Professional Documents
Culture Documents
Zona 3 Op 2
Description
1
Conservación de alumbrado publico
Zona 3 Op 2
Summary (according to EN 13201:2015)
2
Conservación de alumbrado publico
Zona 3 Op 2
Summary (according to EN 13201:2015)
3
Conservación de alumbrado publico
Zona 3 Op 2
Summary (according to EN 13201:2015)
HELIUS 17500 Lm 140W Street light Luminaire ,Clear Temperad Glass , Gray Body , 4000K (single
side bottom)
Pole distance 40.000 m
4
Conservación de alumbrado publico
Zona 3 Op 2
Summary (according to EN 13201:2015)
TI(2) 15 % ≤ 15 %
A maintenance factor of 0.90 was used for calculating for the installation.
5
Conservación de alumbrado publico
Zona 3 Op 2
Alumbrado publico (M4)
TI(2) 15 % ≤ 15 %
TI(2) 15 % ≤ 15 %
TI(2) 7% ≤ 15 %
6
Conservación de alumbrado publico
Zona 3 Op 2
Alumbrado publico (M4)
m 1.429 4.286 7.143 10.000 12.857 15.714 18.571 21.429 24.286 27.143 30.000 32.857 35.714 38.571
9.167 18.58 16.48 13.85 11.66 10.37 9.75 9.11 9.11 9.75 10.37 11.66 13.85 16.48 18.58
7.500 23.80 20.72 16.78 13.82 12.27 11.17 10.57 10.57 11.17 12.27 13.82 16.78 20.72 23.80
5.833 27.76 23.88 19.08 15.54 13.63 12.30 11.70 11.70 12.30 13.63 15.54 19.08 23.88 27.76
4.167 30.83 26.23 20.71 16.95 14.94 13.44 12.68 12.68 13.44 14.94 16.95 20.71 26.23 30.83
2.500 33.44 28.88 22.98 18.71 16.32 14.45 13.60 13.60 14.45 16.32 18.71 22.98 28.88 33.44
0.833 32.49 29.46 24.35 20.27 17.58 15.44 14.42 14.42 15.44 17.58 20.27 24.35 29.46 32.49
7
Conservación de alumbrado publico
Zona 3 Op 2
Alumbrado publico (M4)
Observer 1: Maintenance value, luminance with dry roadway [cd/m²] (Iso-illuminance curves)
Observer 1: Maintenance value, luminance with dry roadway [cd/m²] (Value grid)
m 1.429 4.286 7.143 10.000 12.857 15.714 18.571 21.429 24.286 27.143 30.000 32.857 35.714 38.571
9.167 0.63 0.57 0.54 0.52 0.54 0.58 0.59 0.60 0.61 0.57 0.55 0.56 0.59 0.63
7.500 0.81 0.75 0.66 0.64 0.69 0.72 0.76 0.76 0.76 0.75 0.72 0.72 0.80 0.84
5.833 0.98 0.93 0.84 0.82 0.89 0.93 1.00 0.99 1.01 1.01 0.96 0.94 0.99 1.01
4.167 1.20 1.17 1.09 1.12 1.24 1.31 1.41 1.44 1.44 1.37 1.25 1.25 1.22 1.23
2.500 1.58 1.60 1.58 1.71 1.98 2.10 2.19 2.17 2.08 1.94 1.69 1.65 1.59 1.54
0.833 1.86 2.00 2.15 2.38 2.72 2.84 2.96 2.93 2.78 2.55 2.24 1.99 1.85 1.78
Observer 1: Maintenance value, luminance with dry roadway [cd/m²] (Value chart)
Observer 1: Maintenance value, luminance with dry 1.28 cd/m² 0.52 cd/m² 2.96 cd/m² 0.41 0.18
roadway
8
Conservación de alumbrado publico
Zona 3 Op 2
Alumbrado publico (M4)
m 1.429 4.286 7.143 10.000 12.857 15.714 18.571 21.429 24.286 27.143 30.000 32.857 35.714 38.571
9.167 0.69 0.63 0.60 0.58 0.60 0.64 0.65 0.67 0.67 0.63 0.61 0.63 0.65 0.70
7.500 0.91 0.83 0.73 0.71 0.77 0.80 0.85 0.84 0.85 0.84 0.80 0.80 0.88 0.93
5.833 1.09 1.03 0.93 0.91 0.99 1.03 1.11 1.10 1.13 1.12 1.06 1.04 1.10 1.12
4.167 1.34 1.30 1.21 1.24 1.37 1.46 1.57 1.60 1.60 1.52 1.38 1.39 1.35 1.37
2.500 1.75 1.78 1.76 1.90 2.20 2.33 2.43 2.41 2.31 2.15 1.87 1.83 1.77 1.71
0.833 2.06 2.22 2.39 2.64 3.02 3.16 3.29 3.25 3.09 2.84 2.48 2.21 2.06 1.98
Observer 1: Luminance with new installation 1.43 cd/m² 0.58 cd/m² 3.29 cd/m² 0.41 0.18
9
Conservación de alumbrado publico
Zona 3 Op 2
Alumbrado publico (M4)
Observer 2: Maintenance value, luminance with dry roadway [cd/m²] (Iso-illuminance curves)
Observer 2: Maintenance value, luminance with dry roadway [cd/m²] (Value grid)
m 1.429 4.286 7.143 10.000 12.857 15.714 18.571 21.429 24.286 27.143 30.000 32.857 35.714 38.571
9.167 0.65 0.60 0.57 0.57 0.59 0.63 0.64 0.65 0.65 0.62 0.59 0.60 0.62 0.66
7.500 0.89 0.84 0.75 0.74 0.79 0.82 0.86 0.85 0.84 0.84 0.80 0.77 0.84 0.88
5.833 1.17 1.14 1.06 1.03 1.12 1.15 1.21 1.20 1.16 1.15 1.07 1.06 1.10 1.13
4.167 1.59 1.58 1.53 1.59 1.80 1.82 1.82 1.77 1.73 1.59 1.43 1.43 1.41 1.43
2.500 1.84 1.97 2.06 2.25 2.56 2.66 2.67 2.57 2.40 2.19 1.93 1.83 1.77 1.77
0.833 1.38 1.50 1.64 1.91 2.34 2.59 2.81 2.85 2.72 2.48 2.14 1.85 1.69 1.60
Observer 2: Maintenance value, luminance with dry roadway [cd/m²] (Value chart)
Observer 2: Maintenance value, luminance with dry 1.41 cd/m² 0.57 cd/m² 2.85 cd/m² 0.40 0.20
roadway
10
Conservación de alumbrado publico
Zona 3 Op 2
Alumbrado publico (M4)
m 1.429 4.286 7.143 10.000 12.857 15.714 18.571 21.429 24.286 27.143 30.000 32.857 35.714 38.571
9.167 0.72 0.67 0.64 0.63 0.65 0.70 0.71 0.72 0.72 0.68 0.65 0.66 0.68 0.73
7.500 0.99 0.93 0.84 0.82 0.88 0.91 0.95 0.95 0.94 0.93 0.89 0.86 0.93 0.98
5.833 1.30 1.27 1.18 1.15 1.24 1.28 1.34 1.33 1.29 1.28 1.19 1.18 1.22 1.25
4.167 1.76 1.76 1.70 1.77 2.00 2.03 2.03 1.97 1.92 1.76 1.58 1.59 1.57 1.59
2.500 2.04 2.19 2.29 2.50 2.84 2.96 2.97 2.86 2.66 2.43 2.15 2.03 1.97 1.96
0.833 1.53 1.67 1.82 2.12 2.60 2.88 3.12 3.17 3.02 2.75 2.38 2.06 1.87 1.78
Observer 2: Luminance with new installation 1.57 cd/m² 0.63 cd/m² 3.17 cd/m² 0.40 0.20
11