LTE B31 RRH2x40 (UHAA) Installation Manual

The  information  in  this  document  applies  solely  to  the  hardware/software  product  (“Product”)  specified
herein, and only as specified herein. Reference to “Nokia” later in this document shall mean the respective
company within Nokia Group of Companies with whom you have entered into the Agreement (as defined
below).

This document is intended for use by Nokia's customers (“You”) only, and it may not be used except for the
purposes  defined  in  the  agreement  between  You  and  Nokia  (“Agreement”)  under  which  this  document  is
distributed. No part of this document may be used, copied, reproduced, modified or transmitted in any form
or  means  without  the  prior  written  permission  of  Nokia.  If  You  have  not  entered  into  an  Agreement
applicable to the Product, or if that Agreement has expired or has been terminated, You may not use this
document in any manner and You are obliged to return it to Nokia and destroy or delete any copies thereof.

The  document  has  been  prepared  to  be  used  by  professional  and  properly  trained  personnel,  and  You
assume  full  responsibility  when  using  it.  Nokia  welcomes  your  comments  as  part  of  the  process  of
continuous development and improvement of the documentation.

This  document  and  its  contents  are  provided  as  a  convenience  to  You.  Any  information  or  statements
concerning the suitability, capacity, fitness for purpose or performance of the Product are given solely on
an  “as  is”  and  “as  available”  basis  in  this  document,  and  Nokia  reserves  the  right  to  change  any  such
information  and  statements  without  notice.  Nokia  has  made  all  reasonable  efforts  to  ensure  that  the
content  of  this  document  is  adequate  and  free  of  material  errors  and  omissions,  and  Nokia  will  correct
errors  that  You  identify  in  this  document.  Nokia's  total  liability  for  any  errors  in  the  document  is  strictly
limited to the correction of such error(s). Nokia does not warrant that the use of the software in the Product
will be uninterrupted or error-free.

NO  WARRANTY  OF  ANY  KIND,  EITHER  EXPRESS  OR  IMPLIED,  INCLUDING  BUT  NOT  LIMITED  TO
ANY  WARRANTY  OF  AVAILABILITY,  ACCURACY,  RELIABILITY,  TITLE,  NON-INFRINGEMENT,
MERCHANTABILITY  OR  FITNESS  FOR  A  PARTICULAR  PURPOSE,  IS  MADE  IN  RELATION  TO  THE
CONTENT  OF  THIS  DOCUMENT.  IN  NO  EVENT  WILL  NOKIA  BE  LIABLE  FOR  ANY  DAMAGES,
INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL
OR  ANY  LOSSES,  SUCH  AS  BUT  NOT  LIMITED  TO  LOSS  OF  PROFIT,  REVENUE,  BUSINESS
INTERRUPTION,  BUSINESS  OPPORTUNITY  OR  DATA  THAT  MAY  ARISE  FROM  THE  USE  OF  THIS
DOCUMENT  OR  THE  INFORMATION  IN  IT,  EVEN  IN  THE  CASE  OF  ERRORS  IN  OR  OMISSIONS
FROM THIS DOCUMENT OR ITS CONTENT.

This document is Nokia proprietary and confidential information, which may not be distributed or disclosed
to any third parties without the prior written consent of Nokia.

Nokia  is  a  registered  trademark  of  Nokia  Corporation.  Other  product  names  mentioned  in  this  document
may be trademarks of their respective owners.

Copyright © 2018 Nokia. All rights reserved.

f Important Notice on Product Safety


  This product may present safety risks due to laser, electricity, heat, and other sources of danger.

Only  trained  and  qualified  personnel  may  install,  operate,  maintain  or  otherwise  handle  this
product and only after having carefully read the safety information applicable to this product.

The  safety  information  is  provided  in  the  Safety  Information  section  in  the  “Legal,  Safety  and
Environmental Information” part of this document or documentation set.

Nokia is continually striving to reduce the adverse environmental effects of its products and services. We
would  like  to  encourage  you  as  our  customers  and  users  to  join  us  in  working  towards  a  cleaner,  safer
environment. Please recycle product packaging and follow the recommendations for power use and proper
disposal of our products and their components.

If you should have questions regarding our Environmental Policy or any of the environmental services we
offer, please contact us at Nokia for any additional information.

2 © 2018 Nokia DN09249151 Issue: 04
LTE B31 RRH2x40 (UHAA) Installation Manual

Table of Contents
This document has 121 pages
   
1 About this document...................................................................... 5
1.1 Reason for new issue.....................................................................5
1.2 Intended audience..........................................................................5
1.3 Safety labels...................................................................................6
1.4 How to use this document..............................................................6
1.5 Conventions used.......................................................................... 6
1.6 Systems supported........................................................................ 7
1.7 Related documentation.................................................................. 7
1.8 Related training.............................................................................. 8
1.9 Document support..........................................................................8
1.10 Technical support........................................................................... 9
1.11 How to order...................................................................................9
1.12 How to comment............................................................................ 9
   
2 Safety........................................................................................... 10
2.1 Safety .......................................................................................... 10
2.2 Safety - specific hazards.............................................................. 10
2.3 Product safety.............................................................................. 13
   
3 Product overview..........................................................................14
3.1 Functional description.................................................................. 14
3.2 RRH description........................................................................... 15
3.3 RRH weights and dimensions...................................................... 19
   
4 Site configurations........................................................................21
4.1 RF configurations......................................................................... 21
4.2 Common Public Radio Interface Configuration............................ 21
   
5 Tools, materials, and checklist..................................................... 23
5.1 Preparatory information................................................................23
5.1.1 Tools required for installation....................................................... 23
5.1.2 Torque requirements.................................................................... 25
5.1.3 Verify site preparation completed.................................................26
5.1.4 Physical installation process overview......................................... 27
5.1.5 Installation procedure checklist.................................................... 27
   
6 Transport, mount, and ground RRH............................................. 29
6.1 Pre-installation instructions.......................................................... 29
6.1.1 Transport and Mount the RRH..................................................... 29
6.1.1.1 Hoisting an RRH onto a tower......................................................30
6.1.1.2 Transport and Mount the RRH..................................................... 33
6.2 Mounting instructions................................................................... 34
6.2.1 To mount hardware to wall........................................................... 34

DN09249151 Issue: 04 © 2018 Nokia 3
LTE B31 RRH2x40 (UHAA) Installation Manual

6.2.1.1 Attach mounting bracket.............................................................. 37
6.2.1.2 Install RRH on main bracket........................................................ 39
6.2.2 Pole mount installation overview..................................................42
6.2.3 Installing the RRH on a small pole............................................... 43
6.2.3.1 Installing a Single RRH................................................................ 44
6.2.3.2 Installing two RRHs......................................................................49
6.2.3.3 Installing three or more RRHs......................................................56
6.2.4 Installing the RRH on a large pole............................................... 63
6.2.5 Installing the RRH on U-steel.......................................................66
6.2.6 Installing the RRH on Angle Steel................................................72
6.2.7 To ground the RRH...................................................................... 79
   
7 Connect interface and RRH cables..............................................83
7.1 Route and connect RF jumper cables..........................................86
7.1.1 Route and connect RF jumper cables to the RRH ...................... 87
7.1.2 Waterproofing a connector of the RF jumper............................... 88
7.2 Route and connect RRH AISG Multi-Wire Cable and AISG
Extension Cable(Optional)........................................................... 90
7.2.1 Route and connect an AISG multi-wire cable without AISG
extension cable............................................................................ 91
7.2.2 Route and connect an AISG multi-wire cable with AISG extension
cable.............................................................................................92
7.3 Route and connect RRH alarm cables.........................................94
7.4 Opening the Cover Plate of an RRH Cabling Cavity....................97
7.5 To route and connect an RRH power cable................................. 99
7.5.1 Route and connect DC power cables to the RRH......................101
7.5.2 Add a Tool-Less Female Connector (Pressfit Type) to the RRH
Power Cable on the RRH side................................................... 102
7.6 Route and connect CPRI optical fiber cables.............................104
7.7 Closing the Cover Plate of an RRH Cabling Cavity................... 107
   
8 Finish the installation and power on a RRH............................... 112
8.1 To check the RRH hardware installation and the power on status...
112
   
9 Appendix: Product conformance statements..............................114
9.1 European Union..........................................................................114
   
10 Appendix: Acronyms...................................................................118
10.1 Acronyms....................................................................................118

4 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual About this document

1 About this document


This document provides hardware installation instructions for the Nokia B31 RRH2x40.
Procedures are provided for RRH handling, mounting, grounding, powering, and cabling.
Attention: The B31 RRH2x40 (UHAA) is being discontinued with the last order date in
the fourth quarter of 2016 and the end of product support in the fourth quarter of 2021.
Contact your sales team with questions.

1.1 Reason for new issue


The major changes introduced in this issue of the document are described in the
following paragraphs.
Document changes from the previous software release
The document changes are shown in the following table.

Feature/enhancement Description Location

Documentation changes Editorial changes only entire document


Product life cycle change The B31 RRH2x40 (UHAA) is being About this document
discontinued.
Documentation changes Added the equivalent Nokia RRH entire document
name
Editorial changes made to reflect the
rebranding of Alcatel-Lucent to Nokia

Documentation changes Update for FID179659 Product capabilities


Documentation changes Final version delivery. entire document
Documentation changes Update for CR1589111 To route and connect an
RRH power cable
Documentation changes Update pole diameter for small pole Installing the RRH on a
small pole
Documentation changes Added large pole mounting Installing the RRH on a
large pole
Documentation changes Document structure adjustment, Reason for new issue
update “What's new”
Documentation changes Addressed comments entire document
B31 RRH2x40 Created the first issue and entire document
addressed comments

1.2 Intended audience


The audience for this document is Installation personnel.

DN09249151 Issue: 04 © 2018 Nokia 5
   

About this document LTE B31 RRH2x40 (UHAA) Installation Manual

1.3 Safety labels


The safety alert symbol is used on product labels and in this document to alert the user
to important safety instructions.

1.4 How to use this document


Prior to installing the RRH, the installer should be familiar with the safety precautions,
warnings, and product conformance statements. Required tools and materials
recommended for installation, and a process checklist, are listed in Chapter “Tools,
materials, and checklists” .
The RRH installation instructions begin with Chapter “Transport, mount, and ground the
RRH” which provides mounting instructions for the RRH. After it is mounted into position,
the RRH can be connected to the network in accordance with the instructions given in
Chapter “Connect interfaces” . This connection is made via fiber optic cables. In addition,
instructions for connecting user and power alarms are provided in this chapter. Next,
instructions to connect the RRH to its power source is given in Chapter “Finish the
installation” . The power source is DC power provided from an external power converter
or DC generator.

1.5 Conventions used


In this document, all parts are described as they are shipped. Metric parts are specified
in metric units. Non-metric parts are specified in non-metric units.
Lengths and other measurements are given in metric units, with non-metric units given
as equivalents for use in non-metric markets.
For manufactured parts, the following system of conventions is used:
• Metric sizes of nuts, bolts, flat washers, and lock washers are identified by an
uppercase letter M followed immediately by a size in millimeters (example: M10)
• American fractional sizes of nuts, bolts, anchor bolts, and washers are identified by a
number followed immediately by a double apostrophe (example: 3/8"). In the case of
lengths measured in feet, "2 feet" is used rather than "2'" so that the single
apostrophe is not overlooked.

The illustrations in this document do not contain all details and exceptions, but are rather
intended to highlight main points. Dimensions are usually shown in millimeters, with
inches in parenthesis. As an example, 680.0 (26.77) equals 680 millimeters or 26.77
inches.
Wire gauges are specified in metric units. Equivalent sizes in the American Wire Gauge
(AWG) system are given in the following table.
Standard cross-sections and wire diameter of round copper conductors

6 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual About this document

The following table is from CEI/IEC 60947-1:2004, Table 1, Standard cross-sections of
round copper conductors and approximate relationship between mm2 and AWG/kcmil
sizes for reference. Additional wire sizes are included in this document as appropriate for
the topic.

AWG/ kcmil size Equivalent Metrics (mm2 ) Nearest Standart Metric Size (mm2 )

24 0.205 0.2
22 0.324 0.35
20 0.519 0.5
18 0.823 1
16 0.31 1.5
14 2.08 2.5
12 3.31 4
10 5.26 6
8 8.37 10
6 13.3 16
4 21.15 25
2 33.62 35
0 (1/0) 53.49 50
00 (2/0) 67.43 70
000 (3/0) 85.01 95
0000 (4/0) 107.22 120

Naming conventions
In this document, the B31 RRH2x40 at times will be referred to as:
• B31 RRH2x40
• RRH
• UHAA

1.6 Systems supported


This document applies to B31 RRH2x40 indoor and outdoor cell sites.

1.7 Related documentation


The following documents are referenced in this document or include additional
information relevant to the RRH. Refer to LTE Radio Access Network - FDD Customer
Documentation Overview for the purpose of each document listed.

DN09249151 Issue: 04 © 2018 Nokia 7
   

About this document LTE B31 RRH2x40 (UHAA) Installation Manual

Nokia documents
The following documents may provide additional useful information:
• LTE B31 RRH2x40 (UHAA) - Technical Description
• LTE B31 RRH2x40 (UHAA) - Site Preparation Guidelines
• LTE TDD Remote Radio Head (RRH) - Technical Description
• Grounding and Lightning Protection Guidelines for Alcatel-Lucent Network Wireless
System Cell Sites

Other documents

• Standard for Installation of Lightning Protection Systems


• Recommended Practices on Surge Voltages in Low Voltage AC Power Circuits
• Generic Requirements for Electronic Equipment Cabinets, Telcordia.

1.8 Related training


Safety training in the following areas is required for personnel installing products and
associated equipment:
• Hazard Communication
• Lift Safety
• Hoist Safety
• Lock Out/Tag Out
• Accident/Incident Reporting.

Other related training is for:
• Integration into the cell site
• Operation, Administration, and Maintenance (OA&M)

1.9 Document support


For support in using this or any other Nokia (former Alcatel-Lucent) document, please
call one of the following telephone numbers.
From United States

• If you are using a landline, a cellular phone or VoIP, dial this number: 1-888-582-
3688

From other countries

• If you are using a cellular phone or VoIP, dial this number: +1-630-224-2485
• If you are using a landline (phone without a plus [+] character), replace the plus sign
with your country's exit code. Dial this number: Exit code for the country of origin: 1-
630-224-2485. See the country-specific exit codes listed  here.

8 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual About this document

These numbers apply for document support only. For details about product hardware,
software, and technical support, see the section "Technical support".

1.10 Technical support


For technical support, contact your local Nokia customer support team. See the  Nokia
Support web site ( http://networks.nokia.com/support) for contact information.

1.11 How to order


To order Nokia documents contact your local sales representative or use Nokia Online
Services (NOLS)  https://online.networks.nokia.com.

1.12 How to comment


To comment on this document, go to the  Online Comment Form 
(http://infodoc.alcatel-lucent.com/comments/) or e-mail your comments to the 
Comments Hotline  (comments@alcatel-lucent.com).

DN09249151 Issue: 04 © 2018 Nokia 9
   

Safety LTE B31 RRH2x40 (UHAA) Installation Manual

2 Safety
This chapter covers safety precautions.

2.1 Safety
General precautions for installation procedures

f WARNING!
– Read and understand all instructions.
– Follow all warnings and instructions marked on this product.
– Installation and maintenance procedures must be followed and performed by
trained personnel only.
– The equipment must be provided with a readily accessible disconnect device as
part of site preparation.
– Grounding and circuit continuity is vital for safe operation of the equipment. Never
operate the equipment with grounding/bonding conductor disconnected.
– Install only equipment identified in the product's installation manual. Use of other
equipment may result in an improper connection which could lead to fire or injury.
– Use caution when installing or modifying telecommunications lines.
– The product has multiple power inputs. Before servicing, Disconnect all inputs to
reduce the risk of energy hazards.
– For continued protection against risk of fire, all fuses used in this product must be
replaced only with fuses of the same type and rating.
– Never install telecommunications wiring during a lightning storm.
– Never install telecommunications connections in wet locations.
– Never touch uninsulated wiring or terminals carrying direct current or ringing
current, and never leave this wiring exposed. Protect and tape uninsulated wiring
and terminals to avoid risk of fire, electrical shock, and injury to personnel.
– Never spill liquids of any kind on the product.
– To reduce the risk of an electrical shock, do not disassemble the product. Opening
and removing covers and/or circuit boards may expose you to dangerous voltages
or other risks. Incorrect reassembly can cause electrical shock when the unit is
subsequently used.

2.2 Safety - specific hazards

f DANGER! electric-shock
Working in severe weather can result in personal injury or death and damage to the
equipment.
Never install or perform maintenance during severe weather (high winds, lightning,
blizzards, hurricane etc.).

10 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual Safety

f DANGER! noxious-substance
Use of unspecified cleaning agents can result in personal injury.
Use only specified cleaning agents. Never use flammable solvents.
Always ensure there is adequate ventilation in the work area and wear the appropriate
personal protective equipment.

f DANGER! laser
This equipment operates with invisible laser radiation. Laser radiation can cause
considerable injuries to the eyes.
Never look into the end of an exposed fiber or into an open optical connector when the
optical source is switched on. Always observe the laser warning instructions.

f WARNING! electric-shock
Some parts of all electrical installations are energized. Failure to observe this fact and
the safety warnings may lead to bodily injury and property damage.
For this reason, only trained and qualified personnel (electrical workers as defined in
IEC 60215 + A1 or EN 60215) may install or service the installation.

f WARNING! electric-shock
The power supply lines to the network element are energized. Contact with parts
carrying voltage can cause health problems, possibly including death, even hours after
the event.
Open and lockout the load disconnect switch in the distribution box to completely de-
energize the network element.

f WARNING! electric-shock
This product may be connected to an AC main power supply and may contain an
internal battery supply. Disconnecting one power source may not de-energize the
system, and can lead to serious injury.
Disconnect and lock out the AC main power supply, if present, and the internal battery
supply, if present, before servicing the equipment.

f WARNING! laser
The light from laser and high-radiance LED's may cause eye damage if absorbed by the
retina.
In the US consult ANSI Z136.2, in Europe consult IEC-60825 Safety of laser products,
for guidance on the safe use of optical fiber communication systems in the workplace.

DN09249151 Issue: 04 © 2018 Nokia 11
   

Safety LTE B31 RRH2x40 (UHAA) Installation Manual

w NOTICE:  Semiconductor devices can be damaged by electrostatic discharges.
The following rules must be complied with when handling any module containing
semiconductor components:
• Wear conductive or antistatic working clothes (for example, coat made of 100%
cotton).
• Wear the grounded wrist strap.
• Wear shoes with conductive soles on a conductive floor surface or conductive work
mat.
• Leave the modules in their original packaging until ready for use.
• Make sure there is no difference in potential between yourself, the workplace, and
the packaging before removing, unpacking, or packing a module.
• Hold the module only by the grip without touching the connection pins, tracks, or
components.
• Test or handle the module only with grounded tools on grounded equipment.
• Handle defective modules exactly like new ones to avoid causing further damage.

w NOTICE:  Sudden changes in the weather may lead to the formation of condensation
on components. Operating the unit when condensation moisture is present can destroy
the unit.
Units which show signs of condensation must be dried before installation.

f CAUTION! laceration
The RRH may have sharp edges and burrs and contact may cause cuts and
lacerations.
Wear appropriate personal protective equipment.

w NOTICE:  Tools left in the working area can cause short circuits during operation which
can lead to the destruction of units.
Make sure after finishing your work that no tools, testing equipment, flashlights, etc.,
have been left in or on the equipment.

w NOTICE:  Inadequate circulation of cooling air can cause some units to become too
warm. This can lead to operational impairment.
Cover all installation slots for unequipped units with blanking panels.

f CAUTION! hot-surface
Touching a hot heater may cause burns.
Do not touch the heaters.
Before touching the units wait until they have cooled down, wear safety gloves and
clothes.

w NOTICE:  Cleaning plastic containers and lids with abrasive and aggressive cleaning
agents may cause permanent damage.
Do not use solvents, paraffin, abrasive or aggressive cleaning fluids, abrasive or
aggressive antiseptic agents or abrasive or aggressive materials.

12 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual Safety

w NOTICE:  Cleaning with water or a high-pressure cleaner may damage the components
in the RRH.
The washing down of the equipment with water or a high-pressure cleaner is not
permitted.

f CAUTION! lifting
Lifting this equipment by yourself can result in injury due to the size and weight of the
equipment.
Always use at least three people or a lifting device to move or position this equipment.

2.3 Product safety


Equipment safety
Safety information for this equipment can be found on various Caution, Warning, Danger,
information labels or instructions affixed to or included with the RRH, its internal
assemblies or included within this document. Informational and cautionary labels may
appear near the item they address or may be grouped in a single location on the
equipment. Warnings are typically adjacent to the hazard that is noted on the label. The
instructions, cautions and warnings found on these labels must be understood and
observed by all personnel involved with the equipment installation and maintenance.

DN09249151 Issue: 04 © 2018 Nokia 13
   

Product overview LTE B31 RRH2x40 (UHAA) Installation Manual

3 Product overview
This chapter provides an overview of the B31 RRH2x40.

3.1 Functional description


General description
The B31 RRH2x40 product is the new generation of LTE cell site equipment.
The B31 RRH2x40 supports 3GPP bands 31 which uplink 452.5 ~ 457.5MHz and
downlink 462.5 ~ 467.5MH.
The B31 RRH2x40 consists of the high-speed interface unit, signal processing unit,
power amplifier, duplexer, extension ports, and power module.
The B31 RRH2x40 is a one cell self-contained radio module, including:
• The HW is able to support several carriers with instantaneous carrier Bandwidth up
to 5MHz into the dedicated frequency band.
• Two CPRI port
• One Power supply socket
• One Alarm monitoring port
• One Communication port for the RET antenna
• Six indicators for running status

g Note: The port for transmitting RET signals is determined by the software.

Product capabilities
The product capabilities in this release are:
• The nominal transmit power is up to 2x40W
• Supporting 2T2R configuration for one single sector
• Support for daisy chaining up to 3 RRHs in one chain
• Outdoor, -48 V DC (-38V up to -57V)
• Supporting -40°C/+50°C (with solar radiation of 1120 W/m2)
• RRH mounting
– wall
– pole
– U-steel
– Angle-steel

• Supporting two user alarms for each RRH
• Supporting the following CPRI Rates:
– CPRI Rate 3: 2,457.6 Mbit/sec
– CPRI Rate 5 : 4,915.2 Mbit/sec

• Star configurations or daisy chain

14 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual Product overview

3.2 RRH description


RRH front-view (external)
The following figure shows the front-view of the RRH.

Bottom view of the RRH


Bottom view of the RRH:

Rear view of the RRH


Rear view of the RRH:

DN09249151 Issue: 04 © 2018 Nokia 15
   

Product overview LTE B31 RRH2x40 (UHAA) Installation Manual

Cable interfaces
The following figure shows the ports on the RRH panels.

16 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual Product overview

Ports and indicators on the RRH panels

Item Silkscreen Remarks

(1) Ports in the RTN(+) Power supply socket


cabling cavity
NEG(-)
CPRI0 Optical/electrical port 0, connected to the BBU
CPRI1 Optical/electrical port 1, reserved
(2) Ports at the ANT_TX/RXA TX/RX port A, supporting RET signal transmission
bottom
ANT_TX/RXB TX/RX port B
EXT_ALM Alarm monitoring port used for monitoring one
RS485 signal and two dry contact signals

DN09249151 Issue: 04 © 2018 Nokia 17
   

Product overview LTE B31 RRH2x40 (UHAA) Installation Manual

Item Silkscreen Remarks

RET Communication port for the RET antenna,
supporting RET signal transmission
(3) Indicators RUN See RRH Indicators table
ALM
ACT
VSWR
CPRI0
CPRI1

g Note: The port for transmitting RET signals is determined by the software.

The following table describers the six indicators on the RRH :

Indicator Color Status Meaning

RUN Green Steady on There is power supply, but the module is faulty.


Steady off There is no power supply, or the module is faulty.
Blinking (on for The board is functioning properly.
1s and off for 1s)
Blinking (on for Software is being loaded to the module, or the
0.125s and off module is not started.
for 0.125s)
ALM Red Steady on Alarms are generated, and the module must be
replaced.
Blinking (on for Alarms are generated. The alarms may be caused
1s and off for 1s) by the faults on the related boards or ports.
Therefore, you need to locate the fault before
deciding whether to replace the module.
Steady off No alarm is generated.
ACT Green Steady on The module is running properly with TX channels
enabled or the software is being loaded without
RRH running.
Blinking (on for The module is running properly with TX channels
1s and off for 1s) disabled.
VSWR Red Steady off No Voltage Standing Wave Ratio (VSWR) alarm is
generated.
Blinking (on for VSWR alarms are generated on the ANT_TX/RXB
1s and off for 1s) port.
Steady on VSWR alarms are generated on the ANT_TX/RXA
port.

18 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual Product overview

Indicator Color Status Meaning

Blinking (on for VSWR alarms are generated on the ANT_TX/RXA
0.125s and off and ANT_TX/RXB ports.
for 0.125s)
CPRI0 Red or Steady green The CPRI link is functioning properly.
green
Steady red An optical module fails to transmit or receive signals
because the optical module is faulty or the fiber
optic cable is broken.
Blinking red (on The CPRI link is out of lock because of a failure in
for 1s and off for clock lock between two modes or mismatched data
1s) rates over CPRI ports.
Steady off The optical module cannot be detected, or the
optical module is powered off.
CPRI1 Red or Steady green The CPRI link is functioning properly.
green
Steady red An optical module fails to transmit or receive signals
because the optical module is faulty or the fiber
optic cable is broken.
Blinking red (on The CPRI link is out of lock because of a failure in
for 1s and off for clock lock between two modes or mismatched data
1s) rates over CPRI ports.
Steady off The optical module cannot be detected, or the
optical module is powered off.

3.3 RRH weights and dimensions


Weights and dimensions
This topic covers the RRH weights and dimensions.

Standard RRH weights and dimensions


The following table provides weights and dimensions for the B31 RRH2x40.

g Note: Dimensions do not include the handle, or outside connectors (for example: RF
ports).

RRH configuration Weight Volume Overall dimensions height x width x depth


kg (litres) mm

B31 RRH2x40 20 18 400 x 300 x 150 (Main body dimensions)
420 x 300 x 170 (Dimensions including front panel)

RRH Overall dimensions

DN09249151 Issue: 04 © 2018 Nokia 19
   

Product overview LTE B31 RRH2x40 (UHAA) Installation Manual

The following figure shows the overall dimensions of the RRH. The overall heights of the
RRH is measured from top to bottom, dimensions, not include the handle, connectors,
and any small protrusions:

20 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual Site configurations

4 Site configurations
This chapter provides configuration information for the RRH site.

4.1 RF configurations

The RF capacity is measured in sectors, carriers, and RF signal power. The RF capacity
determines what components appear in the RRH and what antenna connections are
required.

Physical RF connections
The base station can be connected to RRHs with the follow RF frequency.
• 450 MHz ( band31 )

The RRH accept connections for:
• The RF antenna cables with 7-16 DIN coaxial female connectors.
• The RF connectors are always female, then the cables used to interconnect the
equipments are male-male.

RF configurations
The following configurations are supported.

Configuration RF connectors (per sector) RF signal power per carrier (nominal)

450 MHz 2 transmit/receive paths maximum transmitting power 40W each

4.2 Common Public Radio Interface Configuration

The Common Public Radio Interface (CPRI) of the RRHs can be connected in two
different ways to the Base Band Unit:
• Star configuration
• Daisy chain configuration

Star configuration
The star configuration is used when the RRHs are being mounted far from each other,
but nearly equally spaced from the Base Band Unit.
This figure shows the star configuration:

DN09249151 Issue: 04 © 2018 Nokia 21
   

Site configurations LTE B31 RRH2x40 (UHAA) Installation Manual

Daisy chain configuration


The daisy chain configuration is used when the RRHs are being mounted close together
but far from the BBU (Base Band Unit).
This figure shows the typical daisy chain configuration:

Up to 3 RRH is allowed for a daisy chain.

22 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual Tools, materials, and checklist

5 Tools, materials, and checklist


This chapter provides general instructions for mounting, handling, and cabling.

5.1 Preparatory information


This section presents information and procedures that are relevant before the RRHs are
mounted and grounded.
Also included in this section is information for verifying that site preparation requirements
have been met so that installation of the product can begin properly.
Reference documents
Further information on the RRH clearances and anchor holes can also be found in the
LTE B31 RRH2x40 (UHAA) - Site Preparation Guidelines.
Refer to the site-specific layout information for details on where the equipment must be
positioned.
This document also contains all necessary information on how to mark the positions of
the anchor holes and how to drill them.

5.1.1 Tools required for installation


Overview
This section provides a master list of all tools, materials, and parts required during the
installation process.

Tools

f WARNING! electric-shock
If the installation is performed with energized DC circuits or with a battery backup
supply connected, an energy hazard exists.
Therefore, always use tools that are properly insulated.

The following is a master list, in alphabetical order, of all tools that may be utilized during
installation:
• Torque driver and No.2 Pozi-Drive bit (5Nm)
• 19mm adjustable torque spanner (1.0 and 1.5Nm)
• Torque Wrench (Capable of measuring 1, 1.5 and 5Nm) with 17 and 19mm
Hexagonal Sockets.
• 13mm sockets
• 13mm adjustable torque spanner or torque wrench and sockets (10 and 15Nm)
• Box cutter or equivalent, to open packaging
• Crimping tools 22-16 gauge, 10-4/0 gauge (5-120 mm2) for installation of terminal
lugs and c-taps (R-3695A)
• Drill and drill bits (for mounting RRHs on a wall)
• Ear protection gear

DN09249151 Issue: 04 © 2018 Nokia 23
   

Tools, materials, and checklist LTE B31 RRH2x40 (UHAA) Installation Manual

• Electrical conduit installation equipment and materials
• Electrical tape
• Fixed pulley
• A hoist capable of lifting and moving the RRH into final position
• Hammer, 16 oz. (.5 kg) for anchor installation
• Hammer drill (a φ12 bit)
• Heat gun for heat shrink
• Inner hexagon wrench
• Insulated gloves
• Insulated hand tools (for completing electrical connections)
• Ladder or work stand/stool
• Level (steel)
• Lifting sling
• Marker, to mark floor for lineup and drilling
• Measuring tape
• Nut driver set (decimal) with 10-inch extension
• Nut driver set (metric) with 250-mm extension
• Ohmmeter (Multimeter, volt/ohmmeter, or equivalent)
• Safety goggles or glasses (R-3055)
• Screwdrivers (power and manual), flat-blade, Phillips (M3 to M6)
• Silicone caulk
• Socket sets (decimal and metric) various drives, including 1/4" drive for security bit
• Stripping tool (for LDF4 antenna jumper cables) - part number 74Z-0-12-15 for Huber
Suhner connectors; part number ITE-7189 for Andrew connectors.
• Tools for preparing cables
• Torque screwdriver
• 16mm (0.63 in.) and 32 mm (1.26 in.) Torque wrench
• 18mm adjustable torque spanner or torque wrench and sockets (35--40Nm)
• Wire stripper
• Wire rope or chain slings, 7/16 inch (11 mm), 7 feet long (2 m), minimum (quantity: 2)
• Wrench - Adjustable, (3/4 in./20 mm) open-ended wrench (or set of fixed open-ended
wrenches)
• Wrench - Flare Nut or Box Wrench, 12 mm (1/2 in.) required to install seismic
anchors.

g Note: Some of the tools in the master list is useful in some cases, but would not be
used in all RRH installations.

Supplies needed
The following is a master list, in alphabetical order, of all supplies that are required during
installation of the RRHs.
• Antioxidant compound (provided)
• Lacing cord, waxed #50
• Red tape or tags - 145C or equivalent, for tagging of DC power cables
• Shims - for leveling the floor stand (provided with anchoring kit)

24 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual Tools, materials, and checklist

• Tape - Electrical tape
• Tape - Masking tape, for protecting open anchor holes; labels
• Tie wraps
• Twine
• Fibre optic cleaning tools.

Parts and/or kits needed


The following is a master list of all parts and kits that are required during installation of
the RRH.
• DC connectorized cable
• External user alarm interface kit
• Fiber optics connectorized cable
• RF antenna jumper cables
• Anchor kit - 12 mm expansion anchor kit
• Grounding kit
• R-ITE-6111 M8 eyebolts (2)
• Mounting bracket (wall, pole)

5.1.2 Torque requirements


Overview
This section provides mechanical torque requirements. Refer to the table below.

Torque requirements for mechanical connections


The table below identifies the torque requirements to be followed when making
mechanical connections.

Item Description Torque

Newton Inch
Meters Pounds

RF cable connections 25 221
M6 x 16-mm thread rolling screw 4 30
All other M6 fasteners (nuts, hex-head bolts, etc.) 4 30
All M5 fasteners (pan-head screws, Torx screws and hex nut, etc.) 4 30
All M4 fasteners (pan-head screws, hex nut, etc.) 1.5 14

Generic torque specifications for electrical connections

w The table below must not be used for spanner head self-tapping screws. It is to be used
exclusively for electrical connections. Refer to the previous table for mechanical
connections.

DN09249151 Issue: 04 © 2018 Nokia 25
   

Tools, materials, and checklist LTE B31 RRH2x40 (UHAA) Installation Manual

The table below identifies the torque requirements to be followed when making electrical
connections.

Metric SAE Torque - in.-lb. [or ft.-lb.] and (Nm)


Screw Screw
Size
Size
Wire Connections Head Tightened Nut Tightened

Slotted Hex or Slotted Hex or Slotted Hex or


Machine Socket Cap Machine Socket Cap Machine Socket Cap

M4 8-32 15 (1.7) 15 (1.7) 19 (2.1) 19 (2.1) 19 (2.1) 23 (2.6)


M5 10-24 21 (2.4) 21 (2.4) 27 (3.1) 27 (3.1) 27 (3.1) 33 (3.7)
M6 1/4-20 50 (5.6) 50 (5.6) 65 (7.3) 65 (7.3) 65 (7.3) 80 (9.0)
M8 5/16-18 - 100 (11.3) - 135 (15.3) 135 (15.3) 165 (18.6)
M10 3/8-16 - 180 (20.3) - 240 (27.1) 240 (27.1) 290 (32.8)
M12 1/2-13 - 280 (31.6) - 385 (43.5) 385 (43.5) 465 (52.5)
M14 1/2-13 - 500 (56.5) - 585 (66.1) 585 (66.1) 710 (80.2)
M16 5/8-11 - [71] (96.3) - [97] (131.5) [97] (131.5) [118] (160.0)
M20 3/4-10 - [125] (169.5) - [172] (233.2) [172] (233.2) [209] (283.4)

5.1.3 Verify site preparation completed


Overview
This topic describes what must be done to verify that the site preparation is complete so
that installation procedures can begin.
If some of the requirements are not met, the installer must do so now.

Verify site preparation


Before installation of the RRH can begin, site preparation should have been completed in
accordance with LTE B31 RRH2x40 (UHAA) - Site Preparation Guidelines.
This unit is typically installed in restricted access locations.
The following site preparation requirements must be met before the installation of the
RRH can begin:
• Adequate clearance must be provided for service access.
• DC electric service must be installed.
• User alarm facilities must be installed (If required).
• Grounding electrode system must be installed.
• RF and antenna runs must be installed.
• Surge Protection box for RRH must be installed (If required).
• Surge Protection for antennas must be installed (If required).

26 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual Tools, materials, and checklist

• Mounting bracket holes must be drilled.
• The environment must comply with limits listed under Environmental Requirements.
• Cable supports and racks must be installed.
• Conduits for user alarms, and power are provided.

5.1.4 Physical installation process overview


Overview
This topic delineates the steps involved in the installation of the RRH.

Installation process
Following are the high level steps of the installation process:
1. Verify site preparation is complete
2. Transport the RRH
3. Mount RRH
4. Ground RRH
5. Connect user alarm
6. Connect DC power cable
7. Connect RF cables
8. Initial start-up & system test
9. Connect fiber optics cable.
10. Final steps to finish installation.

5.1.5 Installation procedure checklist


Overview
The following is a procedure checklist.

Checklist installation procedure

Done N/A Task

Verify site preparation completed

Transport the RRH

Mounting instructions

Installing an RRH PGND Cable

Installing an RRH RF Jumper

Installing an RRH AISG Multi-Wire Cable and AISG Extension Cable (optional)

Installing an RRH Alarm Cable (optional)

DN09249151 Issue: 04 © 2018 Nokia 27
   

Tools, materials, and checklist LTE B31 RRH2x40 (UHAA) Installation Manual

Done N/A Task

Installing an RRH Power Cable

Installing a CPRI Fiber Optic Cable

Checking and final RRH hardware installation procedure

28 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual Transport, mount, and ground RRH

6 Transport, mount, and ground RRH


This chapter provides general instructions for anchor installation and RRH handling, as
well as RRH placement, anchoring, and grounding.

6.1 Pre-installation instructions


This section covers the:
• Instructions for transporting and placing the RRH.

6.1.1 Transport and Mount the RRH

f WARNING!
If the RRH falls while being lifted, it may injure or kill a person.
Take both of the following precautions:
– Use lifting shackles and lifting straps that can support the RRH if one shackle or
one lifting strap fails and three remain. If a separate rating for shear is not provided,
each shackle must be used at no more than 25% of its tension rating.
– Keep the area beneath the RRH and the immediate surrounding area completely
clear of personnel at all times during the lifting operation.

Overview

f CAUTION!
Verify that the insulation layers of all RRH cables are intact. If the insulation layers are
damaged or broken, water will penetrate into the cables, which may cause damages to
RRHs or human injury.
To protect the equipment and prevent damage to the equipment, you are advised to
keep the unpacked equipment and packing materials indoors, take photos of the
stocking environment, packing case or carton, packing materials, and any rusted or
eroded equipment, and then file the photos.

This topic includes the procedures and precautions for transporting and hoisting an RRH
and its mounting brackets onto a tower. On a tower, an RRH can be installed on a pole,
angle steel, or U-steel.

Unpack the RRH


This section describes how to unpack and check the delivered equipment to ensure that
all the materials are included and intact.
Use the following steps to unpack the RRH.
1. Make note of the "TIP N TELL" indicator on the package to see if the RRH was
mishandled or tipped during shipment.
2. Remove the bubble wrap.
3. Check the total number of articles in each case according to the packing list.
4. Check the exterior of the packing case.

DN09249151 Issue: 04 © 2018 Nokia 29
   

Transport, mount, and ground RRH LTE B31 RRH2x40 (UHAA) Installation Manual

5. Check the type and quantity of the equipment in the cases according to the packing
list.
6. Report damage as required.

g Note: When transporting, moving, or installing the equipment, components, or parts,
you must:
• Prevent them from colliding with doors, walls, shelves, or other objects
• Wear clean gloves, and avoid touching the equipment, components, or parts with
bare hands, sweat-soaked gloves, or dirty gloves
• After an RRH is unpacked, it must be powered on within 24 hours

6.1.1.1 Hoisting an RRH onto a tower


Purpose
Use the following procedure to hoist an RRH and its mounting brackets onto a tower
respectively.

w Before attempting to use derrick equipment, refer to Chapter 2, "Safety precautions for
handling equipment".

f When the RRH is used with an AC/DC power module, you need to install the AC/DC
power module onto the RRH before hoisting the RRH onto a tower. For details about
how to install an AC/DC power module onto the RRH, see Installing an AC/DC Power
Module onto an RRH.

• Do not stand the RRH upright because the RF ports cannot support the weight of
the RRH
• Place a foam pad or cardboard under the RRH to protect the RRH housing from
damage during the installation

Before you start


For each cell site, the shipping company, installer, or installation supervisor must plan
which methods to use based on:
• How the equipment is delivered
• The dimensions and weights of the equipment
• The access route to the position where the equipment will be installed

The RRHs typically arrive at the site by truck. This topic assumes that:
• Each RRH is on a pallet (or equivalent)
• The packaging has been removed.

30 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual Transport, mount, and ground RRH

Procedure

1 After climbing up to the tower, technician A secures the fixed pulley to the tower platform
support and leads the lifting sling through the fixed pulley.

f WARNING! slip
Personnel injury or equipment damage
When moving the RRH, use appropriate lifting devices and sufficient number of
personnel.

w Hoist mounting brackets onto the tower and then install the mounting brackets before
hoisting the RRH onto the tower. When hoisting the mounting brackets and RRH,
protect them from colliding with the tower..

2 Uses the lifting sling to bind the mounting bracket for the RRH, as shown:

f The load-bearing capacity of each sling must be greater than 200 kg (441 lb) and the
diameter of each sling must be less than 25 mm (0.98 in.).

DN09249151 Issue: 04 © 2018 Nokia 31
   

Transport, mount, and ground RRH LTE B31 RRH2x40 (UHAA) Installation Manual

3 Uses the lifting sling and traction sling to bind the RRH, as shown:

g Note: Do not hoist the RRH by the handle or traction eye only, the following incorrect
binding method as shown:

32 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual Transport, mount, and ground RRH

4 Technician B pulls the lifting sling downwards, and technician C pulls the traction sling
outwards to protect the RRH from colliding with the tower.

f When hoisting the RRH onto a tower, protect them from colliding with the tower and
ground.

g Note: The procedure for hoisting the RRH and its mounting brackets onto the tower is
for your reference only.

6.1.1.2 Transport and Mount the RRH


Purpose
Proceed as follows to transport the RRH.

Before you start


For each cell site, the shipping company, installer, or installation supervisor must plan
which methods to use based on:
• How the equipment is delivered

DN09249151 Issue: 04 © 2018 Nokia 33
   

Transport, mount, and ground RRH LTE B31 RRH2x40 (UHAA) Installation Manual

• The dimensions and weights of the equipment
• The access route to the position where the equipment will be installed

The RRHs typically arrive at the site by truck. This topic assumes that:
• Each RRH is on a pallet (or equivalent)
• The packaging has been removed.

Procedure

1 Carefully lift and transport the RRH to the installation position.

2 Installation engineer A catches the RRH, install the RRH on the main bracket, use an
inner hexagon screwdriver wrench to tighten the captive screw into the hole of the
attachment plate to 5 N•m (44.25 lb-in.) .

3 Set the RRH down at or near the installation position, depending on the type of mounting
method is to be used.

4 Remove the lifting sling and traction sling.

5 Determine if the RRH is being installed against on a pole or an steel.

6.2 Mounting instructions


This sections contains instructions for the various methods of mounting the RRH.

6.2.1 To mount hardware to wall


Overview
This section describes the procedures to be followed when installing the mounting
hardware for the RRH on a solid concrete wall .

Wall mount brackets

f WARNING!
Before any hardware installation occurs, carefully read the section:
"Safety precautions for handling and mounting"

34 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual Transport, mount, and ground RRH

w Various building materials and construction methods dictate that the RRH be fastened
to the wall with appropriate mounting hardware. It is the responsibility of the customer to
provide any necessary support material and structures to ensure that the installation will
be in compliance with Building Officials and Code Administrators (BOCA), Uniform
Building Code (UBC), and all local codes.

The following figures illustrate the mounting bracket used to mount the RRH on a wall,
and also the hole patterns to fix it on the wall. The same bracket is used also in case of
pole mounting.

Disassemble the RRH mounting brackets
• Use an M6 inner hexagon torque screwdriver wrench to remove the four inner
hexagon screws on the pole installation bracket, and remove the main bracket from
the pole installation bracket
• Use an M10 torque wrench to loosen the nuts on the two square-neck bolts, and
remove the plastic cap, nuts, spring washers, flat washers, square-neck bolts, and
pole installation bracket from the auxiliary bracket

Wall mount - hole pattern


The following graphic shows the wall mounting hole pattern for the RRH. The dimension
shown are in millimeters. Place the installation bracket against the installation position,
use a level to verify that the pole installation bracket is placed horizontally, and then mark
anchor points with a marker.

DN09249151 Issue: 04 © 2018 Nokia 35
   

Transport, mount, and ground RRH LTE B31 RRH2x40 (UHAA) Installation Manual

g Note: It is recommended that the installation bracket be installed at a height of 1200
mm (47.24 in.) to 1600 mm (62.99 in.) above the ground.

Drill holes at the anchor points, and then insert expansion anchor bolt assemblies:

36 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual Transport, mount, and ground RRH

f Take proper safety measures to protect your eyes and respiratory tract against the dust
before drilling holes.

• Use a hammer drill with a Ф12 bit to drill holes vertically at the marked anchor points.
Ensure that the depth of each hole ranges from 55 mm (2.17 in.) to 60 mm (2.36 in.).
• Tighten the expansion anchor bolts slightly and place one vertically into each hole.
• Use a rubber mallet to pound the expansion anchor bolt until it goes all the way into
the hole.
• Tighten and then loosen the expansion bolt, and remove the M10 bolt, spring
washer, and flat washer in sequence.

g Note: After dismantling an expansion anchor bolt, ensure that the top of the expansion
tube is on the same level as the wall. Otherwise, the device cannot be installed on the
wall evenly and securely.

6.2.1.1 Attach mounting bracket


Before you start
Make sure you have read and understood the section.

DN09249151 Issue: 04 © 2018 Nokia 37
   

Transport, mount, and ground RRH LTE B31 RRH2x40 (UHAA) Installation Manual

Procedure

1 Install the pole installation bracket on the expansion anchor bolts, place the flat washers,
spring washers, and nuts through the expansion anchor bolts in sequence, and then use
a 16 mm (0.63 in.) torque socket to tighten the nuts to 30 N•m (21.2 lb-ft.).

Installing the pole installation bracket on the expansion anchor bolts:

g Note: Verify that the arrows on the pole installation bracket are pointing up.

38 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual Transport, mount, and ground RRH

2 Attach the main bracket onto the pole installation bracket, and use an inner hexagon
wrench to tighten four M6x16 inner hexagon screws to 5 N•m (44.25 lb-in.) so that the
main bracket and pole installation bracket are firmly secured.

Result
The RRH mounting bracket is attached to the wall.

6.2.1.2 Install RRH on main bracket


Purpose
Perform the following procedure to install the RRH on a main bracket.

f CAUTION!
The bolts on the RRH can pinch and damage your fingers.
Keep fingers clear when lowering the RRH into position.

Before you start


Make sure you have read and understood the section.

DN09249151 Issue: 04 © 2018 Nokia 39
   

Transport, mount, and ground RRH LTE B31 RRH2x40 (UHAA) Installation Manual

Procedure

1 Use an inner hexagon wrench to remove the attachment plate from one side of the RRH,
reinstall the attachment plate onto the rear of the RRH, and tighten the four stainless
screws to 5 N•m (44.25lb-in.)

Installing the attachment plate onto the rear of the RRH:

40 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual Transport, mount, and ground RRH

2 Install the RRH onto the main bracket:

f • Do not stand the RRH upright because the RF ports cannot support the weight of
the RRH.
• Place a foam pad or cardboard under the RRH to protect the RRH housing from
damage during the installation

3 Use an inner hexagon wrench to tighten the captive screw into the holes on the top of
the attachment plate and main bracket to 5 N•m (44.25lb-in.) so that the attachment plate
and main bracket are firmly secured.

Securing the captive screw into the connection hole:

DN09249151 Issue: 04 © 2018 Nokia 41
   

Transport, mount, and ground RRH LTE B31 RRH2x40 (UHAA) Installation Manual

6.2.2 Pole mount installation overview


Overview
This section describes the procedures to be followed when installing the RRH on a pole.
One or more RRHs can be installed on a pole.

Pole mounting brackets


The bracket assembly and the attachment plate for an RRH.
The following figures shows the bracket assembly for an RRH:

42 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual Transport, mount, and ground RRH

6.2.3 Installing the RRH on a small pole

f WARNING! fall
Falls can occur when working at heights resulting in serious personal injury or death.
To prevent a fall when working at heights (ladder, scaffold, manlift, roof etc.) follow safe
work practices and wear appropriate fall protection equipment.

This section describes the procedure and precautions for installing a single RRH ,two
RRH, three or more RRH on a small pole.
The figure shows the diameter of a pole:

DN09249151 Issue: 04 © 2018 Nokia 43
   

Transport, mount, and ground RRH LTE B31 RRH2x40 (UHAA) Installation Manual

6.2.3.1 Installing a Single RRH


Before you start
Before you install an RRH on a pole secured on a tower:
• The RRH and its mounting brackets are hoisted onto the tower.
• The hoist clamp on the main bracket is secured properly.

g Note:
• Do not stand the RRH upright because the RF ports cannot support the weight of
the RRH.
• Place a foam pad or cardboard under the RRH to protect the RRH housing from
damage during the installation.

Procedure

1 Determine a position for installing the mounting brackets.

• If the pole must be installed on a tower, determine a position for installing the
mounting brackets according to the instructions Clearance for a Single RRH in
3MN-00804-0001-RJZZA B31 RRH2x40 Site Preparation Guidelines.
• If the pole must be installed on the ground, determine a position for installing the
mounting brackets:

44 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual Transport, mount, and ground RRH

g Note: It is recommended that the mounting brackets be installed at a height of 1200
mm (47.24 in.) to 1600 mm (62.99 in.) above the ground.

DN09249151 Issue: 04 © 2018 Nokia 45
   

Transport, mount, and ground RRH LTE B31 RRH2x40 (UHAA) Installation Manual

2 Install the RRH mounting brackets, as shown:

Verify that the arrows on the mounting brackets are pointing up.
• Adjust the position of the nut and remove one end of the square-neck bolt from
the slot on the auxiliary bracket.
• Slide the mounting brackets onto the pole horizontally and insert the square-neck
bolt into the slot.

46 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual Transport, mount, and ground RRH

3 Use a 16 mm (0.63 in.) M10 torque wrench to tighten the nuts to 40 N•m (354.03 lbf•in)
so that the mounting brackets are secured onto the pole, as shown:

g Note: Tighten the nuts on the two square-neck bolts alternately. After the main and
auxiliary brackets are secured properly, measure the spacing between the brackets on
both sides and ensure that the spacing is the same on the two sides.

DN09249151 Issue: 04 © 2018 Nokia 47
   

Transport, mount, and ground RRH LTE B31 RRH2x40 (UHAA) Installation Manual

4 Install the RRH onto the main bracket, as shown:

5 Use an inner hexagon torque wrench to tighten the captive screw into the holes on the
top of the attachment plate and main bracket to 5 N•m (44.25 lb-in.) so that the
attachment plate and main bracket are firmly secured.

The figure shows securing the captive screw into the connection hole:

48 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual Transport, mount, and ground RRH

6.2.3.2 Installing two RRHs


Before you start
Before you install an RRH on a pole secured on a tower:
• The RRH and its mounting brackets are hoisted onto the tower.
• The hoist clamp on the main bracket is secured properly.

g Note:
• Do not stand the RRH upright because the RF ports cannot support the weight of
the RRH.
• Place a foam pad or cardboard under the RRH to protect the RRH housing from
damage during the installation.

Procedure

1 Install the first RRH onto the main bracket. For details, see Installing a Single RRH.

The figure shows installing the first RRH onto the main bracket:

DN09249151 Issue: 04 © 2018 Nokia 49
   

Transport, mount, and ground RRH LTE B31 RRH2x40 (UHAA) Installation Manual

50 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual Transport, mount, and ground RRH

2 Use an M6 inner hexagon wrench to remove the four inner hexagon screws from the
second set of mounting brackets, and remove the main bracket from the auxiliary
bracket,:

3 Install the removed main bracket on one side of the first main bracket.

Installing the second main bracket:

DN09249151 Issue: 04 © 2018 Nokia 51
   

Transport, mount, and ground RRH LTE B31 RRH2x40 (UHAA) Installation Manual

f The second main bracket must be installed with the opening ends of U-shaped slots on
both sides facing downwards.

Connect to the main mounting bracket for installing a common RRH:

52 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual Transport, mount, and ground RRH

g Note: The main mounting bracket for installing a 12 L blade RRH can connect to the
main mounting bracket for installing a common RRH.

DN09249151 Issue: 04 © 2018 Nokia 53
   

Transport, mount, and ground RRH LTE B31 RRH2x40 (UHAA) Installation Manual

4 Install the second RRH onto the main bracket, as shown:

After installing each RRH on its main bracket, use an inner hexagon torque wrench
to tighten the captive screw into the holes of the attachment plate and main bracket
to 5 N•m (44.25 lb-in.) so that the attachment plate and main bracket are firmly
secured.
Securing the captive screw into the connection hole:

54 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual Transport, mount, and ground RRH

DN09249151 Issue: 04 © 2018 Nokia 55
   

Transport, mount, and ground RRH LTE B31 RRH2x40 (UHAA) Installation Manual

5 Install the metal sheet for neighboring RRHs.:

• Use an M6 Phillips screwdriver to loosen the screw on the metal sheet farther
from the handle of the second RRH and remove the screw.
• Use an M6 Phillips screwdriver to loosen the screw on the metal sheet closer to
handle of the second RRH. Then rotate the metal sheet to align the vacant hole
in the metal sheet with a hole on the top of the first RRH.
• Insert the removed screw into the hole on the top of the first RRH and use an M6
torque screwdriver to tighten the screw to 5 N•m (44.25 lb-in.).

6.2.3.3 Installing three or more RRHs


Purpose
A pole supports the installation of three, four, or six RRHs. The procedures for installing
them are the same. Following is the procedure of installing four RRHs on a pole.

56 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual Transport, mount, and ground RRH

Before you start


Before you install an RRH on a pole secured on a tower:
• The RRH and its mounting brackets are hoisted onto the tower.
• The hoist clamp on the main bracket is secured properly.

g Note:
• Do not stand the RRH upright because the RF ports cannot support the weight of
the RRH.
• Place a foam pad or cardboard under the RRH to protect the RRH housing from
damage during the installation.

Procedure

1 Install the two RRHs onto the main bracket. For details, see Installing two RRHs.

The figure shows two RRHs installed on a pole:

DN09249151 Issue: 04 © 2018 Nokia 57
   

Transport, mount, and ground RRH LTE B31 RRH2x40 (UHAA) Installation Manual

2 Use an M6 inner hexagon wrench to remove the four inner hexagon screws from the
second set of mounting brackets, and remove the main bracket from the auxiliary
bracket.

3 Install the third main bracket and install the third RRH onto the third main bracket. Then
use an inner hexagon torque wrench to tighten the captive screw into the connection
holes on the top of the attachment plate and main bracket for the RRH, with a torque of 5
N•m (44.25 lb-in.).

Installing the third RRH onto the third main bracket:

58 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual Transport, mount, and ground RRH

f The third main bracket must be installed with the opening ends of U-shaped slots on
both sides facing downwards.

Connect to the main mounting bracket for installing a common RRH:

DN09249151 Issue: 04 © 2018 Nokia 59
   

Transport, mount, and ground RRH LTE B31 RRH2x40 (UHAA) Installation Manual

g Note: The main mounting bracket for installing a blade RRH can connect to the main
mounting bracket for installing a common RRH.

60 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual Transport, mount, and ground RRH

4 Install the metal sheet for neighboring RRHs.:

• Use an M6 Phillips screwdriver to loosen the screw on the metal sheet farther
from the handle of the second RRH and remove the screw.
• Use an M6 Phillips screwdriver to loosen the screw on the metal sheet closer to
handle of the first RRH. Then rotate the metal sheet to align the vacant hole in
the metal sheet with a hole on the top of the third RRH.
• Insert the removed screw into the hole on the top of the first RRH and use an M6
torque screwdriver to tighten the screw to 5 N•m (44.25 lb-in.).

5 Install the second set of RRH mounting brackets above or below the first set of RRH
mounting brackets and maintain a space equal to or greater than 80 mm (3.15 in.)
between the two sets of brackets.

Installing the second set of RRH mounting brackets:

DN09249151 Issue: 04 © 2018 Nokia 61
   

Transport, mount, and ground RRH LTE B31 RRH2x40 (UHAA) Installation Manual

g Note: When the diameter of a pole ranges from 60 mm (2.36 in.) to 76 mm (2.99 in.), a
maximum of three RRHs can be installed on the pole and the side-mounted installation
is recommended.

6 Install the fourth RRH onto the fourth main bracket, use an inner hexagon torque wrench
to tighten the captive screw into the holes of the attachment plate and main bracket to 5
N•m (44.25 lb-in.) so that the attachment plate and main bracket are firmly secured.

Installing the fourth RRH onto the fourth main bracket:

62 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual Transport, mount, and ground RRH

g Note: Only a pole whose diameter ranges from 76 mm (2.99 in.) to 120mm (4.72 in.)
supports more than three RRHs.

6.2.4 Installing the RRH on a large pole


Purpose

This section describes the procedures to be followed when installing the RRH on 121mm
to 400mm diameter pole with pole brackets and pole bands.
Only one RRH can be installed on a pole with the large pole mounting kit.
The RRH can be installed on the large pole with the two following positions :

DN09249151 Issue: 04 © 2018 Nokia 63
   

Transport, mount, and ground RRH LTE B31 RRH2x40 (UHAA) Installation Manual

A kit to adapt metallic bands on pole must be used together with components from the
standard pole mounting kit.
The following kits is used to mount one RRH :

f WARNING! fall
Falls can occur when working at heights resulting in serious personal injury or death.
To prevent a fall when working at heights (ladder, scaffold, manlift, roof etc.) follow safe
work practices and wear appropriate fall protection equipment.

64 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual Transport, mount, and ground RRH

Procedure

1 Screw the two large pole brackets to the standard Pole Bracket using four M6x14 bolts.
Torque to 5 N*m.

2 Screw the Main Bracket to the Pole Bracket using four M6x14 bolts. Torque to 5 N*m.

3 Determine a position for installing the mounting brackets. Pass the metal bands through
the outer rectangular holes in the large pole brackets and strap the assembly to the pole.

g Note: Adjust the position of the basement(s) so that they are centered on the horizontal
and vertical lines marked on the pole.

4 The band will lock into the lever on the band clamp. Once the band is pulled tight, tighten
the nuts on the band clamps to 30 N*m.

DN09249151 Issue: 04 © 2018 Nokia 65
   

Transport, mount, and ground RRH LTE B31 RRH2x40 (UHAA) Installation Manual

5 Fix the accessory to the RRH and lift the RRH.

6 Attach the RRH with accessory to the basement, Use an inner hexagon torque wrench to
tighten the captive screw into the holes on the top of the attachment plate and main
bracket to5N•m (44.25lb-in.) so that the attachment plate and main bracket are firmly
secured.

6.2.5 Installing the RRH on U-steel


Purpose

This section describes the procedure and precautions for installing the RRH on U-steel.
An RRH can be installed on U-steel secured on the ground or a tower. Each piece of U-
steel allows only one RRH to be installed in standard or reverse mode.
The figure shows the U-steel specifications:

The figure shows the top view of the RRH installed on the U-steel:

66 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual Transport, mount, and ground RRH

g Note: When the width of the narrower edges of the U-steel is less than 40 mm (1.57
in.), only the a and b modes are supported.

f WARNING! fall
Falls can occur when working at heights resulting in serious personal injury or death.
To prevent a fall when working at heights (ladder, scaffold, manlift, roof etc.) follow safe
work practices and wear appropriate fall protection equipment.

Before you start


Before you install an RRH on U-steel secured on a tower:
• Tthe RRH and its mounting brackets are hoisted onto the tower.
• The hoist clamp on the main bracket is secured properly.

g Note:
• Do not stand the RRH upright because the RF ports cannot support the weight of
the RRH.
• Place a foam pad or cardboard under the RRH to protect the RRH housing from
damage during the installation.

DN09249151 Issue: 04 © 2018 Nokia 67
   

Transport, mount, and ground RRH LTE B31 RRH2x40 (UHAA) Installation Manual

Procedure

1 Determine a position for installing the mounting brackets.

• If the pole must be installed on U-steel secured on a tower, determine a position
for installing the mounting brackets according to the instructions Clearance for a
Single RRH in 3MN-00804-0001-RJZZA B31 RRH2x40 Site Preparation
Guidelines.
• If the RRH must be installed on U-steel secured on the ground, determine a
position for installing the mounting brackets:

g Note: It is recommended that the mounting brackets be installed at a height of 1200
mm (47.24 in.) to 1600 mm (62.99 in.) above the ground.

68 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual Transport, mount, and ground RRH

2 Install the RRH mounting brackets, as shown:

Verify that the arrows on the mounting brackets are pointing up.
• Adjust the position of the nut and remove one end of the square-neck bolt from
the slot on the auxiliary bracket.
• Slide the mounting brackets onto the U-steel horizontally and insert the square-
neck bolt into the slot

DN09249151 Issue: 04 © 2018 Nokia 69
   

Transport, mount, and ground RRH LTE B31 RRH2x40 (UHAA) Installation Manual

3 Use a 16 mm (0.63 in.) M10 torque wrench to tighten the nuts to 40 N•m (354.03 lbf•in.)
so that the mounting brackets are secured onto the U-steel, as shown:

g Note: Tighten the nuts on the two square-neck bolts alternately. After the main and
auxiliary brackets are secured properly, measure the spacing between the brackets on
both sides and ensure that the spacing is the same on the two sides.

70 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual Transport, mount, and ground RRH

4 Use an inner hexagon wrench to remove the attachment plate from one side of the RRH,
reinstall the attachment plate onto the rear of the RRH, and tighten the four stainless
screws to 5 N•m (44.25lb-in.), as shown:

5 Install the RRH onto the main bracket, as shown:

DN09249151 Issue: 04 © 2018 Nokia 71
   

Transport, mount, and ground RRH LTE B31 RRH2x40 (UHAA) Installation Manual

6 Use an inner hexagon torque wrench to tighten the captive screw into the holes on the
top of the attachment plate and main bracket to 5 N•m (44.25 lb-in.) so that the
attachment plate and main bracket are firmly secured.

The figure shows securing the captive screw into the connection hole:

6.2.6 Installing the RRH on Angle Steel


Purpose

This section describes the procedure and precautions for installing the RRH on angle
steel. An RRH can be installed on angle steel secured on the ground or a tower. Each
piece of angle steel allows only one RRH to be installed in standard or reverse mode.
The figure shows the angle steel specifications:

72 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual Transport, mount, and ground RRH

The figure shows the top view of the RRH installed on the angle steel:

DN09249151 Issue: 04 © 2018 Nokia 73
   

Transport, mount, and ground RRH LTE B31 RRH2x40 (UHAA) Installation Manual

f WARNING! fall
Falls can occur when working at heights resulting in serious personal injury or death.
To prevent a fall when working at heights (ladder, scaffold, manlift, roof etc.) follow safe
work practices and wear appropriate fall protection equipment.

Before you start


Before you install an RRH on a angle steel secured on a tower:
• Tthe RRH and its mounting brackets are hoisted onto the tower.
• The hoist clamp on the main bracket is secured properly.

g Note:
• Do not stand the RRH upright because the RF ports cannot support the weight of
the RRH.
• Place a foam pad or cardboard under the RRH to protect the RRH housing from
damage during the installation.

Procedure

1 Determine a position for installing the mounting brackets.

• If the pole must be installed on Angle steel secured on a tower, determine a
position for installing the mounting brackets according to the instructions
Clearance for a Single RRH in 3MN-00804-0001-RJZZA B31 RRH2x40 Site
Preparation Guidelines.
• If the RRH must be installed on angle steel secured on the ground, determine a
position for installing the mounting brackets:

74 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual Transport, mount, and ground RRH

g Note: It is recommended that the mounting brackets be installed at a height of 1200
mm (47.24 in.) to 1600 mm (62.99 in.) above the ground.

DN09249151 Issue: 04 © 2018 Nokia 75
   

Transport, mount, and ground RRH LTE B31 RRH2x40 (UHAA) Installation Manual

2 Install the RRH mounting brackets, as shown:

Verify that the arrows on the mounting brackets are pointing up.
• Adjust the position of the nut and remove one end of the square-neck bolt from
the slot on the auxiliary bracket.
• Slide the mounting brackets onto the angle steel horizontally and insert the
square-neck bolt into the slot

76 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual Transport, mount, and ground RRH

3 Use a 16 mm (0.63 in.) M10 torque wrench to tighten the nuts to 40 N•m (354.03 lbf•in.)
so that the mounting brackets are secured onto the angle steel, as shown:

g Note: Tighten the nuts on the two square-neck bolts alternately. After the main and
auxiliary brackets are secured properly, measure the spacing between the brackets on
both sides and ensure that the spacing is the same on the two sides.

DN09249151 Issue: 04 © 2018 Nokia 77
   

Transport, mount, and ground RRH LTE B31 RRH2x40 (UHAA) Installation Manual

4 Use an inner hexagon wrench to remove the attachment plate from one side of the RRH,
reinstall the attachment plate onto the rear of the RRH, and tighten the four stainless
screws to 5 N•m (44.25lb-in.), as shown:

5 Install the RRH onto the main bracket, as shown:

78 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual Transport, mount, and ground RRH

6 Use an inner hexagon torque wrench to tighten the captive screw into the holes on the
top of the attachment plate and main bracket to 5 N•m (44.25 lb-in.) so that the
attachment plate and main bracket are firmly secured.

The figure shows securing the captive screw into the connection hole:

6.2.7 To ground the RRH


Purpose

This topic describes how to ground the RRH.
The RRH PGND cable connects an RRH and a ground bar, ensuring the proper
grounding of the RRH. The maximum length of an RRH PGND cable is 8 m (26.25 ft).

Ground cable and area at RRH


A PGND cable is green or green and yellow with a cross-sectional area of 16 mm2
(0.025 in.2). An ring terminal is installed at each end of the cable:

DN09249151 Issue: 04 © 2018 Nokia 79
   

Transport, mount, and ground RRH LTE B31 RRH2x40 (UHAA) Installation Manual

Ring terminals are supplied with the RRH in the basic installation kits.
The grounding areas are located at the bottom of the RRH:

Procedure

1 According to the actual cable route, cut the PGND cable into a proper length to prepare
an RRH PGND cable. Then add an ring terminal at each end of the cable.

g Note: The cross-sectional area of an RRH PGND cable is 16 mm2 (0.025 in.2).

2 Connect the M6 ring terminal at one end of the PGND cable to the ground terminal at the
RRH bottom and the M8 ring terminal at the other end to the external ground bar.

Installing an PGND cable of the RRH:

80 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual Transport, mount, and ground RRH

3 Crimp ring terminals in correct positions.

Correct position of an ring terminal:

4 Connect each ground lug to the RRH using the supplied screws, lock washers, and flat
washers. Use antioxidant at the grounding pads.

DN09249151 Issue: 04 © 2018 Nokia 81
   

Transport, mount, and ground RRH LTE B31 RRH2x40 (UHAA) Installation Manual

5 Label the installed cables.

82 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual Connect interface and RRH cables

7 Connect interface and RRH cables


This chapter provides instructions for routing and connecting the following cables to the
RRH:
• RF cable
• AISG multi-core cable (optional)
• AISG extension cable (optional)
• User alarm cable (optional)
• Power cable
• CPRI optics cable.

Cabling Requirements
Cables must be routed according to the specified cabling requirements to prevent signal
interference.
Requirements for Bending Radius:
• The bending radius of the 7/8'' feeder must be more than 250 mm (9.84 in.), and the
bending radius of the 5/4'' feeder must be more than 380 mm (14.96 in.).
• The bending radius of the 1/4'' jumper must be more than 35 mm (1.38 in.). The
bending radius of the super-flexible 1/2'' jumper must be more than 50 mm (1.97 in.),
and the bending radius of the ordinary 1/2'' jumper must be more than 127 mm (5
in.).
• The bending radius of the power cable or PGND cable must be at least three times
the diameter of the cable.
• The bending radius of a fiber optic cable is at least 20 times the diameter of the fiber
optic cable, and the minimum bending radius of the breakout cable at each end of
the fiber optic cable is 30 mm (1.18 in.).
• The bending radius of the signal cable must be at least five times the diameter of the
cable.

Requirements for Cable Binding:
• The same types of cable must be bound together.
• Different types of cable must be separately routed with the minimum spacing of 30
mm (1.18 in.) and cannot be entangled.
• The cables must be bound tightly and neatly. The sheaths of the cables must not be
damaged.
• Labels or nameplates must be attached to both ends, joints, or turns of cables after
they are installed.

g Note: When routing RRH cables, ensure that the highest positions of the routes of all
RRH cables (except RF cables and AISG cables) must be lower than the bottom of the
RRH.

To connect the RRH to antennas with 7/16 connectors, two types of connector are
considered:
• Straight Connectors on both sides of the cable for general usage.

DN09249151 Issue: 04 © 2018 Nokia 83
   

Connect interface and RRH cables LTE B31 RRH2x40 (UHAA) Installation Manual

• Right Angled connector on one side and straight connector on other side.
This type of RF jumper should be needed in case of B31 RRH2x40 indoor installation
on top of LR cabinet when free space at RRH bottom is reduced at the minimum
(100mm).

Cable Connections
This section describes the cable connections for RRHs.
The following figure shows the Cable connections of a single-mode RRH:

The following figure shows the cable connections of multiple single-mode RRHs:

84 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual Connect interface and RRH cables

RRH Cable List


This section describes RRH cable connections.

cable One end (RRH side) The other end (BBU or other
equipment side)

Connector Installation Connector Installation


position position

RRH PGND OT terminal Ground terminal OT terminal Ground terminal on


Cable (M6, 16 mm2 or on the RRH (M8, 16 mm2 or the ground bar
0.025 in.2) 0.025 in.2)
RRH Power Tool-less female NEG(-) and Depending on External power
Cable connector RTN(+) ports on the power equipment
(pressfit type) the RRH supply
equipment
RRH Alarm Cable DB15 EXT_ALM port on Cord end External alarm
waterproof male the RRH terminal device
connector
CPRI Fiber Optic DLC connector CPRI0 port on the DLC connector CPRI port on a
Cable (in single- RRH board in the BBU
mode scenarios)
RRH RF Jumper DIN male RF ports on the DIN male Antenna system
connector RRH connector

DN09249151 Issue: 04 © 2018 Nokia 85
   

Connect interface and RRH cables LTE B31 RRH2x40 (UHAA) Installation Manual

cable One end (RRH side) The other end (BBU or other
equipment side)

Connector Installation Connector Installation


position position

RRH AISG Multi- DB9 waterproof RET port on the Standard AISG Standard AISG


Wire Cable male connector RRH female male connector on
connector the BBU or on the
AISG extension
cable
RRH AISG Standard AISG Standard AISG Standard AISG Standard AISG
Extension Cable male connector female connector female male connector on
on the AISG multi- connector the BBU
wire cable

7.1 Route and connect RF jumper cables

This topic provides all necessary information and procedural instructions to route and
connect the RF cables to the Remote Radio Head (RRH).

RF jumpers
The 1/2" RRH RF jumper transmits and receives RF signals between an RRH and an
antenna. A fixed-length RF jumper used by an RRH is 2 m (6.56 ft), 3 m (9.84 ft), 4 m
(13.12 ft), 6 m (19.68 ft), or 10 m (32.81 ft). A variable-length RF jumper used by an RRH
has a maximum length of 10 m (32.81 ft).

g Note: 1m, 2m, 3m jumpers are offered ordinarily.

An RF jumper has DIN male connectors at both end:

86 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual Connect interface and RRH cables

g Note:
• When the distance between an RRH and an antenna is less than 10 m (32.81 ft),
one end of the RF jumper is connected to the ANT-TX/RXA or ANT-TX/RXB port at
the bottom of the RRH, and the other end is connected to the antenna.
• When the distance between an RRH and an antenna is greater than 10 m (32.81 ft),
one end of the RF jumper is connected to a feeder, and the other end is connected
to the antenna.
• If the customer prepares the RF jumper, the length of the RF jumper should be as
short as possible and not exceed 2 m (6.56 ft.).

7.1.1 Route and connect RF jumper cables to the RRH


Purpose
Use the following procedure to connect the RF jumper cables to the RF ports on bottom
of the RRH.

Before you start


This procedure assumes the following requirements have been met.
• Cable shield grounding has been completed for all antenna cables at a point outside
of the eNodeB.

The RF jumper cables must be labeled at both ends so they can be properly connected.

Procedure

1 Connect the DIN male connector at one end of the RRH RF jumper to the ANT port on
the RRH, and use a torque wrench to tighten the connector to 25 N•m (221.27 lbf•in.).

The following figure shows Installing an RRH RF jumper:

DN09249151 Issue: 04 © 2018 Nokia 87
   

Connect interface and RRH cables LTE B31 RRH2x40 (UHAA) Installation Manual

f On AC-powered electric railways, such as high speed railways, when leaky cables are
connected to RRHs installed in tunnels, high-voltage-resistance DC blocks must be
installed between RRH RF jumpers and the leaky cables to protect the RRHs against
damage.

2 Link the other end of the RF jumper to the external antenna system.

3 Waterproof the connectors of the RF jumper, referring to the section Waterproofing a
connector of the RF jumper:

4 Check the dustproof caps on antenna connectors. In outdoor scenarios, dustproof caps
must be waterproofed.

5 Route the cables according to the instructions in Cabling Requirements , and then use


cable ties to bind the cables.

6 Label the installed cables.

7 Attach color-coding to the installed RF jumper.

7.1.2 Waterproofing a connector of the RF jumper


Purpose
Use the following procedure to waterproof a connector of the RF jumper.

g Note:
• Before wrapping waterproof tape, stretch the tape evenly until the length of the tape
becomes twice its original length
• Do not stretch the PVC insulation tape when wrapping the PVC insulation tape
• Wrap each layer of tape around the connector tightly and neatly, and ensure that
each layer of tape overlaps more than 50% of the preceding layer. Ensure that
neighboring layers are stuck to each other
• Ensure that the adhesive surface of the tape overlaps the lower layer
• When cutting off the cable ties, reserve a redundant length of 3 mm (0.12 in.) to 5
mm (0.2 in.)

Before you start


This procedure assumes the following requirements have been met.

88 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual Connect interface and RRH cables

• Cable shield grounding has been completed for all antenna cables at a point outside
of the eNodeB.

The RF jumper cables must be labeled at both ends so they can be properly connected.

Procedure

1 Wrap three layers of waterproof tape on the connector, first from bottom up, then from
top down, and finally from bottom up.

Start wrapping the connector at a position 50 mm (1.97 in.) away below the bottom of
the connector to the top of the connector, first from bottom up, then from top down,
and finally from bottom up.
Cut off the redundant tape after three layers are wrapped. Wrap each layer of tape
around the connector tightly.

2 Wrap three layers of PVC insulation tape.

Start the wrapping at a position 30 mm (1.18 in.) away below the bottom of the
waterproof tape to the top of the connector, first from bottom up, then from top down,
and finally from bottom up.
Cut off the redundant tape after three layers are wrapped. Wrap each layer of tape
around the connector tightly.

DN09249151 Issue: 04 © 2018 Nokia 89
   

Connect interface and RRH cables LTE B31 RRH2x40 (UHAA) Installation Manual

3 Start binding cable ties to the cable at a position 3 mm (0.12 in.) to 5 mm (0.2 in.) away
from one end of the PVC insulation tape.

7.2 Route and connect RRH AISG Multi-Wire Cable and


AISG Extension Cable(Optional)

This topic provides all necessary information and procedural instructions to route and
connect the AISG Multi-Wire Cable and AISG Extension Cable to the Remote Radio
Head (RRH).

AISG cable connection


An RRH AISG multi-wire cable connects an RRH and an BBU to transmit control signals
from a base station to an RET antenna. When the RRH is connected to the RET
antenna, an AISG multi-wire cable transmits RS485 signals. The length of the AISG
multi-wire cable is 5 m (16.40 ft).

90 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual Connect interface and RRH cables

An AISG multi-wire cable has a waterproofed DB9 male connector at one end and a
standard AISG female connector at the other end.
The following figure shows the AISG multi-wire cable:

When the distance between an RRH and the BBU is longer than 5 m (16.4 ft.), an AISG
multi-wire cable is not long enough to connect the RRH and the BBU. In this case, an
AISG extension cable is used to extend the AISG multi-wire cable for transmitting RS485
signals. The length of the AISG extension cable can be 1, 2, 5, or 10 m.
An AISG extension cable has a standard AISG male connector at one end and a
standard AISG female connector at the other end:

7.2.1 Route and connect an AISG multi-wire cable without AISG


extension cable
Purpose
Perform the following steps to route and connect an AISG multi-wire cable that is not
configured with an AISG extension cable.

Procedure

1 Use an M3 flat-head screwdriver to loosen the screws on the dustproof cap on the RET
port and remove the dustproof cap.

DN09249151 Issue: 04 © 2018 Nokia 91
   

Connect interface and RRH cables LTE B31 RRH2x40 (UHAA) Installation Manual

2 Link the waterproofed DB9 connector at one end the AISG multi-wire cable to the RET
port on the RRH bottom.

Installing an RRH AISG multi-wire cable:

3 Use an M3 Phillips screwdriver to tighten the posts on both sides of the waterproof DB9
connector to 0.4 N•m (3.54lb-in.)

4 Connect the other end of the cable to the standard AISG male connector on the BBU.

5 Route the cables according to the instructions in Cabling Requirements, and then use
cable ties to bind the cables.

6 Label the installed cables according to the instructions in Attaching an L-Shaped Label.

7.2.2 Route and connect an AISG multi-wire cable with AISG


extension cable
Purpose
Perform the following steps to route and connect an AISG multi-wire cable that is
configured with an AISG extension cable.

92 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual Connect interface and RRH cables

Procedure

1 Use an M3 flat-head screwdriver to loosen the screws on the dustproof cap on the RET
port and remove the dustproof cap.

2 Link the waterproofed DB9 connector at one end of the AISG multi-wire cable to the RET
port on the RRH bottom, and link the other end to the standard AISG male connector of
the AISG extension cable.

Installing an RRH AISG multi-wire cable:

3 Use an M3 Phillips screwdriver to tighten the posts on both sides of the waterproof DB9
connector to 0.4 N•m (3.54lb-in.)

4 Connect the other end of the AISG extension cable to the standard AISG male connector
on the BBU.

Installing an RRH AISG extension cable:

DN09249151 Issue: 04 © 2018 Nokia 93
   

Connect interface and RRH cables LTE B31 RRH2x40 (UHAA) Installation Manual

5 Route the cables according to the instructions in Cabling Requirements, and then use
cable ties to bind the cables.

6 Label the installed cables according to the instructions in Attaching an L-Shaped Label.

7.3 Route and connect RRH alarm cables


Purpose

This topic provides all necessary information and procedural instructions to route and
connect the user alarm cables to the Remote Radio Head ( RRH ).

User alarm cables


The RRH alarm cable, a shielded straight-through cable, transmits alarm signals from an
external device to an RRH so that the base station monitors the operating status of
external devices. The RRH alarm cable is 5 m (16.4 ft).
An alarm cable has a DB15 waterproof male connector at one end and eight cord end
terminals at the other end:

94 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual Connect interface and RRH cables

User alarms wire colors and pinout configuration


The following table shows the pin assignment for the wires of an RRH alarm cable

Procedure

1 Use an M3 Phillips screwdriver to loosen the screws on the dustproof cap on the
EXT_ALM port and remove the dustproof cap.

DN09249151 Issue: 04 © 2018 Nokia 95
   

Connect interface and RRH cables LTE B31 RRH2x40 (UHAA) Installation Manual

2 Connect the waterproof DB15 connector at one end of the RRH alarm cable to the
EXT_ALM port on the RRH.

3 Use an M3 Phillips screwdriver to tighten the posts on both sides of the waterproof DB15
male connector to 0.4 N•m (3.54 lb-in.)

4 Connect the eight cord end terminals at the other end to external alarm devices.

g Note: Use insulating adhesive tapes to wrap cord end terminals that are not in use and
fix them at a proper position based on the onsite situations. This prevents false alarm
reporting and equipment damage due to contact of exposed cables.

The following figure shows the method for handling cord end terminals not in use.

5 Route the cables according to the instructions in Cabling Requirements, and then use
cable ties to bind the cables.

96 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual Connect interface and RRH cables

6 Label the installed cables.

7.4 Opening the Cover Plate of an RRH Cabling Cavity


Purpose

This topic provides all necessary information and procedural instructions to open the
cover plate of an RRH cabling cavity.

Procedure

1 Wear ESD gloves.

w Take proper ESD protection measures, for example, wear ESD gloves, to prevent
electrostatic damage to the boards, modules, or electronic components.

f Removing the cover plate from the cabling cavity exposes sensitive components to the
elements. The unit must be protected from precipitation until the cover is replaced and
torqued to specifications.

DN09249151 Issue: 04 © 2018 Nokia 97
   

Connect interface and RRH cables LTE B31 RRH2x40 (UHAA) Installation Manual

2 Use an M5 Phillips screwdriver to loosen the three screws on the cover plate of the RRH
cabling cavity, and open the cover plate.

98 © 2018 Nokia DN09249151 Issue: 04
   

LTE B31 RRH2x40 (UHAA) Installation Manual Connect interface and RRH cables

3 Loosen the screws on the clip using an M4 Phillips screwdriver, and open the clip.

g Note: Open the clip only for the associated cable.

4 Remove the waterproof block.

g Note: Remove only the waterproof blocks for the cables to be installed.

7.5 To route and connect an RRH power cable

This topic covers the procedures for connecting an RRH power cable.

Power cables
The RRH power cable is a -48 V DC cable. It feeds -48 V DC power to an RRH.

DN09249151 Issue: 04 © 2018 Nokia 99
   

Connect interface and RRH cables LTE B31 RRH2x40 (UHAA) Installation Manual

g Note:
• The maximum distance between the power supply and the RRH is 35 m (115 ft)
with 4 mm2 cable. If an RRH power cable greater than 35 m (115 ft) is required, 6
mm2 or 10 mm2 cable can be used with a special adaptor kit that can be crimped
on to the power cable near the cabling cavity.
• If a power device provided by the customer is used, the recommended specification
of the circuit breaker on this power device is 15 A to 30 A.

There are three types of RRH power cables in terms of cross-sectional areas: 3.3 mm2
(0.005 in.2) (12 AWG) and 5.3 mm2 (0.008 in.2) (10 AWG) complying with North
American standards and 4 mm2 (0.006 in.2) complying with European standards.
A tool-less female connector (pressfit type) needs to be added to one end of the RRH
power cable and a corresponding terminal needs to be added to the other end based on
the requirements of the connector on the external power device.
power cable as shown:

g Note: In case of the RRH-Power Supply distance is longer than supported by 2x4mm2
section, the power cable copper section for each wire must be 6mm2 or 10mm2.
The Power supply cables 2x6mm2 and 2x10mm2 cannot be directly connected to the
RRH because of their out/external diameter >11mm.

An adaptor is needed to connect the cable to the RRH, the following 6_10mm2 power
cable adaptor kit as shown:

Specifications of an RRH power cable


The following table lists the specifications of an RRH power cable.

100 © 2018 Nokia DN09249151 Issue: 04


   

LTE B31 RRH2x40 (UHAA) Installation Manual Connect interface and RRH cables

7.5.1 Route and connect DC power cables to the RRH


Purpose
Perform the following procedure to connect the DC power cables to the RRH.

f WARNING!
Risk of injury or/and equipment damage by electricity.
The circuit breaker dedicated to the RRH must be DISCONNECTED.

Before you start


A tool-less female connector (pressfit type) is added to the RRH power cable on the
RRH side.
A connector or OT terminals are added to the RRH power cable on the power device
side.

f Ensure that the RRH power cable must be connected to the RRH first and then to the
power device. The operations in the reverse sequence may cause component damage
or personal injury.

Procedure

1 Connect the tool-less female connector (pressfit type) at one end of the RRH power
cable to the power supply socket on the RRH, Add a Tool-Less Female Connector
(Pressfit Type) to the RRH Power Cable on the RRH side .

Installing an RRH power cable:

DN09249151 Issue: 04 © 2018 Nokia 101


   

Connect interface and RRH cables LTE B31 RRH2x40 (UHAA) Installation Manual

2 Connect the connector at the other end of the RRH power cable to the corresponding
position on the power device.

3 Route the cable according to the instructions in Cabling Requirements, and then use a
cable tie to bind the cable.

4 Label the installed cable.

7.5.2 Add a Tool-Less Female Connector (Pressfit Type) to the


RRH Power Cable on the RRH side
Purpose
Perform the following procedure to Add a Tool-Less Female Connector (Pressfit Type) to
the RRH Power Cable on the RRH side.

Before you start


A tool-less female connector (pressfit type) is added to the RRH power cable on the
RRH side.
A connector or OT terminals are added to the RRH power cable on the power device
side.

f Ensure that the RRH power cable must be connected to the RRH first and then to the
power device. The operations in the reverse sequence may cause component damage
or personal injury.

102 © 2018 Nokia DN09249151 Issue: 04


   

LTE B31 RRH2x40 (UHAA) Installation Manual Connect interface and RRH cables

Procedure

1 Strip off a specified length of the outer jacket of the cable and sheath of each core wire.
The length must be consistent with the length of the notch in the tool-less female
connector (pressfit type), as shown:

Stripping the sheath off each core wire:

Matched length:

2 Add a tool-less female connector (pressfit type) to two core wires.

• Tighten the screws using a Phillips screwdriver:

• Connect the blue core wire labeled NEG(-) to the - port and the black/brown core
wire labeled RTN(+) to the + port on the tool-less female connector (pressfit
type), and then tighten the screws using a Phillips screwdriver, as shown:

DN09249151 Issue: 04 © 2018 Nokia 103


   

Connect interface and RRH cables LTE B31 RRH2x40 (UHAA) Installation Manual

3 Each core wire is exposed outside the tool-less female connector (pressfit type) for 1.5
mm (0.059 [in.]), as shown:

Inserting core wires into the tool-less female connector (pressfit type):

7.6 Route and connect CPRI optical fiber cables


Purpose

This topic provides all necessary information and procedural instructions to route and
connect the CPRI optical fiber cables to the Remote Radio Head.

Pin Assignment
Labels on and recommended connections for the breakout cables of a CPRI fiber optic
cable.

104 © 2018 Nokia DN09249151 Issue: 04


   

LTE B31 RRH2x40 (UHAA) Installation Manual Connect interface and RRH cables

w NOTICE:  The optical cable is very sensible, take the maximum precaution when
installing it. Never clean the fiber with a dry tissue. Never touch (with the fingers) the
fiber end face of the connector. Do not use tie wrap on the fiber cable. The fiber optic
connector should be protected by cap when not being used. Respect the bending
radius during the manipulation of optic cable (82.5mm)
.

g Note: 7mm is the required diameter for optical cable to ensure a correct waterproofing
in case of outdoor installation when cavity area is closed. In case of 5.5mm OD for
Optical fibers, on RRH side, PVC Rubber must be used to fit the optic cable external
diameter to 7mm.

Before you start


Before the installation, single-mode optical modules can be distinguished from multi-
mode optical modules in either of the following ways:
• SM and MM labels on an optical module: SM indicates a single-mode optical module,
and MM indicates a multi-mode optical module.
• Color of the puller on an optical module: Blue indicates a single-mode optical
module, and black or gray indicates a multi-mode optical module.

Procedure

1 Lower the pullers of two optical modules, insert one optical module into the SFP in
CPRI0 port on the RRH and the other optical module into the SFP in CPRI port on the
BBU, and raise the pullers.

Installing an optical module:

DN09249151 Issue: 04 © 2018 Nokia 105


   

Connect interface and RRH cables LTE B31 RRH2x40 (UHAA) Installation Manual

f The performance of an optical module that is exposed to the air for more than 20
minutes may be abnormal. Therefore, you must insert an fiber optic cable into an
unpacked optical module within 20 minutes.

2 Connect the end labeled 1A and 1B of the fiber optic cable to the optical module on the
RRH side.

Installing a CPRI fiber optic cable:

106 © 2018 Nokia DN09249151 Issue: 04


   

LTE B31 RRH2x40 (UHAA) Installation Manual Connect interface and RRH cables

f To avoid any damage to fiber optic cables, the cables connected to the RRH must be
installed according to the installation process.

3 If daisy chaining is used between 2 RRHs, put the 2nd SFP into CPRI1 port on the RRH
and Connect the fiber cable to the optical module on the RRH side.

4 Connect the end labeled 2A and 2B of the fiber optic cable to the optical module on the
BBU side.

5 Route the cables according to the instructions in Cabling Requirements.

6 Label the installed cables.

7.7 Closing the Cover Plate of an RRH Cabling Cavity


Purpose

This topic provides all necessary information and procedural instructions to close the
cover plate of an RRH cabling cavity.

DN09249151 Issue: 04 © 2018 Nokia 107


   

Connect interface and RRH cables LTE B31 RRH2x40 (UHAA) Installation Manual

Procedure

1 Close the clips for the installed cables. Use an M4 torque screwdriver to tighten the
screws on each clip to 1.4 N•m (12.39lb-in.).

108 © 2018 Nokia DN09249151 Issue: 04


   

LTE B31 RRH2x40 (UHAA) Installation Manual Connect interface and RRH cables

g Note: Ensure that the clip tightens down on the larger diameter of the shrink tubing on
the fiber cable (in the left (CPRI0) position only).

2 Insert waterproof blocks into vacant cable troughs in the cabling cavity.

w Ensure that cables and waterproof blocks are properly inserted into troughs.

Correct placement of waterproof blocks if only one fiber cable is present:

DN09249151 Issue: 04 © 2018 Nokia 109


   

Connect interface and RRH cables LTE B31 RRH2x40 (UHAA) Installation Manual

3 If the 2nd SFP installed and the diameter of the fiber cable in the right (CPRI1) position is
less than 7mm, wrap PVC insulation tape (from the Waterproofing a connector
of the RF Jumper section) in the clamp area until the diameter is more than 7mm.

g Note: The fiber cable should not be allowed to move up or down after the clamp screw
is tightened.

110 © 2018 Nokia DN09249151 Issue: 04


   

LTE B31 RRH2x40 (UHAA) Installation Manual Connect interface and RRH cables

4 Close the cover plate of the RRH cabling cavity. Use an M5 torque screwdriver to
partially tighten the screws on the cover plate in the sequence shown in the following
figure. Then tighten the screws to 2 N•m (17.7lb-in.) in the same sequence.

Closing the cover plate of an RRH cabling cavity:

5 Take off the ESD gloves, and pack up all the tools.

DN09249151 Issue: 04 © 2018 Nokia 111


   

Finish the installation and power on a RRH LTE B31 RRH2x40 (UHAA) Installation Manual

8 Finish the installation and power on a RRH


This chapter provides the checklist for the RRH hardware installation and power on a
RRH.

8.1 To check the RRH hardware installation and the


power on status
Purpose

This topic provides the checklist for the RRH hardware installation.

Checklist for the RRH hardware installation


After an RRH is installed, check the hardware installation:

SN Item

1 The position for each device conforms to the engineering drawing and meets the space
requirement. Sufficient space is reserved for equipment maintenance.
2 The RRH is securely installed.
3 The cover plate is securely installed on the RRH cabling cavity.
4 Waterproof blocks are securely installed in vacant cable troughs of the RRH cabling cavity,
and the cover plate for the cabling cavity is securely installed. In addition, vacant RF ports
are covered with dustproof caps and the caps are tightened.
5 There are no connectors or joints on each power cable or PGND cable.
6 The terminals at two ends of each power cable or PGND cable are securely soldered or
crimped.
7 None of power cables and PGND cables can be short-circuited or reversely connected. In
addition, these cables are not damaged or broken.
8 Power cables and PGND cables are separately bound from other cables.
9 The protection grounding of the RRH and the surge protection grounding of the building
share one group of ground conductors.
10 The connectors of each signal cable are intact and securely linked, and these cables are
not damaged or broken.
11 Labels are correct, legible, and complete at both ends of each cable, feeder, and jumper.

After all the devices are installed, check the power-on status of an RRH.(a) The normal


input voltage of an RRH is -48 V DC. The voltage of the external power supply should
range from -36 V DC to -57 V DC.(b) The RUN indicator on the RRH is on for 1s and off
for 1s. The ALM indicator is steady off.

f After you unpack an RRH, you must power on it within 24 hours. If you power off the
RRH for maintenance, you must restore power to the RRH within 24 hours.

112 © 2018 Nokia DN09249151 Issue: 04


   

LTE B31 RRH2x40 (UHAA) Installation Manual Finish the installation and power on a RRH

The following figure shows the RRH power-on check process.

DN09249151 Issue: 04 © 2018 Nokia 113


   

Appendix: Product conformance statements LTE B31 RRH2x40 (UHAA) Installation Manual

9 Appendix: Product conformance statements


This section presents the product conformance statements that apply to the RRH.
The presence of the statement indicates that the product does comply with that
statement wherever it is required to do so.

9.1 European Union


Introduction
The statements that follow are the product conformance statements that apply to the
bearing the CE Marking and when deployed in the European Union.

Declaration of Conformity for radio and telecommunication terminal equipment


under the scope of Directive 1999/5/EC
Hereby, We declares that the equipment documented in this publication is in compliance
with the essential requirements and other relevant provisions of Directive 1999/5/EC.
The technical documentation as required by the Conformity Assessment procedure is
kept at the Nokia location which is responsible for this product. For more information
please contact your local Nokia Customer Service Organization.

CE marking
This product has been CE-marked in accordance with the following European Directive:
• Radio and Telecommunication Terminal Equipment (R&TTE) 1999/5/EC

EMC and radio spectrum compliance for the 850 MHz product
The equipment complies with the following EMC and radio spectrum specifications:
• EN 300 339 V1.1.1 (1998-06)
• ETSI EN 301 489-1 V1.6.1 (2005-09)
• ETSI EN 301 489-26 V2.3.1 (2005-07)
• ETSI EN 301 908-1 V2.2.1 (2003-10)
• Code of Federal Regulations FCC part 24(E)
• IS 3GPP2 - C.S0010-B

Product safety conformance


The equipment complies with the following product safety specifications:
• EN 60950-1:2001
• EN 60215:1989

Telecommunications Standards
The equipment complies with the following telecommunication specifications:

114 © 2018 Nokia DN09249151 Issue: 04


   

LTE B31 RRH2x40 (UHAA) Installation Manual Appendix: Product conformance statements

• Technical Basis Regulation TBR 13

Antenna exposure
Antenna installations for the shall be performed in accordance with all applicable
manufacturer's recommendations, and national laws and regulations. To ensure correct
antenna installation, the antenna installer shall perform all necessary calculations and/or
field measurements to evaluate compliance with applicable national laws or regulations
regarding exposure to electromagnetic fields. The supplier of radio equipment, the
supplier of antenna equipment and the integrator and builder of the site must provide
sufficient information so that the limits of the exclusion zones can be determined. Any
changes to the antenna or other equipment in the transmit path may require re-
evaluation of the exposures to electromagnetic fields.
Pursuant to
• European Council Recommendation 1999/519/EC “On the limitation of exposure of
the general public to electromagnetic fields” dated 12 July 1999 and
• ICNIRP (International Commission on Non-Ionising Radiation Protection) “Guidelines
for limiting exposure to time-varying electric, magnetic, and electromagnetic fields”,

all installations must be evaluated against the Reference Levels, and if necessary
exclusion zones for public and installation workers defined.
The following information on Nokia supplied equipment is available from customer
representatives: 
• Output power and antenna characteristic, if the product is equipped with an integral
antenna.
• A detailed description of at least one typical normal configuration, including antenna
system (feeders, connectors, combiners, antennas etc.), if the product is intended to
be used with external antennas.
• Limit distances for general public and occupational exposure. If the product is
intended for use with external antennas, limit distances shall be given for the given
typical system configurations.
• Information how to specify exposure levels and limit distances for any optional
system configuration not specified in detail.
• Information on how to install the equipment/system or the external antennas in order
to ensure that the separation between the radiating antenna and general public are
exceeding the maximum allowed distances.

Information on the methodology used for the determination of RF safety compliance
distances and exclusion zones, and the results of the compliance evaluation shall be
available for inspection by officials of the governing authorities.

Optical transmitters
We declares that the complies with the CENELEC standards EN 60825-1 Edition 1994
and its amendment 1 (2002) and amendment 2 (2001) and EN 60825-2 Edition 2004. It
is a Class I/1 laser optical fiber communication systems “product” under the IEC
classifications.

DN09249151 Issue: 04 © 2018 Nokia 115


   

Appendix: Product conformance statements LTE B31 RRH2x40 (UHAA) Installation Manual

This product is designed to ensure that personnel operating the product are not
endangered by laser radiation during normal operation and fault conditions. This product
does not present a risk of eye injury because it is fully enclosed and does not contain
embedded lasers greater than Class I/1 unless otherwise noted.

f CAUTION! laser
Use of controls or adjustments or performance of procedures other than those specified
herein may result in hazardous laser radiation exposure.
Do not view directly into the laser beam with optical instruments such as a fiber
microscope because viewing of laser emission in excess of Class 1 limits significantly
increases the risk of eye damage.
Never look into the end of an exposed fiber or an open connector as long as the optical
source is switched on.
Ensure that the optical source is switched off before disconnecting optical fiber
connectors.

Packaging collection and recovery requirements


Countries, states, localities, or other jurisdictions may require that systems be
established for the return and/or collection of packaging waste from the consumer, or
other end user, or from the waste stream. Additionally, reuse, recovery, and/or recycling
targets for the return and/or collection of the packaging waste may be established.
For more information regarding collection and recovery of packaging and packaging
waste within specific jurisdictions, please contact the Nokia Services - Environmental
Health and Safety organization. For installations not performed by Nokia Technologies,
please contact the Nokia Customer Support Center at:
Technical Support Services, from all other countries: +1 630 224 4672, prompt 2

Recycling / take-back / disposal of product


Electronic products bearing or referencing the symbol shown below when put on the
market within the European Union, shall be collected and treated at the end of their
useful life, in compliance with applicable European Union and local legislation. They shall
not be disposed of as part of unsorted municipal waste. Due to materials that may be
contained in the product, such as heavy metals or batteries, the environment and human
health may be negatively impacted as a result of inappropriate disposal.

w In the European Union, a solid bar under the crossed-out wheeled bin indicates that the
product was put on the market after 13 August 2005.
Moreover, in compliance with legal requirements and contractual agreements, where
applicable, Nokia will offer to provide for the collection and treatment of Nokia products
bearing the logo at the end of their useful life, or products displaced by Nokia
equipment offers. For information regarding take-back of equipment by Nokia, or for
more information regarding the requirements for recycling/disposal of product, please
contact your Nokia Account Manager or Nokia Takeback Support at:

mailto:takeback@alcatel-lucent.com.

116 © 2018 Nokia DN09249151 Issue: 04


   

LTE B31 RRH2x40 (UHAA) Installation Manual Appendix: Product conformance statements

Material content compliance


European Union (EU) Directive 2002/95/EC, “Restriction of the use of certain Hazardous
Substances” (RoHS), restricts the use of lead, mercury, cadmium, hexavalent chromium,
and certain flame retardants in electrical and electronic equipment. This Directive applies
to electrical and electronic products placed on the EU market after 1 July 2006, with
various exemptions, including an exemption for lead solder in network infrastructure
equipment. Nokia products shipped to the EU after 1 July 2006 comply with the EU
RoHS Directive.

DN09249151 Issue: 04 © 2018 Nokia 117


   

Appendix: Acronyms LTE B31 RRH2x40 (UHAA) Installation Manual

10 Appendix: Acronyms
This appendix lists abbreviations used in this document.

10.1 Acronyms
0-9

4G fourth generation

AISG Antenna Interface Standards Group

ALD Antenna Line Device

AWG AmericanWire Gauge

AWS Advanced Wireless Services

BBU Base Band Unit

BS Base Station

BTS Base Transceiver Station

CCM Channel Control Module

CEM Channel Element Module

CIC Customer Information Center

CPRI Common Public Radio Interface

CSA Canadian Standards Association

d2U digital 2U-height box

DC Direct Current (Power source)

118 © 2018 Nokia DN09249151 Issue: 04


   

LTE B31 RRH2x40 (UHAA) Installation Manual Appendix: Acronyms

DDF Digital Distribution Frame

eCCM enhanced Channel Control Module

eCEM enhanced Channel Element Modem

EMEA Europe, Middle East and Africa

EMC Electromagnetic Compatibility

eNodeB evolved NodeB
( , eNB )

ESD Electrostatic Discharge

ETS European Telecommunications Standards

ETSI European Telecommunications Standards Institute

FDD frequency division duplex

FRU Field Replaceable Unit

GPS Global Positioning System

Hz Hertz

ISO International Standards Organization

LTE Long Term Evolution

LTE Long Term Evolution radio access network
RAN
(,
eUT
RAN
, E-

DN09249151 Issue: 04 © 2018 Nokia 119


   

Appendix: Acronyms LTE B31 RRH2x40 (UHAA) Installation Manual

UTR
AN )

MHz megahertz

MM Multi-mode

NE network element

ODF Optical Distribution Frame

OLCS Online Customer Support

RAN Radio Access Network

RET Remote Electrical Tilt

RETA Remote Electrical Tilt Automatic

RoHS Restriction of Hazardous Substance

RRH Remote Radio Head

Rx Receiver/Receive

SFP Small Form-factor Pluggable

SM Single-Mode (fiber)

TMA Tower Mounted Amplifiers

TRDU Transmit Receive Duplex Unit

Tx Transmit

120 © 2018 Nokia DN09249151 Issue: 04


   

LTE B31 RRH2x40 (UHAA) Installation Manual Appendix: Acronyms

UE user equipment

WAN wide area network

WEEE Waste of Electrical and Electronic Equipment

XMS eXtended Management System