You are on page 1of 1

Page 1 of 1

Ballbar diagnostics table


ZX 220deg 100mm Calibrated
Operator: senba Machine: HMC 72
Date: 2022-May-30 18:11:54 QC20-W: 2XNW49, Last calibrated: 2021-03-18

Error Magnitude Independent Ranking


circularity
Backlash Z 4-2.1 2.1µm (5%) (7)
Backlash X 52.9 62.6µm 2.9µm (7%) (5)
Reversal spikes Z 4-5.4 5.4µm (13%) (2)
Reversal spikes X 5-3.4 6-2.3µm 3.4µm (8%) (4)
Lateral play Z 41.5 31.6µm 1.5µm (4%) (8)
Lateral play X 51.3 61.4µm 1.4µm (3%) (10)
Cyclic error Z á3.8 â3.6µm 3.5µm (8%) (3)
Cyclic error X á2.2 â2.2µm 2.1µm (5%) (6)
Servo mismatch 0.09ms 1.5µm (4%) (9)
Squareness -183.7µm/m 18.4µm (43%) (1)
Cyclic pitch Z 20.0000mm
Cyclic pitch X 30.4800mm
Calculated feedrate 997.3mm/min
Centre offset Z 0.0µm
Centre offset X -19.7µm
Best fit radius 100.0053mm
Circularity 25.1µm

Test parameters
Radius 100.0000mm
Feedrate 1000.0mm/min
Start/End/Overshoot 250°/110°/2°
Run sequence CW CCW
Test position
Sample rate 40.000Hz

res://renishaw.calibration.ballbar.analysis.renishawdiagnostics.dll/TABLE.htm 01-06-2022