CALCULATION OF BAR CHAIR

The upper surface ;


Dead Load Coefficient : 1.40 G: 0.00 kN/m2
Live Load Coefficient : 1.60 Q: 2.00 kN/m2

Total Concrete Thickness : h: 450 mm


Cover : c: 70 mm

Bars ;
X axes Diameter : ϕx : ϕ18 mm
Spacing : sx : 200 mm
Y axex Diameter : ϕy : ϕ18 mm
Spacing : sy : 200 mm

Unit Design Load: Pd : 6.21 kN/m2

Bar Chair;
Select Diameter : ϕ8 mm
Elasticity Module : E: 200000 N/m2
Moment of Inertia : I: 201 mm4
Height : hs : 310 mm
Foot Length : As : 300 mm
Distance Between Foots : AAs : 300 mm
Total Length : L: 1520 mm
Effective Height Coefficient : K: 1.00
Reduction Coefficient : ϴ: 0.75
Maximum Buckling Load : Pcr : 4.13 kN
Permissible Buckling Load : ϴ Pcr : 3.10 kN

Selected Diameter Is Not Sufficient.

Required Number of Foot for m2 : 2.00 n: 4 Ad/m2


Required Bar Chair : m2 : 2 Ad/m2

300
ϕ8/ L=152/ Ad=2
310

310

300 300
310
300 300