Mega Tester V3
Brief Instruction
0.019
Front view
Previous test button
Parameter change knob
Start / Stop button
Display
Start
Stop
Mega Tester V3
Rear view
Warning
! Do not connect or disconnect injector while test is in progress
Page 2 of 3
Mega Tester V3
Brief Instruction
0.019
Required voltage
U: 125 V 3.
4.
Wait for voltage stabilization
Measure actuator stroke
(select by knob) US: 125 V 5.
6.
Repeat steps 3 through 5 if required
Press "Start/Stop" button to stop
Test name Stroke
Injector type
Gap test (select by knob long press)
Gap between
VDO
piezoactuator and
CR 1. Press "Start/Stop" button to start
driving valve pin D: 3.5 µm 2. Observe gap value
3. Rotate actuator nut until required
gap is set
Test name Gap 4. Press "Start/Stop" button to stop
Mega Tester V3
Brief Instruction
0.019
Error indication
Wrong cable Error indicator appears
is connected when something is going
wrong during the test
Device can't apply
required voltage to
the piezoactuator Press button for
error description
Options setup
Long press button to enter setup
Select language Rotate knob to change value
Language Eng
Set sound on/off Sound On
Press and button
Gap QBPV to select option
Select gap
measurement method
Gap QBPV
Select default voltage
Select default voltage Ur 20V for insulation
for piezoactuator resistance measurement
resistance measurement Ui 300V
Some notes
∞ sign means that device can't measure resistance because resistance is too big.
In the insulation resistance test it is more than 11 GΩ.
In the piezoactuator resistance test it is more than 1.1 GΩ.