You are on page 1of 12

PROCool

www.ako.com
Introduction PROCool

PROCool is the complete electronic solution for Offers:


managing refrigeration installations, both positive and - Quick start-up thanks to its quick programming menu.
negative up to 25 A (I /III). - Large Display for better visibility.
- Hot keys with the most common functions
- IP65 for installation in humid environments
- Light weight for easy installation

www.ako.com
¿What it controls ? PROCool
The PROCool electrical panels are designed for complete control of the cold room:

Condensing units (formed by compressor + Evaporating units (formed by Fans +


condenser fans) defrost heaters - if any)
Compressor Condenser fans Fans Defrost

Monophasic (I) Monophasic (I) Monophasic (I) Air


Triphasic (III) Triphasic (III) Monophasic (I) Electrical (I)
Triphasic (III) Air
Triphasic (III) Electrical (III)

www.ako.com
Functions PROCool

Panel details

Control circuit:

Automatic Pump Down, configurable by parameter.

Defrost control combined with Pump Down

Digital inputs for door contact, for stoppage of fans and solenoid when opening the
door, improving so the energy efficiency

Stand-by control for evaporator shutdown

www.ako.com
Functions PROCool

Panel details Components location

Compressor motor guard + condenser fan 1 (depending on model)

Protections (general circuit-breaker and operational circuit breaker)

Compressor contactor and defrost contactor

www.ako.com
Display and Key Functions PROCool

Pressing it for 5 seconds activates the Stand-By


mode.

One short press* shows the non-displayed probe


2 reading (see P8 parameter).
Pressing it for 5 seconds starts/stops the defrost.

Pressing for 5 seconds accesses the quick


configuration menu (SP,d0,d1,F3,A1,A2,P26)
Pressing for 10 seconds accesses the advanced
configuration menu.

One short press* displays the current set point


value (SP).
Pressing it for 5 seconds accesses change set
point.

www.ako.com
Parameter list PROCool

The parameters are grouped into 6 sections depending on their function. To access it, press the key for 10 seconds.

www.ako.com
Components to connect PROCool

Condensing unit

Thermistor

High/low pressure switch

Evaporator

Solenoid

www.ako.com
Without Pump Down PROCool

Set up parameter P26=0

www.ako.com
Product range PROCool

www.ako.com
Aplications PROCool

For being so versatile (with adjustable motor protector), it’s possible to cover many applications with just one
model:

½ - 1 HP 1,5 - 2 HP

3 - 4 HP 5 – 7,5 HP

Ajustable motor
protector from 3 to
25A
8 – 9 HP 10 HP

It would take 6 references of


conventional panels 1 PROCool reference

www.ako.com
www.ako.com

www.ako.com

You might also like