel insulation(3) Top panel insulation(3)
insulation(3)
drop
Top
drop ceilings
ceilings and
and ceiling
insulation(3) slabs.
ceilingTop panel
slabs. KDDP55X160A
KDDP55X160A KDDP55X160A
KDDP55X160A
(obtained locally)
(obtained locally)
4 Option plate for control adaptor — BKS26A *1 — BKS26A *1 Type
Insulation for
Insulation for decoration
decoration panel
panel
Insulation
Insulation
RXQ32AM(W)
RXQ32AM for decoration
for decoration panel
panel
RXQ40AM(W)
RXQ40AM RXQ48AM(W)
RXQ48AM RXQ56AM(W)
RXQ56AM
Type RXUQ22AM RXUQ32AM RXUQ42AM RXUQ52AM Side panel
Side panel insulation
insulation Side
Side panel
panelNote:
Note: Some ceiling
Some
insulation
insulation ceiling constructions
constructions may
may
RXQ34AM(W)
RXQ34AM hinder
hinder RXQ42AM(W)
RXQ42AM
installation.
installation. Contact your
Contact your RXQ50AM(W)
RXQ50AM RXQ58AM(W)
RXQ58AM
Type RXUQ24AM RXUQ34AM RXUQ44AM RXUQ54AM No. Suspension bracket
Suspension bracket insulation
insulation
Suspension
Suspension bracket
bracket insulation
insulation
RXUQ22AM RXUQ32AM RXUQ42AM RXUQ52AM RXQ36AM(W)
RXQ36AM Daikin DealerRXQ44AM(W)
Daikin Dealer RXQ44AM
before
before installing
installing Note:
RXQ52AM(W)
RXQ52AM
Note: 1. Use
1. Use of of options
options will RXQ60AM(W)
RXQ60AM
will increase operating
increase operating sound.
sound.
No. RXUQ26AM
RXUQ24AM RXUQ36AM
RXUQ34AM RXUQ46AM
RXUQ44AM RXUQ56AM
RXUQ54AM RXQ38AM(W)
RXQ38AM your unit. RXQ46AM(W)
your unit. RXQ46AM RXQ54AM(W)
RXQ54AM2. Connecting ducts, fan, insect nets, fire dampers, air filters, and
No.
Item
RXUQ28AM
RXUQ26AM
RXUQ30AM
RXUQ38AM
RXUQ36AM
RXUQ40AM
RXUQ48AM
RXUQ46AM
RXUQ50AM
RXUQ58AM
RXUQ56AM
RXUQ60AM
Panel spacerPanel spacer
1
Item
DIII-NET expander adaptor Panel spacer
Panel spacer
40mm
40mm
Option
List
91 95
20197 93
207 93
207 96
98202
92
Ceiling Mounted Cassette (Compact Multi Flow) Type
Option List
No. Item Type FXZQ20M FXZQ25M FXZQ32M FXZQ40M FXZQ50M
No.
Ceiling
Note:
No.
Mounted
1 Filter chamber Cassette
is required if Type
installing
Type high efficiency(Double
FXCQ20M filter. Type Flow) Type
Type FXCQ20M
FXUQ71A FXUQ71A FXUQ100A FXUQ100A
Brown KTBJ25K36T KTBJ25K56T KTBJ25K80T KTBJ25K160T –
–
No. Item No. Item FXCQ25M FXCQ40M FXCQ25M
FXCQ50M FXCQ40M
FXCQ63M FXCQ50M
FXCQ80M FXCQ63M
FXCQ125M FXCQ80M FXCQ125M
7 Air discharge adaptor KDAJ25K36A KDAJ25K56A KDAJ25K71A KDAJ25K140A
1 Sealing material of air discharge
1
No. Sealing
outlet material of air discharge
Item outlet
FXCQ32M Model FXCQ32M
FXCQ20A KDBHP49B140 KDBHP49B140
FXCQ25A FXCQ32A FXCQ40A FXCQ50A FXCQ63A FXCQ80A FXCQ125A
2
Item
Decoration panel for air 2
Item
Decoration panel for air discharge
discharge KDBTP49B140 KDBTP49B140
1 Decoration panel 1
1 Decoration panel
Decoration panel BYBC32G-W1 BYBC50G-W1
BYBC32G-W1 BYBCQ40CF
BYBC63G-W1
BYBC50G-W1 BYBCQ63CF
BYBC125G-W1
BYBC63G-W1 BYBCQ125CF
BYBC125G-W1
3 3 KAF5511D160 KAF5511D160
65 % KAF532C50 KAF532C80 KAF532C160
2 High efficiency filter 65%
High efficiency 1
filter *1 HighKAFJ532G36
efficiency filter 65% 1 KAFJ532G56 KAFJ532G36 KAFJ532G80
KAFJ532G56 KAFJ532G160
KAFJ532G80 KAFJ532G160
2 Filter related 2
High efficiency
3 Filter Filter
Filter
filter 90% 1
related
chamber for bottom
chamber bottom suctionFilterKDDFJ53G36 suction
90 %
HighKAFJ533G36
efficiency filter 90% 1 KAFJ533G56
chamber bottom suction
KAFJ533G36
KDDFJ53G36
KDDFJ53G56
KAF533C50
KAFJ533G56
KAFJ533G80
KDDFP53B50
KDDFJ53G56
KDDFJ53G80
KAF533C80
KAFJ533G80
KAFJ533G160
KDDFP53B80
KDDFJ53G80
KDDFJ53G160
KAF533C160
KAFJ533G160
KDDFP53B160
KDDFJ53G160
Ceiling Suspended Type
4 Long lifeLong life replacement filter KAF531C50 KAF531C80 KAF531C160
replacement filter LongKAFJ531G36
life replacement filter KAFJ531G36
KAFJ531G56 KAFJ531G56
KAFJ531G80 KAFJ531G80
KAFJ531G160 KAFJ531G160 No. Item Type FXHQ32MA FXHQ63MA FXHQ100MA FXHQ125A FXHQ140A
Ceiling Mounted
Ceiling
Cassette
Mounted
(Double
Cassette
Flow) Type
Note:
Note: 1 Filter chamber is requiredNote: (Double Flow) Type
*1. If high
if installing installing
1 Filter chamber high
efficiency efficiency
is required
filter. filter,high
if installing filterefficiency
chamber is required.
filter.
1 Drain pump kit KDU50N60VE KDU50N125VE KDU50R160
2 Replacement long-life filter KAFJ501D56 KAFJ501D80 KAFJ501D112 KAF501B160
No. Item No. Item Model Model
FXCQ20A FXCQ25A FXCQ32A
FXCQ20A
FXCQ40A
FXCQ25A
FXCQ50A
FXCQ32A
FXCQ63A
FXCQ40A
FXCQ80A
FXCQ50A
FXCQ125A
FXCQ63A FXCQ80A FXCQ125A
1 Decoration panel Slim
1 Ceiling
Ceiling Mounted
Decoration Mounted
panel Duct(Single
Cassette Type (Standard
BYBCQ40CF Series)
Flow) TypeBYBCQ40CF
BYBCQ63CF BYBCQ63CF
BYBCQ125CF BYBCQ125CF
3
4
L-type piping kit (for upward direction)
Fresh air intake kit
KHFP5M63
-
KHFP5M160 KHFP5N160
KDDQ50A140
65 % 65 % KAF532C50 KAF532C50
KAF532C80 KAF532C80
KAF532C160 KAF532C160
2 2
High efficiency filter *1 No. High efficiency filter *1 Type
No. Item
90 % 90 % KAF533C50 FXDQ20PD
FXEQ20AFXDQ25PD
KAF533C50 FXDQ32PD
FXEQ32A
KAF533C80 FXDQ40ND
KAF533C80FXDQ50ND
KAF533C160 FXDQ63ND
FXEQ50AKAF533C160
3 Filter chamber for bottom3 Item
1 suction
Filter chamber
Insulation for high
kit for bottom suction
humidity KDDFP53B50 FXEQ25A FXEQ40A
KDT25N32
KDDFP53B50
KDDFP53B80 FXEQ63AKDDFP53B160
KDT25N50
KDDFP53B80
KDDFP53B160 KDT25N63
4 Long life replacement filter
41 Decoration panel
Long life replacement filter KAF531C50 BYEP40AW1
KAF531C50
KAF531C80 KAF531C80 BYEP63AW1KAF531C160
KAF531C160
Note: *1. If installing high efficiency
Note: *1.
filter,
If installing
filter chamber
high efficiency
is required.
filter, filter chamber is required. Wall Mounted Type
Middle Static Pressure Ceiling Mounted Duct Type No. Type FXAQ20A FXAQ25A FXAQ32A FXAQ40A FXAQ50A FXAQ63A
Item
Slim Ceiling Mounted
Slim
Ceiling Mounted
Slim Ceiling
Ceiling Duct
Cassette
Ceiling Type
Mounted
Mounted
(Single(Standard
Duct
Cassette
Flow)
Mounted Type
Series)
Type
Duct(Single
Type (Standard
Flow)
(3D
Type Series)
Type
Airflow
FXSQ20PA with Sensing)
FXSQ50PA
FXSQ100PA 1 Drain pump kit K-KDU572EVE
No. FXSQ25PA FXSQ40PA FXSQ63PA FXSQ140PA
Type FXDQ20PD Type FXSQ125PA
No.
No. Item No.
No. Item
Item
Item FXEQ20AFXDQ25PD FXDQ20PD
FXDQ32PD
FXEQ20AFXDQ25PD
FXSQ32PA
TypeFXEQ32A
FXDSQ20A FXDQ40ND FXDQ32PD
FXEQ32A
FXDSQ25A FXDQ50ND
FXEQ50A FXDQ40ND
FXSQ80PA
FXDSQ32A FXDQ63ND
FXDSQ40A FXDQ50ND
FXDSQ50A FXDQ63ND
FXEQ50A FXDSQ63A
1 Item 1 Item
Insulation kit for high humidity 65%
Insulation kit for high humidity FXEQ25A FXEQ40A
KDT25N32 FXEQ25A FXEQ40A
KAFP632B36 KDT25N32
KAFP632B56 FXEQ63A FXEQ63A
KAFP632B160
KDT25N50 KAFP632B80KDT25N63
KDT25N50 KAF632B160B
KDT25N63
1 Flexible duct filter *1
High efficiency BFD37B40 BFD37B50 BFD37B63
1 Decoration panel 1 Decoration panel 90% BYEP40AW1 KAFP633B36 BYEP40AW1
KAFP633B56 BYEP63AW1
KAFP633B80 BYEP63AW1 KAF633B160B
KAFP633B160
2 Filter chamber (for rear suction) *1 KDDFP63B36 KDDFP63B56 KDDFP63B80 KDDFP63B160 KDDF63B160B Floor Standing Type
Middle Static Pressure
Middle Static
Ceiling
Pressure
MountedCeiling
Duct Type
3
Mounted Duct Type
Long-life filter *1
White
KAFP631B36 KAFP631B56 KAFP631B80 KAFP631B160 KAF631B160B
No. Type FXLQ20MA FXLQ25MA FXLQ32MA FXLQ40MA FXLQ50MA FXLQ63MA
KTBJ25K36W KTBJ25K56W KTBJ25K80W KTBJ25K160W Item
Slim Ceiling
Slim Ceiling Mounted Mounted
Duct Type Duct Type
(3D Airflow
4 with(Standard
(3D AirflowSeries)
Sensing) with Sensing)
Service panel Type Fresh FXSQ20PAwhite Type FXSQ20PA FXSQ50PA
KTBJ25K36F KTBJ25K56F
FXSQ100PA
FXSQ50PA
KTBJ25K80F FXSQ100PA KTBJ25K160F 1 Long life replacement filter KAF361L28 KAF361L45 KAF361L71
No. No. FXSQ25PA
Brown FXSQ40PA FXSQ25PA FXSQ63PA
KTBJ25K36T FXSQ40PA
KTBJ25K56T FXSQ63PAFXSQ140PA
KTBJ25K80T FXSQ140PA
KTBJ25K160T
Item Item Type FXSQ125PA FXSQ125PA
No. Item No.
No.
5 Air discharge adaptorType
Item
Item FXSQ32PA
FXDSQ20A FXDSQ25A FXSQ32PA
Type FXDQ20PDFXDSQ20A FXSQ80PA
FXDSQ32A
KDAP25A36A FXDQ25PD
FXDSQ25A
FXDSQ40A
KDAP25A56A FXSQ80PA
FXDQ32PD
FXDSQ32A
FXDSQ50A FXDQ40ND
FXDSQ40A
KDAP25A71AFXDSQ63A FXDQ50ND FXDQ63ND
FXDSQ50A KDAP25A160A
KDAP25A140A FXDSQ63A *2
Flexible duct filter *1 61 65%
Insulation
Shield
Flexible plate
ductkitfor
for high
side humidity
plate KAFP632B36
65% KAFP632B56
BFD37B40
KAFP632B36
KAFP632B80
KDT25N32 KAFP632B160
KAFP632B56
KDBD63A160
BFD37B40 BFD37B50
KAF632B160B
KAFP632B80 KAFP632B160
KDT25N50
BFD37B63 BFD37B50
KAF632B160B
KDT25N63
—
BFD37B63
1 High efficiency 1 High efficiency filter *1
90% KAFP633B36
90% KAFP633B56 KAFP633B36
KAFP633B80KAFP633B56
KAFP633B160
KAFP633B80 KAFP633B160
KAF633B160B KAF633B160B
Note: *1. If installing high efficiency filter and long-life filter to the unit, filter chamber is required.
2 Filter chamber (for rear suction)
2 Filter
*1 chamber (for rear suction) KDDFP63B36
*2. This option is a set of KDAP25A140A
*1
and KDBHP37A160.KDDFP63B56 KDDFP63B36
KDDFP63B80KDDFP63B56 KDDFP63B80
KDDFP63B160 KDDFP63B160
KDDF63B160B KDDF63B160B Concealed Floor Standing Type
3 Long-life filter *1 3 Long-life filter *1 KAFP631B36 KAFP631B56 KAFP631B80
KAFP631B36 KAFP631B160
KAFP631B56 KAFP631B80 KAFP631B160
KAF631B160B KAF631B160B
No. Type FXNQ20MA FXNQ25MA FXNQ32MA FXNQ40MA FXNQ50MA FXNQ63MA
Middle Static Pressure Ceiling Mounted Duct Type
White White
KTBJ25K36W KTBJ25K56W KTBJ25K36WKTBJ25K80WKTBJ25K56W KTBJ25K160W
KTBJ25K80W KTBJ25K160W Item
Slim Ceiling Mounted
4 Slim Ceiling
Duct Type
Mounted
Service panel
Ceiling Mounted (Standard
Duct Duct
Type Type
Series)
4 (Standard Series)
Service
Fresh panel
white Fresh white
KTBJ25K36F KTBJ25K56F KTBJ25K80F
KTBJ25K36F KTBJ25K56F KTBJ25K160F
KTBJ25K80F KTBJ25K160F 1 Long life replacement filter KAF361L28 KAF361L45 KAF361L71
Brown Brown
KTBJ25K36T Type
KTBJ25K56T FXSQ20PA KTBJ25K80T
KTBJ25K36T KTBJ25K56T FXSQ50PA
KTBJ25K160T
KTBJ25K80T KTBJ25K160T
No. No. Type FXDQ20PD Type
FXDQ25PD FXDQ20PD
FXDQ32PD FXDQ25PD
FXDQ40ND FXDQ32PD
FXDQ50ND FXDQ40ND FXSQ100PA
FXDQ63ND FXDQ50ND FXDQ63ND
5 Item
Air discharge adaptor 5 Item
Air discharge adaptor KDAP25A36A Type
KDAP25A56A FXSQ25PA
FXMQ20PA KDAP25A71A
KDAP25A36A FXSQ40PA FXSQ63PA
FXMQ50PA
KDAP25A140A
KDAP25A56A FXMQ100PA
KDAP25A160A
KDAP25A71A *2
KDAP25A140A FXSQ140PA
KDAP25A160A *2
Item FXSQ125PA FXMQ200M
1
6 Insulation
Shield platekitfor
for high
side No.
1
humidity
6
plate Insulation
Shield platekitfor for high
side humidity
plate FXSQ32PA
KDT25N32 FXMQ25PA
KDBD63A160 KDT25N32 FXMQ40PA
KDT25N50 FXSQ80PAKDT25N63
FXMQ63PA
KDBD63A160 FXMQ125PA
— KDT25N50 KDT25N63
—
Item 65% KAF632C36 KAF632C56 KAF632C80 KAF632C160 FXMQ250M
KAF632B160B
Note: *1. If installing high efficiency
Note:1 *1.
filter
If installing
and
Highlong-lifehighfilter
efficiency efficiency
to*1the filter
filter unit, and
filterlong-life
chamberfilter
is required. FXMQ32PA
to the unit, filter chamber is required. FXMQ80PA FXMQ140PA
1 *2. This
*2. This option is a set of KDAP25A140A Drain pump
option akitset of KDAP25A140A
andisKDBHP37A160. 90% and KDBHP37A160. KAF633C36 KAF633C56 — KAF633C80 KAF633C160 KAF633B160B
KDU30L250VE
2 Filter chamber (for rear suction) *1 65% KDDFP63B36
KAF372AA36 KDDFP63B56
KAF372AA56 KDDFP63B80
KAF372AA80 KDDFP63B160
KAF372AA160 KDDF63B160B
KAFJ372L280
2 High efficiency filter
Middle Static Pressure
Middle Static
Ceiling
Pressure
MountedCeiling
Duct Type
3
3
Mounted Duct Type
Long-life filter *1
Filter chamber
90% KAF373AA36
KAF631C36
KDDF37AA36
KAF373AA56
KAF631C56
KDDF37AA56
KAF373AA80
KAF631C80
KDDF37AA80
KAF373AA160
KAF631C160
KDDF37AA160
KAFJ373L280
KAF631B160B
KDJ3705L280
Ceiling MountedCeiling
Duct Type
Mounted Duct Type 4
4 Long
Servicelifepanel
replacementType filter
White
FXSQ20PA
Fresh white Type
KTBJ25K36W
KAF371AA36
FXSQ20PA
KTBJ25K36FFXSQ50PA
KTBJ25K56W
KAF371AA56
KTBJ25K56F
KTBJ25K80W
KAF371AA80
FXSQ50PA
KTBJ25K80F
KTBJ25K160W
KAF371AA160 KAFJ371L280
KTBJ25K160F
5 Long life filter chamber kit KAF375AA36 FXSQ100PA
KAF375AA56 KAF375AA80 FXSQ100PA
KAF375AA160
No. No. Type Brown FXSQ25PA
FXMQ20PA FXSQ40PA FXSQ25PA
Type KTBJ25K36T
FXMQ20PA FXSQ63PA
FXMQ50PA FXSQ40PA
FXMQ100PA
KTBJ25K56T FXSQ63PA
FXMQ50PAFXSQ140PA
KTBJ25K80T FXMQ100PA FXSQ140PA
KTBJ25K160T
Item Item FXSQ125PA FXMQ200M FXSQ125PA FXMQ200M
No. No.
5 Air discharge
FXSQ32PA White FXMQ40PA
FXMQ25PA FXSQ32PA
KTBJ25K36W
FXMQ25PA
KDAP25A36AFXSQ80PA
FXMQ63PA
KTBJ25K56W
FXMQ125PA
FXMQ40PA
KDAP25A56A
KTBJ25K80W
FXSQ80PA
FXMQ63PA
KDAP25A71A
KTBJ25K160W
FXMQ125PA
KDAP25A140A KDAP25A160A *2
6 Service panel adaptor FXMQ250M FXMQ250M
—
Item Item
65% KAF632C36 Fresh white
65%
FXMQ32PA KAF632C56 KTBJ25K36F
KAF632C36
FXMQ32PA KAF632C80
FXMQ80PA
KTBJ25K56F
KAF632C160
KAF632C56
FXMQ140PA
KTBJ25K80F KTBJ25K160F
KAF632B160B
KAF632C80
FXMQ80PA KAF632C160
FXMQ140PA KAF632B160B
1 High efficiency filter *1 61 Shield plate for filter
High efficiency side *1plate Brown KTBJ25K36T KDBD63A160
KTBJ25K56T KTBJ25K80T KTBJ25K160T
—
1 Drain pump kit 1 90%
Drain pump kit KAF633C36
90% KAF633C56 KAF633C36
— KAF633C80 KAF633C56
KAF633C160
— KAF633C80 KAF633C160
KAF633B160B
KDU30L250VE KAF633B160B
KDU30L250VE
Note:7*1. If installing high efficiency
Air discharge adaptor filter and long-life filter to the unit, filter chamber
KDAJ25K36A is required.
KDAJ25K56A KDAJ25K71A KDAJ25K140A
2 Filter chamber (for rear suction)
2 Filter
*1 chamber (for65% rear suction)KDDFP63B36
*1
KAF372AA36 KDDFP63B56
65%KAF372AA56 KDDFP63B36KDDFP63B80
KAF372AA36
KAF372AA80KDDFP63B56
KAF372AA56 KDDFP63B80
KDDFP63B160KAF372AA80
KAF372AA160 KDDFP63B160
KDDF63B160B
KAF372AA160
KAFJ372L280 KDDF63B160B
KAFJ372L280
2 High efficiency filter 2*2. ThisHigh option is a setfilter
efficiency of KDAP25A140A and KDBHP37A160.
3 Long-life filter *1 3 Long-life filter *1 90% KAF373AA36
KAF631C36 90%KAF373AA56
KAF631C56 KAF373AA36
KAF631C36KAF373AA80
KAF631C80 KAF373AA56
KAF631C160
KAF631C56 KAF373AA80
KAF373AA160
KAF631C80 KAF373AA160
KAFJ373L280
KAF631C160
KAF631B160B KAFJ373L280
KAF631B160B
3 Filter chamber 3 Filter chamber
White KDDF37AA36
White
KTBJ25K36W KDDF37AA56
KTBJ25K56W KTBJ25K36W KDDF37AA80
KDDF37AA36
KTBJ25K80W KDDF37AA160
KDDF37AA56
KTBJ25K56W KDJ3705L280
KDDF37AA80
KTBJ25K80W
KTBJ25K160W KDDF37AA160 KDJ3705L280
KTBJ25K160W
Option
List
4
4 Long
Servicelifepanel
replacement filter
4
4 Long
Service
Fresh lifepanel
white replacement filter KAF371AA36
Fresh white KAF371AA56 KAF371AA80
KAF371AA36 KAF371AA160
KAF371AA56 KAFJ371L280
KAF371AA80 KAF371AA160 KAFJ371L280
KTBJ25K36F KTBJ25K56F KTBJ25K36FKTBJ25K80FKTBJ25K56F KTBJ25K160F
KTBJ25K80F KTBJ25K160F
5 5
Long life filter chamber kit Long life filter chamber kit KAF375AA36 KAF375AA56 KAF375AA80
KAF375AA36 KAF375AA160
KAF375AA56 KAF375AA80 KAF375AA160
Brown Brown
KTBJ25K36T KTBJ25K56T KTBJ25K36TKTBJ25K80TKTBJ25K56T KTBJ25K160T
KTBJ25K80T KTBJ25K160T
White KTBJ25K36W White KTBJ25K56W KTBJ25K36WKTBJ25K80W KTBJ25K160W
KTBJ25K56W KTBJ25K80W KTBJ25K160W
5 panel adaptor 5
Air discharge
Service Air discharge
Service panel adaptor KDAP25A36A KDAP25A56A KDAP25A36AKDAP25A71A KDAP25A140A
KDAP25A56A KDAP25A160A
KDAP25A71A *2
KDAP25A140A KDAP25A160A *2
6 6 Fresh white KTBJ25K36F Fresh white KTBJ25K56F KTBJ25K80F
KTBJ25K36F KTBJ25K80F — KTBJ25K160F
KTBJ25K160F
KTBJ25K56F —
6 Shield plate for side plate6 Shield plate forBrown side plate KDBD63A160 KDBD63A160 — —
KTBJ25K36T Brown KTBJ25K56T KTBJ25K80T
KTBJ25K36T KTBJ25K160T
KTBJ25K56T KTBJ25K80T KTBJ25K160T
Note:7*1. If installing high efficiency
Air discharge Note:7*1.
adaptor filter
If installing
andAir long-life
highfilter
discharge efficiency
adaptorto the filter
unit, and
filter long-life
chamberfilter
KDAJ25K36A is required.
to the unit, filter
KDAJ25K56A chamber is required.
KDAJ25K71A
KDAJ25K36A KDAJ25K140A
KDAJ25K56A KDAJ25K71A KDAJ25K140A
*2. This option is a set of KDAP25A140A
*2. This option andisKDBHP37A160.
a set of KDAP25A140A and KDBHP37A160.
94
Option
List
Option
List
97
99 94 94 98
100
OptionOption
List List
VRV
Residential
Indoor Indoor
Units Units with connection to BP units ControlControl
Systems Systems New Design New Desig
Slim Ceiling
Floor Mounted
Standing Duct Type
Duct Type Operation Control SystemControl
Operation Optional Accessories
System Optional Accessories Remote sensor Remote se
BRCS01A-1(4) BRCS01A
No. Item
No. Item
Type FDKS25EA
Type FXVQ125N FDKS35EA
FXVQ200N FXVQ250N
FDKS25CA FXVQ400N
FDKS35CA FDKS50C FXVQ500N
FDKS60C For VRV indoorFor
unitVRV
useindoor unit use
11 Insulation kit for high humidity KDT25N32 KAF261M224
KAF261M140 KDT25N50KAF261N450
KAF261M280 KDT25N63
KAF261N560
No. No.
No. Type Type FXFSQ-A
Type FXDQ-PD
FXDQ-PD FXDQ-PD
FXFSQ-A FXFQ-A FXFSQ-A FXUQ-AFXZQ-M
FXZQ-M FXZQ-M FXCQ-AFXUQ-A
FXEQ-A FXDQ-SP
FXFQ-A FXFQ-A
Item Item
Item FXCQ-M FXEQ-A FXCQ-A FXDQ-SP
FXEQ-A
FXDQ-ND FXSQ-PA FXDQ-ND
FXDSQ-A FXMQ-PA
2 – KAFSJ9A400 KAFSJ9A560 FXDQ-ND
1 Navigation remote controller
1 Navigation remote controller BRC1E63 Note 5 BRC7M635F
BRC1E63
BRC1E63BRC1E63
Note 5 5 BRC1E63
NoteBRC1E63 BRC1F61
BRC1E63 Note 5 BRC1E63 BRC1E63BRC1F61 Note 5
BRC1F61 BRC1
Wall
3
Mounted Type KD-9A140 KD-9A200 KD-9A280 KD-9A400 KD-9A560
2 Simplified remote controller
2 Simplified remote controller—Wireless (Fresh
—White) / BRC2E61 BRC2E61 BRC2E61 — BRC2
4 Suction grille KDGF-9A140 KDGF-9A200 KDGF-9A280 KDGF-9A400 KDGF-9A560 1 Remote controller BRC7M635K BRC7E531W BRC7C67 BRC4M63 BRC4C66
FTKS50F BRC7M635F (Fresh White) / BRC7M635F (Black) (FreshBRC7CB59
White) /
Type 3 Wireless remote controller
3 Wireless remote controller BRC7E531W BRC7M66
BRC7E531W BRC4M63
BRC7CB59 BRC7M66 BRC4C66BRC4M66
BRC4M63 BRC4
Discharge and Suction
No. Item Type FXBQ40P FXBQ50P FXBQ63P FXBPQ63P 6-1 Wiring adaptor for electrical
Note 2, 3 appendices
Note 2, 3 (1)NoteKRP2A61
2, 3 Note
Note 3 2, 3 —Note 3 KRP2A62
Note 2, 3 KRP2A61
Note 3 Note 3KRP2A61Note 2, 3 KRP2A62 KRP2A61
7 Installation box for adaptor
7 PCB
Installation box for adaptor PCB — — — —
6-2 Wiring adaptor for KRP4A98 KRP4A97 (2)KRP4A98
electrical appendices KRP4AA51 KRP4A97
KRP1CA93 KRP1D93A
KRP4AA53 KRP4AA93
KRP4AA52 KRP1CA93
KRP4AA51KRP1D93A
KRP4AA51 KRP4AA93 — KRP4AA51
1 Outlet unit – BAF82A63
7 Remote sensor (for indoor temperature) BRCS01A-1 BRCS01A-4 BRCS01A-1
Note 8 Note 8
2 Filter BAFH82A50 BAFH82A63 8 External control adaptor 8 forExternal
outdoor control
unit adaptor DTA104A61
for outdoor unit DTA104A61 DTA104A61 DTA104A62DTA104A61 DTA104A61 DTA104A61
DTA104A62 DTA104A61
DTA104A61
DTA104A62 DTA104A61 DTA104A62
Note 3 Note 2, 3
8 Installation box for adaptor PCB — KRP1BA97 —
3 Ceiling intake type BYB82A50C BYB82A63C BYB82A63CP 9 Adaptor for multi tenant 9 Adaptor for multi tenantDTA114A61 — DTA114A61 — — KRP1CA93
DTA114A61
DTA114A61KRP4AA93 — — DTA114A61 —
Panel 10 External control adaptor 10 for cooling
External/ heating
control adaptor for cooling / heating — — KRP6A1 Note 8 — 10
Note KRP6A1 Note
4 Floor-level intake type BYB82A50W BYB82A63W BYB82A63WP 9 External control adaptor for outdoor unit DTA104A61 — DTA104A62 DTA104A61 DTA104A61 DTA104A61
11 Remote controller with 11key Remote controller with key — — KRCB37-1 DTA104A62 — KRCB37-1
5 KDFJ82A80 10 Adaptor for multi tenant — DTA114A61 —
Note: 1. Installation box is necessary forInstallation
Note: 1. each adaptorbox marked .
is necessary for each adaptor marked .
2. Up to 2 adaptors can be fixed External
112.forUpeach
to control
2installation
adaptors box.
can adaptor
be fixed forforeach
cooling / heating
installation box. — KRP6A1 Note 10 —
123.
3. Only one installation box can beOnly Remote
installed controller
for each box with
indoor
one installation unit.be
can key
installed for each indoor unit. — KRCB37-1 —
4. Up to 2 installation boxes can4.beUp
installed for each indoor
to 2 installation unit.be installed for each indoor unit.
boxes can
Note: 1. Installation box is necessary for each adaptor marked .
5. Some functions can be set only2. via to
5. Up
Some the2functions
wired
adaptorsremote
can controller
canbe
beset only
fixed BRC1E63
forvia or BRC1F61.
the installation
each wired remote They cannot
controller
box. be setorvia
BRC1E63 other remote
BRC1F61. Theycontrollers.
cannot be set via other remote controllers.
Please refer to each indoor unit and
Pleaseremote
refer controller
to each boxpage
indoor for
befunction
canunit and details.
remoteforcontroller page for function details.
2 2 KRP413AB1S KRP413BB1S
No. Type BPMKS967A2 BPMKS967A3 (Normal
(Normal open pulse contact/normal open
open pulse contact/normal open contact)
contact)
Option
List
Item
3 Remote controller loss 3 prevention
Remote chain
controller loss prevention chain KKF917A4 KKF917A4 KKF910A4
KKF917A4 KKF917A4
1 REFNET joint KHRP26A22T
4 Interface adaptor for4DIII-NET Interface
use adaptor for DIII-NET use KRP928BB2S KRP928BB2S
Note: A single BP unit does not require a REFNET joint. 2 BP units require only 1 REFNET joint, and 3 BP units require only 2 REFNET joints.
Note:is1.aAstandard
Note: 1. A wireless remote controller wirelessaccessory.
remote controller is a standard accessory.
2. Time clock and other devices 2. Time be
should clock and other
obtained devices should be obtained locally.
locally.
99
101 210
96 211
97 100
102
Daikin Engineering Supports
System Configuration
No. Item Model No. Function
VRV Design and Sales Proposal Assistance
• Up to 16 groups of indoor units (128 units) can be easily controlled using the
System Configuration
Note 2
1 Residential central remote controller
DCS303A51
large LCD panel. ON/OFF, temperature settings and scheduling can be
controlled individually for indoor units.
Daikin provides engineering supports for VRV systems. It
No.
2 Interface adaptor forItem
residential indoor units Model No.
KRP928BB2S Function consists of design supports that can assist consultants and
• Adaptors required to connect products other than those of the VRV System to
• Up to 16 groupsDIII-NET
of indoorcommunication
units (128 units) can beadopted
easily controlled using the
1
3 Residential
Interface centralfor
adaptor remote controller
SkyAir-series
Note
Note 32 the high-speed system
large LCD panel. ON/OFF, temperature settings and scheduling can be
for the VRV System. architects, as well as sales proposal supports for air conditioning
DCS303A51
DTA112BA51 controlled individually for indoor units.
4 Central control adaptor kit For UAT(Y)-K(A),FD-K DTA107A55
* To use any of the above optional controllers, an appropriate adaptor must be
installed on the product unit to be controlled.
engineers and dealers. We at Daikin provide the software, the
2
5 Interface
Wiring adaptor
adaptor forfor residential
other indoor units
air-conditioner KRP928BB2S
DTA103A51 • Adaptors required to connect products other than those of the VRV System to
Note 3 the
• Up to high-speed
1024 unitsDIII-NET communication
can be centrally system
controlled in 64adopted
differentfor the VRV System.
groups. simulation results, and drawing materials to support the
3
6 Interface expander
DIII-NET adaptor for SkyAir-series
adaptor DTA112BA51 • Wiring restrictions (max. length: 1,000m, total wiring length: 2,000m, max.
DTA109A51
*number
To use any of the above
of branches: 16)optional
apply tocontrollers, an appropriate adaptor must be
each adaptor. business-information modeling (BIM) currently entering the
4 Central control adaptor kit For UAT(Y)-K(A),FD-K DTA107A55 installed control
on the product unit toor
bemultiple
controlled.
• Demand of individual systems.
5
6-1 Wiring
External adaptor
controlfor other air-conditioner
adaptor DTA103A51
DTA104A61
• Low noise option for individual or multiple systems. mainstream in construction industries.
• Up to 1024 units can be centrally controlled in 64 different groups.
6
6-2 DIII-NET
Mountingexpander
plate adaptor DTA109A51 •• When
BKS26A Wiringinstalling DTA109A51,
restrictions DTA104A61
(max. length: 1,000m, into
totaloutdoor units of2,000m,
wiring length: 10 HP (VRV
max.X) /
14
or larger.
HP (VRV
number A) or larger.
of branches: 16) apply to each adaptor.
Mountingbox
6-11. Installation
Note: plate KRP4A92
for adaptor must be obtained locally. • Fixing plate for DTA109A51
Design
2. For residential use only. Cannot be used with other centralised control equipment.
Note: 1. Installation box for adaptor must be obtained locally.
3. No adaptor is required for some indoor units.
2. For residential use only. Cannot be used with other centralised control equipment.
3. No adaptor is required for some indoor units.
1-2
2 Electrical box withBasic
earth terminal intelligent Touch
(4 blocks)
Hardware KJB411A • Air-conditioning
Wall management
embedded switch box. system that can be controlled by
Manager DCM601A51 touch screen.
2 Basic Hardware intelligent Touch
• Air-conditioning management system that can be controlled by
Manager DCM601A51 • Additional
touch 64 groups (10 outdoor units) is possible.
screen.
2-1 Hardware iTM plus adaptor DCM601A52 Max. 7 iTM plus adaptors can be connected to intelligent Touch CFD simulation to optimise
Manager. 64 groups (10 outdoor units) is possible.
Additional
Heat load calculation
•
2-1 Hardware iTM plus adaptor DCM601A52 Max. 7 iTM plus adaptors can be connected to intelligent Touch
Manager.
outdoor unit layouts
iTM power • Power consumption of indoor units are calculated based on
2-2 proportional DCM002A51 operation status of the indoor unit and outdoor unit power
intelligent Touch iTM power • Power consumption
consumption measuredof indoor units
by kWh are calculated based on
metre.
2-2 distribution operation status of the indoor unit and outdoor unit power
Manager proportional DCM002A51
intelligent Touch distribution consumption measured by kWh metre.
Building energy consumption is visualised.
2-3 Option Software iTM energy
DCM008A51
•
Manager navigator Wasted air-conditioning energy can be found out.
2-3 Option Software iTM energy • Building energy consumption is visualised.
2-4 BACnet
navigator client DCM008A51 Wasted® air-conditioning
BACnet equipment can be energy can by
managed beintelligent
found out.Touch Manager.
®
DCM009A51
Design flexibility
•
2-4
2-5 BACnet ®
client
HTTP Interface DCM009A51
DCM007A51 • BACnet® for
Interface equipment can
intelligent be managed
Touch Managerby
byintelligent
HTTP Touch Manager.
2-5
2-6 HTTP Interface DCM007A51
SVMPR2 • Interface for intelligent
VRV Smartphone Touch
Control Manager
System by HTTP
for residence
2-7
2-6 Hardware *1 SVM series SVMPC2
SVMPR2 • VRV Smartphone
Smart phoneRemote
Control Controller
System forfor
residence
building
2-7
2-8 Hardware *1 SVM series SVMPC2
*5 SVMPS1 • VRV Smart
Tenant Phone
Billing Remote
System Controller for building
with PPD
2-8
2-9 VRV Smartphone Control System *5 SVMPS1
SVMPR1 • VRV Smartphone
Tenant Control
Billing System withSystem
PPD for residence with DTA116A51. Heat load calculation Model selection Drawing materials support
2-9 VRV Smart Phone Control System SVMPR1 • VRV
*6 Smart
• VRV Phone
Tablet and Control
Smartphone System for residence
Controller withsize
for small DTA116A51.
building or
2-10 VRV Tablet and Smartphone Controller SVMPC1
2-10 VRV Tablet Controller SVMPC1 • VRV residence with DTA116A51.
Tablet Controller for small size building with DTA116A51
2-11
2-11 Multi
Di unitSite Management System by using SVMPC1 MSMPN1
DEC101A51 MSM
•• 8 pairscan control
based VRV
on aallpair of units
ON/OFFvia SVM
inputsystem on multi site.
and abnormality input.
2-12
2-12 Di
Diounit
unit DEC101A51
DEC102A51 8
4 pairs
pairs based
••
based on on aa pair
pair of
of ON/OFF
ON/OFF input
input and
and abnormality
abnormality input.
input.
2-13 Dio unit DEC102A51 4 pairs based
Interface
•• unit onto aallow
pair of ON/OFF input and
communications abnormality
between input.
VRV and BMS.
3 *2 Interface for use in BACnet® DMS502B51 Operationunit
• Interface andtomonitoring of air-conditioning
allow communications systems
between through
VRV and BMS.
3 *2 Interface for use in BACnet® DMS502B51 BACnet
Operationcommunication.
®
and monitoring of air-conditioning systems through
• BACnet
Expansioncommunication.
®
kit, installed on DMS502B51, to provide 2 more DIII-NET
3-1 Optional DIII board DAM411B51
communication
• Expansion ports. Not
kit, installed on usable independently.
DMS502B51, to provide 2 more DIII-NET
3-1 Communication Optional DIII board DAM411B51
interface communication
• Expansion kit, ports. Not
installed on usable independently.
DMS502B51, to provide 16 more wattmeter
Sales proposals
3-2 Optional Di board DAM412B51
pulse inputkit,
• Expansion points. Noton
installed usable independently.
DMS502B51, to provide 16 more wattmeter
3-2 Optional Di board DAM412B51
pulse input
• Interface points.
unit Notcommunications
to allow usable independently.
between VRV and BMS.
Communication
4 *3 Interface for use in LONWORKS® Operationunit
DMS504B51 • Interface andtomonitoring of air-conditioning
allow communications betweensystems
VRV andthrough
BMS.
interface LonWorks ®
communication.
4 *3 Interface for use in LONWORKS® DMS504B51 Operation and monitoring of air-conditioning systems through
LonWorks
• Use
®
communication.
of the Modbus protocol enables the connection of the For air conditioning engineers and dealers
5 Home Automation Interface Adaptor DTA116A51 *7VRV
• Usesystem
of the with
Modbusa variety
® of home
protocol automation
enables systems of
the connection from
the
5 Home Automation Interface Adaptor DTA116A51 other
VRVmanufacturers.
system with a variety of home automation systems from
Contact/ Unification adaptor for computerised other manufacturers.
• Interface between the central monitoring board and central control
6 analogue signal control DCS302A52 • units.
When installing DTA116A51 into outdoor units of 10 HP (VRV X) /
5-1 Mounting plate BKS26A 14
or larger.
HP (VRV A) or larger.
Note: *1. HTTP interface (DCM007A51) is also required.
Contact/is a registeredUnification
trademark ofadaptor
Americanfor computerised • Interface between the central monitoring board and central control
Heat load calculation Model selection
®
6 *2. BACnet
analogue
Society of Heating, Refrigerating
DCS302A52 and Air-Conditioning Engineers (ASHRAE).
is signal control units.
®
*3. LonWorks a trademark of Echelon Corporation registered in the United States and other countries.
*4. Installation box for adaptor must be obtained locally.
Note: *1. HTTP interface (DCM007A51) is also required.
*5. PPD option
® (DCM002A51) for iTM is also required.
*2. BACnet is a registered trademark of American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).
*3. LonWorks® is a trademark of Echelon Corporation registered in the United States and other countries.
Option
List
101
103 212
98 99 102
104
MEMO
Users download CAD symbol drawing materials, including 2D CAD symbols and
3D Revit data, for VRV systems designing. The 3D Revit data contains
specifications for Daikin products, including things like capacities and electric
characteristics to support Business Information Modeling (BIM).
103
105 100 107 104
106
MEMO MEMO
Users download CAD symbol drawing materials, including 2D CAD symbols and
3D Revit data, for VRV systems designing. The 3D Revit data contains
specifications for Daikin products, including things like capacities and electric
characteristics to support Business Information Modeling (BIM).
105
107
105 106100 107 106
106
VRV X Series Catalogue
U
contractor to install those parts and accessories. Use of unauthorised parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
Read the user's manual carefully before using this product. The user's manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.
Specifications, designs and other content appearing in this brochure are current as of July 2021 but subject to change without notice.
c All rights reserved 07/21 SS