1. The bidirectional detection current makes it easy for the user who detects the
charge and discharge to detect the bidirectional current without changing the wiring
direction.
2. Power-off memory function, able to memorize the number of AH and WH before
power off after power off, which is convenient for observation and measurement.
3, time and AH number clear function, does not affect the next measurement.
4. The number of AHs can be filled up without affecting the direct discharge
measurement.
5, voltage, current, charge capacity AH number, WH number, time, power at the same
time display, display information is comprehensive and clear.
6, with output off function keys, flexible open or shut off the output.
7, with over-voltage, over-current protection.
8, when necessary, you can turn off the LCD display, reduce product power
1 measured voltage value
2 Measured current value
3 measured power value
4 Accumulated capacity or energy value
5 Battery Remaining Capacity Progress Bar
6 percentage of battery remaining capacity
7 Measured temperature(Default withTemperature measurement function)
8 output status display
9 Total running time
10 Empty
Instructions
1, "BAT" battery capacity value setting, this parameter is to set the battery measured
total capacity.
2, "BPC" battery remaining capacity percentage, can be set according to the value of
the remaining battery AH
4, "OVP" set over-voltage protection value, if the OVP value is set, when the actual
measured voltage value is greater than the set value, it will prompt over-voltage, and
cut off the relay (self-provisioned).
5, "LVP" set over-voltage protection value, if you set the LVP value, when the actual
measured voltage value is less than the set value, it will prompt undervoltage, and cut
off the relay (self-provisioned).
6, "NCP" set over-voltage protection value, if the NCP value is set, when the actual
measurement of the charging current value is less than the set value, it will prompt
over-current, and cut off the relay (self-provisioned).
7, "OCP" set over-voltage protection value, if the OCP value is set, when the actual
measurement of discharge current value is less than the set value, it will prompt over-
current, and cut off the relay (self-provisioned).
8, "OTP" set over-temperature protection value, if the OTP value is set, when the
actual measured temperature value is greater than the set value, it will prompt the
temperature, and cut off the relay (self-provisioned ,Default without Temperature
measurement function).
9, "ADS" communication address code settings. In multi-machine communication,
multi-machine communication is achieved by setting the address code.
10, "TTL" instrument default relay output power state, normally open or normally
closed.
11, "CLR" no-load current clear function, if the actual no-load current is zero
Connection mode
Note: If the voltage range of the tested battery (power supply) during normal
operation is not between (6-75V), the external power supply connection mode can be
used. The external power supply voltage range is (6-75)V. The power supply selection
interface jumper cap is firstly used. Adjust to "3W", then connect the positive terminal
of the battery (power supply) to the voltage measurement port "Bat+" at the time of
connection, connect the negative pole of the battery (power supply) to the shunt
"BAT-", and the positive and negative poles of the power supply should not be
connected. Wrong or reversed. Connect the positive pole of the battery (power supply)
to the positive pole of the load, and connect the negative pole of the battery (power
supply) to the negative pole of the load through the other end of the shunt; the positive
pole of the charger is connected to the positive pole of the battery, and the negative
pole of the charger passes through the shunt. One end is connected to the negative
pole of the battery (power supply) phase.
Note: The relay's working power is provided by an external power supply. If the relay
is connected, an external power supply with the same working voltage as the relay
must be provided, and the power supply status of the instrument is adjusted to the
“3W” state. Connect the control port of the relay to the interface of the controller, and
then connect the negative pole of the power supply to the “BAT-” position of the
shunt through the normally open or normally closed port of the relay, and the wiring
of other parts will not change.