You are on page 1of 16
‘Current Transformer | Control Transformer ~@CE ee ming [Measuring ITs a NEWTEK ELECTRICALS 7 Brief History: The Company was originally started as Wintek Electricals Pvt. Ltd. company asa Joint Venture with a German company in the year 2005. Thus the journey of Wintek Electricals Pvt Ltd began with a blend of technical expertise from Germany and india, With technical collaboration between the two, Innovations were introduced which speak for themselves even today. With increasing demand for quality Transformersin the Indian Market, it was the need of the hour to cater to the needs of Indian market, which had a large potential which was increasing twofold every month. Accordingly the bold step had to be taken and finally a completely independent company “Newtek Electricals" was formed in the year 2007 with the sole intention of introducing International Standard CTsin the Indian Market. AboutUs: We Newtek Electricals introduce ourselves as manufacturer of Instrument Transformers (CTs, PTs, COTR etc. and Digital Meters (VAF, MFM, kWh]. Newtek Electricalsis an ISO 9001:2008 certified. We are the first one to introduce Nylon Flame Retardant Casing Current Transformers (CTs). (ur product is been used in many prestigious projects in India as well asin other countries. The company has established its reputation within a short period as an innovative leader and quality manufacture by continuously upgrading technology, modernizing and manufacturing facilities and maintaining highest standards of quality and services. (ur Quality Concey We are dedicated towards upgrading the quality of Instrument transformers and digital meters. We share your high demands on quality, technical proficiency and services, These demands are an integral part of our company and serves as a constant reminder of tasks that we have taken as our responsibility. Every time we complete a job, we have improved our quality and thatis what we are constantly striving todo. Alltransformers are thoroughly tested during manufacturing process for any defects so that we can give guarantee to you to receive a quality product. Apart from all these our CTs and Meters are approved by CPRI (Central Power Research Institute, Bhopal) and ERDA (Electrical Research Development Association, Vadodara), respectively SUELON iaacaestel ABB G : x. 7 accusonic vais pogerol Bimarine ctctrcals ae Pe ere) ft ACC ACC LIMITED ySw aa @ he MERIDIEN Mit MUNDAS SUGAR, RANBAXY Ein Milf p TARORATORIES LIMITED oh ahindra Satyam en TATA eX sane | metiogFe Ola Deutsche Bank MECON Limited. ‘Avant Garde Consultants, Chennai ‘Tata Consulting Engineers, India, ‘Semac Consulting Engineers Bangalore, ‘Synergy Infra Consultants Pvt. Ltd, Knexir, Mumbai. Hyderabad. Entask Consultancy Services JP Mukerji & Associates, Pune. ‘AECOM (previously Spectral Services ‘Abhiyanta Electricals and Consultants Pvt Ltd Engineers Consultants, Pune. Bi RSP Consulting Engineers, Bangalore. GR, Narayan Rao Consultants Sripeksha Engineering Consultancy Services Pvt. Ltd, '5.N. Joshi Consultants, Pune ‘Mott MacDonald, Ahmedabad, ESKAYEM Consultants, Mumbai Convenient Construction & Seth techno Consultants, Unique Consultant Services, Consultancy Pvt, ltd, Indore. ‘Ahmedabad Sangii/Pune. Powertec Engineering, Chennai Kausi Consultancy Services SR Associates, Chennai WSP Consultants India Lt. Technip India Utd ers, Chennai © QA NEWTEK ELECTRICALS —_——— ay Steel Project Pharmaceuticals Shipyard 1. Kalyani Garuda, Raichur 1. Ranbaxy, indore 1. Cochin Shipyard, Cochin 2. BSRM, Bangladesh 2. Sun Pharma, Baroda 2 Bharti Shipyard, Mumbai 3. Sohar, Oman 3. Glaxo Smith’kiine, 3. Hindustan Shipyard, Vizag, 4. 1SPL, Tamnar Chandigarh 4. ABG Shipyard, Cochin 5. Durgapur Steel Plant 4, Ranbaxy, Chandigarh 5. Goa Shipyard, Vosco 6. ISW'Steel, Dolvi 5. Macleods Pharma, Daman Da Gama Sugar Chemical Textile 41. Renuka Sugar, Brazil 1. Safe Water Chemicals, 1. Well Known, Daman 2. Daund Sugars, Rohtak Kuwait 2 Santham Textile, Silvasa 3, Enpro Sugar, Rohtak 2. Hydrogen Plant, Mundra 3. Bhilosa, Silvasa 4, Mummias Sugar, Kenya 3. Himedia Lab, Nashik 4. Creative Textile, Balitha 5. Shiraguppe Sugar, Belgaum 4. Kalpataru Organics, Sarigam 5, Madura Inds, Valsad TT Malls Educational 41. Cyber City, Hyderabad 1. Patna Malls, Patna 1 Rajiv Gandhi College, 2 Cybermotion, Hyderabad 2. Shopper Stop, Bhopal Chandigarh 3. Trinity Software Solution, 3. Magarpatta Mall, Pune 2. Karpagam Medical Hyderabad 4, Shopper Stop, Mumbai College, Coimbatore 4, Mahindra Satyam Energy Infrastructure Automobile 1. Bharat Billi, Airoli 1. Mumbai Int Airport, Mumbai! 1. Mahindra Vehicle, Chakan 2. Alstom, Vadodara 2. Cinepolis, Patna 2. VE Commercial Vehicle, 3. Cummins, Pune 3. Mantri Developers, Banglore Pitampur 4, Kirloskar, Saswad 4. Magarpatta City, Pune 3. Essar, Mumbai 4, VHCL, Umbergaon Hotel Government Banking 1. Hotel Grand Hyatt, Goa 1. MTRDC, Bhopal 1. ICICI Bank 2 Le Meridien, Coimbatore 2: PWD, Shopal 2. Deutsche Bank, Murnbai 3. Silver Tower 3. BHEL Site Office, Ranchi 3. Bank of India, Mumbai Petroleum Cement Project Telecom 2, HPCL, Sugaul 1. Sagar Cement, 2. Relaince Communications 2. Indian Ol Tank, Bhogat Hyderabad Mumbai 5: Br Petrochemicals id 2, atc cement, Vizag 2, Reliance 46, Mumbai Mangalore 3. Birla Cement, Chittorgarh 4 Aaltya Cement, chitergarh Pulp & Paper Mill Submarine Project Metro 1. PT indo, Indonesia 1. VALE Project, Brazil 1. Hyderabad Metro 2. Subam Papers 2. Bangalore Metro. Beverages Electricity Board Industrial 4. Coca Cola, Varanasi 1. TNeB Ltd 2. Perkins India Pvt. Ut 2. Carlsberg, Aurangabad 2. CSPDCL Aurangabad. 3. MPMKWVCL, Bhopal & Gwalior @ NEWTEK ELECTRICALS 7 ‘Window Type Current Transformer NE R21 NE 210S cne10 ‘All Dimensions are in "mm" SO(Lyx7O(H)x340T) Xa NEWTER ELECTRICALS | NE 3R30 Primary Curent Cla 08 Clet-10 Caer 20 NE 310 Eran (oy ax Primary Bar 30 X 10, NE 4R30 NE 4B312 Primary Curent Cas 05 | Cass-10 Case stuxs7tHpe40mn ‘Ail Dimensions are in “mm NEWTEK ELECTRICALS 7 NEM 5R30 NEM 5B312_ NE4R40_ NEWTEK ELECTRICALS NEM 5B412 NE 6R 65, ‘Ail Dimensions are in "ma" setuciayxsorm NEWTEK ELECTRICALS Be NE 640 Co NE 815 ts NE 830H/NE 830V BEgggeuees EEggEezes NEWTEK ELECTRICALS NE 1030H/NE 1030V_ 1030H/NE 1030V_ 0 NE 1056 6 NE 1256H/NE 1256V NE 1656H/NE 1656 0 js I Ne 1256H 145(1)x165(H)X40(7) NE 16504 145(1)x205(H)x40(7) 133(4260(4)x30(7) Pemay caret Cae05. Cet aUxas0HH0m Primacy Caren a5 ne 10 Ne t256v 29(4x183(4)x40(7) Ne 1656v ‘All Dimensions are in "mm" 129(4x223(H)x40(7) NE 1659H/ NE 1659V } | NE 1659 74(yx23(4 57) NE 2065H/ NE 2065V tT ee oh Gls ; , ? mii ; | | { Penecaens (NE 2065H NE 2065V 00 as 20 = ‘WOUND PRIMARY CURRENT TRANSFORMERS NE 3WST/NE 4WST. Neawst Neawsr o(xa0(4)x30(7) ayxa7(x40(7) NE 4WPL6/ NE MSWPL6. a(yem7myxzorr)———_754yxtoogxaser) NEM SWPL8/NEM 5WPL10 Sua wesw) Newswente "Sta ano "uyxtotHxes(7 PT renee ie Ne e201 #20 Ne soon 40300 Neswst NEAWST,NEAWPLS NEM SWPLS, NEM SWPLE, NEM SWPLIO Ss = = Ta lt ta Me Protection Class CT's in Nylon Casing NEP 635H NEP 1257H ‘All Dimensions are n "rma" E7O(YRAS6HHASSET) ATT oe Mey Bee eu ue) Single Phase Tape Insulated/Resin Cast Control/ Voltage Transformer. (Overall Dimensions (APprox) ‘Ratingin VA Arm) | rm) Cl) | Dram) Apo wines. Se Soo” seo” 9s eee 3 so im | wt ka Sco isr | >| wo 00 | ma m0 | sy | | wo | 100 | a | 8s aw | as | iso | 0 | iy | us| as ao MSs |i | a0 sow | so | io ass | ise as | was Three Phase Tape Insulated/Resin Cast Control/ Voltage Transformer. ‘overall mension approx) three phase atngin VA. Ate) |B (rm) |Clom) |e) Erm) | ABR wt nA. 30 so was) a0 tes a = woo es 15) as % feo estes amos 00 sooo | ss | ts | mo ars | 6 us ‘All Dimensions are in "mm" [Note: Voltage & Cont Transformers can be made availabe from 50VA to 5000VA burden, both in single phase & three phase systems as per customers demand. QA NEWTEK ELECTRICALS NEWTEK CTs: Increased Safety- ‘The joining point where the two halves ofthe housing meet inside the primary bar opening is crucial to safety. Quite in accordance with NEWTEX's matto~safetyis builtinto our produets— the two halves of the housing are not aligned with a butt joint, instead they are made to (overlap in the new NE series. Insulated Protective Caps For Primary Fixing Bolts ~ To protect, against unintentional contact the bolts of the primary fixing devices can be covered by protective insulation caps. ‘TheNEWTEKSecondaryTerminals— In this clamping system pressure is transmitted by means of a nut (Pad) to the ends of ‘theconductoLitprinciple,Theconductoristhereforeloadedoniyunderaressureand cannot bbedamagedbyrotatingcomponents.Thankstocurclampingsystemtheendsoftheconductors areclampedoverawideareawhichensureslowercontactresistance. Pressureforcesofseveral hundredNewton'sarereached.Inthese wayconductarsevenwith multiple fineandextremely fine wires are so well compressed that no harmful gases can penetrate to cause corrosion. It therefore provides an extremely long lasting connection even in aggressive Industrial environment. Theplus~minusslotofthe MS (0.5mm) screwsallowseasein handling, Atthe NE seties both, screws and nuts are designed in such @ way to prevent unintentional loosening Mounting Arrangement of Newtek CTs Secondary Terminal Covers Base Mounting Clamp Bus Bar Mounting Clamp Din Rail Mounting Clamp us Bar Mounting for Protection CTs! Bus Bar Mounting for Low Burden CTs @ NEWTEK ELECTRICALS 7 General Features of NEWTEK Current Transformers Electrical Features ‘Mechanical Features Rated frequency = 50-60 He Unbreakable, flame retardant, seif-extinguishing Class of insulation = E Nylon casing of grade UL 94 V2. Rated short time thermal current th = 60 In Cores are made from high grade CRGO material Nominal surge current Idyn = 2.5 Ith Dual coated copper wire having class of insulation (Minimum 200 kA at all window type C's) Nickel platee secondary terminals with Highest voltage for equipment Um = 0.72Kv plus minus screws of 0.5Nm. (ther voltages on request) Integrated secondary terminal caps. Rated power-frequency withstand voltage = 4Kv/ Imin (Other voltages on requestlinstrument security facto Special Notes ‘Applicable Standards: C'salso avalable in 0.55, 0.2 and 0.28 accuracy lass on request. Current Transformer: i: 2705/1992; IEC/EN: 60084-1 Other VA's are s per customer requirement Potential Transformer: I: 3156/1992; FC: 60044-2 Control Transformer: IS: 12021/1987; IEC: 6004-2 Control & Potential Transformer: "Newtek provides tallor made range of LI Potential & Control Transformer as per customers demand both in single phase & three phase systems, in Resin Cast/Tape Insulated/Varnish Impregnated type of Insulation, Voltage range 0 to 690V, Max VA:-1OKVA. We can supply dual secondary, tap changer type PTS & Control Transformers. Avaliable Class of PTs: 0.2,05,1.0,36P We can provide you IVTs, RVTS on demand. 35 « at S&S AP —— met . Resin Cast CTs *_NE2105 & NE310S Model vs Shrouding Cap for WPLCTS Base Clamp for Resin Cast CTS Bus Bar Clamp Newtek Resin Cast CT's [Newtek Electricals also innate the exzertis in design and manufacturing of conventional resin cast CT's, as wall as protection lass CT's. VIZ, 55, SPIO, 5P20 & PS Class C's NEWTEK ELECTRICALS @ NEWTEK ELECTRICALS HERTZ INSTRUMENTS PVT. LTD. M-90 M.1.0.C, Waluj, Aurangabad ~ 431136 Maharashtra, India. Tel/Fax : +91-0240 2551555 Mobile : 9370062635, 9372862635 Email :newtekelectricals@gmail.com, mkt.newtek@gmail.com Website : www.newtekelectricals.com

You might also like