This document summarizes the results of a test of the Z axis on a machine called HMC -72. The test was conducted on May 30th, 2022 and analyzed the maximum and average reversal and scatter values for the Z axis, which were all within specifications. Environmental conditions like temperature and pressure remained stable during the test.
This document summarizes the results of a test of the Z axis on a machine called HMC -72. The test was conducted on May 30th, 2022 and analyzed the maximum and average reversal and scatter values for the Z axis, which were all within specifications. Environmental conditions like temperature and pressure remained stable during the test.
This document summarizes the results of a test of the Z axis on a machine called HMC -72. The test was conducted on May 30th, 2022 and analyzed the maximum and average reversal and scatter values for the Z axis, which were all within specifications. Environmental conditions like temperature and pressure remained stable during the test.
Machine name HMC -72 Serial number 12005209-4 Targets 12 Linear
Axis under test C Number of runs 3 Alternate bidir Test date Monday 2022/05/30 05:15 PM
ZTZ - Analysis features Environmental conditions
Name Value (µm) Name Start End Min Max Maximum reversal (U max) 5.5 Air temp [°C] 36.2 36.2 36.2 36.3 Maximum scatter (Ps max) 2.5 Air pressure [mbar] 993.40 993.40 993.40 993.40 Mean reversal (U Mean) 2.4 Air humidity [%RH] 52 52 52 52 Mean scatter (Ps mean) 1.1 Material temp 1 [°C] Not recorded Not recorded Positional uncertainty (P) 7.5 Material temp 2 [°C] 35.5 35.5 35.5 35.5 Positional deviation (Pa) 1.9 Material temp 3 [°C] Not recorded Not recorded Expansion coefficient [ppm/°C] 11.70 11.70