B65a RRH2x40-4R (UHGC) Field Installation Guide

3MN-01909-0002-RJZZA, DN195022347, Issue 02, October 2017

Product photo Physical attributes

500 mm
(19.7 in)

276 mm 184.8 mm
(10.9 in) (7.3 in)
External interfaces Weight = 20.7 kg
Important! (bottom of RRH) (45.6 lbs)
The Nokia B65a RRH2x40-4R must be installed vertically oriented with cabling Notes:
interfaces at the top and bottom. Upside down and horizontal mounting are not
1. All specifications are with the mounting bracket installed.
allowed.
2. Dimensions do not include connectors or other small protrusions.
The B65a RRH2x40-4R may also be referred to as UHGC.

Intended audience
This document is intended for field construction personnel during the installation of hardware for Nokia customers. This product must only be installed
by a Qualified Person (a person designated by the employer; and by reason of training, experience, or instruction has demonstrated the ability to
perform safely all assigned duties; and, when required is properly licensed in accordance with federal, state, or local laws and regulations). Proper safety
polices and practices must be adhered to. Risks are discussed in more detail in the LTE B65a RRH2x40-4R - Site Preparation Guidelines (3MN-01909-
0001-RJZZA) and LTE Remote Radio Head (RRH) - Safety Guidelines (3MN-01725-0002-RJZZA) documents available to Nokia customers at
http://support.alcatel-lucent.com/. No other use of this document is approved.
Legal notice
Nokia is a registered trademark of Nokia Corporation. Other products and company names mentioned herein may be trademarks or tradenames of their respective owners.
The information presented is subject to change without notice. No responsibility is assumed for inaccuracies contained herein.
© 2017 Nokia. All rights reserved.
Contains proprietary/trade secret information which is the property of Nokia and must not be made available to, or copied or used by anyone outside Nokia without its written authorization.
Not to be used or disclosed except in accordance with applicable agreements.
Required parts
Part No. 3JR10178AA Part No. 3JR58710AA

Description B65a RRH2x40-4R Description Small pole mounting kit

Qty. 1 Qty. 1

Comments Includes RRH with carrying Comments Optional: Required only for
handle small pole mounting

Part No. 3JR39511AA Part No. 3JR58711AA

Description Solar shield Description Large pole mounting kit

Qty. 1 Qty. 1
Comments Optional: 1 per RRH; includes Comments Optional: Required only for large
fasteners pole mounting

Part No. 3JR10825AA Part No. 3JR57909AA

Description RRH mounting bracket Description Ground cable with simple lug,
16 mm² (6 AWG), 8 m

Qty. 1 Qty. 1

Comments 1 required per RRH; used for all Comments 1 required per RRH for
mounting methods protective earth (PE) ground

Part No. 3JR30068AA Part No. 1AB428730002

Description RRH 4*Tx/Rx basic installation Includes cable ties, wire ferrules, Description 7/16 DIN 10 W load terminator
kit 2-hole lugs, heat shrink material,
waterproof tape, vinyl electrical
Qty. 1 tape, and cable labels Qty. 2 or 0 (optional)

Comments 1 required per three RRHs Comments Required for unused RF ports

Part No. 3JR58716AA

Description Wall mounting kit

Qty. 1

Comments Optional: Used only for wall


mounting, when desired, to
ease installation

B65a RRH2x40-4R (UHGC) Nokia – Proprietary – Use pursuant to applicable agreements 3MN-01909-0002-RJZZA Issue 02 October 2017 Page 2 of 18
Required parts (continued)
Part No. 1AB416150001 Part No. Part number depends on length
required and connector type

Description SFP transceiver, SMDF, Rate 3 Description RF cable, coax, 7/16 DIN male
to 7, 1310 nm, 14 km, LC conn. Includes coaxial cable with 7/16
DIN male connectors
Qty. 1 Qty. 2 or 4
Comments 1 required per CPRI connection Comments 1 required for each antenna
connection used

Part No. Part number depends on length Part No. Part number depends on length

Description Optical fiber, SMDF, LC-LC Description User alarm cable, 4 pair, circular
connectors DIN male on one end
Qty. 1 Qty. 1 (optional)
Comments 1 required per CPRI connection Comments Required for user alarms

Part No. 1AB027220001 Part No. Part number depends on length

Description R2CT weatherized plug Description AISG cable, 8-pin circular DIN
Qty. 1 Qty. 1 (optional)
Comments 1 required per CPRI connection Comments Required for AISG daisy chain
connection

Part No. 1AB272210001 Part No. 3JR80394AA

Description Cable adaptor assembly kit, Description Cable adaptor assembly kit,
2x6 mm² to 2x10 mm² 2x6 mm² to 2x16 mm²
Qty. 1 (optional) Qty. 1 (optional)

Comments 1 required per RRH for use with Comments 1 required per RRH for use with
3BK50119AB only 1AC05801001 only

Part No. Mutually exclusive part number depends on 3BK50201AA = 2x4 mm² (12 AWG), 250 m roll, used for length > 0 m
length required and conductor size and ≤ 28 m
3BK50113AC = 2x6 mm² (10 AWG), 250 m roll, used for length
Description Power cable, 250 m roll or ordered to length
> 28 m and ≤ 56 m
Qty. 1 3BK50119AB = 2x10 mm² (8 AWG), 250 m roll, used for length > 56 m
and ≤ 93 m
Comments 250 m roll = 1 required per multiple RRHs;
ordered to length = 1 per RRH 1AC05801001 = 2x16 mm² (6 AWG), ordered to length, used for
length > 93 m and ≤ 153 m

B65a RRH2x40-4R (UHGC) Nokia – Proprietary – Use pursuant to applicable agreements 3MN-01909-0002-RJZZA Issue 02 October 2017 Page 3 of 18
External interfaces

Top view Bottom view


Important!
Connect CPRI₋PRI
Wall or pole side port to LTE BBU Wall or pole side

CPRI₋PRI

GND

Rx4 TxRx2 TxRx1 Rx3

Note: The TxRx1 and TxRx2 ports each include


an integrated (internal) bias tee.

CPRI₋SEC STATUS ALD ALM -48V IN


LED

Note: Solar shield and wall mounting bracket not shown in these views

Attention: For all product-specific figures in this document, the colors depicted are for identification purposes only. Final product colors may be different.
B65a RRH2x40-4R (UHGC) Nokia – Proprietary – Use pursuant to applicable agreements 3MN-01909-0002-RJZZA Issue 02 October 2017 Page 4 of 18
1: Unpack RRH & prepare for installation
Required materials

Part No. Description Qty.

3JR10178AA B65a RRH2x40-4R 1

Important! The remote radio head (RRH) must be 3JR10825AA RRH mounting bracket 1

handled with care during unpacking and staging. 3JR39511AA Solar shield (optional) 1

1AB416150001 SFP transceiver, SMDF, Rate 3 to 7, 1310 nm, 14 km, LC connector 1

1 Open shipping box and carefully roll RRH onto left (See note 1)

side to expose carrying handle. Note:


1. Only use SFPs ordered from Nokia.

Carrying handle

4 Attach the RRH mounting bracket to the RRH


using the M8 fasteners provided with the RRH.

RRH
Hoisting
mounting
points
bracket

Important! The handle is for hand-carrying


only. Do not use for hoisting!

Top of
2 Carefully lift RRH out of box.
RRH
Bottom view

3 Insert fiber optic


Protective foam or padding

SFP into CPRI₋PRI


port before hoisting Important! The RRH mounting bracket
and reinstall must be attached to the RRH before it can
protective cap. be hoisted.

M8 torque: 23 N·m (17 lbf-ft)


B65a RRH2x40-4R (UHGC) Nokia – Proprietary – Use pursuant to applicable agreements 3MN-01909-0002-RJZZA Issue 02 October 2017 Page 5 of 18
1: Unpack RRH & prepare for installation (continued)

5 If the solar shield is required, attach the solar


shield to the RRH using the M5 fasteners
provided with the solar shield.

RRH solar
shield

Bottom
of RRH

Protective foam or padding

M5 torque: 4 N·m (3 lbf-ft)


B65a RRH2x40-4R (UHGC) Nokia – Proprietary – Use pursuant to applicable agreements 3MN-01909-0002-RJZZA Issue 02 October 2017 Page 6 of 18
Safety statements for installation procedures
Note: For the complete set of product safety statements, see LTE Remote Radio Head (RRH) - Safety Guidelines, 3MN-01725-
0002-RJZZA, available at http://support.alcatel-lucent.com/.

DANGER
Electric shock hazard
Working in severe weather can result in personal injury or death and damage to the equipment.
Never install or perform maintenance during severe weather (high winds, lightning, blizzards, hurricane etc.).

WARNING
Falling-object hazard
If the B65a RRH2x40-4R falls while being lifted, it can result in personal injury or death and damage to the equipment.
Keep the area beneath the B65a RRH2x40-4R and the immediate surrounding area completely clear of personnel,
equipment, vehicles, etc. at all times during the lifting and moving operation.

WARNING
Overhead-load hazard
Hoisting points and apparatus can break, severely damaging the B65a RRH2x40-4R when it is being lifted to its final
mounting position.
Ensure that all hoisting points and lifting apparatus are defect free and properly attached before lifting the B65a
RRH2x40-4R.

WARNING
Fall hazard
Falls can occur when working at heights resulting in serious personal injury or death.
To prevent a fall when working at heights (ladder, scaffold, manlift, roof, etc.) follow safe work practices and wear
appropriate fall protection equipment.
B65a RRH2x40-4R (UHGC) Nokia – Proprietary – Use pursuant to applicable agreements 3MN-01909-0002-RJZZA Issue 02 October 2017 Page 7 of 18
Safety statements for installation procedures (continued)
Note: For the complete set of product safety statements, see LTE Remote Radio Head (RRH) - Safety Guidelines, 3MN-01725-
0002-RJZZA, available at http://support.alcatel-lucent.com/.

CAUTION
Lifting hazard
Lifting this equipment by yourself can result in injury due to the size and weight of the equipment.
Always use at least two people or a lifting device to move or position this equipment.

CAUTION
Laceration hazard
The mounting bracket components may have sharp edges and burrs and contact may cause cuts and lacerations.
Beware of sharp edges and burrs, especially when manually transporting or hoisting the B65a RRH2x40-4R.
Wear appropriate personal protective equipment.

CAUTION
RF hazard
RF exposure in excess of applicable limits can result in personal injury.
The B65a RRH2x40-4Rs are designed and installed in order that they are compliant with the exposure guidelines laid
down by 47 CFR 1.1307 to 1.1310.
For all staff that are required to work in close proximity to the equipment, for example maintenance personnel, contact
with the antenna should be avoided. No such persons shall stay in front of the operating product’s antenna at a
distance of less than 1.7 m and 0.6 m on each side of the antenna.
No other persons shall stay in front of the operating product’s antenna at a distance of less than 4.1 m and 1.6 m on
each side of the antenna.
Workers equipped with personal medical electronic devices, such as pacemakers and hearing aids, shall consult the
manufacturer's instructions and consult their occupational health practitioner.

B65a RRH2x40-4R (UHGC) Nokia – Proprietary – Use pursuant to applicable agreements 3MN-01909-0002-RJZZA Issue 02 October 2017 Page 8 of 18
2: Install RRH on a wall
Required materials

Part No. Description Qty.

3JR10178AA B65a RRH2x40-4R 1

3JR10825AA RRH mounting bracket 1


Important! Ensure the wall is of adequate structural integrity
to support the total load of all RRHs mounted on the wall. 3JR58716AA Wall mounting kit (optional) 1

RRH
RRH mounting
bracket
1 If necessary, attach
RRH mounting
bracket to RRH
using M8 fasteners Pole mounting
provided with RRH. bracket

Note: If not using optional


wall mounting kit, attach M8
screws
RRH mounting bracket to
wall using M10 wall anchors
(customer provided). Then
install RRH on RRH
mounting bracket using M8 M12
fasteners provided with screws Expansion
RRH. plugs
M8
screws 2 Attach pole mounting bracket
M8 to wall using steel expansion
screws plugs and M12 screws, plain,
and lock washers.
3 Install RRH on pole
mounting bracket
using M8 screws.
M8 torque: 23 N·m (17 lbf-ft)
M12 torque: 50 N·m (37 lbf-ft)
B65a RRH2x40-4R (UHGC) Nokia – Proprietary – Use pursuant to applicable agreements 3MN-01909-0002-RJZZA Issue 02 October 2017 Page 9 of 18
3: Install RRH on a small pole
Required materials

Part No. Description Qty.

3JR10178AA B65a RRH2x40-4R 1

3JR10825AA RRH mounting bracket 1


Note: The small pole mounting kit (3JR58710AA) is for
“standard” type poles, 50 mm to 152 mm diameter. 3JR58710AA Small pole mounting kit 1

RRH
RRH mounting
bracket

1 If necessary, attach
RRH mounting
bracket to RRH 2 Attach pole
using M8 fasteners mounting
provided with RRH. brackets to pole.

M8
screws

M12 bolt
hardware

M8
screws

3 Install RRH on pole


mounting bracket
using M8 screws.
M8 torque: 23 N·m (17 lbf-ft)
M12 torque: 50 N·m (37 lbf-ft)
B65a RRH2x40-4R (UHGC) Nokia – Proprietary – Use pursuant to applicable agreements 3MN-01909-0002-RJZZA Issue 02 October 2017 Page 10 of 18
4: Install RRH on a large pole
Required materials

Part No. Description Qty.

3JR10178AA B65a RRH2x40-4R 1

3JR10825AA RRH mounting bracket 1


Note: The large pole mounting kit (3JR58711AA) is for
“utility” type poles, 152 mm to 380 mm diameter. 3JR58711AA Large pole mounting kit 1

RRH
RRH mounting
bracket

1 If necessary, attach
RRH mounting
bracket to RRH 2 Attach pole
using M8 fasteners mounting
provided with RRH. bracket to pole.

M8
screws
Band clamps

M8
screws

3 Install RRH on pole


mounting bracket
using M8 screws.

M8 torque: 23 N·m (17 lbf-ft)


B65a RRH2x40-4R (UHGC) Nokia – Proprietary – Use pursuant to applicable agreements 3MN-01909-0002-RJZZA Issue 02 October 2017 Page 11 of 18
5: Connect protective earth (PE) ground
Required materials

Part No. Description Qty.

3JR30068AA RRH 4*Tx/Rx basic installation kit 1

1 Crimp 16 mm2 (6 AWG) two-hole lug (from the 3JR57909AA Ground cable with simple lug 1

RRH basic installation kit) onto end of ground


cable. Clean the contact surface area and use
antioxidant to prevent oxidation.
Right side view
2 Connect ground lug to RRH using M6 bolts, plain,
and lock washers.
M6 ground
points
Bottom view
Wall or pole side

Connect to
ground system

Front side Wall or


pole side
M6 ground
points

Connect to Front side


ground
system Note: Ground connection can be made to either of
the two possible ground locations on the RRH.

M6 torque: 5.6 N·m (4.1 lbf-ft)


B65a RRH2x40-4R (UHGC) Nokia – Proprietary – Use pursuant to applicable agreements 3MN-01909-0002-RJZZA Issue 02 October 2017 Page 12 of 18
6: Connect optical fiber cable
Required materials

Part No. Description Qty.

1AB416150001 SFP transceiver, SMDF, Rate 3 to 7, 1310 nm, 1


14 km, LC connector
Note: The bend radius limit for fiber optic cable is See note 1 Optical fiber, SMDF, LC-LC connectors 1
82.5 mm (3.25 inches). This bend radius limit must not
1AB027220001 R2CT weatherized plug 1
be exceeded when installing the fiber optic cables.
Notes:
1. Depends on length

Bottom view Wall or pole side

DANGER
Laser hazard
This equipment operates with invisible laser radiation. Laser
radiation can cause considerable injuries to the eyes.
Never look into the end of an exposed fiber or into an open
optical connector when the optical source is switched on.
CPRI₋PRI

Always observe the laser warning instructions.

NOTICE
Protect fiber cable
1 If necessary, insert SFP into CPRI₋PRI Mishandling fiber optic cable can result in damaged and non-
port and lock into place. functioning cables.
The optical cable is very sensitive, take the maximum
Note: Clean and inspect the LC connectors precaution when installing it. The optical fiber should be
on the CPRI fiber optic cable before protected in solid pipe. Do not use cable ties on the fiber
connecting to SFP. cable. Do not cut this cable on site, excess length should be
R2CT coupling nut coiled inside the eNodeB. The fiber optic connector should be
protected by a cap when not being used. Respect the bending
2 Use assembly instructions provided with R2CT radius during the manipulation of optical cable (82.5 mm).
weatherized plug to assemble R2CT plug onto
optical fiber and connect to CPRI₋PRI port. See LTE Remote Radio Head (RRH) - Safety Guidelines, 3MN-01725-
0002-RJZZA, available at http://support.alcatel-lucent.com/.

B65a RRH2x40-4R (UHGC) Nokia – Proprietary – Use pursuant to applicable agreements 3MN-01909-0002-RJZZA Issue 02 October 2017 Page 13 of 18
7: Connect user alarm & AISG cables
Required materials

Part No. Description Qty.


(optional) Depends on length User alarm cable, 4 pair, circular DIN male on one end 1

Depends on length AISG connection cable, 8-pin circular DIN 1

Bottom view Alarm connector pin assignments


Wall or pole side
Pin Wire ALARM port
color designation
Alarm & AISG 1 WH/BR User_ALM_4_P
connector pin
2 GR User_ALM_3_RTN
configuration
3 WH/BL User_ALM_1_P Legend:

4 OR User_ALM_2_RTN BL = Blue

5 WH/OR User_ALM_2_P BR = Brown


ALM 6 BR User_ALM_4_RTN GR = Green

7 WH/GR User_ALM_3_P OR - Orange


ALD

8 BL User_ALM_1_RTN WH = White

1 Connect AISG cable AISG connector pin assignments


to RRH ALD port. Pin Designation
Note: AISG output 1 N/C
port has female pins. 2 N/C
3 RS485 B
3 Connect alarm cable
2 Connect AISG cable to distribution frame. 4 N/C
to AISG input port of
5 RS485 A
another antenna line 4 Connect alarm cable to
device (ALD). RRH ALM port. 6 +10 V to +30 V DC output
7 DC return
8 N/C

B65a RRH2x40-4R (UHGC) Nokia – Proprietary – Use pursuant to applicable agreements 3MN-01909-0002-RJZZA Issue 02 October 2017 Page 14 of 18
8: Connect RF cables
Required materials

Part No. Description Qty.

See note 1 RF cable, coax, 7/16 DIN male 2 or 4

3JR30068AA RRH 4*Tx/Rx basic installation kit 1


Note: Connect TxRx1 and TxRx2 before Rx3 and Rx4.
1AB428730002 7/16 DIN 10 W load terminator (See note 2) 2 or 0

Notes:
Top view Wall or pole side
1. Depends on length and connector type
2. Required for unused RF ports

Supported RF configurations
TxRx2

TxRx1
Configuration Antenna connections
Rx4

Rx3
2T2R TxRx1, TxRx2
2T4R TxRx1, TxRx2, Rx3, Rx4

Front
side 1 If required, attach 7/16 DIN connector to each RF cable.
OR OR
RF RF
2 Connect RF cables to RF ports.
cable RF load cable RF load Note: The TxRx1 and TxRx2 ports each include an
terminator terminator
integrated (internal) bias tee.

3 Apply weatherproofing according to local convention.

4 Install 7/16 DIN 10 W load terminator on each unused


RF port.

7/16 DIN connector torque: 25 N·m (18.4 lbf-ft)


7/16 DIN 10 W load terminator torque: 20 N·m (14.8 lbf-ft)
B65a RRH2x40-4R (UHGC) Nokia – Proprietary – Use pursuant to applicable agreements 3MN-01909-0002-RJZZA Issue 02 October 2017 Page 15 of 18
9: Identify power cable size and need for cable adaptor
Note: The maximum cable length between the RRH and DC power supply is defined by the conductor size. Four types of
power cables are available: 2x4 mm², 2x6 mm², 2x10 mm², and 2x16 mm². The 2x10 mm² and 2x16 mm² sizes must use
a cable adaptor to be connected to the RRH . The RRH DC connector cannot support DC cables greater than 2x6 mm².
Power cables and cable adaptors
Part No. Description Comments
3BK50201AA Power cable, 2x4 mm² (12 AWG), 250 m roll Used for length > 0 m and ≤ 28 m, no cable adaptor required
3BK50113AC Power cable, 2x6 mm² (10 AWG), 250 m roll Used for length > 28 m and ≤ 56 m, no cable adaptor required
3BK50119AB Power cable, 2x10 mm² (8 AWG), 250 m roll Used for length > 56 m and ≤ 93 m, requires 1AB272210001 cable adapter
1AC05801001 Power cable, 2x16 mm² (6 AWG), ordered to length Used for length > 93 m and ≤ 153 m, requires 3JR80394AA cable adapter
1AB272210001 Cable adaptor assembly kit, 2x6 mm² to 2x10 mm² Required for use with 3BK50119AB only
3JR80394AA Cable adaptor assembly kit, 2x6 mm² to 2x16 mm² Required for use with 1AC05801001 only
1AB272210001

1 Determine installed power cable size based on power cable


part number and conductor size.

2 If 3BK50201AA or 3BK50113AC power cable is used, To RRH 1 2 3 4


proceed to procedure 10. Connect DC power cable. 3JR80394AA

3 If 3BK50119AB or 1AC05801001 power cable is used, attach


required cable adaptor to RRH end of power cable.
Important! Smaller heat shrink tubing must be installed over
splice connectors after splice connections are made. Legend:
1. Jacketed cable, 2x6 mm² (10 AWG), with splice
Larger heat shrink tubing must be installed over jacketed cable to connectors attached
completely cover splice connections and individual conductors. 2. Splice connectors
The cable adaptor assembly must be installed close the RRH to 3. Heat shrink tubing, 19.0 mm (.75 in) ID
allow connection of 2x6 mm² (10 AWG) conductors to RRH. 4. Heat shrink tubing, 50.8 mm (2.00 in) ID

B65a RRH2x40-4R (UHGC) Nokia – Proprietary – Use pursuant to applicable agreements 3MN-01909-0002-RJZZA Issue 02 October 2017 Page 16 of 18
10: Connect DC power cable
Required materials

Part No. Description Qty.

Depends on length required and conductor size Power cable 1

Depends on power cable size Cable adaptor assembly kit 0 or 1


DANGER
Note: See procedure 9: Identify power cable size and need for cable adaptor for
Electric shock hazard cable adaptor assembly kit installation information.

Contact with energized network element power supply


Bottom view
lines can result in serious personal injury.
Ensure that the DC power is OFF and secured against
turn-on before completing this procedure.
See LTE Remote Radio Head (RRH) - Safety Guidelines, 3MN-
01725-0002-RJZZA, available at http://support.alcatel-lucent.com/.

1 Open access door on conduit box and loosen cable


clamp inside conduit box.

2 Remove M25 cap and sealing insert from cable gland.

−48V IN
3 Route DC power cable through M25 cap, sealing insert, Conduit box with External view
and cable gland to DC terminal block inside conduit box. access door open when complete

4 Cut DC power cable to length and strip ends of wires.

5 Refer to connection label inside conduit box and connect wires


to DC terminal block.
• -48 V DC supply to -48V
• 0 V (-48 V return) to RTN IN

6 Assemble sealing insert and M25 cap into cable gland and tighten.
Ensure sealing insert and connected DC wires do not twist.

7 Secure cable clamp inside conduit box. Close the access door and M5 torque: 4 N·m (3 lbf-ft)
tighten M5 securing screws. M25 cap torque (max): 15 N·m (11 lbf-ft)
B65a RRH2x40-4R (UHGC) Nokia – Proprietary – Use pursuant to applicable agreements 3MN-01909-0002-RJZZA Issue 02 October 2017 Page 17 of 18
General status LED states

General status LED states after power up

LED state Status Description

Off LED disabled or no power supplied LED is disabled in software or no DC power to RRH

Solid red Initial power on RRH is initializing (if just powered on or reset)

Non-recoverable critical failure A critical hardware failure prevents the transmit and/or active receive paths from functioning

Non-critical non-recoverable failure Non-critical fault (other than antenna) detected, fault is not recoverable, RF transmission is still ON

Flashing red Recoverable critical failure RRH not currently operational due to hardware fault, but should recover (e.g., under-temperature
warm up, over-temperature critical shutdown)

External power supply failure A recoverable fault is detected and the external connections (power, antenna) should be checked
Non-critical recoverable failure Non-critical fault (other than antenna) detected, fault is recoverable, RF transmission is still ON

External antenna failure An equipped antenna has a VSWR fault

Flashing yellow Software download RRH is downloading software and RF transmission is OFF, but is currently operational

Solid yellow Slave CPRI link failure The slave CPRI link (CPRI1) has failed

Solid green Normal operation No critical failures or faults, transmitter is enabled.

Flashing green Standby No critical failures or faults, but the transmitter is disabled

Bottom view

Status LED

B65a RRH2x40-4R (UHGC) Nokia – Proprietary – Use pursuant to applicable agreements 3MN-01909-0002-RJZZA Issue 02 October 2017 Page 18 of 18