You are on page 1of 2

GE

Grid Solutions

GL 310, GL 311
and GL 312
Live Tank Circuit Breakers from 100 kV to 145 kV High Performance
Live tank circuit breakers ensure a high level
The Right Choice for Temperatures Down to -60 °C of reliability every day.
Even under extreme conditions and climates
Live tank circuit breakers for outdoor installation are designed for temperatures down to or in highly active seismic areas customers
-60 °C and feature the latest technologies in interrupter chambers and spring-operated can count on live tank circuit breakers made
mechanisms. For example, the latest double motion technology effectively reduces the by GE.
opening energy by approximately 65 %.

Components Key Benefits


High reliability even in the coldest regions
Interrupter chamber with integral double motion technology and self-blast system
of the world: Down to -40 °C with pure SF6
Pressure relief system for passive protection of substation and personnel Down to -60 °C with gas mixture
Field-proven, temperature-compensated density monitor with two-stage transducer Quick and easy installation and
and three-color dial commissioning
Easy access to the SF6 filling connection (type DILO) Long maintenance intervals
SF6 non-return (check) valve on each pole column g3 capability - green gas for grid with very
Protected opening springs inside each pole column low global warming potential
Hot-dip galvanized steel parts
Mechanism housing made completely of aluminum Quality
Reliable spring-operated mechanism with position indicator clearly visible from outside
The entire development and production
procedures are fully compliant with the latest
Installation and Maintenance ISO 9001, ISO 14001 and OHSAS 18001
Preset at factory before shipping - no adjustments necessary during installation and quality standards. This ensures the high
commissioning quality of our products and services and is
Pole units pre-filled with SF6 at factory before shipping confirmed by regular audits.

Independent disassembly of the interrupter chamber without having to remove the


entire pole column g3 - green gas for grid
Single-pole operated circuit breakers partially pre-assembled before delivery (base GE has pioneered an environmentally friendly
frame with mounted and wired mechanisms) alternative for SF6 gas which reduces the
impact on global warming by more than 99%
Testing compared to SF6.

GE's live tank circuit breakers meet national and international requirement standards. This
has been confirmed by comprehensive type tests according to the latest IEC, GOST and
ANSI standards.

Imagination at work
GL 311/312 F1/4031 P GL 311/312 F3/4031 P
(Dimensions in mm) (Dimensions in mm)

Technical Characteristics Product Options


Spring-operated mechanism/degree of protection: Composite insulators
FK 3/IP 55 More phase center distances available on request
Rated operating sequence: CBWatch3 monitoring system
O-0.3s-CO-3min-CO resp. CO-15s-CO RPH3 controller (F3)
Rated supply voltage:
from 24 V up to 250 V dc/ac

GEGridSolutions.com
For more information, please contact
GE and the GE monogram are trademarks of General Electric Company.
GE Energy Connections
Grid Solutions GE reserves the right to make changes to specifications of products described at any time without
notice and without obligation to notify any person of such changes.

Worldwide Contact Center GL310-312_brochure-EN-2018-07-Grid-AIS-0101. © Copyright 2016, General Electric Company.


All Rights Reserved.
Web: www.GEGridSolutions.com/contact
Phone: +44 (0) 1785 250 070

Imagination at work

You might also like