midas Gen RC Column Checking Result

Company Project Title


Author Kevin File Name D:\...\Proyecto JHuamani.mgb
1. Design Condition z
Design Code : ACI318-05 UNIT SYSTEM : tonf, m
Member Number: 588 (PM), 590, 588 (Shear-y,z)
Material Data : fc = 2109.21, fy = 42184.2, fys = 42184.2 tonf/m^2
Column Height : 2.5 m

0.25
Section Property: C25X35 (No : 1) y
Rebar Pattern : 6 - 3 - #5 Ast = 0.0012 m^2 (Rhost = 0.014)

0.0635
2. Axial and Moments Capacity 0.35

Load Combination : 5 (Pos : J)


Concentric Max. Axial Load PhiPn-max = 106.778 tonf
Axial Load Ratio Pu / PhiPn = 5.99943 / 6.88456 = 0.871 < 1.000 ....... O.K
Moment Ratio Mc / PhiMn = 3.71713 / 4.20266 = 0.884 < 1.000 ....... O.K
Mcy / PhiMny = -3.7139 / 4.19887 = 0.885 < 1.000 ....... O.K
Mcz / PhiMnz = 0.15443 / 0.17850 = 0.865 < 1.000 ....... O.K

P-M Interaction Diagram


P(tonf)
215
PhiPn(tonf) PhiMn(tonf-m)
188 Theta=2.43Deg.
N.A=0.97Deg. 133.47 0.00
161 110.66 1.97
134 92.79 3.12
74.81 3.73
107107
57.43 3.99
79 41.75 4.05
52 31.85 4.05
25
28.44 4.15
20.40 4.21
0
-2 (7,4)
(6,4)
M(tonf-m) 5.05 4.19
-29 -13.61 2.96
-57 -34.22 1.31
-45.56 0.00
1

3. Shear Capacity
[ END ] y (LCB : 4, POS : J) z (LCB : 4, POS : J)
Applied Shear Force (Vu) 3.78323 tonf 2.82041 tonf
Design Shear Strength (PhiVc+PhiVs)
4.28295 + 6.43274 = 10.7157 tonf 3.93745 + 4.18745 = 8.12490 tonf
Shear Ratio 0.353 < 1.000 ....... O.K 0.347 < 1.000 ....... O.K
As-H_use 0.00071 m^2/m, 2-#3 @200 0.00071 m^2/m, 2-#3 @200

[ MIDDLE ] y (LCB : 4, POS : 1/2) z (LCB : 4, POS : 1/2)


Applied Shear Force (Vu) 3.78323 tonf 2.82041 tonf
Design Shear Strength (PhiVc+PhiVs)
4.29399 + 6.43274 = 10.7267 tonf 3.94751 + 4.18745 = 8.13497 tonf
Shear Ratio 0.353 < 1.000 ....... O.K 0.347 < 1.000 ....... O.K
As-H_use 0.00071 m^2/m, 2-#3 @200 0.00071 m^2/m, 2-#3 @200

Modeling, Integrated Design & Analysis Software Print Date/Time : 08/06/2022 17:33