You are on page 1of 1

Machine Brick

Skimmer WC Sheet Metal Lid 6 x 10 x 21


Athermic Flooring TS
16mm of thickness 1cm
Solaterm brand
WOOD PLANKS 50cm x 53cm border
40 x 40 Ivory color +0.44
3.30 MTS +0.37 8.4 MTS. +0.37 Waterproof Plaster 1:3
Normal Elbow at 90º

0.05 MTS
+0.24
+0.20 in 50mm
Athermic flooring TS parameter beam 13 x 10
Edge of 50cm x 53 cm Bars 4Ø8 to filter
Ivory color ±0.00

0.91MTS.
stirrups1Ø4.2c/15cm

1.06 MTS
1.16 MTS.
Self-Priming Pump

1.26 MTS.
1.22 MTS.
+0.37 +0.37
4.00 MTS Waterproof plaster with Pre-Filter
1:3 for swimming pool at 1 HP

0,17

0.18 MTS.
perimeter beam 20 x 35

1.97 MTS.
1.96 MTS.
±0.00 ±0.00

0.91 MTS
Bars 4Ø10
stirrups 1Ø8 c/15cm -0.68
0.25 MTS toilet WC machine brick

1.25 MTS

MTS.
6 x 10 x 21 Adhesive

0,1
tiles
-0.88 Waterproof -0.89

Perimeter Beam 20 x 35 -1.05

0.18
0,22 Concrete subfloor 1.09 MTS.
bars 4Ø10

2.16 MTS
1.20 MTS
stirrups 1Ø8 c/15cm 0.20 MTS
1.11 MTS.
0.35 MTS

2.50 MTS 0,2 Welded Mesh Q524 Concrete Bottom Drain

0.35
-0.89 Acindar wire T-500 Elaborated -1.45 1.31 MTS.
Longitudinal Wire 1Ø10
plaster Concrete c/15cm -1.60 -1.60
water repellent Elaborated Cross Wire 1Ø10 c/15cm
1:3 -1.80
Adhesive
-1.45 Waterproof
Tiles
-1.60 2.20 MTS.
-1.80
0.15

3.00m 0.50 MTS

Welded Mesh Q524


Acindar wire T-500
Longitudinal Wire 1Ø10
Cleaning concrete 2 POOL LONGITUDINAL SECTION WITH DETAILS 0.55 MTS

c/15cm
Cross Wire 1Ø10 c/15cm S 03 SCALE: NTS.

0.94 MTS
1 POOL CROSS SECTION DETAILS

0.62 MTS
S 03 SCALE: NTS.

0.26 MTS
0.26 MTS

0.26 MTS
0.26 MTS

0.26 MTS
4.80 MTS

0.26 MTS
10mm 0 horizontal bars
every 2 layers of 5'' C.H.B machine brick
sheet metal lid sand filter 6 x 10 x 21
16mm of thickness for swimming pools 1cm mix

0.16 MTS
+0.37 +0.37
0.17 MTS

+0.44 +0.44
0.17

normal elbow at 90º Waterproof plaster 1:3


Normal elbow at 90º in 50mm
±0.00 ±0.00 in 50mm
0.91 MTS

to filter
1.26 MTS

0.55 MTS
±0.00 ±0.00
0.25 0.25
1.42 MTS

1.06 MTS

1.06 MTS
Self-Priming Pump

1.16 MTS

1.16 MTS
Beam - 200mm x 350mm
Self-Priming Pump with Pre-Filter
4 -12mm Ø
4.00m with Pre-Filter for swimming pool at 1 HP
Stirrups 10mm Ø
space @ 15cm for swimming pool at 1 HP
0,24 0,24
-0.89
-0.68 -0.68
-1.05
0.15

0.50 MTS

0,13

0,13
concrete subfloor concrete subfloor
1.30 MTS 1.09 MTS
4.50 MTS

Welded Mesh Q524


1.33 MTS

1.53 MTS
1.11 MTS

1.31 MTS
5 RAILING DETAILS
Acindar wire T-500
Longitudinal Wire 1Ø10
Cleaning concrete
S 03 SCALE: NTS.
c/15cm
Cross Wire 1Ø10 c/15cm
4 WATER PUMP DETAILS
3 POOL STRUCTURAL DETAILS S 03 SCALE: NTS.

S 03 SCALE: NTS.

LOGO: CIVIL ENGINEER : REVISIONS: PROJECT TITLE : SHEET NO. :


PROJECT TITLE: OWNER : SHEET CONTENTS :

PROPOSED TWO-UNITS TWO STOREY VILLA MR & MRS. AARON PAUL A. PERALTA
AS SHOWN
S
PRC NO :
PTR NO :
VALIDITY:
Date:
LOCATION : BGRY. ILI SUR, SAN JUAN, LA UNION SIGNATURE : 03 03
TIN NO. : PLACE ISSUED :