You are on page 1of 15

4.3 4.

4.3 4.B

4.09
021
4.09
025
4.09
034

4.09

+29.33 022

4.09
026
A

4.09
033

4.09
027
4.09
036
CEILING

4.C

KEY PLAN
INTERCOM SCALE = N.T.S

200 158
138

2400
1400

+26.17

DRAWING TITLE

ELEVATION - A TYPE B1a - ELEVATION AT ENTRY - INTERCOM


BUILDING NO LEVEL ROOM NO.

B4 L 09 026
DATE/TIME SCALE DRAWN BY

01/09/2017 5:41:39 PM 1:20 @ A3 DCLK


SHORT TOWEL BAR
(400mm LONG)

sh gu

DROP
20mm LEVEL
WALL MOUNTED

400
HOOKS

LONG TOWEL BAR 200


500
(660mm LONG)

SLOPE

G
20mm LEVEL
DROP

90
GEBERIT LINEAR SHOWER

300
WATER HEATER CHANNEL
sh gu

SLOPE

1100

1100
950
4.C

PROPOSED FLOOR PLAN


PROPOSED ELEVATION A

DRAWING TITLE

TYPE B1a BATHROOM PLAN & ELEVATION A


BUILDING NO LEVEL ROOM NO.

B4 L09 033
DATE/TIME SCALE DRAWN BY

11/09/2017 10:23:51 AM 1:20 @ A3 SB


OUTLET / SWITCH LEGEND:
POWER OUTLETS DATA OULETS:

EQUIPMENT: ds = data socket (RJ45)


4.3 wm = washing machine ts = TV socket (RF)
dwm = dishwasher machine
mw = microwave SWITCH TYPES
op = oven
ef = exhaust fan SPECIFIC EQUIPMENT:
ci = cooker ignition GV = gas valve
r = refrigerator OP = oven
LS = ceiling light + cabinet light
GENERAL USE (gu): cf = ceiling fan
gu = general use fcu = fan coil unit
cf ls ml = medium level
gu vec = water/gas cut off valve
hl = high level ps = pendent sprinkler head
wh= water heater
r td = termavelocimetric detector

wm

ci
R

dwm
ef
D

op

gu

gu

mw

4.C

A B
DRAWING TITLE

TYPE B1a KITCHEN - FLOOR PLAN


BUILDING NO LEVEL ROOM NO.

B4 L9 027
DATE/TIME SCALE DRAWN BY

9/18/2017 12:34:02 PM 1:20 @ A3 SB 1


CEILING LEGEND:
AFL: 2.40 HEIGHT ABOVE FINISHED
FLOOR (2.40m)

LIGHTING ON CEILING
4.3 SPRINKLER

TERMOVELOCIMETRIC
VENTILATION GRILL DETECTOR
ON THE CEILING
LED SURFACE LIGHT MOUNTED
UNDERSIDE OF WALL HUNG
CUPBOARDS

597
CEILING LIGHTING

FAN
522

326
1450

500
1450
300

450

AFL: 2.70

AFL: 2.40
450

SURFACE LIGHTING

4.C

DRAWING TITLE

TYPE B1a KITCHEN - CEILING PLAN


BUILDING NO LEVEL ROOM NO.

B4 L9 027
DATE/TIME SCALE DRAWN BY

9/18/2017 12:35:45 PM 1:20 @ A3 SB 2


4.C

1150
150
dwm wm gu

mw
gu
BACK
SPLASH

1200

1200
900
dwm wm

600

300

DRAWING TITLE

TYPE B1a KITCHEN - SECTION A


BUILDING NO LEVEL ROOM NO.

B4 L9 027
DATE/TIME SCALE DRAWN BY

9/18/2017 12:36:40 PM 1:20 @ A3 SB 3


4.C

900
ef

ACK ACK
SH B SH B
SPLA SPLA
835 gu

600
S/S BACK

OPEN CLOSE OPEN CLOSE


300

R OP GV
450

ci 900
r

290
op 600
800
300

GAS DETECTOR

DRAWING TITLE

TYPE B1a KITCHEN - SECTION B


BUILDING NO LEVEL ROOM NO.

B4 L9 027
DATE/TIME SCALE DRAWN BY

9/18/2017 12:37:48 PM 1:20 @ A3 SB 4


4.3

960

1150
1100
540

BACK
SPLASH

mw

300

1050
900

600
600

DRAWING TITLE

TYPE B1a KITCHEN - SECTION C


BUILDING NO LEVEL ROOM NO.

B4 L9 027
DATE/TIME SCALE DRAWN BY

9/18/2017 12:38:19 PM 1:20 @ A3 SB 5


4.3

1150

cf ls

100
1200
1050

r
wm

300

DRAWING TITLE

TYPE B1a KITCHEN - SECTION - D


BUILDING NO LEVEL ROOM NO.

B4 L9 027
DATE/TIME SCALE DRAWN BY

9/18/2017 12:38:46 PM 1:20 @ A3 SB 6


4.3 4.4
7.95 POWER OUTLETS, SWITCHES & EQUIPMENT

wm = washing machine : Socket 0.30, Switch 1.20


dwm = dishwasher machine : Socket 0.30, Switch 1.20
op = oven : Socket 0.30, Switch 1.20
4.B
fcu
r = refrigerator : Socket 0.30, Switch 1.20
ll
4.09 4.09
fcu = fan coil unit : Socket / Switch 1.70
4.09 BALCONY
021 025 034 mw = microwave : Socket / Switch 1.20
ml ef = exhaust fan : Socket / Switch 1.20

2
ll ci = cooker ignition : Socket / Switch 1.20
MASTER BEDROOM
wh= water heater : Socket / Switch 1.20

4.09 ll

2
022 ll = low level - 0.30
ll

2
ml = medium level - 0.95
BEDROOM gu = general use - 1.20

ml hl = high level - 1.70

2
ll CF
ll CF
ll
OUTLETS & EQUIPMENT
a
ll ll
7.90

4.09 13a single, switched recessed socket outlet.


026
a
2 13a twin, switched recessed socket outlet.
LIVING a
SH SH
gu 4.09 4.09
CF 033 Switched fused connection unit.
gu 036 gu
4.09 r
027
a
wm
13a single, unswitched fused recessed socket outlet.
KITCHEN ci
BATHROOM
SH Shaver outlet 115/230V - to be installed at
dwm
MASTER BATHROOM no less than 0,60m from taps
ef

op
wh

mw gu LIGHTING
ll CF
gu CF
2 Ceiling fan switch

One -way, 1 gang, 10A, recessed lighting switch


4.C
One -way, 2 gang, 10A, recessed lighting switch

Two -way, 1 gang, 10A, recessed lighting switch

Two -way, 2 gang, 10A, recessed lighting switch

TELECOMUNICATIONS SYSTEM NOTE:


Single data embedded socket (1xRJ45), mounted at h=0,3m . when coupled with a TV (RF) socket, All switches to be installed horizontzlly 1.2 meters from finished floor.
it should be mouted at the same height as the later
Refer to kitchen elevations for outlet and switch location
Dual data embedded sockets (2xRJ45), mounted at h=0,3m
DRAWING TITLE
Single TV (RF) embedded socket, mounted at h=0,3m
TYPE B1a - FLOOR PLAN WITH ELECTRICAL
Dual OS2 SC/APC embedded socket, mounted at h=0,3m,
BUILDING NO LEVEL ROOM NO.

Distribution board
B4 L 09
Intercom, mounted 1.4 meter from finished floor DATE/TIME SCALE DRAWN BY

11/9/2017 8:16:47 AM 1:50 @ A3 SB


4.3 4.4

4.B
4.09 4.09
4.09 025 034
021 BEDROOM MASTER BEDROOM
BALCONY

4.09
022
LIVING ROOM

4.09
026
HALLWAY

4.09
F
027 4.09
KITCHEN 033
BATHROOM
4.09
036
BATHROOM

4.C

DRAWING TITLE

TYPE B1a - FLOOR PLAN


BUILDING NO LEVEL ROOM NO.

B4 L09
DATE/TIME SCALE DRAWN BY

11/9/2017 8:14:10 AM 1:50 @ A3 SB


4.3 4.4

4.B 4.09
4.09
025
4.09 034
BEDROOM
021 MASTER BEDROOM
BALCONY

4.09
022
LIVING ROOM

4.09
026
HALLWAY

F 4.09
033
4.09 BATHROOM
4.09
027 036
KITCHEN BATHROOM

4.C

DRAWING TITLE

TYPE B1a - FURNITURE PLAN


BUILDING NO LEVEL ROOM NO.

B4 L09
DATE/TIME SCALE DRAWN BY

11/9/2017 8:18:46 AM 1:50 @ A3 SB


LONG TOWEL BAR
(660mm LONG)
4.4
BACK TO WALL TUB SHORT TOWEL BAR
(1500X805) (400mm LONG)
4.4

sh gu

DROP
20mm LEVEL
1750

SLOPE
G

90
800
sh gu
SLOPE

20mm LEVEL
DROP
900

WALL MOUNTED
HOOKS

1100

1100
475 200

4.C

GEBERIT LINEAR SHOWER


CHANNEL
ELEVATION - A
PROPOSED FLOOR PLAN

DRAWING TITLE

LEGEND TYPE B1a BATHROOM - ELEVATION - A


BUILDING NO LEVEL ROOM NO.

gu = general use B4 L 09 036


sh = shaver outlet
DATE/TIME SCALE DRAWN BY

11/9/2017 11:33:47 AM 1:20 @ A3 SB


LEGEND

AFL 2.40 HEIGHT ABOVE FINISHED FLOOR (2.40m)

DOWN LIGHT

LIGHTING ON CEILING
4.3 4.4
SURFACE LIGHT

SPRINKLER

TERMOVELOCIMETRIC DETECTOR

EXTERIOR WALL LIGHT

4.B
4.09 INTERIOR WALL LIGHT
021 AFL: 2.40 AFL: 2.40
4.09 AFL: 2.78 4.09 AFL: 2.78 FAN POINT
025 034

TERMOVELOCIMETRIC
DETECTOR
HVAC EQUIPMENT

4.09 HVAC EQUIPMENT


022 AFL: 2.40
PROPOSED EXHAUST
AFL: 2.78
(300X300)

EXISTING ACCESS
HATCH (600X600)

PROPOSED ACCESS
HATCH (1200X620) &
(300X300)
4.09
026

4.09
4.09 033 4.09
027 F 036

AFL: 2.40
AFL: 2.40

AFL: 2.70
NOTE :

AFL: 2.40 EXISTING DOWN LIGHTS (IRS) 20


PROPOSED DOWN LIGHTS 23

DESIGN TEAM TO CONFIRM SIZES & LOCATION


4.C
REQUIRED FOR ALL NECESSARY ACCESS PANELS

DRAWING TITLE

TYPE B1a - REFLECTED CEILING PLAN


BUILDING NO LEVEL ROOM NO.

B4 L 09
DATE/TIME SCALE DRAWN BY

11/14/2017 8:32:43 AM 1:50 @ A3 DCLK R1


4.3 4.4
7.95 POWER OUTLETS, SWITCHES & EQUIPMENT

wm = washing machine : Socket 0.30, Switch 1.20


dwm = dishwasher machine : Socket 0.30, Switch 1.20
op = oven : Socket 0.30, Switch 1.20
4.B
fcu
r = refrigerator : Socket 0.30, Switch 1.20
ll fcu = fan coil unit : Socket / Switch 1.70
4.09 BALCONY 4.09 4.09
021 025 034 mw = microwave : Socket / Switch 1.20
ml ef = exhaust fan : Socket / Switch 1.20

2
ll ci = cooker ignition : Socket / Switch 1.20
MASTER BEDROOM
wh= water heater : Socket / Switch 1.20

4.09 ll

2
022 ll = low level - 0.30
ll

2
ml = medium level - 0.95
ll
BEDROOM gu = general use - 1.20

ml hl = high level - 1.70

2
ll CF
ll CF
ll
OUTLETS & EQUIPMENT
a
ll ll
7.90

4.09
026
13a single, switched recessed socket outlet.
a
2 13a twin, switched recessed socket outlet.
LIVING a
SH SH
gu 4.09 4.09
CF 033 Switched fused connection unit.
gu 036 gu
4.09 r
027
a
wm
13a single, unswitched fused recessed socket outlet.
ci
KITCHEN BATHROOM
SH Shaver outlet 115/230V - to be installed at
dwm
MASTER BATHROOM no less than 0,60m from taps
ef

op
wh

mw gu LIGHTING
ll CF
gu CF
2 Ceiling fan switch

One -way, 1 gang, 10A, recessed lighting switch


4.C
One -way, 2 gang, 10A, recessed lighting switch

Two -way, 1 gang, 10A, recessed lighting switch

Two -way, 2 gang, 10A, recessed lighting switch

TELECOMUNICATIONS SYSTEM NOTE:


Single data embedded socket (1xRJ45), mounted at h=0,3m . when coupled with a TV (RF) socket, All switches to be installed horizontzlly 1.2 meters from finished floor.
it should be mouted at the same height as the later
Refer to kitchen elevations for outlet and switch location
Dual data embedded sockets (2xRJ45), mounted at h=0,3m
DRAWING TITLE
Single TV (RF) embedded socket, mounted at h=0,3m
TYPE B1a - FLOOR PLAN WITH ELECTRICAL
Dual OS2 SC/APC embedded socket, mounted at h=0,3m,
BUILDING NO LEVEL ROOM NO.

Distribution board
B4 L 09
Intercom, mounted 1.4 meter from finished floor DATE/TIME SCALE DRAWN BY

11/21/2017 10:59:16 AM 1:50 @ A3 SB


LEGEND

AFL 2.40 HEIGHT ABOVE FINISHED FLOOR (2.40m)

DOWN LIGHT

LIGHTING ON CEILING
4.3 4.4
SURFACE LIGHT

SPRINKLER

TERMOVELOCIMETRIC DETECTOR

EXTERIOR WALL LIGHT

4.B
4.09 INTERIOR WALL LIGHT
021 AFL: 2.40 AFL: 2.40
4.09 AFL: 2.78 4.09 AFL: 2.78 FAN POINT
025 034

TERMOVELOCIMETRIC
DETECTOR
HVAC EQUIPMENT

4.09 HVAC EQUIPMENT


022 AFL: 2.40
PROPOSED EXHAUST
AFL: 2.78
(300X300)

EXISTING ACCESS
HATCH (600X600)

PROPOSED ACCESS
HATCH (1200X620) &
(300X300)
4.09
026

4.09
4.09 033 4.09
027 F 036

AFL: 2.40
AFL: 2.40

AFL: 2.70
NOTE :

AFL: 2.40 EXISTING DOWN LIGHTS (IRS) 20


PROPOSED DOWN LIGHTS 23

DESIGN TEAM TO CONFIRM SIZES & LOCATION


4.C
REQUIRED FOR ALL NECESSARY ACCESS PANELS

DRAWING TITLE

TYPE B1a - REFLECTED CEILING PLAN


BUILDING NO LEVEL ROOM NO.

B4 L 09
DATE/TIME SCALE DRAWN BY

11/21/2017 10:58:08 AM 1:50 @ A3 DCLK R2