Report No. GZ11020237-1 Page 2 of 103 Issued: 12-Apr-2011
Guangzhou Monalisa Building Materials Co., Ltd Revised: None
The product covered by this report is a SPA AND SWIM SPA having a rating of 240V, 60Hz, for
indoor and outdoor use, self-contained, power supply cord factory-provided, intended for
Description
installation to permanent wiring system by authorized professional person and connected to a
circuit protected by a recognized ground-fault circuit-interrupter (GFCI).
M-3301, M-3302, M-3303, M-3304 , M-3306, M-3307, M-3308, M-3309, M-3310, M-3311, M-
3312, M-3313, M-3314, M-3314A, M-3315, M-3316, M-3317, M-3318, M-3319, M-3320, M-
3321, M-3321A, M-3322, M-3323, M-3324, M-3325, M-3326, M-3327, M-3328, M-3329, M-
Models
3330, M-3331, M-3332, M-3333, M-3334, M-3335, M-3336, M-3337, M-3338, M-3339, M-3340,
M-3341, M-3342, M-3343, M-3344, M-3345, M-3346, M-3347, M-3348, M-3349, M-3350, M-
3351, M-3352, M-3353, M-3354, M-3356, M-3357, M-3358, M-3359, M-3360
All models, collocated with Jet Pump(s), Blower(s) and Spa Controller(s), are identical except
the differences shown in the following table. For all models, the following requirements shall be
met:
1. Jet Pump(s) shall not be located under Hose, Fitting of Water (air) Jet(s) unless being
baffled.
2. The Spa Controller(s) are provided integral strain relief devices built into the enclosure. The
suitability of the cords routed through these strain relief devices shall be evaluated in Each
Product under a 35-pound pulling.
(type TDA75)
Number of Circulation Pump
(type APW400-2)
Number of Blower
(Rated 200GPM)
Number of Suction Fitting
I)
(type WUA300-I or WUA200-
Number of Jet Pump
WUA200-II)
(type WUA300-II or
Number of Jet Pump
Dimension
Item
Model No. (Length × Width ×
No.
Height mm)
1 M-3301 2200x2100x800 1 1 1 4 0 2
Model Similarity 2 M-3302 2080x2080x880 1 1 1 2 1 0
3 M-3303 3200x2300x970 1 1 1 6 3 0
4 M-3304 2800x2200x980 1 1 1 4 2 0
5 M-3306 2080x2080x960 1 1 1 2 1 0
6 M-3307 3000x2200x980 1 1 1 6 3 0
7 M-3308 2290x2290x980 1 1 1 6 3 0
8 M-3309 2940x1960x980 1 1 1 4 2 0
9 M-3310 2140x2140x910 1 1 1 4 2 0
10 M-3311 2050x2050x970 1 1 1 4 2 0
11 M-3312 2200x2200x970 1 1 1 4 2 0
12 M-3313 2250x2150x970 1 1 1 4 2 0
13 M-3314 2280x2180x970 1 1 1 6 3 0
14 M-3314A 2280x2180x970 1 1 1 6 3 0
15 M-3315 2000x2000x950 1 1 1 4 2 0
16 M-3316 1800x1850x800 1 1 1 4 2 0
17 M-3317 2100x2100x800 1 1 1 4 2 0
18 M-3318 1600x1800x800 1 0 1 2 1 0
19 M-3319 3100x2300x970 1 1 1 6 3 0
20 M-3320 3000x2000x970 1 1 1 6 3 0
21 M-3321 2200x2200x970 1 1 1 6 3 0
22 M-3321A 2200x2200x970 1 1 1 6 3 0
(type APW400-2)
Number of Blower
Controller
Number of Spa
200GPM)
Fitting (Rated
Number of Suction
WUA200-I)
(type WUA300-I or
Number of Jet Pump
WUA200-II)
(type WUA300-II or
Number of Jet Pump
Dimension
Item
Model No. (Length × Width ×
No.
Height mm)
23 M-3322 2300x2200x800 1 1 1 4 2 0
1 1 1 4 2 0
24 M-3323 5700x2200x1200
2 0 1 4 2 0
25 M-3324 2050x2050x970 1 1 1 4 2 0
1 1 1 4 2 0
26 M-3325 7800x2300x1320
1 0 1 4 2 0
2 0 1 4 2 0
27 M-3326 10600x2260x1460
1 0 1 4 2 0
28 M-3327 2200x2200x970 1 1 1 4 2 0
29 M-3328 2460x1960x800 1 1 1 4 2 0
30 M-3329 2200x2200x800 1 1 1 4 2 0
31 M-3330 2150x1850x760 1 1 1 2 1 0
32 M-3331 1840x1230x690 1 1 1 2 1 0
33 M-3332 2100x1520x810 1 1 1 4 2 0
34 M-3333 3200x2200x1150 1 1 1 6 3 0
35 M-3334 2300x2200x970 1 1 1 6 3 0
Model Similarity 36 M-3335 2500x2200x970 1 1 1 6 3 0
(CONT'D) 37 M-3336 1900x1600x840 1 1 1 4 2 0
1 1 1 4 2 0
38 M-3337 4000x2200x1200
1 0 1 4 2 0
39 M-3338 2200x2200x970 1 1 1 4 2 0
40 M-3339 2720x1900x710 1 1 1 4 2 0
41 M-3340 2200x2200x970 1 1 1 6 3 0
42 M-3341 2200x2200x970 1 1 1 6 3 0
43 M-3342 2800x2200x970 1 1 1 6 3 0
44 M-3343 2100x1700x800 1 1 1 4 2 0
45 M-3344 1600x1600x800 1 1 1 2 1 0
46 M-3345 2100x2100x970 1 1 1 4 2 0
47 M-3346 2500x2200x970 1 1 1 6 3 0
48 M-3347 2200x2200x970 1 1 1 6 3 0
49 M-3348 2180x1560x810 1 1 1 2 1 0
50 M-3349 2200x2200x970 1 1 1 6 3 0
1 1 1 4 2 0
51 M-3350 5500x2200x1470
1 0 1 4 2 0
52 M-3351 1830x1830x800 1 1 1 2 1 0
53 M-3352 2000x2000x950 1 1 1 4 2 0
54 M-3353 2000x2000x910 1 1 1 4 2 0
55 M-3354 2200x2200x970 1 1 1 6 3 0
56 M-3356 Ø2290x940 1 1 1 4 2 0
57 M-3357 2200x2200x920 1 0 1 4 2 0
58 M-3358 2000x1660x740 1 1 1 2 1 0
59 M-3359 2800x2200x920 1 0 1 4 2 0
60 M-3360 2000x1150x760 1 0 1 2 1 0
1e
1g
1s
14
03
02
05
1j
1k-1
1r
1i 1l
04
06
13a
Photo 63 - Internal View of model M-3323, also represent the other models
07
1m
15
8a
09 & 10
Photo 65 - Internal View of model M-3323, also represent the other models
One Way Valve for Ozone Generator
11b
11a
11c
1n
1h
8b
8c
8d
13d
13b
13c
LED Lamps
12-1
12-2
12-3
Listed Component - A component part, which has been previously Listed or Certified by an accredited
Certification Organization with no restrictions and is used in the intended application within its ratings.
Unlisted Component - A part that has not been previously evaluated to the appropriate designated component
standard. It may also be a Listed or Recognized component that is being used outside of its evaluated Listing or
component recognition.
Construction Details - For specific construction details, reference should be made to the photographs and
descriptions. All dimensions are approximate unless specified as exact or within a tolerance. In addition to the
specific construction details described in this Report, the following general requirements also apply.
1. Spacings - In primary circuits, minimum spacings are maintained 2.4 mm through air and 3.0 over surfaces
of insulating material between current-carrying parts of opposite polarity and between current-carrying parts
and dead-metal parts.
The spacings between field wiring terminals of opposite polarity or between the field wiring terminal and other
uninsulated metal parts, not of the same polarity, are minimum 6.4 mm through-air and over-surface.
The spacings between a Class 2 circuit and non-Class 2 circuits, and accessible metal, and grounded metal
shall not be less than 2.4 mm.
2. Mechanical Assembly - Components such as switches, connectors, wiring terminals and display lamps are
reliably mounted and prevented from shifting or rotating by lock washers, star washers, or the mounting
format. The lowest portion of any live part in a hot tub or spa shall be at least 102 mm above the
surface on which the unit will ultimately be installed.
3. Corrosion Protection - All ferrous metal parts are protected against corrosion by painting, plating or the
equivalent.
4. Grounding - All exposed dead-metal parts and all dead-metal parts within the enclosure that are exposed to
contact during any servicing operation are to be connected to the grounding lead of the power supply cord.
5. Internal Wiring - Internal wiring is reliably routed away from sharp or moving parts. Internal wiring leads
terminating in soldered connections are made mechanically secure prior to soldering. Recognized separable
(quick disconnect) connectors of the positive detent type, closed loop connectors, or other types specifically
described in the text of this report are also acceptable as internal wiring terminals. At points where internal
wiring passes through metal walls or partitions, the wiring insulation is protected against abrasion or damage
by plastic bushings or grommets. An open-end space lug shall not be used unless means are provided to
hold the lug in place when the wire-binding screw or nut becomes slightly loose. Upturned ends on the tang
of the lug or a retaining barrier may be used to hold the lug in place.
6. Accessibility of Live Parts - All uninsulated live parts in primary circuitry are housed within a metal or plastic
enclosure constructed with no openings other than those specifically described in the construction details.
Each splice, each connector, and each terminal connection shall be located within an enclosure.
7. Wiring Between Component Enclosure - Wiring Between Component Enclosure shall be SEW, SEOW,
SJW, SJOW, SJEW, SJEOW, SJTW, SJTOW, SOW, STW, or STOW, rated min. 60ºC. Strain relief shall be
provided.
7.0 Illustrations
Monalisa CONFORMS TO UL
STD. 1563 &
CERTIFIED TO
SPA AND SWIM SPA
MODEL: M-3323 CSA STD. C22.2
No. 218.1
240Vac, 60Hz, 48 A (Spa Tub)
RATING:
240Vac, 60Hz, 48 A (Swim Pool) CSA Enclosure 3
FLOW Max. 188 GPM (Spa Tub)
RATE: Max. 188 GPM (Swim Pool) 4002833 Date Code: MM YY
Monalisa CONFORMS TO UL
STD. 1563 &
CERTIFIED TO
SPA AND SWIM SPA
CSA STD. C22.2
MODEL: M-3301
No. 218.1
RATING: 240Vac, 60Hz, 48 A
CSA Enclosure 3
FLOW
RATE:
Max. 188 GPM 4002833 Date Code: MM YY
SUPPLY 4 wire (including grounding wire), intended for connection to 60 A Supply
CORD: Circuit Overcurrent Protector.
FOR INDOOR AND OUTDOOR USE
Alteraive for models except models M-3301, M-3323, M-3325, M-3326, M-3337and
M-3350
7.0 Illustrations
Illustration 1 - Marking Label
WARNING
Note:
1. The Marking labels of all models are identical except type designation and electric rating. For the electric rating
on Marking label, refer to Sec. 2.0 for details.
2. Date code "MMYY" stands for month and year of manufacturing.
3. "REDUCE THE RISK OF ELECTROCUTION", "REDUCE THE RISK OF CHILD DROWING", "REDUCE THE
RISK OF OVERHEATING" and "WHEN PREGNANT", the letterings shall be marked and not be less than 4.8
mm in height.
4. Other lettering shall be marked and not be less than 3.2 mm in height.
5. The ETL logo shall not be less than 8 mm in width and 8mm in height, and the "C" and "US" shall not be less
than 2mm in height. The control No "4002833" and "CONFORMS TO UL STD. 1563", "CERTIFIED TO CSA
STD. C22.2 NO. 218.1", the letter height shall not be less than 1.5 mm in height.
7.0 Illustrations
Illustration 1 - Marking Label
Labeled together with marking label, for product sold to CSA market
AVERTISSEMENT
7.0 Illustrations
Illustration 1 - Marking Label
Labeled inside the Spa and beside Spa Controller for models M-3323, M-3325, M-3326, M-3337and M-3350
WARNING
PREVENT ELECTROCUTION
DISCONNECT ALL SUPPLY CONNECTIONS BEFORE SERVICING
THIS APPLIANCE HAS 2 SUPPLY CONNECTION
Remark: Signal Word – Black Lettering/Orange Background
Safety Alert Symbol – Black Triangle/Orange Exclamation Point
Labeled inside the Spa and beside Spa Controller for models M-3323, M-3325, M-3326, M-3337and M-
3350, for product sold to CSA market
AVERTISSEMENT
PREVENT ELECTROCUTION
DEBRANCHER TOUTES LES CONNEXIONS ALIMENTATION AVANT DE
CET APPAREIL A CONNEXION D'ALIMENTATION 2
Remark: Signal Word – Black Lettering/Orange Background
Safety Alert Symbol – Black Triangle/Orange Exclamation Point
Note:
1. One marking may be provided if visible from all supply connection points;
2. "WARNING" shall be marked and the lettering not be less than 6.4 mm in height;
3. "PREVENT ELECTROCUTION" shall be marked and not be less than 4.8 mm in height; and
4. "DISCONNECT ALL SUPPLY CONNECTIONS BEFORE SERVICING", "THIS APPLIANCE HAS 2 SUPPLY
CONNECTION", the lettering shall be marked and the lettering not be less than 3.2 mm in height.
7.0 Illustrations
Illustration 2 - Wiring Diagram
Labeled on the internal surface of Spa Controller
7.0 Illustrations
Illustration 2 - Wiring Diagram
Note:
1. The Wiring Diagram shall be marked;
2. "Use copper conductors only" & "EMPLOYER UNIQUEMENT DES CONDECTEURS DE CUIVRE.", "#6 AWG
min. wire=90℃" & "TORQUE RANGE FOR TBL´27-30 IN. LBS", "For supply connections, use conductors sized
on the basis of 60℃ ampacity but rated minimum 90℃", "a disconnecting means must be installed within sight
from the equipment and at least 5 feet (1.52 m) from the inside walls of the pool, spa, or hot tub" and "CAUTION:
CONNECT ONLY TO A CIRCUIT PROTECTED BY A CLASS A GROUND FAULT CIRCUIT INTERRUPTER &
ATTENTION: CONNECTER UNIQUEMENT À UN CIRCUIT PROTÉGÉ PAR UN DISJONCTEUR
DIFFERENTIAL DE CLASSE A.", the lettering on on the internal surface of Spa Controller shall be marked and
not be less than 3.2 mm in height; and
3. "WARNING" shall be marked and the lettering not be less than 9.5 mm in height.
7.0 Illustrations
Illustration 3 - Temporary Marking on Bathtub
7.0 Illustrations
Illustration 3 - Temporary Marking on Bathtub
WARNING
WHEN PREGNANT, soaking in hot water for long period can harm your fetus. Measure
water temperature before entering.
1. Do not enter spa if water is hotter than 100℉(38℃).
2. Do not stay in spa for longer than 10 minutes.
This marking is to be removed only by the owner after safety sign is installed.
Remark: Signal Word – Black Lettering/Orange Background
Safety Alert Symbol – Black Triangle/Orange Exclamation Point
Note:
1. These markings are on a removable adhesive-backed label and shall be readily visible after installation;
2. "WARNING" & "AVERTISSEMENT" shall be marked and the lettering not be less than 12.7 mm in height;
3. "REDUCE THE RISK OF ELECTROCUTION", "REDUCE THE RISK OF CHILD DROWING", "REDUCE THE
RISK OF OVERHEATING" and "WHEN PREGNANT", the letterings shall be marked and not be less than 4.8
mm in height; and
4. All other lettering not mention above shall be marked and the lettering not be less than 3.2 mm in height.
7.0 Illustrations
Illustration 3 - Temporary Marking on Bathtub
Labeled together with marking label, for product sold to CSA market
AVERTISSEMENT
7.0 Illustrations
Illustration 4 - Instruction Manual
7.0 Illustrations
Illustration 4 - Instruction Manual
7.0 Illustrations
Illustration 4 - Instruction Manual
7.0 Illustrations
Illustration 4 - Instruction Manual
7.0 Illustrations
Illustration 4 - Instruction Manual
7.0 Illustrations
Illustration 4 - Instruction Manual
7.0 Illustrations
Illustration 4 - Instruction Manual
7.0 Illustrations
Illustration 5 - Circuit Diagram and PCB Layout of LED Controller
COMPONENTS
Components used shall be those itemized in this Intertek report covering the product, including any amendments
LISTING MARK
The ETL Listing mark applied to the products shall either be separable in form, such as labels purchased from
Intertek, or on a product nameplate or other media only as specifically authorized by Intertek. Use of the mark is
FOLLOW‑UP SERVICE
Periodic unannounced audits of the manufacturing facility (and any locations authorized to apply the mark) shall
be scheduled by Intertek. An audit report shall be issued after each visit. Special attention will be given to the
In the event that the Intertek representative identifies non-conformance(s) to any provision of this Report, the
Applicant shall take one or more of the following actions:
Note to Intertek Follow Up Inspector: The Component Evaluation Center, CEC, will notify you in writing
when these components must be selected and sent to the CEC for re-evaluation
Required Tests
- Dielectric Voltage Withstand Test
- Grounding Continuity Tests
Test Equipment
The test equipment is to include a transformer having a sinusoidal output, a means of indicating the test potential,
an audible or visual indicator of electrical breakdown, and either a manually reset device to restore the equipment
after electrical breakdown or an automatic feature to reject any product that does not meet the requirement.
When the output of the test-equipment transformer is less than 500 volt-amperes, the equipment is to include the
voltmeter in the output circuit to directly indicate the test potential.
When the output of the test-equipment transformer is 500 volt-amperes or more, the test potential is able to be
indicated by a voltmeter in the primary circuit or in a tertiary-winding circuit, a selector switch marked to indicate
the test potential, or in the case of equipment having a single test-potential output, a marking shall be visible
while the equipment is in use to indicate the test potential. When marking is used without an indicating voltmeter,
the equipment shall include a positive means, such as an indicator lamp, to indicate that the manually reset
switch has been reset following a dielectric breakdown.