You are on page 1of 6

RWF II

Rotary Screw
Compressor Units
The RWF II Advantage
Motor Flange

Smart Series™
Motors
Frick® Variable Vi
Cold-Start
Valve

Mounted
Starters
Quantum™LX
Control Panel

SuperFilter™II/
Dual Filters

Motor Flange – Eliminates both cold and hot alignments. External Oil Cooling – Eliminate capacity and power
Frick® RWF II comes standard with flange-mounted motors. penalties by using Frick’s thermosyphon or water-cooled
Alignment is machined into the parts at the factory. oil cooler. Both use the latest technology in plate design
Think Frick® ! Think flange-mounted motors. and are constructed according to ASME Section VIII
Division I.
SuperFilter™II – Efficient oil management leads to longer
bearing life. SuperFilter™II cleans oil cleaner than new. It Smart Series™ Motors – NEMA premium efficient,
captures 99% of particles 5 microns and larger and has low noise motors are standard on Frick® compressor
twice the dirt holding capacity of the original SuperFilter™ packages. These Smart Series™ motors are quiet,
for maximum bearing life. economical, and energy efficient.
EZ Cool™ – Our coolest option for compressor packages Mounted Starters – Frick® factory-mounted
uses a motorized expansion valve for liquid injection compressor motor starters have superior motor overload
applications to improve compressor efficiency. EZ Cool™ is protection, require less mounting space, and reduce
controlled by the Frick® Quantum™LX panel. installation costs.
Vyper™ Variable Speed Drive – Responds to
Cold-Start™ Valve – The energy saving standard, changing capacity by varying motor speed instead
Frick® compressor packages are designed specifically for of moving the slide valve. It provides better part-load
operation without an oil pump under normal operating efficiency, reduces energy consumption, and generates
conditions. While some low-pressure differential more consistent suction pressure control.
applications require a demand pump, it operates only
when needed and automatically shuts off to conserve Compact Size – Reduce your engine room size for
motor power when not required. Our Cold-Start standard greater space savings. RWF II compressor packages are
maximizes efficiency. compact to save construction costs.
Easy to Service – Frick® keeps the service technician
Frick® Variable VI – Eliminate power penalties from
in mind. All critical package components for service and
over-compression or under-compression. Our method of
maintenance are easy to reach and located on the same
varying internal volume ratio to match the system pressure
side of the package.
ratio is patent protected. Never duplicated.
PhD Vibration Protection – PhD vibration
Dual Oil Filters – Serviceability is serious business. protection helps stop interruptions before they start.
Mount a second oil filter on your Frick® compressor Protect your motor and compressor. Order PhD for your
package to ensure continuous operation during service of next RWF II package.
the primary filter. Isolation valves are included.
Quantum™LX is Standard – Quantum™LX control
No Leaks – Integrated internal oil passages eliminate the panels make equipment management easy. All RWF II
potential for leaks with RWF II. No welds. No worry. compressor packages arrive ready to operate.
Why specify and install RWF II?
The Best Just Got Better!
From any angle, RWF II makes a design statement. It’s sleek new lines
are the perfect size and height for start-up applications, keeping space
requirements and building costs to a minimum. Existing facilities get a
new lease on life for expansion. Just 10’ 5” x 5’ 3” (Model 134), RWF II
fits the smallest of spaces to expand operating capacity without new
construction.
RWF II combines the best in size with the best in operation and
durabilitly. Smart Series™ motors have a robust design for industrial duty.
Special Vacuum Pressurized Impregnation (VPI) of the windings is a
Frick® exclusive that protects motors in the rigorous environment of an
industrial engine room.
The new, mounted solid-state starter is designed to reduce power
consumption during start-up and to keep the field technician in mind.
The in-line starter uses a traditional connection configuration that is
easily understood by electricians. Our newest starter is positioned
directly beneath the motor on the compressor package to reduce overall
length and ensure a clean look for your engine room.
For any environment, new or old, RWF II conveniently positions critical service points and openings on a single side.
Efficient rows of packages can hug the wall and still mean easy maintenance.

Frick RWF II ... a great layout solution.


®

Major Applications
Blast Freezing Cold Storage
Blast freezing applications like frozen vegetables, Precise temperature controls for perishable food
meats, or prepared meals require control flexibility to storage environments utilize the industry’s most
match changing system loads. The RWF II’s patented efficient energy management strategies. The RWF II
method of controlling refrigerant compression solution fits perfectly in this application.
during continuous operation (Variable VI) eliminates
the power penalty associated with over/under Test Chambers / Environmental
compression. RWF II matches the internal volume
The temperature specifications for environmental
ratio with the system pressure ratio automatically for
testing facilities often have unique refrigeration
superior performance.
requirements. Precise temperatures are needed for
Food Tempering defined time periods, changed on a predetermined
schedule. The latest technologies, packaged only
Some Food products, like pork and other meats, in RWF II, can manage the most challenging test
require special temperature adjustments during environments.
processing to prepare them for the next step. The
RWF II is equipped with automated controls to Others ???
change the temperature during processing without
Have a new application?
manual intervention. Let Frick® make the changes
Tell us about your latest requirements.
that maximize your system efficiency.

Beverage / Bottling
Refrigeration applications for breweries, soft drinks,
and other beverages require quick response and
flexibility. The RWF II can help meet these needs with
its automated capacity control features.
LX - Another Quantum Leap
Everything you like about your Quantum™ is still at your fingertips. But the best
has gotten better. Our new LX display has contemporary graphics that are even
easier to read and navigate, just like the web. For today’s home computer user,
the look and feel of Quantum™LX is second nature.
Our simple graphical interface is perfect for your newest users … while our
advanced interface has detail to satisfy even your most experienced operators…

Quantum™LX, the first compressor controller to


accommodate your complete workforce.

Quantum™LX leaps forward with significant improvements!

Improved capacity control Complete port configuration


• Four user-defined modes Up to three serial communication ports
Improved Sequencing with any protocol
• Three suction levels
Ethernet
• Up to eight compressors per level
• Modbus TCP
• Uses Ethernet for high speed communications
• Ethernet IP
• High stage/booster interlock between levels
• Web Accessible
Improved communications See screens as though you
Supported serial protocols: were standing in front of the
• Frick® compressor using any standard
• Modbus ASCII Internet Browser!
• Modbus RTU
• Allen-Bradley® DF1

Menu for
Quick Navigation

Reduced Screens/
Reduced complexity

Stop/Start Back Space/Up/Tab


Unload/Load Left/Down/Right
Alarm Silence/ Submit/Enter/Menu
Manual Mode
Web Look and Feel
Use Frick® Quantum™ and Q-Talk to
Link Your Entire Refrigeration System.
Get Optimum performance
When You “Take Control.”

System Integration Is What We Do!


www.frickcold.com
Form M70-610 SG1 (106) FRICK
Supersedes: M70-610 (1204) 100 CV Avenue • P.O. Box 997
Subject to change without notice Waynesboro, PA USA 17268-0997
Printed in USA • GUI 2000 106 2.40 Phone: 717-762-2121 • FAX: 717-762-8624
© 2006 Johnson Controls Inc. - ALL RIGHTS RESERVED www.frickcold.com

You might also like