You are on page 1of 1

G E N E R A L N O T E S :

1.0 All dimensions are in millimeters (mm.), otherwise noted.


2.0 Dimensions should not be taken from the drawing scale. Use only the dimension written on
the drawing.
3.0 This drawing has been drafted based on the information from client/ site contractor.
However, it is the client's responsibility to check & verify that the drawings herein have correctly
interpreted the required structuracl dimensions on sites, details, erection sequences and
other pertinent specification as per required and practiced.

SCAFFOLDING LEGEND ON DRAWING:


A.) VERTICAL STANDARDS
The maximum Permissible loading on vertical standards incorporates safety factor on failure of 2.0
Maximum Permissable Loading on Vertical Standards
70
60

Safe Working Load (KN)


50
40

DB1 30
20
10
00
0.00 0.50 1.00 1.50 2.00 2.50 3.00 n/a n/a
Unbraced Length of Vertical Standard
B.) BASEJACK AND UNIVERSAL JACK
DB3 The 57 KN capacity Universal Jack has an adjustment range over 450 mm. It is manufactured from
38 mm. O.D. steel tube with rolled thread. The Jack can be used either at the top (Fork Head) or the
bottom (Base Plate) of the vertical standards.

A 70
60
Tubular Jack Loading Data

Safe Working Load (KN)


50
40

DB1

DB1
30
DB2

20
10
00

t3C 100 200 300


Jack Extension (mm.)
400 500

DB3
DB2

500 MM.
O.C. SPACING
TYPICAL
DB2
DB2

ALD 'M-LOCK' STANDARD

DB1
DB1

400 MM.

O.C. SPACING
500 MM.
max.
ADJUSTABLE BASE JACK

SCAFFOLDING LEGEND ON DRAWING:


DB2

DB1
DB2

24 cmTH
DB1

DB4

DB2

DB1

Cantilever

MAIN CONTRACTOR :
t3C

DB2
DB2

DB2*

CDB1

Middle East Corner


DB1 DB4 for scaffolding &
formwork

DB2
CLIENT/ SITE CONTRACTOR:

3d House
PROJECT:

Hamad Mohamed Villa


DRAWING
TITLE:
SHORING &FORMWORK
Access Scaffolding
PLAN
DRAWN BY: CHECKED BY:
ENG. ABDELRAHMAN ENG. ABDELRAHMAN
DESIGN BY: APPROVED BY:
ENG. ABDELRAHMAN ENG. ABDELRAHMAN
AMAM PROJECT NO: DATE:
5/12/2021

DRAWING NO: REVISION: SHEET NO: SIZE:

01 00 1/1 A1