Manifolds
Manifolds are available in a variety
of styles and are designed to be
interchangeable. There are a number of
considerations when selecting a manifold.
In a multi-user lab it is often best to utilize
a robust stainless steel manifold. In
applications where inorganic solvents are
being utilized or you are rack drying and
want to ensure visibility an acrylic manifold
would be preferred. In applications
with organic solvents the stainless steel
manifolds will provide long lasting use.
03
Omnitronics Controller
The Omnitronics Controller simplifies freeze drying control, you can connect the freeze dryer to your
and makes the system easy to operate. One touch company’s or institution’s network, and monitor
start up and shut down ensure that your product and/or control your freeze dryer from any other
and freeze dryer are protected from inappropriate location on the network. The Ethernet option
procedures. The graphic display provides at-a- also allows print out in a batch record, alpha-
glance understanding of the status of the freeze numeric, type report.
dryer and whether or not appropriate freeze drying
conditions exist. Audible alarms help notify the One touch start up and shut
user of potential problems with the system and
hence, with the product. All Omnitronics controllers down ensure that your product
come complete with a trending screen that allows and freeze dryer are protected
you to watch critical parameters on an on-going from inappropriate procedures.
basis if required. Utilizing the optional Ethernet
04
Don’t waste time with
slow & messy defrosting
05
VirTis/SP Scientific supports your freeze drying endeavors with a team of technically
qualified associates who can help you choose the right system and provide you with
helpful application tips. In addition, SP Scientific provides the globally recognized
LyoLearn Webinar series. These are free webinars, provided by industry experts on topics
of interest to the freeze drying community. Our technical papers and application notes
can be downloaded from our website at your convenience and are designed to help you
get the most out of your freeze dryer.
06
Features of the BenchTop Pro
• Condensers of 3, 8 and 9 liters in a bench top
footprint
• Refrigeration packages for maximum low
temperature of -55°, -75°, -85° or -105°C
• One touch start-up and shut-down
• Pressure control to avoid back-streaming or for
faster freeze drying
• A variety of manifolds to accommodate most
processing configurations
• Rugged and reliable Pirani vacuum sensor
• Hot gas defrost in approximately 10 minutes or
less
• Optional vacuum pump isolation valve
Selection Guide
There are two main criteria for selecting the benchtop freeze dryer that is right for
you. The first is determining what condenser capacity you need in between defrost
cycles. The second is to determine what solvents you may be using in your process.
When utilizing water as the only solvent the highest condenser temperature offered is
appropriate. In cases where organic or inorganic solvents are being utilized as part
of the solvent matrix the lowest temperature condenser is always preferred.
Load Capacity Vacuum Pump
Manifold Material Choice
Solvents 3 Liter 8 Liter 9 Liter Considerations
Standard oil sealed, rotary vane direct
Water ES (-55°C) XL (-75°C) ES (-55°C) Acrylic or stainless steel. Multiple user labs may drive pump. When working in low
have better experience with stainless steel. pressure conditions consider a dry scroll
pump if oil backstreaming is a concern.
Water and inorganic solvents XL (-75°C) ZL (-105°C) EL (-85°C) Maximize use of acrylic and minimize use of Standard pump with corrosion resistant
stainless steel. oil or combination standard pump with
diaphragm pump.
Water & organic solvents XL (-75°C) ZL (-105°C) EL (-85°C) Maximize use of stainless steel and minimize Standard pump with corrosion resistant
use of acrylic if possible. oil or combination standard pump with
diaphragm pump.
Water & both organic and inor- XL (-75°C) ZL (-105°C) EL (-85°C) Maximize use of acrylic if higher in organic Combination standard pump with
solvents. Maximize use of stainless steel if diagphragm pump.
ganic solvents higher in organic solvents.
07
BenchTop Pro with
Omnitronics
3L Freeze Dryer
The BenchTop Pro with Omnitronics
3 Liter system is designed as
a personal freeze dryer or for
small laboratories processing less
product at any one time. This unit
is available with all of the manifold
choices that can be used on the BenchTop Pro with Omnitronics 3 Liter Freeze Dryer
larger benchtop system giving it the Condenser blank off (no load) ES -55°C (-52°C for 50Hz) / XL -75°C
temperature (-72°C for 50Hz)
same flexibility and performance.
Condenser capacity in 24 hours Approximately 2 Liters
(water, heaviest load)
• Condenser temperature option of
-55°C (-52°C for 50Hz) or -75°C Overall condenser capacity 3 Liters
(-52°C for 50Hz) or -85°C (-85°C * Vacuum indication in millitor, microbar Atmospheric to 1 mT
or pascals (user selectable)
for 50Hz)
* Temperature indication in °C or °F "T" type thermocouples
• CFC free refrigerants (user selectable)
• Condenser capacity total of 9 liters * Voltage and ambient temperature Alarms if out of acceptable range for
• Approximate 24 hour rating of 5 indicators system
liters/24 hours (extreme pressure * Communication ports Ethernet connection
and temperature, water only)* Defrost Method Hot gas
• Omnitronics Control for monitoring System refrigerant CFC free
critical freeze drying parameters Condenser type Internal Coil
and for vacuum control Compressor(s) ES is 1/3 HP, EL is 1/3 HP and 3/8
• Remote control, batch reporting HP
and emailed alarms with Ethernet Average time for pull down to 100 mT 18 minutes
interface Ultimate system vacuum with manifold 20 mT
• Fast turn around with hot gas Base cabinet dimensions W x D x H 15.5in x 28.5in x 17in (39.4cm x
72.4cm x 43.2cm)
defrost.
Weight (lb/kg) 131 lbs (59.4 kg)
• Alarms for out-of range-conditions
(unpackaged and without manifold)
*The 24 hour rating is not reproducible Standard Voltages 100-120V 50/60Hz, 200-240V
in the lab with product. This rating is to 50Hz/208-230V 60Hz
illustrate the efficiency of the refrigeration
design from one system to another. It is
based on loading as much water onto the Manifold and Vacuum Pumps Sold Separately
freeze dryer in 24 hours as possible with - See Accessories
equipment not typically used in freeze
drying applications
Current as of May 2013; Specifications are subject to change
10
Accessories for the BenchTop Pro
Tree or “T” type Manifolds
Available in 8 or 12 port configuration. 316 Stainless steel complete with Quick
Seal Valves and built in adaptor plate.
Vertical Manifold
Available in 12 port configuration. 316 stainless steel complete with Quick Seal
Valves and built in adaptor plate.
11
Drum Manifolds
Classic drum type manifolds are available in both stainless steel and acrylic
configuration. Comes complete with condenser adaptor plate of same material.
Accessory racks can be coupled with these manifolds for rack drying—either heated or
unheated.
BTP-DA-12-0 12 port acrylic drum manifold DRUM – HEIGHT 16.25” (41.28 CM) ID, 18”
(45.72 CM) OD, WIDTH Ø11.5” (29.21 CM)
ID, Ø 12” (30.48 CM) OD
ADAPTER PLATE – HEIGHT 1” (2.54 CM),
WIDTH Ø15” (38.1 CM),
OVERALL ASSEMBLY – HEIGHT 18.75”, WIDTH
Ø20.5” (52.07 CM) WITH QUICK SEAL VALVES
INSTALLED
BTP-DA-12-H 12 port acrylic drum manifold DRUM - HEIGHT 16.25” (41.28 CM) ID, 18”
for use with heated racks (45.72 CM) OD, WIDTH Ø11.5” (29.21 CM)
ID, Ø12” (30.48 CM) OD
ADAPTER PLATE - HEIGHT 1.5” (3.81 CM),
WIDTH Ø15” (38.1 CM)
OVERALL ASSEMBLY – HEIGHT 19.25”, WIDTH
Ø20.5” (52.07) WITH QUICK SEAL VALVES
INSTALLED
BTP-DS-18-0 18 port stainless steel drum DRUM - HEIGHT 13” (33.02 CM) ID, 13.25”
manifold (33.66 CM) OD, WIDTH Ø12” (30.48 CM) ID,
Ø13” (33.02 CM) OD
SST ADAPTER PLATE – HEIGHT 0.25” (0.64
CM), WIDTH Ø15” (38.1 CM)
ACRYLIC COVER – HEIGHT 0.75” (1.91 CM),
WIDTH Ø13.5” (34.29)
OVERALL ASSEMBLY – HEIGHT 14.25” (36.2
CM), WIDTH Ø21” (Ø53.34 CM) WITH QUICK
SEAL VALVES INSTALLED
Drum Manifold Racks
Racks are constructed of 304 stainless steel and adjustable.
BR-3U-12 3 tiered rack for BTP-DA-12 HEIGHT 14.5” (36.83 CM), WIDTH Ø10.5
(26.67 CM), SPACING 4.75” (12.07 CM)
BR-3U-18 3 tiered rack for BTP-DA-18 HEIGHT 12” (30.48 CM), WIDTH Ø10.5
(26.67 CM), SPACING 3.75” (9.53 CM)
BR-3H-13 3 tiered rack for BTP-DA-12 with HEIGHT 12” (30.48 CM), WIDTH Ø8.5 (21.59
on off heater CM), SPACING 4.75” (12.07 CM)
12
Wide Mouth Filter Seal Flasks
These borosilicate flasks are specially designed for manifold freeze drying. The flat
bottom makes it easy to stabilize the flask in its upright position for “plug” or static
freezing. The wide mouth of the flask makes it easier to place product in the flask and
perhaps even more importantly, remove product from the flask. The snap on silicone top
ensures a good vacuum seal and comes complete with a filter to eliminate the possibility
of cross contamination when several flasks are on the same dryer. All components can
be autoclaved. The flask itself is available in regular and in safety coated configurations.
Must be used with manifold adaptors.
Manifold Adaptors
13
Ampule Adaptor
Designed to hold 19 ampule type containers on a single valve
We also carry a full line of sealing torches and ampules. Please inquire.
Container System
Two container systems are offered. One for bulk and one for stoppering
applications. Containers are made of 304 SS and are attached to your
manifold with vacuum tubing for processing in bulk or in vials.
Vacuum Pumps
Vacuum
Foreline Traps Part Number Description
FTA Filter trap housing, insert
purchased separately
These traps are designed to
help prevent the migration of FTA-SS Soda sorb insert for acid applications
contaminants to the vacuum FTA-AC Activated charcoal insert for organic solvent appli-
cations
pump or to minimize vacuum
pump oil back-streaming. FTA-MS Molecular sieve insert for water vapor and to help
minimize oil backstreaming
They are placed in the
vacuum line between the
freeze dryer and the vacuum
pump.
14
SP Scientific Supports You in Ways Unrivaled in the Industry:
LyoLearn Webinars:
Free online seminar series featuring topics of interest to lyophilization scientists and
presented by industry experts. Live sessions allow participants to interact with renowned
freeze-drying specialists, such as Dr. John Carpenter, Dr. Steve Nail, Dr. Michael Pikal,
and other who’s who of the freeze drying community. Each online LyoLearn Session is
recorded and archived for future viewing.
Hands-On Training:
SP Scientific’s hands-on training courses offer attendees the chance to optimize their
learning experiences by using tangible applications in a controlled setting. Led by “go-to”
leaders in the lyophilization industry, these courses are a must for anyone getting started
in freeze drying or scientists looking for collaborative environment to share best practices,
ideas and theories.
Technical Briefs:
SP Scientific’s technical briefs are relevant papers covering in-demand topics. Available
in a variety of languages, titles include: The Relevance of Product Resistance in Primary
Drying, The Importance of Controlling Nucleation Temperature During the Freeze Step,
Case Studies in Diagnosing and Correcting Problematic Lyophilization Cycles and/or
Formulations, Basic Principles of Freeze Drying, and Basic Lyophilizer Maintenance Helps
to Assure Good Results.