Professional Documents
Culture Documents
com
TEL:1-646-852-9286
MEMBER NAME : C1 -
400x500
1. General Information
(1) Design Code : ACI318M-14
(2) Unit System : N, mm
2. Material
(1) F'c : 20.68MPa
(2)
Fy : 276MPa
(3)
Fys : 276MPa
3. Section
5
4. Load Combinations
(1) Section Size : 400 x 500mm
General Forces Factors
(2) Lx : 3.600m
Pu Mux Muy Vux Vuy
(3) No
Ly CHK : 3.600m
Name Cmx Cmy βd
(kN) (kN·m) (kN·m) (kN) (kN)
(4) Kx : 1.000
- PM cLCB7 525 143 8.453 6.624 61.18 0.850 0.850 0.757
(5) Ky : 1.000
- Vx cLCB17 42.36 34.03 -13.59 7.049 -14.29 0.850 0.850 1.000
(6) Splicing Limit : 50%
- Vy cLCB17 208 -103 7.452
400 4.185 -61.44 0.850 0.850 1.000
(7) Frame Type : Braced Frame
1 Yes cLCB2 915 0.256 4.299 3.783 0.0968 0.850 0.850 0.540
2 Yes cLCB17 42.36 34.03 -13.59 7.049 -14.29 0.850 0.850 1.000
3 Yes cLCB7 525 143 8.453 6.624 61.18 0.850 0.850 0.757
4 Yes cLCB17 295 -142 1.608 2.090 -60.94 0.850 0.850 1.000
5 Yes cLCB10 556 3.511 100 46.83 4.686 0.850 0.850 0.773
6 Yes cLCB8 471 -1.447 -101 -47.12 2.872 0.850 0.850 0.801
7 Yes cLCB8 525 -9.572 -100 -47.22 -4.093 0.850 0.850 0.712
8 Yes cLCB7 369 104 22.66 12.63 61.90 0.850 0.850 0.761
9 Yes cLCB17 208 -103 7.452 4.185 -61.44 0.850 0.850 1.000
5. Rebar
(1) Main Bar
Layer-1 : 10 - 3 - P25 ( Cc = 62.50mm, As = 4,909mm² )
Layer-2 :-
Layer-3 :-
Layer-4 :-
As.total : 4,909mm²
(2) Hoop Bar
End : P10@50.00
Middle : P10@150
(3) Tie Bar
Apply Tie Bar to Shear Check : No
6. Option
(1) Special provisions for seismic design is applied.
(2) Frame Type : Special Moment Frame
MEMBER NAME : C1 -
400x500
δns.y Cm
= = 1.000
1- Pu / 0.75Pc.y
MEMBER NAME : C1 -
∑Fs = 231kN
∑Mnx = 177kN·m
∑Mny = 19.91kN·m
(3) Calculate nominal capacity for neutral axis
Pb = Cc + Ps = 2,015kN
Mnx = Mnx.conc + Mnx.bar = 392kN·m
Mny = Mny.conc + Mny.bar = 49.52kN·m
Mn = ( Mnx )2 + ( Mny )2 = 396kN·m
MEMBER NAME : C1 -
∑Fs = 21.23kN
∑Mnx = 201kN·m
∑Mny = 12.21kN·m
(3) Calculate nominal capacity for neutral axis
Pn = Cc + Ps = 1,489kN
Mnx = Mnx.conc + Mnx.bar = 411kN·m
Mny = Mny.conc + Mny.bar = 41.81kN·m
Mn = ( Mnx )2 + ( Mny )2 =
413kN·m
(4) Calculate strength reduction factor
εt.min = 0.0017, εt.max = 0.0050
εt = -0.000000
ø = 0.650
(5) Calculate axial load and moment capacities
øPn = 981kN
øMnx = 270kN·m
øMny = 27.54kN·m
øMn = 272kN·m
Mux / øMnx = 0.529 < 1.000 → O.K
Muy / øMny = 0.515 < 1.000 →
O.K Pu / øPn = 0.536 < 1.000 →
O.K Mc / øMn = 0.529 < 1.000 →
O.K
P (kN)
5000
θ=5.82˚
4350 N.A=17.52˚
3700
3050
22448080
1750 eb=355.43mm
1100
(981,272)
450 (525,144)
0 M (kN·m)
-200
-850
-1500
0
4
14. Calculate Shear Force by Special Provisions for Seismic Design (Direction Y).
(1) Calculate bending strength for design shear force.
ø = 1.000
MIDASI http://
www.midasuser.
Mprx,I.CW = 85.01kN·m
MEMBER NAME : C1 -
Mprx,J.CW = 85.01kN·m
Mprx,I.CCW = 85.01kN·m
MIDASI http://
www.midasuser.
MEMBER NAME : C1 -
Mprx,J.CCW = 85.01kN·m
(2) Calculate design shear force by special provision for seismic design
Vey1 = (Mprx,I.CW + Mprx,J.CW )/Lny = 242kN
Vey2 = (Mprx,I.CCW + Mprx,J.CCW )/Lny = 242kN
Vey = max(Vey1 , Vey2 ) = 242kN
15. Calculate Shear Force by Special Provisions for Seismic Design (Direction X).
(1) Calculate bending strength for design shear force.
ø = 1.000
Mpry,I.CW = 410kN·m
Mpry,J.CW = 462kN·m
Mpry,I.CCW = 410kN·m
Mpry,J.CCW = 462kN·m
(2) Calculate design shear force by special provision for seismic design
Vex1 = (Mpry,I.CW + Mpry,J.CW )/Lnx = 47.23kN
Vex2 = (Mpry,I.CCW + Mpry,J.CCW )/Lnx = 47.23kN
Vex = max(Vex1 , Vex2 ) = 47.23kN
øVs Av fyt d
=ø = 219kN
s
øVn = øVc + øVs = 336kN
Vu / øVn = 0.141 → O.K
(3) Calculate Shear Strength (Direction Y)
s = 50.00mm < smax = 100mm → O.K
Nu
øVc = ø0.17 (1+ f'c bw d = 121kN
)
14Ag
Av fyt d
øVs = ø s = 285kN
øVn = øVc + øVs = 405kN
Vu / øVn = 0.598 → O.K