Professional Documents
Culture Documents
2020 10:29:27
/Device ID/Identification
Actuator model AC 01.2
Designation PR02-20-MOV-11
Project name PRPS-02
/Device ID/Identification/Actuator
Order no. actuator 13412397
Serial no. actuator 0518MD88037
Wiring diagram actuator 00R100-0I1-000
/Device ID/Version
Firmware 05.09.05-60779
Language 105
/Customer settings/HART
Loop current mode Activated
Address 0
Monitoring time 15.0 s
/Customer settings/Positioner
Adaptive behaviour Adaptive I
Dead time 0.5 s
Positioner hysteresis OPEN 0.5 %
Positioner hysteresis CLOSE 0.5 %
Tolerance CLOSE 1.0 %
Tolerance OPEN 99.0 %
Limit setting range Function not active
Limit OPEN 100.0 %
Limit CLOSE 0.0 %
/Customer settings/PVST
PVST operation mode Stroke
PVST behaviour CLOSE
PVST stroke 10.0 %
PVST monitoring 01:00,0 min : s
PVST reversing time 00:02,0 min : s
PVST reminder Function active
PVST reminder period 90 d
PVST source Active interface
/Device configuration/HART
Device categoy Actuator
Current out impedance Not activated
WirelessHART adapter Not available
Number request preambles 5
Number response preambles 5
Current zero input 4.00 mA
Current span input 20.00 mA
Current zero output 4.00 mA
Current span output 20.00 mA
LRV Input 0.0 %
URV input 100.0 %
LRV output 0.0 %
URV output 100.0 %
/Device configuration/Actuator
Motor protection mode Auto
Closing rotation Clockwise rotation
Handwheel switch Without
Heater control unit Auto
/Device configuration/Actuator/MWG
Nominal torque CLOSE 250 Nm
Nominal torque OPEN 250 Nm
CLOSE min. angle value 113
CLOSE min. torque 40 %
CLOSE max. angle value 67
CLOSE max. torque 100 %
OPEN min. angle value 141
OPEN min. torque 40 %
OPEN max. angle value 183
OPEN max. torque 100 %
Correction CLOSE 100
Correction OPEN 100
Hysteresis torque 5%
Dead band torque 2
Hysteresis limit 3
Torque adjust 0 point 0
Low limit torque CLOSE 100 Nm
High limit torque CLOSE 250 Nm
Low limit torque OPEN 100 Nm
High limit torque OPEN 250 Nm
Torque-scaling factor 150.0 %
/Device configuration/Switchgear
Reversing prevention time 0.3 s
/Diagnostics/Bluetooth
Designation PR02-20-MOV-11
Bluetooth address 00:13:43:61:bd:0e
/Diagnostics/Positioner
Adaptive behaviour Adaptive I
Setpoint %
Actual position %
Outer dead band OPEN %
Outer dead band CLOSE %
Inner dead band OPEN %
Inner dead band CLOSE %
/Diagnostics/HART/Version
HART application 01.16
HART stack V7.4 Rev. A_0346
HART updater 01.04
/Diagnostics/HART/Device identification
Manufacturer ID code 24700
Expanded device type 57853
Device identification number 2254962
Device revision level 3
Software revision level 2
Hardware revision level 2
Protocol revision level 7
/Diagnostics/HART/Plant identification
Tag ????????
Long Tag 0518MA21869
Message ????????????????????????????????
Date code 65792
Descriptor ????????????????
Final assemby number 0
/Diagnostics/HART/Communication status
Channel 1 DataEx
Channel 1 activity
/Diagnostics/HART/Current values
AI raw value mA
AI loop current mA
AI fail low
AI fail high
AI saturated
AO raw value mA
AO loop current mA
AO fail low
AO fail high
/Diagnostics/HART/Status information
Field device status primary master
Field device status secondary master
Extended device status information
Standardised status 0
Standardised status 1
Analog channel saturated
Analog channel fixed
/Diagnostics/Torque tripping
Torque reference
Trip.current OPEN byp
Trip.current CL byp