Professional Documents
Culture Documents
S M 177 HD
STM D
D
DVB-S2+
+T2/C Co
ompact Meter
U Mannual
User
R 0145131R
Ref R13
CAHORS Digiital– CS 60022
www.groupe-ccahors.com
User`s Manual
DVB
B COMBO MET
TER
5. Sattellite.......................................................................................................................................................................................... 5
6. Terrrestrial .................................................................................................................................................................................... 13
6. 3 Spectrum Chart
C ............................................................................................................................................................. 14
7. Cable TV ..................................................................................................................................................................................... 15
9. Acccessories ................................................................................................................................................................................. 16
without notice.
• Before usingg the first time, please
p charge the
t battery for 3 hours.
•Please use thhe special adappter for chargingg attached with the meter, do not
n use it for
other productt
• In case of anny technical queestions, please contact your loocal dealer.
1/19
CAHORS Dig
gital– CS 60022
www.groupe--cahors.com
User`s Manual
1. MAIN FEAATURES
z Support DVB-S/DVB-S2
D 2/DVB-T/DVB-T
T2/DVB-C
z LNB shorrt-circuit protecttion and indicattor.
z Extremely fast and accuurate with high sensitivity.
s
z 320*240 color LCD dispplay with controlllable back lightt.
z Databasee editable by usser easily.
z Signal locck audible notiffication: on/off.
z Firmwaree can be upgradded by USB port.
z Databasee can be editedd on PC and dow
wnloaded by USB port.
z Power-suupply100-240V//50/60Hz 12V, 1000Am.
z Ultra-longg standby, low power consumpption.
z Fast charrging Li-ion batttery can last around 3 hoursDV
VB-S/S2
z Real timee Spectrum-Anaalyzer and transsponder messaage detected
z Constellaation diagram with
w 8PSK, QPS
SK, 16APSK, 322APSK.
z Angle calculation of azim
muth and elevation.
z Azimuth and
a elevation measurement.
m
z Satellite alignment
a systeem.
z Power, C/N,
C BER, Moduulation mode dissplay.
z DisEqC1.0, DisEqC1.2 and
a USALS suppported.
z Auto DisE
EqC identificatioon for DisEqC11.0
z SCR/SCD
D2 supported.
z Cable ideentification for Quattro
Q LNB eaasilyDVB-T/T2
z Power, VBER,
V SNR andd CBER displayy.
z Spectrum
m analyzer
z SCOPE Display
D
z Channel Auto ScanDVB
B-C
z DVB-C(Q
QAM) : Power, CBER,
C PBER, SNR
S and Symbbol Rate displayy
z Spectrum
m analyzer
z Tilt Displaay
2/19
CAHORS Dig
gital– CS 60022
www.groupe--cahors.com
User`s Manual
1. LNB INPUT: Signal input poort, connects dirrectly to antennna using coaxial cable.
2. Antenna Inpu
ut: Signal input poort for DVB-T annd DVB-C. Connnect directly to Antenna using
coaxial cable
3. Charge Light:
Red: the batterry is being charrged.
www.groupe--cahors.com
User`s Manual
F3: Enter to TP
P control menu in Satellite Meaasure menu
F4: Enter to Auuto DiSEqC function in Satellitee Measure mennu
7. Navigation Keys:
/:Move foocus or change value.
/: Move foocus or changee value
8. MENU: Go into main menu
m or exit from
m the current menu
m
9. OK: Confirrm
100. : Turn the meterr on/off, press and
a hold for 2 seeconds to poweer on
the meter.
111. Charging: Connect with thhe charger cordd for charging thhe equipment.
3. HOW TO MEASURE
M
Poweer on the meterr, select the sysstem to measuree or select systtem setting to set parameters ffor the device inn the
HOM
ME menu.
In all menus, press [/] button to navigate, preess [/] buttton to change the
t value of foccused item, presss
NU] button to enter
[OK] button to confirrm your select, edit value or ennter a list to select a wanted iteem, press [MEN
or exxit menus.
www.groupe--cahors.com
User`s Manual
3. Analyze the TILT in TILT menu and the spectrum in Spectrrum Chart menu.
4. HOME MENNU
The meter
m will enterr this menu firstt during power on.
o Press [/
]
to sw
witch items or [O
OK] to enter subbmenus.
Terrestrial: Subm
menu for DVB-T/T2 system.
System Settin
ng: Submenu foor system param
meters setting. Such as languaage, auto
power off and so on.
5. SATELLITEE
The submenu
s for DV
VB-S/S2 functioons. User can read
r the parameters of the livee signal, analyzze the spectrum
m chart,
get thhe constellationn chart, calculatte the angles foor a special sateellite or edit the parameters of satellites.
z 036.0°E
E Eutelsat 36: The curreent satellite. Preess [/] to switch
s betweenn satellites
and press [OK]] to enter satellite list to select satellite. Presss [OK]
buttonn to select the focused
f satellitee and press [ME
ENU] to exit
5/19
CAHORS Dig
gital– CS 60022
www.groupe--cahors.com
User`s Manual
z 12322/V
V/27500: The current traansponder. Presss [/] to sw
witch between
transpponders and preess [OK] to entter edit. Press [/] to
move cursee and [/] too change value of each focuseed item in edit m
menu.
z 13V: The power parameter off the LNB. Presss [/] buttoon to
switch beetween Auto, Off,
O 13v and 18v.
1
z 042.0°E The current sattellite. Press [/] to switch between satelliites and press [OK]
E Turksat3/4A:T [
to enter satellite list to select
s satellite. Press [OK] buttton to select the focused satellite and press
[MENU] to exit from editmenu. All the other parameteers on the menuu will be refreshhed according to the
selectedd satellite.
z 11096/H
H/30000: The current
c transponnder. Press [/] to switch between
b
transponders and preess [OK] to enteer edit. Presss [/]
to move curse annd [/] to chhange value of each focuused item
in edit menu.
m
z UNIVER
RSAL: The LNB
B type. Press [
/] to switch between LNB ttypes and
press [OK] to enter
e list to seleect type.
6/19
CAHORS Dig
gital– CS 60022
www.groupe--cahors.com
User`s Manual
z Pwr: The power parameter off the LNB. Presss [/] buttoon to
switch betweenn Auto, Off, 13vv and 18v.
z None: The Diseeqc port setting for Diseqc 1.0 and 1.1. Press [/]
buttonn to switch betw
weenports or prress [OK]buttonn to select
poort in the list.
z My Long
gitude: The longitude of
o local. Press [OK]
[ to enter eddit mode, then
press [/] to change the value and
a [/] to move
m curse.
Press [OK] again to exit eddit mode
z My Latittude: The latituude of local. Preess [OK] to enteer edit mode, thhen
press [/] to change the value and
a [/] to move
m curse.
Press [OK] again to exit eddit mode
z o center:
Move to Press [OK] to move
m the dish to
t central positioon.
z Move to
o position: Press [OK] to confirm too move to settinng position
z Move siingle step: Move thee motor by step. Press [/]] to move to weest or east
7/19
CAHORS Dig
gital– CS 60022
www.groupe--cahors.com
User`s Manual
z Move in
ncessantly: Move thee motor incessaantly. Press [/] to move too west or
east
z o centre:
Move to Press [OK] to move
m to centre point
z Save an
nd Commit: Press [OK] to save curreent position
Presss [/] buttonns to move cursse in list and prress [OK] buttonn to
edit.
Presss [OK] button too edit the namee or the orbit position of current
satellite in the dialogg. And then preess [/] to move
m curse and
[/
] to change value
v of each foocused item in edit
e menu.
Presss [F3] to add neew transponderr. Press [F4] to enter delete diialog,
presss [OK] to confirm
m to delete or press
p [MENU] too cancel. And
presss [OK] button too edit selected transponder.
t Annd then press
[/] to move currse and [/]] to change valuue of each focused
item in edit menu.
8/19
CAHORS Dig
gital– CS 60022
www.groupe--cahors.com
User`s Manual
5.4.. SPECTRUM
M CHART
z --V: Show
w the RF power output status. The
T values are:: 13V, 18V and OFF(--V)
z : The current
c frequenccy curse, press [/] to set the
t current freqquency.
Presss [/] to sw
witch between LNB types.
Presss [OK] button too check whetheer the current freequency can bee
lockeed or not. A dialog will show thee locked transpponder once it
lockss.
5.5.. CONSTELLLATION
Movee the curse to Constellation
C icoon and press OK to select
satellite and transpoonder for consteellation analyzeer. See the figurre
below
w:
z H/30000:
11096/H The current traansponder, presss [/] to sw
witch between
transpponders
9/19
CAHORS Dig
gital– CS 60022
www.groupe--cahors.com
User`s Manual
The CNR,
C Power levvel and constellation chart will be showed on the
menuu. Press [OK] too refresh.
○
1 . Thhe current elevaation simulatedd by meter
○
2 . Thhe right elevatioon calculated by meter
○
3 . Thhe current azim
muth simulated by
b meter
○
4 . Thhe right azimuthh calculated byy meter
User need to adjust the attitude of the meter accoording to the sim
mulated results until the currennt simulated values
very close to the right ones. As close as possible. Then the BLUE lines will turn GREEN. Below
wing is the grapph for
meteer during adjust..
10/19
CAHORS Dig
gital– CS 60022
www.groupe--cahors.com
User`s Manual
Selecct Align and preess [OK] to gotoo alignation menu. User can siimulate the anteenna right posittion more directtly on
this menu.
m And the menu
m as folowing screen shott.
User need to adjust the attitude of the meter accoording BLUE arrraw
on thhe screen. The meter
m will deepp and the RED icon turns to
GREEN if the RED icon closes to the
t YELLOW onne. It is better too
makee the two icon overlapping.
o And also values of
o azimuth and
elevaation will refreshh on time accorrding to the currrent position
durinng the whole proocess.
11/19
CAHORS Dig
gital– CS 60022
www.groupe--cahors.com
User`s Manual
5.7 TP CONTRO
OL
TP Control
C is short for
f transponderr control. Press [F3] in Satellitee
Meassure menu to ennter this menu. It is very easy and useful to
NB . Press [MENU]
check the output staatus of each poort of Quattro LN
to exxit to Finder mennu. Please see the figure on thhe right side:
12/19
CAHORS Dig
gital– CS 60022
www.groupe--cahors.com
User`s Manual
6. TERRESTRRIAL
MENUS: MEASURE
SUBM E, AUTO SCAN, SPECTRUM CHAR
RT, SCOPE, RF
6. 1 TERRESTRIAL MEASURRE
The device
d will show
w SNR, CBER, VBER, power value,
v strength
and quality
q of the coonnected live signal. Please seee below for
detail.
z : The loock status. The signal is lockinng if the icon is green or the coolor of
the icon is red.
r
13/19
CAHORS Dig
gital– CS 60022
www.groupe--cahors.com
User`s Manual
6. 3 SPECTRUM
M CHART
This menu shows thhe spectrum chaart of the setting frequency rannge.
Pleasse see below sccreenshot.
z : The curse
c of the currrent frequency. Press [/] to change the vvalue.
z S: The start
s frequency of
o the spectrum
m chart.
z E: The end
e frequency of
o the spectrum chart.
6.4 SCOPE
This screen show 6 channels levell (dBuV) in one page, use [//]
to moove focus on chhannel number and press [OK]] change channnel
numbber.
6.6 SETTING
User can enable/dissable the powerr supply for anteenna. 5V and 12V output are supported.
s And also user can set to
scan DVB-T, DVB-T
T2 and both of them during Autto Scan.
14/19
CAHORS Dig
gital– CS 60022
www.groupe--cahors.com
User`s Manual
7. CABLE TV
V
User can measure DVB-C
D live signnal in this submenu. There aree
total three submenuus: Cable Measure, Tilt and Sppectrum chart.
z : The loock status. The signal is lockinng if the icon is green otherwise the
colorof the icon is red.
z R:
POWER The power
p level valuue of the live siggnal.
7.2 TILT
This menu shows tillt of three channnels` power levvel.
z C16,C177, C18: The channel nuumber. Press [/] to switchh between them
m. Press
[/] to change
c the chaannel number and
a press [OK] to
t pop out the
channel list to select.
www.groupe--cahors.com
User`s Manual
8. SYSTEM SETTING
z Beep: The beep statuus during pressing keys or wheen the signal is locking.
►] to turn on orr turn off beep.
Press [◄/►
z Auto Standby: Set thhe time for meteer to enter standdby mode automatically. Presss
◄/►] to switch between Off, 10 min, 20 min, 30 min and 60 min.
[◄
9. ACCESSORIES
Poweer adapter, 2 RF connector, 1 CD for user maanual.
16/19
CAHORS Dig
gital– CS 60022
www.groupe--cahors.com
User`s Manual
17/19
CAHORS Dig
gital– CS 60022
www.groupe--cahors.com
User`s Manual
Min.leevel in 35dB
BuV(noise)
Max.level in 90dB
BuV
LNB Power
P and Pol Verticcal 13V, Horizontal 18V, 300mA
A
Bandw
width C/Kuu-band Selectabble
Edit TP
T Frequuency, Symbol Rate, Polarity(9950~2150MHz)
18/19
CAHORS Dig
gital– CS 60022
www.groupe--cahors.com
User`s Manual
DVB-T/T2
Identtification DV
VB-T DVB-T2
Carriers 2kk, 4k, 8k 1k, 2k, 4kk, 8k, 8k+E, 16kk, 16k+EXT,
32k,32k++EXT
Guarrd Interval 1//4, 1/8, 1/16, 1/332 1/4, 19/2556, 1/8, 19/128, 1/16, 1/32, 1/1128
Codee Rate 1//2, 2/3, 3/4, 5/6, 7/8 1/2, 3/5, 2/3,
2 3/4, 4/5, 5//6
Moduulation QPSK,16-QAM,664-QAM QPSK, 166QAM, 64QAM
M, 256QAM
Banddwidth 6, 7 and 8 MHz 6,7 and 8 MHz
PLP Mode ------ Single / Multiple
M
PLP ID ------ 0-255
Specctrum Analyzer Display waveform
ms of selected frrequencies
DVB-C
Identtification DVB--C
QAM
M mode 16 / 32
3 / 64 / 128 / 256
2 QAM
SNR 20dB
B ~ 40dB, + 2dB
B
19/19
CAHORS Dig
gital– CS 60022
www.groupe--cahors.com