2/4-Wire SHDSL Modem

FEATURES • Features X.21, V.35, RS-530, • Major and minor alarm relay
G.703/G.704 E1/T1 and • SHDSL repeaters for
• Dedicated managed SHDSL Ethernet interfaces, allowing increased transmission
modem connection to different DTE distance
types
• Operates over 2-wire and • Available in a half 19-inch
4-wire lines, enabling service • Supports an embedded metal or plastic enclosure,
over any copper operation channel for suitable for side-by-side rack
infrastructure end-to-end system mounting, or in a
management and
• Utilizes TC-PAM line coding supervision, as per rail-mounting metal
for extending the operation enclosure
ITU-T G.991.2
range to up to 10 km • Available as a dual- or
(6.2 miles) • Management via: quad-modem card for RAD’s
• Operates at multiple data V.24/RS-232 terminal port LRS-24 modem rack with
rates between 64 kbps and 10/100BaseT out-of-band SNMP management
4608 kbps, enabling management port • Fully compatible with RAD’s
single-platform system Dedicated E1/T1 timeslot LRS-52 dedicated SHDSL
upgrades modem rack
• Provides extensive
diagnostics, including
loopbacks, SHDSL and E1
performance monitoring
ASMi-52
2/4-Wire SHDSL Modem
DESCRIPTION • The modem uses an Embedded • The ASMi-52CQ card contains
Operation Channel (EOC) for four SHDSL modems that operate
controlling and monitoring the over 2-wire lines. It supports only
• ASMi-52, an SHDSL modem, remote unit. The management serial and E1 DTE interfaces.
operates in full-duplex mode over channel uses SHDSL overhead bits
2-wire and 4-wire lines. • The ASMi-52CD and ASMi-52CQ
in compliance with ITU-T G.991.2 cards support internal, external
• Multiple data rates in the range of requirements, operating without and system timing modes.
64 to 4608 kbps are supported. interfering with the data
The data rates depend on the line transmission. • Supervision and configuration
activities are performed using an
interface, DTE interface types, and • ASMi-52 units operate opposite ASCII terminal, IP hosts using the
operating clock modes. centrally located LRS-52 and Telnet protocol, Web-based
• ASMi-52 employs standard SHDSL ASMi-52CD/ASMi-52CQ cards ConfiguRAD, or RADview-EMS,
TC-PAM technology to extend the installed in a LRS-24 rack (Java-based, modular, client-server,
transmission range (see Table 1), (see Figure 1). scalable element management
thus enabling carriers to reach • User-configurable low-speed mode system), providing secure
more customers at lower costs. is available for units with serial and configuration and fault
• The following DTE interfaces are LAN interfaces. In this mode ASMi- management capabilities.
available: X.21, V.35, RS-530 and 52 supports 64/128 kbps (2-wire) The terminal port supports a
G.703/G.704 E1 or T1. For and 64/128/256 kbps (4-wire) data dial-up modem connection for
LAN-to-LAN connectivity using rates when operating opposite remote management of ASMi-52
SHDSL technology, the modem devices with E1 DTE interface. The over telephone lines.
supports a built-in 10/100BaseT maximum data rate in the low-
speed mode is 2048 kbps. SNMP management can be
bridge Ethernet port with VLAN performed via a 10/100BaseT port
support (IR-ETH/QN), or an IP • Up to eight SHDSL repeaters can or dedicated E1/T1 timeslot.
router (IR-IP). be installed in line to increase the Note: For ASMi-52 units with a serial DTE
• A modem with a 4-wire line operation range of the modem. interface, the 10/100BaseT port serves for
interface can be configured to ASMi-52 provides basic management only.
operate over 2-wire lines. management of the repeaters. When ASMi-52 is ordered only with the
• The ASMi-52CD card includes two 10/100BaseT port, it is used to transfer the user
and management data.
SHDSL modems that operate over
2- and 4-wire lines and support a • The minor and major alarms can
wide range of serial, be relayed to a remote alarm
E1 and Ethernet DTE interfaces. device via an optional terminal
block port.
APPLICATION

Figure 1. ASMi-52 Modems Operating opposite ASMi-52CD Cards over 2- and 4-Wire Lines
ASMi-52
2/4-Wire SHDSL Modem
• Comprehensive diagnostic • Connectors • Ethernet Port
capabilities include: ASMi-52: RJ-45 Interface: 10/100BaseT
Real-time alarms to alert user on ASMi-52CD: Two RJ-45 Connector: RJ-45 shielded
fault conditions ASMi-52CQ: Four RJ-11 or
terminal blocks GENERAL
V.54 local analog and remote
digital loopbacks
• Timing
DTE INTERFACE Standalone ASMi-52:
SHDSL and E1/T1 statistics • Type Internal, from internal oscillator
collection for 15-minute and ASMi-52: External, from attached DTE
24-hour intervals. X.21 – 15-pin, D-type, female Receive, from received signal
• The modem provides high-voltage V.35 – 34-pin, female (CPE only)
line protection in compliance with RS-530 – 25-pin, D-type, female ASMi-52CD, ASMi-52CQ:
ITU K.21 and UL1950 G.703/G.704 E1 – RJ-45 Internal, from internal oscillator
requirements. T1 – RJ-45 External, from attached DTE
IR-IP (IP router) – RJ-45 Station, from external clock
Table 1. Typical Ranges (26 AWG) source via LRS-24
ETH (10/100BT bridge with VLAN
Data 2-wire 4-wire support) – RJ-45 • Diagnostics
Rate Loopbacks:
ASMi-52CD:
[kbps] [km] [miles] [km] [miles] V.35, X.21, RS-530 – 2 × SCSI-26 Local analog loopback in
compliance with ITU V.54
64 7.5 4.6 — — IR-ETH (10BT bridge), IR-ETH/Q Remote digital loopback in
128 7.0 4.3 7.1 4.4 (10BT bridge with VLAN support), compliance with ITU V.54
256 6.7 4.1 6.8 4.2 IR-ETH/QN (10/100BT bridge with Performance monitoring:
VLAN support) – 2 × RJ-45 SHDSL statistics collection
384 6.5 4.0 6.7 4.1
E1 balanced – 2 × RJ-11 E1 with CRC-4 or T1 with ESF
512 6.3 3.9 6.6 4.1 E1 unbalanced – 25-pin, D-type, framing: per ITU G.706
1024 5.3 3.3 6.0 3.7 female E1 without CRC-4 or T1 with SF
1536 5.0 3.1 5.6 3.5 ASMi-52CQ: framing: BPV
2048 4.5 2.8 4.7 2.9 V.35, X.21, RS-530 –SCSI-68 • Indicators
2304 4.2 2.6 4.5 2.8 E1 balanced – 4 × RJ-11 PWR (green) – Power
E1 unbalanced – 25-pin, D-type, DATA (yellow) – Transmit data
4096 – – 3.7 2.3
female (except E1 or T1 interface)
4608 – – 3.0 1.8
• Data Rate SYNC A/B (green/red) – Sync status
Notes: The typical ranges are based on error-free Depends on the DTE/line interface of DSL line
lab tests without noise. ASMi-52CD/4W type and clock mode: E1 or T1 SYNC (red) – Loss of E1 or
operates at data rates up to 4608 kbps, 2-wire: 64–2304 kbps (ext. clock), T1 sync (E1 or T1 interface only)
depending on internal or external clock.
64–2048, 2304 kbps (int. clock AIS (yellow) – “All 1s” string is
4-wire: 64–4608 kbps (ext. clock), received (E1 or T1 interface only)
SPECIFICATIONS 64–4096, 4608 kbps (int. clock) ALM (red) – Alarm enters the buffer
ASMi-52CD/4W: TST (red) – Test in progress
LINE INTERFACE 128–4608 kbps (ext. clock),
• Type • Power
128–4096, 4608 kbps (int. clock) AC/DC: 100–240 VAC,
2/4-wire unconditioned dedicated
line (twisted pair) • Coding -48/-60 VDC nominal
E1: HDB3 DC: 24 VDC
• Line Coding T1: B8ZS or AMI • Power Consumption
TC-PAM Standalone ASMi-52:
• Line Impedance
• Range E1: 120Ω, balanced or 75Ω, 7W max (4-wire)
See Table 1 unbalanced (via adapter cable) 6W max (2-wire)
• Impedance T1: 100Ω, balanced ASMi-52CD:
135Ω 7.5W max (2-wire)
MANAGEMENT PORTS 10W max (4-wire)
• Standards • V.24/RS-232 CONTROL Port ASMi-52CQ:
ITU-T 991.2, ETSI 101 524 8.5W max
Interface: V.24/RS-232 DTE
• Protection Connector: 9-pin D-type, female
As per ITU K.21 and UL1950 Format: asynchronous
• E1 Jitter Performance Baud rate: 9.6 to 115.2 kbps
As per ITU G.823
ASMi-52
2/4-Wire SHDSL Modem
• Environment Note: For E1 unbalanced, order cable ASMi-52CD Cables
Temperature: CBL-RJ45/2BNC/E1. CBL-SCS26/530/F
Standalone: 0–50°C/32–122F Standalone ASMi-52 only: One SCSI-26 to one female
Card: 0–50°C/32–122F T1 for T1 interface RS-530 (DB-25) connector
Rail-mount: −20–70°C/−4–158F ETH for 10/100BaseT port CBL-SCS26/X21/F
Humidity: ASMi-52CD, ASMi-52CQ only: One SCSI-26 to one female X.21
Up to 90%, non-condensing E1B for E1 balanced interface (DB-15) connector
Shock (Rail-mount): E1UB for E1 unbalanced interface
IEC 60068-2-27 shock 15g, CBL-SCS26/V35/F
UTPQN for IR-ETH/QN interface One SCSI-26 to one female V.35
11 ms duration, 18 shocks
Vibration (Rail-mount): @ Specify 24V for 24 VDC option. (34-pin) connector
IEC 60068-2-6 vibration 1 mm, Note: Omit @ for VAC or -48 VDC option. The CBL-LRSI25/DB25/UB/M
internal power supply accepts both AC and DC. One DB-25 to four male BNC
2Hz–13.2 Hz, 90 min.;
An AC/DC adapter is supplied with the unit for
0.7g, 13.2 Hz–100 Hz, 90 min.; coax connectors
-48 VDC power connection
3.5 mm, 3Hz–9Hz, 10 cycles, ASMi-52CQ Cables
1 octave/min.; 1g, 9 Hz–150 Hz ^ Specify chassis type: CBL-CQ-RS530/F
10 cycles, 1 octave/min. F for ETSI-type LRS-24 rack One SCSI-68 to four female
• Physical B for ANSI-type LRS-24 rack RS-530 (DB-25) connectors
Plastic enclosure: # Specify line interface: CBL-CQ-V35/F
Height: 43.7 mm / 1.7 in 2W for 2-wire interface One SCSI-68 to four female V.35
Width: 240 mm / 9.4 in 4W for 4-wire interface (34-pin) connectors
Depth: 170.5 mm / 6.7 in CBL-CQ-X21/F
Weight 0.5 kg / 1.1 lb % Specify ETH for the out-of-band
One SCSI-68 to four female X.21
10/100BaseT management port
Metal enclosure: (DB-15) connectors
Height: 47.3 mm / 1.8 in (ASMi-52 units with serial DTE
interfaces only) CBL-LRSI21/DB25/UB/M
Width: 215 mm / 8.4 in One DB-25 to eight male BNC
Depth: 147 mm / 5.8 in $ Specify AR for 6-pin alarm relay coax connectors
Weight 0.7 kg / 1.5 lb port CBL-LRSI21/DB25/UB/F
Rail-mount metal enclosure: ? Specify ME for metal enclosure One DB-25 to eight female BNC
Height: 150 mm / 5.9 in coax connectors
Width: 70 mm / 2.7 in & Specify line interface connector:
Depth: 160 mm / 6.3 in RJ for RJ-11 line connector RM-33
Weight 0.75 kg / 1.65 lb TB for terminal block line connector Hardware kit for mounting one
Note: ASMi-52CQ cards with E1 DTE interface ASMi-52 unit in plastic enlosure into
ORDERING are available with terminal block line connectors a 19-inch rack
only.
ASMi-52/@/*/#/%/$/? RM-35
2/4-wire SHDSL standalone modem RAIL-MOUNT ENCLOSURES Hardware kit for mounting one or
ASMi-52CD^/*/#/RJ-45 two ASMi-52 units in metal enclosure
ASMi-52/24/ETH/4W/ME/AR/RAIL into a 19-inch rack
Dual-modem card version for 4-wire SHDSL rail-mount modem
LRS-24 modem rack
24V version data communications
ASMi-52CQ^/*/2W/& ASMi-52/ETH/4W/ME/AR/RAIL
Quad-modem card version for 4-wire SHDSL rail-mount modem www.rad.com
LRS-24 modem rack
VAC or -48 VDC version International Headquarters
* Specify DTE interface: Note: The line inteface is TB in rail-mount versions. 24 Raoul Wallenberg Street
Tel Aviv 69719, Israel
Note: The ASMi-52 cards support the following
DTE interfaces: CABLES Tel: (972) 3-6458181
Fax: (972) 3-6498250, 6474436
• ASMi-52CD/2W: IR-ETH/QN, IR-IP, E1, Note: Cables are not supplied with the modems
Email: market@rad.com
X.21, V.35 and should be ordered separately.
• ASMi-52CD/4W: X.21, V.35, RS-530, E1, U.S. Headquarters
IR-ETH/QN, IR-IP
ASMi-52 Cables 900 Corporate Drive
• ASMi-52CQ: X.21, V.35, RS-530, E1, T1. CBL-RJ45/2BNC/E1 Mahwah, NJ 07430
For all ASMi-52 types: Interface adapter for converting Tel: (201) 529-1100
X.21 for X.21 interface balanced E1 RJ-45 connector into Toll free: 1-800-444-7234
Fax: (201) 529-5777
V.35 for V.35 interface a pair of BNC unbalanced coaxial Email: market@radusa.com
RS530 for RS-530 interface connectors
148-100-06/05
IP for IR-IP module
E1 for E1 interface
 1989–2005 RAD Data Communications Ltd. Specifications are subject to change without prior notice.