You are on page 1of 296

1.0.

Introduction

1.1. Malaysian Standard Method of Measurement (‘MySMM’, its acronym) of Building Works
(First Edition) for use in Malaysia has been written to provide a standard set of
measurement rules for the preparation of bill of quantities (BQ) and schedules of works
(quantified) for building works, and a framework that can be used to develop bespoke and
standard schedules of rates.

1.2. In keeping with the advancement in construction technologies in Malaysia, MySMM has
incorporated rules governing the measurement of such technologies, e.g. Industrialized
Building System (IBS), diaphragm walls, reinforced earth, etc.

1.3. In sync with the use of Building Information Modeling (BIM) technology in the construction
industry in Malaysia, MySMM has incorporated BIM-friendly features i.e. simplification of
measurements, reduction in measurable building components/items, simplification of
building components/items description and provision of guidelines as to the specific
information to be shown in 3D models by the respective consultants for ‘quantities’
extraction purposes from the 3D models.

1.4. MySMM also includes guidelines to the drafting of ‘Preliminaries’, ‘Specification’ and
‘Preambles’, all of which form parts of the procurement document for building works.

1.5. The main part of MySMM is in a tabulated form (‘the Tabulation’) divided into levels. The
main intention is that any building component/item description can easily be formed by
extracting the relevant parts of the description from each level in the Tabulation and filling
in any missing information and/or dimension as advised therein. Truly, the parts of the
description and the unit of measurement for each of the building components/items shown
in the Tabulation are the actual rules of measurement, which have to be read in
conjunction with ‘Specification’ and ‘Preambles’ as stated in Item 1.1.4 above. It also
serves as a template for the description of any components/items not found in MySMM.

1.6. There are specific rules of measurement that cannot be inferred or covered by the
component/item descriptions and ‘Preambles’. Such rules are dealt with in ‘Specific Rules
of Measurement’ section of MySMM

Items 1.1-1.6 above set-out the main objectives of MySMM, which, in essence, shall
propel the QS profession towards standardization of component/item descriptions,
Preliminaries items, Specification and Preambles in the production of procurement
document of building works as well as to be a member of the BIM team specializing in
extraction of ‘quantities’ from the 3D model.

1.7. MySMM embodies the essentials of good practice and is understandable by all the
stakeholders involved in a construction project e.g. the employer, the contractor, the
project/design team, etc. and is equally applicable to both proposed and executed works.

1.8. Rules of measurement adopted for work not covered by these rules shall be stated and
such rules shall as far as possible conform with those given in this MySMM for similar
work.

1
2.0. Tabulated rules of measurement for building works

2.1. Introduction
2.1.1. The rules comprise:

(1) the information and requirements for the main contractor’s preliminaries; and

(2) the rules of measurement for building components/items which are grouped
under 28 Work Sections.

2.2. Interpretation

2.2.1. The rules of measurement for building works are set out in tables. The tables are divided
into two categories, namely those dealing with:

• preliminaries; and
• measurement of building components/items

2.2.2. The rules are written in the present tense.

2.2.3. The symbol ‘/’ used between two or more units of measurement or within the text, means
‘or’.

2.2.4. Horizontal lines divide the tables and rules into zones to which different rules apply.

2.2.5. The use of broken lines (-------) between two different supporting information in these
tables means with different units of measurement but under the same level for the building
components/items.

2.2.6. The use of a hyphen (-) or the phrase ‘to’ between two dimensions in these tables or a bill
of quantities means a range of dimensions exceeding the first dimension stated but not
exceeding the second.

2.2.7. This bracket, ( ) contains an instruction as to the insertion of drawing nr., dimension,
width, length, diameter, etc. and shall be deleted upon such insertion while this bracket
{ } contains the additional supporting information e.g. ‘measured separately’.
‘consolidated thickness’, etc. and NOT to be deleted.

2.2.8. The ‘S.O.’ an acronym that stands for Superintendent Officer which can also mean the
Architect or the Engineer or Specialist Consultant as the case may be.

2
2.3. Work Sections

2.3.1. Work Section 01 tabulates the common preliminaries items encountered in a main
contract together with the rules for describing the information and requirements related to
each of such items therewith in the form of tables structured as follows:

(1) There are nine group headings under which these preliminaries items are
grouped, namely,

(i) Generally;
(ii) Bills and Pricing/Pricing;
(iii) Materials and Samples;
(iv) Form of Contract;
(v) Statutory Obligations;
(vi) Contract Administration;
(vii) Site Control;
(viii) Temporary Works; and
(ix) On Completion

(2) Each of the above group headings has a table whereby the information and
requirements related thereto are specified ( ‘the Table’)

(3) The left-hand column (sub-heading) of the Table lists the common preliminaries
items to be provided under the heading;

(4) The second column (information and requirements) lists the information and
requirements which shall be included within the preliminaries descriptions.

(5) ‘Preliminaries’ prices are to cover the cost of administering a project and
providing plant, site staff, facilities, site-based services, and other items not
included for in the rates for measured work. Therefore, the ‘information and
requirements’ given therein ONLY serve as a guide as to the drafting of Work
Section 01: ‘Preliminaries’ commonly encountered and are by no means
exhaustive.

3
2.3.2. Work Sections 02-29 are as follows:

02 IBS
03 Demolitions, alterations, repairs, and conservation
04 Excavating and filling
05 Ground remediation and soil stabilisation
06 Piling
07 Diaphragm walls and underpinning
08 Crib walls, gabions, and reinforced earth
09 Insitu concrete works
10 Prestress/precast/composite concrete
11 Masonry
12 Waterproofing
13 Roofing
14 Carpentry
15 General joinery
16 Structural metalwork
17 Metalwork
18 Cladding and covering
19 Floor, wall and ceiling finishes
20 Glazing
21 Decoration
22 Drainage and piping works below ground
23 Site works
24 Fencing, turfing and planting
25 Plumbing services
26 Mechanical services
27 Electrical services
28 Transportation
29 Builder's work in connection with mechanical, electrical and transportation
installations

4
2.3.3. A table is created for each Work Sections 02-29 and is structured as follows:

(1) At the beginning of each Work Section there is a list of group headings under
which the building components/items are categorized.

(2) The first four rows of the tables set out in the following order:

(a) Information to be provided in the Specification


• This row lists some important heads of information that are required
to be further elaborated and incorporated in the Specification for each
Work Section.
• There are two main types of specifications used, namely, ‘prescriptive
specifications’ and ‘performance specification’.
• The function of the prescriptive specification is to prescribe the
materials, method of assembly and installation, and workmanship
required for the building components/items in as much detail as
possible. Specific products may be named, and the assembly of the
products may be prescribed and supported with drawn information
and schedules. Where materials are not named, reference will be
made to published standards governing their make e.g. British
Standards, Malaysian Standards, JKR Standards, etc.
• A performance specification describes the requirements of a product
(e.g. curtain walls), equipment (e.g. rainwater harvesting system),
system or installation in terms of the performance objectives or criteria;
in which case, the contractor is responsible for the selection of
materials and design development to meet the performance
requirements and therefore, the design may not need to be advanced
for performance-specified work before inviting tenders from
contractors.
• If there is NO mention of ‘Performance Specification’ in this row, the
content will be treated as ‘Prescriptive Specification’.

(b) Specific information to be shown in the 2D drawings or to be input into the


3D models
• This row gives a guideline as to the specific information to be shown
in the 2D drawings or to be input into the 3D models by the respective
design consultants in order to facilitate the extraction of ‘quantities’.
For 3D models, it aims to facilitate direct extraction of ‘quantities’ from
the 3D models and also serves as a guide in filling the required details
in the Model Content Matrix in the BIM Execution Plan.

(c) Specific rules of measurement


• This row gives specific rules of measurement where neither the
Preambles nor the building components/items description can infer
such rules.

(d) ‘Works and materials deemed included’ which are collectively referred to
as the ‘Preambles’
• This row gives the Preambles related to each of the Work Sections.
• If any building component/item under any Work Section appears in
other Work Section/s, then the relevant ‘Preambles’ related to that
building component/item shall similarly be applied to the same.

5
• Its main intention is that in the preparation of BQ, it can be stated that
the BQ shall be read in conjunction with the Preambles in MySMM
instead of repeating them in the BQ document. As such, it serves as
a universal standard for ‘Preambles’ in Malaysia. However, if
additional Preambles are required, it can be added to the BQ
document accordingly.

(3) The first column from the left (‘Item or work to be measured’) , lists the headings
of the building components/items descriptions numerically (‘the Heading’) ;

(4) The second column (‘Unit’) lists the unit of measurement for building
components/items;

(5) The third column (Level One) lists the information numerically, including any
dimension requirements, that shall be included in the description of the building
components/items;

(6) The fourth column (level Two) lists the supporting information numerically,
including any additional dimension requirements, which shall be included in the
description of the building components/items.

(7) The fifth column (level Three) lists the further supporting information
numerically, including any additional dimension requirements, which shall be
included in the description of the building components/items;

(8) The sixth column (notes, comments, and glossary) deals with the following:

(a) definitions of some generic terms and phrases used in connection with
the building components/items;

(b) additional information to be added into the Heading or the specific level
to complete the descriptions of some of the building components/items;

(c) ‘Notes’ to be added preceding the Headings (which more frequently


occurs for building components/items with Contractor’s design); and

(d) clarification of the approach to quantification and items deemed included


in the description of building components/items.

(9) It is to be noted:
(a) that any descriptions of building components/items with the same ‘Heading’
should have the same number of ‘Level’ of information and/or supporting
information. In the event that any one of them is short of one such Level,
then ‘generally’ will be used in its place;

(b) that the first letter of the word for all levels except the last level is to be
‘capital-letter’;

(c) that the number of Headings, the different situations and the supporting
information appear in the respective columns are NOT exhaustive, but they
represent the ones commonly encountered in building works; and

(d) that in principle, the table give a standard template for the descriptions of
any building components/items.

6
2.4. Coding

2.4.1. For codification, each level of the table is numbered. An example as to how an building
component/item can be created and coded is given below:

(1) Work Section 09 : IN-SITU CONCRETE WORKS


Group : 04 REINFORCEMENT
Heading
‘Heading’ : 14 High tensile steel bar reinforcement
Level One : 01 In foundations
Level Two : 03 12mm diameter; curved

(2) The parts of the components/item description in ‘italics’ as shown above are
extracted from the table created in accordance with Item 2.3.3 (3)-(9) above to
form a full description for a component/item which will have the following code
number :
09 04 014 03 03 00

(3) Coding for any component/item description shall have six (6) facets. The above
shows how the first five facets are obtained from the respective numberings from
the table while the six facet is ‘00’ because this component/item description has
no Level Three.

(4) It shall also be noted that it is a good practice in the preparation of BQ that the
component/item description is created with an indent for each part of the
description as shown above.

3.0. General Measurement rules applicable to all Work Sections

3.1. Quantities

3.1.1. The general rules for quantifying building components/items are as follows:

(1) Measurement and billing:

(a) Measure the work net as fixed in position unless otherwise stated.

(b) Net quantity measured shall be deemed to include all additional material
required for laps, joints, seams and the like, as well as any waste material.

(c) Curved profile shall be of any radius that is shown on the relevant drawing.

7
(d) Dimensions shall be measured to the nearest 10mm. 5mm and over shall
be regarded as 10mm and dimensions less than 5mm shall be disregarded.

(e) Except for quantities measured in tonnes (t), quantities shall be given to
the nearest whole number. Quantities of less than one unit shall be given
as one unit. Quantities measured in tonnes (t) shall be given to two decimal
places.

(2) Voids:

(a) Voids which are defined as openings or wants within or at the


boundaries of the measured work are deducted irrespective of size.

3.2. Descriptions

3.2.1. Each Work Section of a BQ shall begin with the name of the Work Section as a top
heading.

3.2.2. The building components/items under each of Work Sections 02-29 shall be
grouped,listed and coded as described in Item 2.3.3 above.

3.2.3. Unless specifically stated otherwise in the BQ or any part of the MySMM, descriptions for
building components/items shall generally include the:

(1) specific type and quality of the material;


(2) critical dimension(s) of the material(s);
(3) nature or type of background; and
(4) goods or materials that are to be incorporated into the work were not at the
discretion of the contractor.

3.2.4. Dimensions given as part of the description or ‘dimensional description’ required to be


replaced with dimension as part of the description shall be:

(1) stated in the sequence: length, width, and height. Where ambiguity could arise,
the dimensions shall be identified in the description; and

(2) the finished lengths, widths, and heights specified or shown on the drawings
with no allowance made for overlaps, scarcements and the like.

3.2.5. Any thickness given as part of the description shall be the finished thickness of the
material after compaction and shall exclude the thicknesses of adhesives and or bedding
materials unless otherwise stated.

8
3.2.6. The use of a hyphen (-) or the phrase ‘to’ between two dimensions in a description shall
mean a range of dimensions exceeding the first dimension stated but not exceeding the
second.

3.2.7. Work with a curve, concave, convex, conical, spherical and the like shape shall be so
stated without the necessity of stating the radius/radii, but such information may be given
by a precise and unique cross-reference to another document e.g. to a specification, a
catalogue or a drawing.

3.2.8. The standard template for the descriptions of building components/items as described in
Item 2.3.3 above is to facilitate both the traditional ways of measurements and for
renovation works though in a simplified manner but its main aim is to reduce the number
of measureable BQ items and the simplification of the measurement of the same to
facilitate the ease of auto-production of ‘usable raw quantities’ from a 3D model in BIM
application. Therefore, to achieve this aim of making MySMM BIM-friendly , the following
methods are adopted in so far that they are possible in drafting the standard template:

(1) the use of composite building components/items which combined separate


components or sub-components to form single composite building
components/items e.g. flush door comprising door itself, door frames,
architrave, painting, etc, tiling comprising, tiles, screeded bed, etc.;

(2) the use of generic terms to group several related building components/items
for measurement as one item e.g. portal frames comprising stanchions, rafters,
struts, chords, etc., narrow width comprising skirting, risers, treads, edges of
slabs, kerbs, etc.,

(3) the use of total depth in stages for excavation work e.g. for foundation
excavation, as ‘not exceeding 2.00m total depth’, ‘not exceeding 4.00m total
depth’ and thereafter in 2.00m stages;

(4) the use of only two stages of strutting based on total height e.g. for formwork to
soffits of slabs and beams, as ‘strutting not exceeding 3.5m total height’,and
‘strutting exceeding strutting 3.5 total height’;

(5) the measurement in ‘m3’ without stating the thickness e.g. concrete to walls,
blinding, slabs, etc, measured in ‘m3’ without stating the thickness, formwork
to sides of foundations, edges of slabs, etc. measured in ‘m2’ without stating
the height, etc.

(6) voids within or the boundaries of the measured work irrespective of size to be
deducted

(7) any curved profile to be stated without the need to state the radius

9
3.2.9. Unless specifically stated otherwise in the BQ or any part of the MySMM, each building
component/item shall be deemed to include the following:

(1) labour and all costs in connection therewith;


(2) materials and goods together with all costs in connection therewith;
(3) assembling, installing, erecting, fixing or fitting materials or goods in position;
(4) plant and all costs in connection therewith;
(5) waste of goods or materials;
(6) all rough and fair cutting unless specially stated otherwise;
(7) establishment charges; and
(8) cost of compliance with all legislation in connection with the work measured
including health and safety, disposal of waste and the like.

3.3. Work of special types:

3.3.1. Work of each of the following special types shall be separately identified:

(1) Work to existing buildings: such work is defined as work on, in or immediately
under buildings or structures existing before the current building project.
(2) Work carried out and subsequently removed;
(3) Work outside the curtilage of the site;
(4) Work carried out in extraordinary conditions, including:

(a) in, on or under water, stating whether river, canal, lake or sea and,
where applicable, stating the mean spring levels of high and low water;
(b) in tidal conditions;
(c) underground, stating mean depth;
(d) in compressed air, stating the pressure and means of entry and exit;
and
(e) in other types of extraordinary conditions.
Specific details pertaining to work carried out in each condition shall be given
at the start of each applicable work section.

3.3.2. The additional rules for special types of work shall be read in conjunction with the rules in
the appropriate Work Sections.

3.3.3. Details of the additional preliminaries that are pertinent to the special types of work shall
be given in the description, drawing attention to any specific requirements due to the
nature of the work.

10
3.4. Measurable work not covered by the tabulated rules:

3.4.1. Building components/items not covered by the tabulated rules shall, if possible, be
measured by rules for similar types of work. Rules of measurement adopted for such
building components/items shall be clearly stated and fully defined in either the
preliminaries or in the BQ (against the building components/items or items to which the
rule relates). Such rules shall, as far as possible, conform to those given in the tabulated
rules of measurement for similar building components/items.

3.4.2. Where it is not possible to derive the method of measurement from the tabulated rules,
the rules chosen may be bespoke. In such cases, the rule or rules derived shall be
reiterated in full in either the preliminaries or in the BQ (above the building
components/items or items to which the rule relates i.e. under “Notes’ preceding the
Heading of the building components/items concerned).

3.5. Procedure where work cannot be quantified:

3.5.1. For the rules relating to work that cannot be quantified and described in accordance with
the tabulated rules of measurement as they cannot entirely be foreseen, defined, or
detailed at the time the tender documents are issued, they shall be given a sum called
‘provisional sum’.

3.6. Procedure where the exact type of product or component is not


specified:

3.6.1. Where the exact type of product or component cannot be specified, an estimated price
for the product or component shall be given in the description as a prime cost unit rate
(P.C. unit rates). State, for example, ‘* at P.C. unit rate of RM * per m for the supply only
by a firm to be selected by the Architect; ……….’,

3.6.2. Unless specifically stated otherwise in the bill of quantities or these rules, the contractor
shall be deemed to have allowed for all items listed in paragraph 1.4.2.11 plus, his
overheads and profit in his period rate for each building component/item incorporating a
PC price with the breakdown of such items given therein.

11
3.7. Procedure where the quantity of work cannot be accurately
determined:

3.7.1. Where work can be described and given in items in accordance with the tabulated rules
of measurement, but the quantity of work cannot be accurately determined, an estimate
of the quantity shall be given and identified as a ‘provisional quantity’

3.7.2. Work items identified as a ‘provisional quantity’ shall be subject to remeasurement when
they have been completed. The ‘approximate quantity’ shall be substituted by the ‘firm
quantity’ measured, and the total price for that item adjusted to reflect the change in
quantity. Where the variance between the ‘provisional quantity’ and the ‘firm quantity’
measured is less than 20 per cent, the rate tendered by the contractor shall not be subject
to review. Where the variance is significant (i.e. 20 per cent or more), the rate can be
reviewed to ensure that the rate is fair and reasonable to both the employer and
contractor.

3.8. Procedure where work or services to be executed by a nominated


sub-contractor, a government or a statutory authority or for materials
or goods to be obtained from a nominated supplier:

3.8.1. A ‘prime cost sum’ shall be provided for such work or services or materials or goods. Such
sum shall be deemed to be exclusive of any profit required and/or attendance to be
provided by the main contractor and provision shall be made for the addition thereof where
applicable.

12
01 PRELIMINARIES

01 PRELIMINARIES

01 Generally
02 Bills and Pricing/Pricing
03 Materials & Samples
04 Form of Contract
05 Statutory Obligations
06 Contract Administration
07 Site Control
08 Temporary Works
09 Completion

SUB-HEADING INFORMATION REQUIREMENTS

01 Generally

01 Definition and Interpretation 01 Function (e.g. architect), name of organisation, address, telephone number and email address to be stated.
To include (where applicable)
(1) Employer
(2) Project Manager
(3) Architect/S.O.
(4) Civil & Structural Engineer
(5) Mechanical & Electrical Engineer
(6) Landscape Architect
(7) Quantity Surveyor
(8) Employer’s Representatives (ER)
(9) Specialists
02 Definition and interpretation of keywords, terms, phrases, and synonyms used in the preliminaries and
specifications.

02 Weight and Measurement 01 Units of weight and measurement to be of imperial or metric format.

03 Singular and Plural 01 Statement of words importing the singular only also include the plural and vice versa where the context requires.

13
01 PRELIMINARIES

SUB-HEADING INFORMATION REQUIREMENTS


04 Abbreviations 01 Long form of abbreviations used in the Contract Documents.

05 Firm Price Tender 01 Definition of Firm Price Tender.

06 Lump Sum Tender 01 Definition of Lump Sum Tender.

07 Contract Documentation 01 The cost of preparation of contract documents, who to bear and mode of payment.
Charges

08 Preliminary Items 01 Basis of pricing the Preliminary Items.


02 Method of evaluation for Preliminary Items for the purpose of the progress payment.

09 Site 01 Address of the project site.


02 Reference to a key plan, 'as found', visiting site, means of access, storage of materials and goods, working space,
existing services, etc.
03 Compliance to authority regulations and traffic management.

10 Preambles, Specification, and 01 Statement that description of work and materials in the Bill of Quantities and their pricing are to be read in
Drawings conjunction with the preambles, specification, and drawings.

11 Adjacent/ Adjoining Properties 01 Care to be taken to adjacent/adjoining properties.


02 Security and trespassing to adjacent/adjoining properties.
03 Reduction of various environmental disturbances.
04 Inspection of adjacent/adjoining properties with the relevant parties.
05 Liability for any damages or other disturbances caused.

12 Restricted Site 01 Definition of restricted site and precautions to be taken.

13 Languages 01 Requirements of language in which the Contract Documents shall be drawn up.

14 Documents Mutually 01 Obtaining of the S.O. clarification on the differences between the drawings and conditions on site and carrying out
Explanatory Works in accordance with instructions as may from time to time be issued by the S.O.

14
01 PRELIMINARIES
SUB-HEADING INFORMATION REQUIREMENTS
15 Soil Investigation 01 Where the soil investigation report is available.
02 Statement that soil investigation report not forming part of the Contract.

16 Works Already Executed by 01 Description of the works already executed by others and the requirements for the protection of the same and offer
Others of assistance with no extra cost.

17 Co-ordination with Other 01 Co-ordination with other contractors employed on the site.
Contractors Employed on the
Site

18 Brief Description of the Works 01 Brief description of the Works.

19 Mock-Ups 01 Completeness of the mock-up unit to be chosen by the Architect and the time frame for completion.

02 Bills and Pricing (applicable for BQ Contract) / Pricing (applicable for ‘Lump-sum’ Contract)

01 Bills of Quantities 01 Measurement of Bill of Quantities in accordance with the 'Malaysian Standard Method of Measurement (MySMM)
(applicable for BQ contract) for Building Works' for use in Malaysia, (to state Edition) published by the Royal Institution of Surveyors Malaysia.
02 Usage of the Bill and its ‘Quantities’.

02 P.C. Unit Rates for Supply of 01 Meaning of P.C. Unit Rates for the supply of goods and materials and their contractual treatment.
Goods or Materials

03 Pricing of Bills of Quantities 01 Treatment of any item left blank in the Bill of Quantities.
(applicable for BQ contract)

04 Elemental Bills of Quantities 01 Preparation of the Bill of Quantities in the ELEMENTARY FORM that is in functional order rather than trade order
(applicable for BQ contract) and within each element the items have been set out in Trade Order.

05 Preparation of Tenders 01 Requirements in respect of the submission of tender documents.


02 Inclusiveness of the tender.

15
01 PRELIMINARIES
SUB-HEADING INFORMATION REQUIREMENTS
06 Works Included in the Contract 01 Constituent costs of all item prices for the Works included in the Contract.

07 Condition of Tender 01 Disqualification of the tender when the Contractor was to submit conditions in contravention to those contained in
the tender documents.

08 "Allow" 01 Definition of 'Allow'.

09 Pricing of Preliminaries 01 Payment method for additional preliminaries for approved extension of time.

10 Fix the Only Item Supplied by 01 Costs comprised under "Fix Only' items supplied by Nominated Supplier.
Nominated Supplier

11 Inspection of Site 01 Inspection of the site before submitting the tender in relation to the surrounding, nature of the ground, hydrological
and climatic conditions, the form and nature of the site, means of access to the site, the accommodation, etc. and
all necessary information i.e. risks, contingencies and other circumstances that may affect the tender.

12 Sufficiency of Tender 01 Requirements to be satisfied as to the correctness and sufficiency of the Tender.

03 Materials and Samples

01 Materials and Samples 01 Whole of the materials, goods, and workmanship throughout the Works in compliance with the requirements of
Malaysian Standards (MS) or relevant British Standard (BS) Code of Practice (to state other Standard if any)
current at the date of closing of tenders.

02 Sample of Materials 01 Submission of samples and/or test certificate of materials or the execution of samples of workmanship for
approval by the S.O.

03 Employer's Right to Supply 01 Situations whereby the Employer has the right to supply materials.
Materials 02 Requirements if the Employer supplies the materials.

04 Testing of Sampled and 01 Testing of sampled and completed works by the Contractor.
Completed Works

16
01 PRELIMINARIES
SUB-HEADING INFORMATION REQUIREMENTS
05 Ordering 01 Ordering specified materials by the Contractor.

06 Substitute Materials 01 Conditions for the acceptance of the substitute materials by the S.O.

04 Form of Contract

01 Form of Contract 01 Full title of the standard or bespoke form of contract, including edition, revision, and standard amendments
applicable.
02 Schedule of clause/condition headings in the standard form of contract.
03 Reference to any amendments to clauses/conditions to standard form of contract.
04 Reference to any supplementary or special clauses/conditions to standard form of contract.
05 Insertions to Appendix to Contract.
06 Where bespoke, or uncommon form of contract is used - a copy is to be appended to the bill of quantities or
included as part of the tender.

05 Statutory Obligations

01 Taxation 01 Payment of Malaysian taxes under the laws for the time being in force.

02 Registration of Workmen with 01 Registration of Workmen with the Department of Labour.


Department of Labour

03 Workmen Identification Card 01 Requirement of the Workmen Identification card.

04 On-Site Training Scheme 01 Compliance with the requirements of any on-site training scheme which may be by the Authorities and/or
Government.

05 Custom Restriction, Quotas, 01 Compliance to all custom restrictions, quotas and duties and bearing costs arising therefrom.
and Duties, etc. 02 Liability for all increases in import duty, tariffs and taxes, etc. that may arise during the duration of the Contract.

17
01 PRELIMINARIES
SUB-HEADING INFORMATION REQUIREMENTS
06 Employment of Labour 01 Payment of all emoluments and expenses in compliance with the Employees Provident Fund Ordinance Act 1991
Generally or any other provision by Statute, Tort or Common Law or legislation concerning the employment of labour.
02 Employment of skilled and experienced persons in their respective trades.
03 Employment of sub-contractors and ensuring only skilled and experienced persons in their respective trades are
employed in connection with the Works under the Contract.

07 Employment of Foreign 01 Compliance with rules and requirements of the immigration laws of the country.
Workers and Specialists 02 Any other special requirements.

08 Environmental Policy 01 Compliance with the Environment Quality Act 1974 and development and implementation of an Environmental
Quality Management (EQM) programme for the Works.

09 Construction Industry 01 Compliance with Part VIII of the Lembaga Pembangunan Industri Pembinaan Malaysia Act 1994 and the
Development Board (CIDB) Construction Industry (Levy Collection) Regulations 1996.

10 Occupational Safety and 01 Compliance with the Occupational Safety and Health Act 1994 and provision of all necessary safety precautions.
Health Act

11 Permits and Licences 01 Obtaining all necessary permits and licence etc. required from the relevant authorities in connection with the
carrying out of the Works and pay all fees and royalties in connection therewith.

12 Tax Incentives Obtained by the 01 Obligations of the Employer to apply for tax incentives from the Government of Malaysia in respect of the Works
Employer (or the project for which the Works form a part) in the form of tax exemption, tax credit, tax benefits or any other
form.

13 Withholding Tax Legislation 01 Payment of all withholding tax in accordance with the Withholding Tax Legislation (under Section 107A to the
Income Tax Act 1967) in the case of non-resident contractors.

18
01 PRELIMINARIES
SUB-HEADING INFORMATION REQUIREMENTS

06 Contract Administration

01 Time Essence of the Contract 01 Whether time is of the essence of the Contract.

02 Drawings 01 Carrying out of the whole of the works in accordance with the dimension and sizes shown on the Architect and
Engineer drawings.
02 Checking for missing drawings, discrepancies between drawings, and between drawings and conditions on site,
and seeking clarifications from the S.O. in due time.

03 Co-ordinated Working 01 Preparation of fully co-ordinated working drawings, specifications and all requirements of all the sub-contractors
Drawings prior to commencement of the relevant work at the site.
Preparation of working drawings (Architectural, Mechanical & Electrical, and Consultants' drawings) including all
the requirements.
Clarifications of work to be accomplished by means of the following:
a. Large scale details
b. Detailed dimension computed from overall dimensions shown upon drawings
c. Combining details shown on several drawings
d. Transforming tables, schedules, and written information into a visual form of sketches and diagrams
e. Providing the field personnel with relevant drawings and all the information for them to accomplish their
portion of the work

04 Records Drawings 01 Keeping of accurate records of the Works, or as may be directed by the S.O.

05 Weekly Reports 01 Submission of weekly reports on the progress of the works to the S.O. including the elaboration of daily activities
of the site.

06 Neglect to obtain Reliable 01 Obtaining on the spot or elsewhere of reliable information about the various respects of the Works which may
Information affect the tender and no claim for any negligence or failure to do so.

07 Logistic Plan 01 Establishment of and implementation of a Logistic Plan and the operational strategy describing the overall site
facilities and services that will be provided to ensure that the construction works proceed smoothly and safely, with
minimum impact on surrounding areas; all to the S.O.’s approval.

08 Site Meetings 01 Attendance of site meetings arranged by the S.O. whenever appropriates.

19
01 PRELIMINARIES

SUB-HEADING INFORMATION REQUIREMENTS


09 Meeting Requirements 01 Compliance with the requirements set out in respect of the Project Co-ordination Meetings, Site Meetings, and
Sub-Contractors' Meetings.

10 Advertising 01 Reservation of the sole right of advertising upon or adjacent to the Works to the Employer.

11 Progress Photographs 01 Submission of progress colour photographs before the commencement of the works and thereafter at monthly
intervals.

12 Programme and Manpower 01 Submission of a construction programme and manpower chart related to the construction period showing the
Chart order or sequence to carry out the various parts of the Works and any proposed temporary works or methods of
working which may be relevant to progress before commencement of the Works.

13 Quality Assurance and Quality 01 Implementation of quality assurance systems in accordance with the details set out in the Specification and/or as
Control approved by the S.O.

14 Financial Report 01 Submission of a Progress payment `S’ curve which shall have a horizontal time-scale showing the Contract
Completion Period in months and a vertical monies-scale showing the Contract Sum before commencement of the
Works and thereafter at monthly intervals

15 Programming, Scheduling and 01 Submission of work programming, scheduling. and monitoring.


Monitoring Requirements

16 Safety, Health, and Welfare of 01 Establishment of a Safety and Health Plan to ensure that all construction activities required to facilitate the
Work People execution of the Works are carried out in a safe manner, consistent with proven good practice, and comply with
the Acts.

17 Delays 01 Allowance for all possible delays caused by difficulties in obtaining labour and materials or by suspension of part
or whole of the Works due to adverse weather conditions other than exceptionally inclement weather.

18 Failure to Achieve 01 Modification to or replacement of the whole or any part of an installation forming part of the Works which fails to
Performance produce on test the performance offered without any extension of time and at own cost.

19 Dismissal by Request 01 Dismissal immediately from the Works of any person employed on site who may in the opinion of the S.O. be
incompetent or misconduct himself.

20
01 PRELIMINARIES
SUB-HEADING INFORMATION REQUIREMENTS
20 Attendance Provided By 01 Provision of the Attendance as defined in the tender document by the Contractor to the Nominated Sub-
Contractor to Nominated Sub- contractors with which the Contractor shall enter a binding sub-contract with the respective Nominated Sub-
Contractors contractors appointed under the P.C. Sum provisions of the Main Contract.

21 Confidentiality 01 Keeping of all information, documents and all other matters arising or coming to their attention in connection with
the Contract secret and confidential.

07 Site Control

01 Constructional Plant and 01 Provision of construction plant in sufficient number.


Equipment 02 Provision of full details of proposed construction plant.
03 Strengthening of structure to carry extra loads imposed by the construction plant.
04 Making good any damage to the permanent structure which may be caused by the construction plant.

02 Loading in Excess of Design 01 Measures against excess loading on structural members and to bear costs arising therefrom including making
Load good any damage caused.

03 Noise and Nuisance 01 Measures to ensure that all noises, vibrations, etc. emitting from the Works shall be kept to an absolute minimum.
02 Compliance with all reasonable requests to reduce noise and dust pollution, and all authority notices.

04 Damage to and maintenance 01 Liability to damage caused to any existing roads, culverts, roadways and footpaths, drains and watercourses and
of Existing/public Road(s) public utility and other services on or adjacent to the site from whatsoever cause arising liability for all cost of
making good any damage, maintenance, repair and reinstate same to their original condition to the satisfaction of
the S.O. or the relevant authorities.
Compliance with all police regulations; keeping all public highways and footpaths, clean and free from sand,
builder's rubbish, debris, etc. occasioned by the Works throughout the period of the Contract and liability for all
charges and imposition of fine.
Keeping of the public roads from building debris and spoil due to the movement of transportation to and from the
site and be responsible to pay any fine imposed by the Authority resulting from negligence.

05 Protection of Public and Protection, upholding and maintaining all public and private services within the site; in accordance with the
Private Services authorities’ requirements and obtain any necessary approval; bearing all costs of making good any damage
arises.

21
01 PRELIMINARIES

SUB-HEADING INFORMATION REQUIREMENTS


06 Obstruction of Road(s) 01 Ensuring reasonable and convenient assess of roads for the public; obtaining approval of S.O. and relevant
Authorities for any roads to be blocked or obstructed.

07 Restriction of Persons to Site 01 Responsibility of restricting all unauthorized persons to the site and establishing a proper recording system and
safety gear for authorized visitors.

08 Trespass 01 Liability for any claim resulting from a civil court action due to infringement of air space or land of adjoining
owners.

09 Working Hours 01 Compliance with all Rules and Regulations affecting work and labour and the National/Public Holidays of the
State.

10 Overtime for Supervisory Staff 01 Organizing and programming of any work to be carried out within the stipulated working hours for site Supervisory
Staff as well as obtaining the written permission of the S.O. for necessary cases such works are required to be
carried out beyond the stipulated hours.

11 Mosquito Prevention and Post 01 Keeping dry of all excavations and parts of the site where water stagnates or accumulates by means acceptable to
Control the S.O.
02 Taking relevant precautions as may be deemed necessary or desirable by the S.O. for the prevention of breeding
of mosquitoes and pest control

12 Keeping Site Dry 01 Keeping the whole of the works well-drained and free from all water (including rain, storm, spring and running
water and water below the Water Table Levels) at all times to ensure that all work is carried out in the `dry'.

13 Silting 01 Keeping all drains, stream, and waterways free from mud, silt and other obstructions and making good where
necessary to the satisfaction of the S.O. during the currency of the Contract.

14 Prevention of Earth Slope 01 Taking all necessary precautions to preserve all earth slopes, both existing i.e. slopes already existing on the site
at the time of the site being handed over to the Contractor and new i.e. slopes formed and constructed under the
Contract.

15 Site Security 01 Provision of all necessary and adequate watching by day and night for the throughout the course of the Works..

22
01 PRELIMINARIES

SUB-HEADING INFORMATION REQUIREMENTS


16 Safety Programme 01 Establishing of a safety plan to ensure that all construction activities required to facilitate the execution of the
Works are carried out in a safe manner, consistent with proven good practice.
02 Compliance with all laws, regulations, codes of practice and other thing relevant to safety which may from time to
time apply to the Works.

17 Safety Measures 01 Ensure for the complete adequacy of all protective systems to workmen and the public and comply in full to the
requirements laid down in the Local By-Laws and any future regulations or by-laws regarding safety measures
applicable in Malaysia.

18 Quality Assurance, Quality 01 Development of and implementation of a Quality Assurance Plan in compliance with the latest International
Control, and Testing Organization for Standardization's Standard ISO 9001 and MS ISO 9001.

19 Protection of Environment 01 Taking all steps to protect the environment on and off site ; avoiding damage or nuisance to persons or to
property of the public or others resulting from pollution, noise or other causes arising from the Works.
02 Compliance with the Environmental Management Practice as specified in the Specification for the protection of the
environment.

20 Fire Protection during 01 Taking of proper precautions to minimise the risks of fire whilst the Works are under construction including
Construction providing a wet or dry riser in working order ; all in compliance with all UBBL requirements.

21 Adequate Ventilation during 01 Provision of all necessary equipment and power for ventilation purposes during construction, and clearing away all
Construction apparatus when no longer required..

22 Protection of Materials and 01 Provision of all things necessary for the proper protection of materials and completed work and reinstating at own
Completed Work cost any damage or loss.

23 Overtime and Completion 01 Completion of the whole of the Works by the time stated in the Contract and no extra will be allowed in respect of
overtime paid to achieve this.

24 Covering Up 01 Covering up of any part or parts of the Works or making openings in or through the same subject to prior
inspection and approval by the S.O.

25 Antiquities 01 Discovery of any old curiosities, relics, coins, etc. found in excavation or other execution of work to be handed
over to the S.O.
02 Notification of discovery of ancient masonry, pavements or other old work of interest to be made to the S.O. before
their demolition or removal.
23
01 PRELIMINARIES

SUB-HEADING INFORMATION REQUIREMENTS


26 Access and Egress 01 Adherence strictly to the access and egress points shown on the drawings or such other access and egress
points approved by the Local Authorities.

27 Work done by Statutory Bodies 01 Clearing away of all rubbish and debris left and making good acts of his works disturbed by these bodies to the
complete satisfaction of the S.O.

28 Use of Services Lifts for 01 Observance of the carrying capacity of the lifts as set down by the Lift Manufacturer and obtaining of consent from
Construction Purposes the S.O. to use the lift cars either as passenger hoists or good hoists..

29 IBS - Industrialised Building 01 Adherence to the IBS Content Scoring system based on CIDB's CIS 18:2010 Manual for IBS Content Scoring
System for Building System (IBS Score) as a standard method of assessment to achieve a score of at least 50% for components of
Construction Work (GBI-FR; work under the Contract.
SM7)
30 Dilapidation 01 Conducting of a dilapidation survey of surrounding buildings, structures and properties by a Registered Building
Surveyor.
02 Making good all consequential damages to the surrounding arising from ground movements and vibration caused
by the works.

31 Settlement and Ground 01 Assessment of the settlements and ground movements due to execution of the works.
Movements 02 Installation and maintenance of piezometers and inclinometers for checking of the water table and ground
movement during construction.

32 Monitoring/Protecting Slope 01 Method adopted to monitor the soil movement, and the temporary work to protect/support the slope, excavation
Stability and the like.
02 Liability in the event of any failure of slopes, sides of excavation and the like.

33 Monitoring Ground Water 01 Method adopted to monitor the groundwater table until it would not affect the integrity of the adjoining buildings.
Table

08 Temporary Works

01 Temporary Crossing 01 Construction of temporary crossing over drains, and/or channels, footways, kerbs, etc. and removal upon
completion and making good to the satisfaction of Local Authority or paying charges.

24
01 PRELIMINARIES

SUB-HEADING INFORMATION REQUIREMENTS


02 Temporary Culverts, Tracks, 01 Construction of temporary culverts, tracks, etc. for access to site and removal upon completion and making good
etc. to satisfaction of the S.O.

03 Temporary Drains 01 Construction temporary drains to keep the site free from water in accordance with the relevant drawings and in
compliance with the Local Authority's requirements.

04 Existing Services 01 Notification to Service Providers, Local Authorities and/or adjoining adjacent owners and for actions to be taken
when the works encountered existing services.
02 Liability for damage occurred to existing services.
03 Scope of diversion of the existing services.

05 Temporary Lighting and Power 01 Provision of adequate temporary lighting and power in compliance with Electrical Service Provider's requirements.
02 Paying all costs and charges, deposits, etc.

06 Water 01 Provision of water and its quality.


02 Application and notices and paying all charges.

07 Temporary Fencing and Gates 01 Provision of temporary fencing and gates as shown in the relevant drawings.
02 Obtaining licence and paying all charges.

08 Vehicles for Site Supervisory 01 Full specification of each vehicle required.


Staff 02 Timing for their requirements and paying all maintenance, insurance, running costs, etc.

09 Materials Testing Laboratory 01 Specific requirements in respect of size and equipment.


and Staff 02 Provision of staff.
03 Payment of all maintenance, running costs, etc. and removal on completion including all laboratory equipment.

10 Surveying Equipment for the 01 Provision of surveying equipment and the protective items.
Engineer

11 Site Staff's Site Office 01 Requirements in respect of size, amenities, and furniture and equipment.
02 Payment of all maintenance, running costs, etc. and removal on completion.

25
01 PRELIMINARIES

SUB-HEADING INFORMATION REQUIREMENTS


12 Site Office for Employer and 01 User requirements in respect of functionality of the room/workspace, inclusive of FF&E list, necessary personal
Consultants protective equipment, fire-fighting equipment., telecommunication and IT system, etc.
02 Payment of all maintenance, running costs, etc. and removal on completion.

13 Survey Operatives for The 01 Provision of chainmen and labourers.


Engineer

14 Water Quality Supervision 01 Water quality supervision for all streams and rivers at locations as directed, to the satisfaction of the relevant
Authority.
02 Sampling.

15 Workmen Accommodation, 01 Provision of workmen accommodation, temporary stores, sheds and sanitation facilities canteen with necessary
Temporary Stores, Sheds and water and drainage system and septic tank to comply with Authorities’ requirements.
Sanitation Facilities 02 Payment of all fees, maintenance, running costs, etc. and removal on completion.

16 Sheds etc. 01 Provision of sheds, etc. in compliance with the Authorities’ requirements.
02 Payment of all fees, maintenance, running costs, etc. and removal on completion.

17 Walkie-Talkie 01 Number of sets of walkie-talkies for use by site supervisory staff during the full period of the works.
02 Payment of all charges for permits including renewal of permits from all relevant Authority.

18 Signboard 01 Provision of signboard to Authority's requirements and/or as shown in the relevant drawings
02 Payment of all charges for permits including renewal of permits from the relevant Authority.
03 Repair and repainting of the signboard on a timely basis and shifting of signboard whenever required.

19 Passenger Hoist and Tower 01 Provision of passenger hoist and tower crane of approved capacity and boom length complete with lightning
Cranes protection and in compliance with the Authorities' requirements. Payment of all charges and fees including the
02 renewal of the licenses, maintenance, running costs, etc. and removal on completion.

20 Plants and Machinery 01 Provision of plants and machinery for the Works.
02 Payment of maintenance, running costs, etc. and removal on completion.

26
01 PRELIMINARIES

SUB-HEADING INFORMATION REQUIREMENTS


21 Debris Chutes 01 Provision of adequate debris chutes for the discharge of debris and superfluous material at approved locations.
02 Avoidance of nuisance to public and owners of adjoining buildings.

22 First Aid Facilities 01 Provision of suitable size first aid facilities for the use of all site staff.

23 Temporary Aircraft Warning 01 Provision of temporary aircraft warning lights on tower cranes to Authority's requirements and approval.
Light

24 Site Fire Prevention and Fire 01 Institution of fire prevention and fire-fighting measures.
Fighting Facilities
02 Institution of awareness among all site staff from the respective parties.

25 Temporary Safety Netting and 01 Requirements to allow for providing and maintaining all necessary protective netting, catching platforms and/or
Catching Platform other measures deemed necessary to the whole of the Works for the safety of the workmen and protection of the
public and properties.

26 Scaffolding for All Trades 01 Supply and erect all necessary temporary scaffolding and special scaffolding, shoring, staging, planked footways,
guard rails and the like for the use of workmen in accordance with the Ordinance and By-Laws; and remove all
scaffolding and plant when no longer required.

27 Walkie-Talkie 01 Number of sets of walkie-talkies for use by site supervisory staff during the full period of the works.
02 Payment of all charges for permits including renewal of permits from all relevant Authority.

10 Completion

01 Removal of Rubbish 01 Keeping the site and buildings, adjacent roads and footpaths, etc. clean during the construction and at
completion.
02 Erection of rubbish chute.

02 Completion 01 Removal of all plant, temporary buildings, sheds, building appliances, apparatus or equipment, etc from the site,
disconnection of all services and leaving the site in a clean and orderly condition.

27
01 PRELIMINARIES

SUB-HEADING INFORMATION REQUIREMENTS


03 As-built Drawings 01 Submission of “as-built” drawings for the Works comprising plans, sections, and elevations in respect of the
Works within six (6) weeks from the date of the issue of a Certificate of Practical Completion to the S.O.

04 Operating and Maintenance 01 Submission to the S.O. six (6) complete sets of operating and maintenance instructions for items incorporated in
Instructions the Works before issuance of Certificate of Practical Completion

05 Defects After Completion 01 Inspection of the works at the end of the Defects Liability Period.

06 Warranties or Guarantees 01 Submission of warranties or guarantees as specified in the Contract within two (2) Weeks from the Date of
Practical Completion of the Works to the Employer.
Assignment to the Employer the benefit of any guarantees and/or quotations for future maintenance when such
02 guarantees and/or quotations extend beyond the Defects Liability Period of the Main Contract.

05 Defects After Completion 01 Inspection of the works at the end of the Defects Liability Period.

28
02 IBS
02 IBS

01 Pre-cast Concrete
02 Formwork
03 Steel & Metal Frame Truss
04 Timber Frame
05 Blockwork
06 Innovative

Information to be provided in the 1. Precast Concrete (if CIDB catalogue is used)


Specification a. CIBD's user guide: IBS catalogue for Precast Building System & User manual for components selection.

2. Formwork
a. Refer to Work Section 09: Insitu concrete works.

3. Blockwork
a. Refer to Work Section 11: Masonry.

4. Proprietary Systems i.e. 'Steel & Metal Frame Truss', 'Timber Frame' and 'Innovative'
a. Performance Specification covering the following:
(i) Scope of work (vi) Performance criteria
(ii) Submittals (vii) Delivery, storage and handling
(iii) Codes and standards (viii) Materials
(iv) Design requirements (ix) Fabrication and installation
(v) Testing (x) Warranties

Specific information to be shown 1. For Pre-cast Concrete


in the drawings or to be input into a. Various pre-cast concrete components with the respective codes extracted from an approved IBS catalogue
the 3D models selected to be used for the different structural parts of the building/structure.
b. Grade of concrete and reinforcement details of concrete topping (if any).

2. For Formwork & Blockwork


a. Refer to Work Section 09: Insitu concrete works and Masonry respectively.

29
02 IBS
Specific rules of measurement 1. Provision of tower cranes, crawler cranes, mobile cranes, etc. and other plant and equipment necessary for the
installation of IBS system are described in the 'Preliminaries' Bill.
2. Voids irrespective of sizes is to be deducted.

Works and materials deemed 1. Pre-cast Concrete


included which are collectively a. All precast concrete components is deemed to include the following:
referred to as the 'Preambles' (i) Reinforcements and projecting reinforcements for lapping into the main structure
(ii) Lifting hooks
(iii) Moulds and casting
(iv) Keyed finish to external surfaces to receive tiling and fair finish to all other surfaces
(v) Cast-in brackets, plates, U-bars, stainless steel bolts washers and brackets, etc. welded or built into the
main structure
(vi) Holes, sleeves, rebates, notching, sinking, mortices and the like
(vii) Hoisting, placing in position, setting, bedding, jointing and pointing in cement mortar and/or grouting with
non-shrink cement and sand mortar including cutting-off lifting hooks
(viii) Temporary supports, ties, etc
(ix) Concrete packing before fixing of precast units in position
(x) Neoprene or plastic spacer tubes and applying silicone sealant to all joints
(xi) All making good
(xii) Casting in conduits, forming, forming chases, opening, holes, etc and the likes for Mechanical and
Electrical installation All rough
(xiii) Adjustments to the precast components to suit the Architectural design and profiles
(xiv) Supply which is to include delivery transportation, protection, unloading to site for storage and double
handling

2. When IBS is based on 'Design & Build', the following is deemed to be included:
a. The design shall in all respect adequate, accurate, sufficient and fit for its purpose.
b. Submittal of all shop drawings and design calculations endorsed by Professional Engineer registered with the
Board of Engineer, Malaysia.
c. The design shall be based on IBS components selected from the approved IBS Catalogue Pre-Cast Concrete
Components for Building Work.
d. The pricing of the IBS system shall follow the breakdown given in the Tabulated Form for description of
component/item description but on 'lump-sum for each item.
e. Requirements to furnish warranty period of (to state the years and from when).
f. Other requirements (if any).

30
02 IBS
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary

01 Pre-cast Concrete from 'IBS Catalogue Pre-Cast Components for Building Work ' published by (to name publisher)

01 Precast Concrete nr 01 Precast Concrete 01 (dimensional 01 If 'sloping' irrespective of


Frame Structures Frame description) square the degree of slope, it shall
columns (code nr.); as be so described in Level
shown in the drawing Two.
(drawing nr.)/model 02 Code nr.' is obtained from
02 (dimensional the selected IBS
description) catalogue.
rectangular beams
(code nr.); as shown
in the drawing
(drawing nr.)/model
03 (dimensional
description) L-shaped
beams (code nr.); as
shown in the drawing
(drawing nr.)/model
04 (dimensional
description) T-shaped
beams (code nr.); as
shown in the drawing
(drawing nr.)/model

31
02 IBS
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
02 Precast Concrete m2 01 Hollow Core Slabs 01 (thickness) thick; 01 If sloping slabs irrespective
Decking 02 Precast Concrete (code nr.); as shown of the sloping degree, it
Half Slabs in the drawing shall be so described in
(drawing nr.)/model Level Two.
02 Code nr.' is obtained from
the selected IBS catalogue

m3 03 Vibrated reinforced 01 make-up strip to edge 01 All necessary formwork is


in-situ concrete; of Hollow Core Slabs deemed included.
Grade C (grade) P 02 and perimeter beams
in (thickness) thick
concrete topping
03 (width) wide gap and
(height) high ({max.
height} beam infill

kg 04 High tensile steel 01 in concrete topping


bar reinforcement slab
02 in make-up strip

m2 05 Fabric reinforcement 01 in concrete topping


BMC (type) cut to slab
size well lapped at
joints and
embedded.

03 Precast Concrete nr 01 Cladding panels 01 (dimensional 01 Horizontal, vertical or


Walls, Partition and description) panels sloping shall be so
Panels (code nr.); as shown described in Level Two.
in drawing (drawing 02 Code nr.' is obtained from
02 Wall panels nr.)/model the selected IBS catalogue

32
02 IBS

ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
04 Precast staircase nr 01 Straight flight 01 (dimensional 01 'nr' means a flight of
02 U-flight description) steps stairs.
03 L-flight (code nr.); as shown in 02 Code nr.' is obtained
04 Spiral drawing (drawing from the selected IBS
nr.)/model catalogue

02 Formwork

Refer to 'Formwork' under Work Section 09: Insitu concrete works.

03, 04, 06 Steel & metal frame truss & Timber frame & Innovative

For these Proprietary Systems, Item (2) of “Works and material deemed included which are collectively referred to as 'Preambles'” of this Work Section shall
apply.

05 Blockwork

Refer to Work Section 11: Masonry.

33
03 DEMOLTION, ALTERATIONS, REPAIRS AND CONSERVATION
03 DEMOLITION, ALTERATIONS, REPAIRS AND CONSERVATION

01 Demolitions
02 Alteration Work to Existing Buildings
03 Repairs/Cleaning/Renovating and Conserving
04 Decontamination

Information to be provided in the 1. General


Specification 2. Demolition works
3. Alteration and repair work
4. Conservation work
5. Removal of debris or rubbish
6. Overload existing structure
7. Protection works
8. Trees protection
9. Defect survey and mapping
10. New work

Specific information to be shown 1. For Demolitions, the approximate size and the nr. of storeys of existing buildings to be demolished and whether
in the 2D drawings or to be input up to the lowest floor level only or including the ground floor slabs and foundation; for partial demolition, the
into the 3D models types of structures and/or finishes and/or the mechanical and plumbing services and electrical services, etc. to
be demolished and at which levels; listing of salvaged materials which have credit values.
2. For alteration work to the existing building, ‘removing', 'cutting and forming', 'cutting back projections', 'cutting
back to reduce thickness', 'filling in existing openings' and/or any other type to be shown on the parts of the
building where they are required.
3. For repair/cleaning/renovating/conserving, 'repairing', 'repointing', 'resin impregnation/injection', 'cement
impregnation/injection', re-dressing existing flashings and the like', 'damp proof course renewal/insertion',
'cleaning surfaces', 'renovating and conserving' and any other type to be shown on the parts of the building
where they are required.

34
03 DEMOLTION, ALTERATIONS, REPAIRS AND CONSERVATION

Specific rules of measurement 1. All measurements are nett and do not include any additional area required for working space, etc.
2. The lowest level will include basements.
3. If a floor slab is to be removed, then the lowest level which can be the ground floor or the lowest basement
level (as the case may be) must be stated as to the underside of that slab.
4. The rules within this Work Section do not apply to temporary works.

Works and materials deemed 1. Providing, erecting, altering, adapting and maintaining and removing on completion to the satisfaction of the
included' which are collectively S.O. all necessary shoring, needling and strutting, watering to lay the dust, providing dust sheets, tarpaulin,
referred to as 'Preambles' temporary roof covering, water, chutes, screen sand and any other protection necessary to safeguard the
existing and adjoining works, and clearing away all rubbish and making good all works disturbed.
2. Remove’ shall include cutting out or taking apart as may be necessary for the removal of the items described,
drawing all screws, nails, hooks, clips, bolts and other fastenings including grounds, hackings, and the like
and making good surfaces where applicable.
3. Demolition of walls, partitions, ceilings, floor slabs and the like shall include for all associated finishes,
pipework and cabling, etc. whether concealed or surface mounted, switches, sockets, etc.
4. Making good' shall mean to reinstate to as close to its original conditions as possible and to match existing
works so as to avoid visible junction.
5. Compliance with the Dilapidation Survey, Historical Architecture Building Survey (HABS) (if applicable),
Drawings, and Specification.

35
03 DEMOLTION, ALTERATIONS, REPAIRS AND CONSERVATION
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary

01 Demolitions

01 Demolishing item 01 Whole buildings as 01 Down to the level of 01 removing all debris 01 If there is temporarily
listed below and as the top surfaces of the from site diverting, maintaining or
shown in the drawing lowest ground slab 02 leaving the following sealing off existing
(drawing nr.): (to list Including breaking up materials as the services, it shall be so
the approximate grounds slab and property of described in Level Two.
dimension and nr of foundations Employer: (to list) 02 For 'Parts of structures', if
storeys of the only certain floor/s shall
buildings to be 03 setting aside the be affected, the level of
demolished) following materials such floor/s shall be
for re-use at the 03 identified in Level Two:
designated area To add “NOTES’ after
within the site : (to name of each group of
list) the building
components/items as
02 Parts of structures 01 In-situ reinforced follows:
concrete flat roof (a) The Contractor shall
(thickness) thick satisfy himself as to the
nature of works and
make good all works
disturbed as necessary.
(b) The Contractor will
02 In-situ reinforced be required to repair
concrete upper floor or replace at his
(thickness) thick own expense any
03 Precast concrete plank parts or complete
upper floor (thickness) items which in the
thick opinion of the S.O.
have been damaged
as a result of
insufficient care in
removing, handling
and protecting.

36
03 DEMOLTION, ALTERATIONS, REPAIRS AND CONSERVATION

ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
04 Reinforced concrete (c) The demolition,
staircase (nr.) total rise, alterations, repairs and/or
(width) wide, in (nr.) conservation works shall
flight with (nr.) half be executed in such a
landing manner that there will be
05 Pitched roof, timber a minimum of
construction inconvenience and noise
(dimensional and dust pollution to
description) {measured occupants or to the
on plan} public.
06 Brick/block internal
walls (thickness) thick
07 Brick/block external
walls (thickness) thick
08 Floor finishes; (type)
09 Ceiling finishes; (type) (d) The Contractor shall
10 Ceiling finishes; (type) examine the drawings,
11 Doors, windows and the visit the site, inspect the
like existing premises and
12 Sanitary fittings; (type) satisfy himself as to the
nature and extent of the
work to be demolished,
altered, repaired and/or
conserve. No claim for
extra payment in this
respect will be
entertained.
Any other requirements.

37
03 DEMOLTION, ALTERATIONS, REPAIRS AND CONSERVATION

ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
02 Credit item 01 Credit for salvaged 01 (list all items which
materials which have a credit value)
become the property
of the Contractor

02 Alteration Work to
Existing Building

01 Removing item 01 Existing floor 01 Granolithic paving 01 removing all debris 01 The surveyor shall
finishes from site. choose the unit most
---- 02 Mosaic tiles suitable for the type of
work being removed.
m2 03 Ceramic/porcelain tiles 02 leaving the 02 If removal of screeding
following materials under the
---- 04 Terrazzo tiles as the property of finishes/coverings is
Employer: (to list). required, it shall be so
described in Level Two.
m 05 Marble slabs 03 If there are skirtings, their
---- 06 Granite slabs 03 settings aside the removal shall be deemed
following materials included.
nr 07 Carpet flooring/tiles for re-use at the 04 If not all finishes at every
08 Vinyl tiles designated area part of the existing
09 Parquet/ timber flooring within the site: (to building are to be
list). removed, then the floor
level where such removal
is required shall be so
described in Level Two.
05 If 'making good
structures and preparing
a surface to receive new
finishes/coverings' is
required, it shall be so
described in Level Three.

38
03 DEMOLTION, ALTERATIONS, REPAIRS AND CONSERVATION

ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
02 Existing wall finishes 01 Mosaic tiles 06 If there are cornices,
02 Ceramic tiles their removal shall be
03 Marble slabs deemed included.
04 Granite slabs 07 For 'doors', whether they
05 Plaster are 'single' or 'double'
doors shall be so
described in Level Two.
08 Removal of sanitary
fittings shall be deemed
to include removing traps
and temporarily capping
03 Existing ceiling 01 Mineral fibre ceiling off pipework, or,
finishes boards including metal removing associated
suspension system traps and pipework back
to wall or floor and
terminating connections,
as the case may be.
09 For 'existing plumbing,
mechanical and electrical
02 Gypsum board ceiling installations', the removal
including metal shall be deemed to
suspension system include for the whole
building unless otherwise
stated and making good
all work disturbed.
10 Disconnecting and, if
04 Existing coverings 01 Membrane/Felt required, subsequent re-
02 Metal roofing including connection of plumbing
purlins/cladding rails and electrical or other
03 Roofing tiles including services installations is
battens and felt and deemed included.
sisalation under

39
03 DEMOLTION, ALTERATIONS, REPAIRS AND CONSERVATION
05 Existing doors, 01 Timber doors and
windows and the like frames
02 Metal doors and
frames
03 Roller shutters
04 Roller grilles
05 Timber windows and
frames
06 Metal windows and
frames
06 Existing 01 Balustrades including
balustrades, railings handrails
and handrailings
02 Railings including
handrails
03 Handrails
07 Existing fixtures and 01 Timber counters;
fittings overall (dimensional
description)
02 Timber counters;
overall (dimensional
description)
Timber cupboards;
overall (dimensional
description)
03 Timber cupboards;
overall (dimensional
description)

08 Existing sanitary 01 W.C.'s


fittings 02 Wall hung wash hand
basins
03 Countertop hand
basins
04 Sinks
05 Urinals
06 Long baths

40
03 DEMOLTION, ALTERATIONS, REPAIRS AND CONSERVATION
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
09 Existing plumbing, 01 Hot and cold-water
mechanical and plumbing installation
electrical 02 Rainwater plumbing
installations installation
03 Soil and waste
plumbing installation
04 Mechanical ventilation
installation
05 Air conditioning
installation
06 Fire protection
installation
07 Electrical installation
08 Telephone installation
09 Communication
installation
10 Lift installation
11 Escalators installation

41
03 DEMOLTION, ALTERATIONS, REPAIRS AND CONSERVATION
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
02 Cutting and forming nr 01 Door openings 01 In (thickness) thick 01 (dimensional 01 'Extending and making
02 Window openings reinforced concrete description) good plaster' shall be
wall deemed included.
02 In (thickness) thick 02 If provision of lintel over
brick/block wall the opening is required, it
shall be so described in
Level Two.
03 In (thickness) thick 03 "making good plaster
drywall and preparing surfaces
to receive new" shall be
so described in Level
Two.
nr 03 Blank openings 01 In (thickness) thick 04 The locations or levels
reinforced concrete where such works are
floors required shall be so
described in Level One.

02 In (thickness) thick 05 Details given of new


timber floors work are to be the
equivalent of those
details required by the
rules for the
measurement of the
same in other Work
Sections.
nr 04 Recesses 01 In (thickness) thick
brick/block wall

03 Cutting back nr 01 On concrete 01 (dimension description)


projections piers/walls
02 On brick piers/walls

42
03 DEMOLTION, ALTERATIONS, REPAIRS AND CONSERVATION
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
04 Cutting back to reduce nr 01 On Brick/block walls 01 (area) area of wall;
thickness cutting back by (width)

05 Filling in existing nr 01 Door openings 01 In (thickness) thick 01 (dimensional


openings reinforced concrete description)
02 Window openings wall
02 In (thickness) thick
brick/block wall

nr 03 Blank openings 01 In (thickness) thick


reinforced
concrete floors

nr 04 Recesses 01 In (thickness) thick


brick/block wall

43
03 DEMOLTION, ALTERATIONS, REPAIRS AND CONSERVATION
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED

03 Repairs/Cleaning/Renovating
and Conserving

01 Repairing m 01 Timber fascia 01 (depth) deep;


boards replacing with new
materials as
necessary

nr 02 Timber flush doors 01 replacing missing


and broken parts.
03 Timber panelled 02 Replacing loose
doors ironmongery.

nr 04 Timber casement 01 (dimensional


window; easing and description);
adjusting replacing missing
and broken parts
02 replacing loose
ironmongery.

nr 05 Timber composite 01 (dimensional


window; easing and description);
adjusting replacing missing
and broken parts
02 replacing loose
ironmongery.

m 06 Timber balustrades 01 replacing damaged


07 Chain link fencing with new materials
to match existing.

44
03 DEMOLTION, ALTERATIONS, REPAIRS AND CONSERVATION
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED
02 Repointing m 01 With cement-lime 01 on brick/block walls 01 Removal of existing joint
(1:1:6); including material and preparation of
raking out joints exposed surfaces deemed
(width) wide x included.
(depth) deep 02 on facing brick
walls
03 on natural stone
walls

03 Resin impregnation / m2 01 To concrete walls 01 (thickness) thick;


injection 02 To brick/block walls drilling holes at
04 Cement impregnation 03 To stone walls (centre) centres
/ injection 04 To concrete floor
05 To concrete roof

05 Re-dressing existing m 01 With cement-lime 01 (girth) girth


flashings and the like (1:1:6); including
raking out existing
joints

45
03 DEMOLTION, ALTERATIONS, REPAIRS AND CONSERVATION
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED
06 Damp proof course m 01 Injected chemical 01 To brickwork 01 (thickness) thick;
renewal/insertion damp proof courses drilling holes at
02 To blockwork (centre) centres

02 Injected mortar 03 To stonework 02 (thickness) thick;


damp proof courses removing
finishes and
03 Electro osmosis drilling holes at
damp proof course (centre) centres
04 Inserted mechanical
damp proof courses

07 Cleaning surfaces m2 01 Using an abrasive


approved method to
get rid of all dirt,
grease and other
contaminants to fully
expose concrete
surface

08 Renovating and m2 01 Cutting out defective 01 to a minimum depth 01 The unit of measurement
conserving; concrete concrete and of (depth) shall be left to the discretion
--- replacing with new; 02 to a minimum depth of the surveyor but shall
m bonding new to of (depth) and reflect the size and extent of
existing with (width) wide the work.
bonding agent
--- 03 to a minimum depth
nr of (depth), (width)
wide and (length)
long
--- 04 (dimensional
description)
item

46
03 DEMOLTION, ALTERATIONS, REPAIRS AND CONSERVATION
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED
09 Renovating and m2 01 Cutting out, 01 to a minimum depth
conserving; decayed, defective of (depth)
brickwork/blockwork --- and cracked work; 02 to a minimum depth
10 Renovating; m replacing with of (depth) and
engineering brickwork materials to match (width) wide
11 Renovating; facing --- existing; bonding to 03 to a minimum depth
brickwork existing with mortar of (depth), (width)
12 Renovating; natural nr wide and (length)
stonework long
--- 04 (dimensional
description)
item

47
04 EXCAVATING, FILLING AND SITEWORKS
04 EXCAVATING, FILLING AND SITEWORKS

01 Site Clearance
02 Bulk Excavations
03 Foundation Excavations
04 Filling
05 Sundries

Information to be provided in the 1. General


Specification 2. Site Clearing
3. Preservation of Existing Trees
4. Demolition of Existing Structures
5. Relocation of Existing Utilities and Services
6. General Excavation
7. Excavation for Foundations, Pits and Trenches
8. Sides of Excavation
9. Excavation to Be Kept Dry
10. Bottom of Excavation
11. Inspection
12. Backfilling
13. Anti-Termite Treatment
14. Cut and Fill to Formation Level
15. Filling under Floors, Aprons etc.
16. Temporary Drainage Channels and Bunds
17. Clearing of Existing Ditches, Rivers, etc.
18. Protection and Maintenance of Earthworks
19. Hardcore

48
04 EXCAVATING, FILLING AND SITEWORKS
Specific information to be shown 1. For site clearance, the acreage to be cleared, the extent of lifting turf for preservation ( if any), the number and
in the 2D drawings or to be input location of existing trees to be relocated (if any).
into the 3D models 2. For bulk excavation, existing levels/contours and the required formation levels and/or reduced levels; rock levels
or estimated quantity of rock (if any); the area and depth for any removal of unsuitable material from the site;
surplus excavated material to be removed to Contractor's own dumping ground or designated dumping ground.
3. For foundation excavation, total depth of excavation; rock levels or estimated quantity of rock (if any).
4. For filing, the source, and the type and the required levels.
5. For sundries, the extent and the location.

Specific rules of measurement 1. The measurement for excavation and disposal shall be those before excavation i.e. measured nett. No allowance
shall be made to any subsequent variations to bulk or any extra space required to accommodate earthwork
support, formwork and working space.
2. The measurement of filling shall be those after consolidation. All extra fill materials required due to consolidation
and penetration into the subsoil shall be deemed included.
3. Unless otherwise stated, depths of excavation are measured from the general formation levels to the bottom of the
excavations.
4. Definition of 'rock' and hard material shall be based on that defined in the 'Specification'.

Works and materials deemed 1. Bulk Excavation


included which are collectively a. Formation of slopes compacted in inclined layers and compaction to required formation level.
referred to as the 'Preambles' b. All necessary compaction testing.
c. Transporting imported earth deemed to include for all plant, machinery, labour, idling time, temporary access road
or hardstanding to area of unloading at site, obtaining all necessary approval from and payment of all royalties to
the relevant Authorities.
d. Removing earth from site deemed to include for all plant, machinery, labour, idling time, temporary access road or
hardstanding to area of unloading at site, obtaining all necessary approval from and payment of all royalties to the
relevant Authorities.
e. Excavation below the water table and in whatever soil except for rock and hard material as defined in the
Specification all multiple handling on site.

49
04 EXCAVATING, FILLING AND SITEWORKS

2. Foundation Excavation
a. Excavating in whatever type of material met with excluding rock and hard material as defined in the Specification
met with on the surface or in the excavations.
b. Getting the material out of the excavations.
c. Levelling bottoms of the excavations to falls or cambers and compacting the same.
d. Trimming sides of the excavations from vertical, battering or sloping faces.
e. Upholding and maintaining sides of the excavations by whatever means necessary including the use of bentonite
and any special shoring or sheet piling etc. as may be necessary but which do not form a permanent part of the
works to be executed, but excluding any planking and strutting to be left in or any sheet piling, etc. which form a
permanent part of the work to be executed.
f. Backfilling of selected excavated materials into the excavations and compacting the same by methods and in the
manners as specified in the Specification.
g. Multiple handling and transporting above the site.
h. Deposit, spread and level in making up levels of surplus excavated materials within the site.
i. Keeping the excavations free from storm, percolating or spring water by pumping or whatever other means
necessary.
j. Disposal of surplus excavated materials (the balance after backfilling) shall include for multiple handling of the
materials or transporting the material about the site as may be necessary prior to disposal.
k. In between and around the piles.

3. Filing, beds, blinding and the like


a. Earth, sand, quarry dust and the like material in filling, beds, blinding and the like shall include for levelling
surfaces of the same or grading surfaces of the same to falls or cambers, trimming sides of the same to form
vertical, battering or sloping surface, and any temporary retaining boards as may be required.
b. Hardcore, crusher run and the like material in filling, beds and the like shall include for hand packing the same to
form vertical, battering or sloping surface, and any temporary retaining boards as may be required.
c. Hardcore, crusher run and the like material in filling, beds and the like to receive concrete or paving shall include
for blinding for the same with sand or quarry dust, and levelling surfaces of the same or grading surfaces of the
same to falls or cambers.

50
04 EXCAVATING, FILLING AND SITEWORKS
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary

01 Site Clearance

01 Clear the entire site item 01 of trees (irrespective 01 Removing trees is deemed
within the Contract of tree girth), to include removing the
Boundary vegetation, crops, stump and roots unless
loose vegetable otherwise stated.
matter, rubbish,
debris, unwanted
materials, disused
structures, etc. and
remove from site; as
directed by S.O.
{approximate
(acreage) acres}

02 Lifting turf for m2 01 stacking on site and


preservation preserving for
replanting

03 Relocating existing nr 01 Carefully dig up 01 replant as directed by


trees existing tree as shown the S.O. on site;
in drawing (drawing including digging pit,
nr)/model; store at disposal of soil off site,
approved nursery for a backfilling with imported
duration of (nr of topsoil, fertilizer,
months) months herbicides, watering in,
stakes and other
supports as necessary.

51
04 EXCAVATING, FILLING AND SITEWORKS

ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary

02 Bulk Excavations

01 To the required m3 01 fill in and spread the


formation levels excavated materials to
area of filling
02 remove unsuitable
material from site to
contractor's own
dumping area and
backfill with imported
earth
03 remove surplus
excavated materials to
the Contractor's own
dumping area
04 fill in and spread
surplus excavated
materials to
designated dumping
area within the site

52
04 EXCAVATING, FILLING AND SITEWORKS
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
02 Extra over for m3 01 using pneumatic tools;
breaking up rock at to Authorities approval
any and by licenced
depth specialist; removing
from site
03 Extra over for 02 using chemical
breaking up hard means; to Authorities
material at any depth approval and by
licenced specialist;
removing from site
03 using control blasting;
to Authorities approval
and by licenced
specialist; removing
from site

53
04 EXCAVATING, FILLING AND SITEWORKS
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
04 To reduce levels m3 01 oversite; remove
excavated materials
to Contractor's
dumping ground:
average (depth) deep
02 oversite; remove
topsoil to be
preserved; deposit in
temporary spoil
heaps on site;
average (depth) deep

03 Foundation Excavations

01 For foundation m3 01 not exceeding 2.00m 01 If excavation is curved, it


total depth shall be so described in
02 For basement 02 not exceeding 4.00m Level One irrespective of
total depth radius.
03 For lift pits (thereafter in 2.00m 02 Foundation excavations
stages) include excavating for pad
04 For beams footings, pile caps, raft
05 For retaining wall and foundations, strip footings,
base and all other types of
foundations.
03 Commencing level shall be
so described in the
Heading.

54
04 EXCAVATING, FILLING AND SITEWORKS
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
06 Extra over for m3 01 using pneumatic tools;
breaking up rock/hard to Authorities approval
material at any depth and by licenced
for all types of specialist; removing
excavation from site
02 using chemical means;
to Authorities approval
and by licenced
specialist; removing
from site
03 using control blasting; to
Authorities approval and
by licenced specialist;
removing from site

07 Compact to the m3 01 With imported selected 01 to areas of fill


required levels material and to the
including the S.O.'s approval
formation of slopes 02 With suitable material
excavated from the
borrow pits from the
adjacent land
m3 03 With selected granular 01 to beds; (thickness)
material and to the thick {consolidated
S.O.'s approval thickness}
04 With graded granite
crusher run aggregate;
spread and levelled to
falls and cambers and
well rammed and
consolidated
05 With hardcore; spread,
levelled, well rammed
and consolidated;
watered and well rolled

55
04 EXCAVATING, FILLING AND SITEWORKS
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary

04 Filing

01 Compact to the m3 01 With imported selected 01 to areas of fill


required levels material and to the
including the S.O.'s approval
formation of slopes 02 With suitable material
excavated form the
borrow pits within
(metre/km) from the
site

m3 03 With selected granular 02 to beds; (thickness)


material to the S.O.'s thick {consolidated
approval thickness}
04 With hardcore; spread,
levelled, well rammed
and consolidated;
watered and well role;
blinded with and
including sand

56
04 EXCAVATING, FILLING AND SITEWORKS

ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary

05 Sundries

01 Anti-termite treatment item 01 anti-termite treatment to


areas underneath the
pile caps, pad footings,
ground floor, apron,
terrace and the like to
form a chemically
impregnated unbroken
barrier in (nr) stages; to
be executed by
approved specialist who
shall give (nr) years
warranty upon
completion of the works
{approximate (area)}

57
04 EXCAVATING, FILLING AND SITEWORKS
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
02 Moisture barrier m2 01 (nr) layer (thickness) 01 laid on hardcore 01 No allowance is made for
thick polythene sheet laps at joints.
moisture barrier 02 All turn-ups, turndowns,
laps, and joints deemed
included.
03 Forming holes deemed
included.
04 Narrow widths and small
quantities deemed
included.
03 Geotextile fabric m2 01 (thickness) thick; 01 horizontal
anchoring with (type) 02 sloping
03 vertical

04 Silt traps nr 01 Construct sediment 01 overall size


basin; complete with (dimensional
gabion embankment, description)
emergency spillway,
(dia.) diameter mild
steel riser perforated
pips at top filled with
anti-vortex plate and
trash rack, (dia.)
diameter Class (class)
reinforced concrete
discharge pipe;
including maintenance
throughout the contract
period and remove and
make good upon
completion; including
all accessories; as
detailed in Drawing
(drawing nr)/model

58
04 EXCAVATING, FILLING AND SITEWORKS

ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
05 Berm drains, slope item 01 construct berm drains,
embankments and slope embankments
sumps and sumps; including
all necessary
excavation, concrete
lining, formwork, fabric
reinforcement and
close turfing to sloping
surfaces; as detailed
in Drawing (drawing
nr)/model

06 Temporary earth item 01 construct temporary


drains earth drains including
the formation of slope
and remove
excavated material to
and including
spreading over an
area of fill; as detailed
in Drawing (drawing
nr)/model

59
05 GROUND REMEDIATION AND SOIL STABILISATION
05 GROUND REMEDIATION AND SOIL STABILISATION
01 Ground remediation
02 Soil stabilisation
03 Instrumentation

Information to be provided in the 1. Soil investigation report


Specification 2. Ground conditions
3. Ground water level(s) and date(s) established
4. Original and proposed ground levels
5. Any item(s) that must remain on site during the works and be protected from damage
6. Any item(s) adjacent to site that may impact on the works
7. Nature of any known non-hazardous or hazardous contamination on the site or in the ground
8. Starting level of each type of excavation
9 Preparation prior works carry out
10. Details of trial pits or boreholes including their location
11. Details of live over or underground services including their location
12. Pile sizes and their locations where applicable
13. Type of testing and compliance
14. Type of instrumentation

Specific information to be shown 1. For ground remediation, the type/s and details and locations.
in the 2D drawings or to be input 2. For soil stabilisation, the type/s and details and locations and the requirement for pull out test.
into the 3D models 3. For instrumentation, the type/s and numbers and the locations to be installed and for monitoring, the frequency of
reporting.

Specific rules of measurement 1. All measurements of area are nett and do not include for any additional area required for working space, etc.

60
05 GROUND REMEDIATION AND SOIL STABILISATION
Works and materials deemed' 1. Disposal off site of all surplus excavated materials
which are collectively referred to 2. Disposal of all surface water
as the Preambles
3. Support to faces of excavation unless not at the discretion of the contractor
4. Working space
5. Excavation and filling for temporary works unless not at the discretion of the contractor
6. Levelling, grading, trimming and compacting surfaces exposed by the excavations
7. Curved work
8. Multiple handling of excavated materials on site

61
05 GROUND REMEDIATION AND SOIL STABILISATION
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary

01 Ground remediation

01 Mobilisation item 01 allow for the provision


of necessary
equipment, plant, tools
and ancillary and for
their transportation to
the site, handling,
assembling, erecting,
dismantling, moving
within site during the
works and any idle
standing item and
demobilisation upon
completion, including
any excavation, filling
earth to make up levels
and staging required
for moving of plant
from differing levels on
site

02 Geotextile separators m2 01 supply and lay Type


(type) (weight/m2)
g/m2 non-woven
geotextile separator; all
in accordance to
Drawing (drawing
nr)/model

62
05 GROUND REMEDIATION AND SOIL STABILISATION
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
03 Vertical drains m 01 supply and install
(type) (dimensional
description) pipes
including punching
through geotextile
separator; all in
accordance with
Drawing (drawing
nr.)/model

04 Perforated subsoil m 01 supply and install


pipes (dia.) diameter
horizontal (type)
perforated subsoil
pipe wrapped with filer
fabric including all
necessary jointing as
shown in Drawing
(drawing nr)/model

63
05 GROUND REMEDIATION AND SOIL STABILISATION
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
05 Surcharge m3 01 Fill to the required 01 With imported selected 01 to surcharge area;
levels including the material and to the including removal from
formation of slopes S.O.'s approval the site upon the expiry of
02 With suitable material the surcharge period of
excavated from the (months) months
borrow pits from the
adjacent land and to
the S.O.'s approval
03 With imported common
filter sand and to the
S.O. approval

06 Dynamic compaction nr 01 using (nr) tonnes drop


hammer with (nr)
drops at height of
(height)

64
05 GROUND REMEDIATION AND SOIL STABILISATION
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary

02 Soil stabilisation

01 Mobilisation item 01 allow for the provision


of necessary
equipment, plant,
tools and ancillary and
for their transportation
to the site, handling,
assembling, erecting,
dismantling, moving
within site during the
works and any idle
standing item and
demobilisation upon
completion, including
any excavation, filling
earth to make up
levels and staging
required for moving of
plant from differing
levels on site

65
05 GROUND REMEDIATION AND SOIL STABILISATION
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
02 Soil nailing nr 01 (dia.) diameter (grade) 01 (length) long
Grade galvanised
deformed bar
complete with head
assembly and
approved centralizers
at (spacing) spacing;
including drilling hole
minimum (dia.)
diameter through
whatever material
except rock; grouting
with non-shrink grout
Grade (grade); as
shown in Drawing
(drawing nr)/model
---- ----------------------
m 02 extra-over for drilling
minimum (dia.)
diameter hole through
rock material

66
05 GROUND REMEDIATION AND SOIL STABILISATION
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
nr 02 Reinforced vibrated in-situ 01 (dimensional
concrete Grade C (grade) description)
P soil nail pad; including l
layer of BRC mesh
(gauge) and formwork; as
shown in the Drawing
(drawing nr)/model

m2 03 Supply, sprayed and cure 01 (dimensional


shotcrete facing, Grade description)
(grade) to a minimum of
(thickness) thick; including
two layers of BRC mesh
(gauge), preparing surface
to receive the same, (dia.)
diameter perforated PVC
Class (class) weep holes
complete with endcap and
geotextile filter fabric,
polyfoam, and accessories
spaced at (spacing) m c/c
including drilling holes
through whatever material;
anchored by shotcrete
Grade (grade) cast into
(dia.) diameter and
(length) long holes at
(spacing) m c/c
horizontally and vertically
throughout the facing
including all drilling
through whatever material
and (dia.) diameter
anchored bars; as shown
in the Drawing (drawing
nr)/model.

67
05 GROUND REMEDIATION AND SOIL STABILISATION

ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
nr 02 Pull out test on soil nail 01 to (nr) times the
working load of
(nr) KN

03 Ground anchors nr 01 (nr) KN working load; 01 To earth 01 (length) long


(nr) number of strands; 02 To natural hard
covered with PVC material
sheath and grease; 03 To rock
including strand holding
head, drilling, and
cement grout as shown
in Drawing (drawing
nr)/model

02 Pull out test on ground 01 to (nr) times the 01 generally


anchors working load of
(nr) KN

04 Rock bolt nr 01 (type) with (dia.) 01 (length) long


diameter; including
drilling as shown in
Drawing (drawing
nr)/model

02 Pull out test on rock bolt 01 to (nr) times the


working load of
(nr) KN

68
05 GROUND REMEDIATION AND SOIL STABILISATION
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
05 Horizontal drain nr 01 Supply and install (dia.) 01 To earth 01 (length) long
diameter horizontal 02 To natural hard
perforated drain wrapped material
with filler fabric including 03 To rock
all necessary jointing as 04 To unsuitable
shown in Drawing material
(drawing nr)/model 05 To artificial hard
material

06 Pressure nr 01 Drillings (dia.) diameter to 01 To earth 01 grouting using (nr)


grouting/ground a depth of (depth) 02 To natural hard N/mm water/cement
permeation material grout
03 To rock
04 To unsuitable
material
05 To artificial hard
material

07 Surface protection m2 01 (thickness) thick (concrete


grade) guniting
02 Rock netting with (type)
wire gauge size of
(gauge)

69
05 GROUND REMEDIATION AND SOIL STABILISATION
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary

03 Instrumentation

01 Supply and install nr


piezometer for
monitoring pore-water
pressure response

02 Supply and install nr


settlement marker for
monitoring ground
displacement

03 Supply and install nr


inclinometer for
monitoring angles of
slope and elevation

04 Monitoring and item


reporting on a weekly
basis from the date of
installation of the same
until the expiry of the
(period)

70
06 PILING WORKS
06 PILING WORKS

01 Bakau piles
02 Precast concrete piles
03 Precast concrete spun piles
04 Precast prestressed concrete piles
05 Cast-in-place bored piles
06 Contiguous bored piles
07 Micro piles
08 Interlocking steel sheet piles
09 Isolated steel piles
10 Soldier piles
11 Testing

Information to 1. General requirements applicable to all types of piling systems e.g. soil investigation reports, tolerances, piling program, records,
be provided in nuisance and damage, damage to piles, safety precautions, definition, etc.
the
Specifications
2. Specification for the following: (to group those applicable to each type of piling system)
a. General k. Code of Practice u. Marking, handling and storage of piles
b. Materials l. Equipment and plant v. Tolerances in pile dimensions
c. Stacking and storing m. Site condition w. Repair and lengthening of pile
d. Pitching and driving n. Ground condition x. Cutting and stripping of pile heads
e. Pile extension o. Site surface, etc y. Straightness of piles
f. Cut off level of piles p. Boring pile shafts z. Grout and grouting
g. Obstruction to piles driving q. Underground services aa. Reinforcement
h. Heave r. Pile shoes ab. All types of pile testing
i. Workmanship s. Supply of piles
j. Defects on piles while driving t. Production of piles at site

71
06 PILING WORKS
Specific 1. For Bakau piles, the number, the length and diameter of the piles; total penetration depth and jointing details (if any).
information 2. For Preformed piles, the diameter and pre-bored length (if any); type, number, the length and diameter/size of preformed piles; the
to be shown commencement level, total penetration depth and jointing details (if any); pile shoe (if any); the cut-off level.
in the 2D 3. For bored piles, type, number, and diameter of bored piles; the commencement level, total penetration depth and allowance for
drawings or boring through rock; type and grade of concrete and reinforcement detail; permanent casing (if required); structural steel supports
to be input whether Consultant's or Contractor's design for contiguous bored piles ( if Consultant's design, then Consultant to give details).
into the 3D
models 4. For interlocking steel sheet piles, type and mass(kg/m2) of steel piles; whether permanent or on a rental basis; area and
maximum length of sheet piles; structural steel supports whether Consultant's or Contractor's design (if Consultant's design, then
Consultant to give details.
5. For Isolated steel piles, type and x-sectional dimension and mass (kg/m); commencement level and total penetration depth and
jointing details (if any); toe and capping plates detail (if any);
6 For Soldier piles, type and x-sectional dimension and mass (kg/m); commencement level and total penetration depth and jointing
details (if any); the Group of sawn timber boarding; structural steel supports whether Consultant's design or Contractor’s design (if
Consultant's design, Consultant to give details.
7. For testing, the types, loading and nr for each type required.

Specific rules 1. For driven piles and isolated steel piles


of
measurement a. Unless otherwise stated, supply of the piles shall be the actual length of pile installed i.e. from cut-off level to shoe point
when driven.
b. Unless otherwise stated, driving of piles shall be the length of pile measured from the toe of the pile when driven to the toe
of the pile when pitched.
c. Unless otherwise stated, cut off level for piles shall be at 75mm above the bottom level of the pile cap.

2. For bored piles and micropiles


a. Unless otherwise stated, boring shall be measured from the top of founding bedrock/design founding level to platform level,
reduced level, or basement level as the case may be.
b. Unless otherwise stated, reinforced concrete in bored pile shall be measured from toe to cut off level while reinforcement
shall be the full length as shown in the Engineer's drawings.
c. Unless otherwise stated, permanent casing shall be measured as the actual depth of the casing.

72
06 PILING WORKS
Works and 1. General
materials Breaking pile head shall deem to include cutting, trimming, stripping, dressing for key, straightening and bending bars as necessary
deemed included' for pile cap connection and dispose surplus pile of varying length off site.
which are
collectively
referred to as
'Preambles'
2. For pre-formed concrete piles
a. Piling
(i) All labour and materials for complete pile installation inclusive of wastage
(ii) All necessary excavation works incidental to piling
(iii) Driving piles singly or in cluster
(iv) Re-driving of upheaved pile, if any
(v) Replacement of damaged pile and any pile which failed under tests
(vi) Filling up with approved fill materials any gap appearing between pile and ground due to displacement of ground on
completion of piling
(vii) Normal wet weather delays
(viii) Standing time for equipment and labour due to all the foregoing circumstances
(ix) Staging and platform for the installation of piles on embankments and slopes

b. Handling, transporting, pitching and driving


(i) Moving the pile frame about the site
(ii) Extra excavation, earth filling, and ramming entailed in the movement/positioning of the pile frames
(iii) Handling, transporting, pitching and driving of initial or extension piles irrespective of lengths
(iv) Shaping of one end of initial pile (if required)
(v) Preparing pile head and fitting the same with protective strap/helmet
(vi) Redriving of heaved piles
(vii) Marking the piles
(viii) Keeping and monitoring driving logs

73
06 PILING WORKS
3. For bored cast in place concrete piles
a. General
(i) Boring shall be deemed to include disposal of excavated materials off the site including the use of temporary casing, and/or the
use of stabilising agent e.g. bentonite for stabilising the pile boring and enlarged bases.
(ii) Suitable type of construction to suit dry, wet or cased depending on soil conditions shall be deemed included.
(iii) Pre-boring shall deem to include backfilling, hoisting, pitching and driving of piles.
(iv) Permanent casing deemed to include the supply, jointing of casings, driving heads and shoes where
applicable.
(v) All labour and materials for complete pile installation inclusive of wastage.
(vi) All necessary excavation works incidental to piling.
(vii) Installing, coring, boring, etc. in all soil (excluding solid rock) to the given level including all labour, equipment, plant and tools,
and disposal of excavated materials off the site to Contractor's own dump.
(viii) Empty bores shall deem to include filling empty bores with sand or other suitable material.
(ix) Providing pile shoes or formation of enlarged bases.
(x) Normal wet weather delays.
(xi) Replacement of any pile that fail under test.
(xii) Standing time for equipment and labour due to all the foregoing circumstances.
(xiii) Staging and platform for the installation of piles on embankments and slopes.

74
06 PILING WORKS

b. In-situ Concrete and reinforcement


Refer to those as stated under Work Section 09: 'In-situ concrete works'.

4. For interlocking steel sheet piles


a. Supply and install
(i) Supply and install for extra material at laps, welding along interlocks and coating with approved anti-rust paint.

b. Handling, transporting, pitching and driving


(i) Refer to the same heading for Pre-formed concrete piles above.

5. For Structural Steel Supports


Submittal all shop drawings to be endorsed by Professional Engineer registered with the Board of Engineer, Malaysia and the
method statement for the approval of the S.O./Engineer.

a. Testing
(i) Testing of piles is deemed to include for the provision of monitoring details with calculated movements to the bored piles
installed and also movements to existing structure above and below the ground.
(ii) For PDA test, is deemed to include provision and setting up the necessary equipment, plant and tool including preparing pile
heads, the provision of temporary works and staging and manpower to carry out dynamic load tests using a Pile Driving
Analyser complete with CAPWAP analysis.
(iii) For Static Load Test, it is deemed to include mobilisation and demobilisation upon completion of all necessary equipment,
kentledge, etc. preparing pile heads to the required level, and attendance of surveyors and supervision during the test.

75
06 PILING WORKS
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary

01 Bakau piles

01 Mobilisation item 01 allow for the provision


of necessary
equipment, plant, tools
and ancillary and for
their transportation to
the site, handling,
assembling, erecting,
dismantling, moving
about site during the
works and any idle
standing item and
demobilisation upon
completion, including
any excavation, filling
earth to make up
levels and staging
required for moving of
plant from differing
levels on site

76
06 PILING WORKS
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
02 Supply, transport, pitch nr 01 (dia.) diameter
and drive bakau piles average (length) long
including cutting off at each
required level

03 Supply, transport, pitch


and drive bakau piles
in two lengths including
approved mild steel
sleeve joint with
bituminous paint and
cutting off at required
level

77
06 PILING WORKS
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary

02 Precast concrete piles


03 Precast concrete spun piles
04 Precast prestressed concrete piles

01 Mobilisation item 01 allow for the provision 01 To add 'Notes' preceding


of necessary the first Heading as
equipment, plant, follows:
tools and ancillary and (a) The Contractor must
for their transportation obtain the services
to the site, handling, of a Licenced
assembling, erecting, Surveyor to carry out
dismantling, moving the setting out of all
about site during the piles position and be
works and any idle responsible to install
standing item and all piles accurately to
demobilisation upon the lines and levels
completion, including required.
any excavation, filling (b) The Contractor will
earth to make up also be responsible
levels and staging for the accurate
required for moving of setting out of the
plant from differing whole of the works
levels on site and will be required
to make good at his
expenses to the
satisfaction of the
S.O. any errors in
the positioning which
may arise from any
cause.
(c)
The Contractor shall
submit piling records
of all piles driven
including final.

78
06 PILING WORKS
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
(c) reports for all piles
duly tested signed by
the Contractor and
Engineer's or S.O.'s
representatives as
work proceeds.
(d) The Contractor shall
allow the temporary
works design to
address matters of
safety, security and
stability of the
strutting if deemed
necessary by the
Engineer.
(e) Any other
requirements.

02 Pre-bore vertical hole m 01 (dia.) diameter bored


commencing from (to length {(nr)
state the level) and nr.}
through whatever soil
strata and surplus
material disposed (to
state the place of
disposal)
03 Supply, deliver to site, m 01 (X-sectional 01 If there is pile shoe, it
handle and pitch (type dimension/diameter) shall be so described in
of pre-formed concrete initial piles (length) Level One.
piles) long
02 (X-sectional
dimension/diameter)
extension piles
(length) long

79
06 PILING WORKS

ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
04 Drive only (type of m 01 (X-sectional 01 If the piles are rake and/or
pre-formed concrete dimension/diameter) in water, it shall be so
piles) singly or in piles stated in Level One.
cluster; commencing 02 Type of piling method to
from (level) level be stated in the Heading
e.g. use of Hydraulic
hammer or Jack in
Machine.

05 Jointing with fillet weld nr 01 to (X-sectional


all round edges of mild dimension/diameter)
steel plate; including piles
two coats of epoxy
paint to exposed
surfaces of welded
plate

80
06 PILING WORKS
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
06 Break up and cut off to nr 01 (X-sectional
the required level dimension/diameter)
including cutting, piles
trimming, stripping,
dressing for key,
straightening and
bending bars as
necessary for pile cap
connection and dispose
surplus pile of varying
lengths on or off site as
directed for

07 Supply and install mild nr 01 (dia.) 01 For precast concrete


steel pile-plug with diameter spun piles only.
starter bars as basket to piles
receive and including
concrete infill Grade C
(grade) P

08 Approved mild steel pile nr 01 (X-sectional


shoe splayed pointed on dimension/diameter)
four faces comprising piles
(thickness) thick mild
steel plate secured for

81
06 PILING WORKS

ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary

05 Cast-in-place bored piles


06 Contiguous bored piles
07 Micro piles

01 Mobilisation item 01 allow for the 01 Applicable to the three


provision of types of piles.
necessary 02 To add 'Notes'
equipment, plant, preceding the Heading
tools and ancillary same as the Pre-formed
and for their Concrete Piles.
transportation to the
site, handling,
assembling,
erecting,
dismantling, moving
about site during the
works and any idle
standing item and
demobilisation upon
completion,
including any
excavation, filling
earth to make up
levels and staging
required for moving
of plant from
differing levels on
site

82
06 PILING WORKS
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
02 Boring m 01 Bore vertical hole 01 (dia.) diameter bored 01 Applicable to the three
at any depth piles {in (nr) nr} types of piles.
commencing from
(level) level and
through whatever
soil strata (except
rock as described)
02 Bore vertical hole
commencing from
(level) level and
through
bedrock/rock

03 Cast-in-place concrete m 01 Tremie concrete 01 (dia.) diameter bored


{Grade C (grade) piles {in (nr) nr}
P } including
vibrating and
working around
reinforcement in

04 Reinforcement kg 01 High tensile steel 01 (dia.) diameter as


bar reinforcement main bars
02 (dia.) diameter as
helical links

83
06 PILING WORKS
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
05 Breaking pile head nr 01 Break up and cut off 01 (dia.) diameter pile 01 Applicable to the three
to the required level. head types of piles.

06 Grouting m 01 Cement grout 01 (dia.) diameter 01 Applicable to Micropiles


{Grade C (grade)P} micropiles only.

bag 02 Cement grout 01 limestones cavities 01 Applicable to the three


{Grade C (grade)P} types of piles.

07 API pipes m 01 Supply and install 01 (dia.) diameter (OD), 01 Applicable to Micropiles
pipe N80 used API (thickness) thick in only.
pile (dia.) diameter
micropiles {(ton) ton}

08 Permanent casing m 01 Supply and install 01 (dia.) diameter 01 Applicable to cast- in-
permanent casing micropiles {(ton) ton} place bored piles only.
through limestone
cavity

84
06 PILING WORKS
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
09 Structural steel supports item 01 design, supply and 01 Applicable to
install temporary Contiguous bored piles
internal strutting for only.
contiguous bored
piles including
subsequent removal
from site and
closing of openings,
etc.

85
06 PILING WORKS
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary

08 Interlocking steel sheet piles

01 Mobilisation item 01 allow for the provision of


necessary equipment,
plant, tools and ancillary
and for their transportation
to the site, handling,
assembling, erecting,
dismantling, moving about
site during the works and
any idle standing item and
demobilisation upon
completion, including any
excavation, filling earth to
make up levels and staging
required for moving of plant
from differing levels on site
02 Supply, transport, m2 01 total driven area; maximum 01 If 'supply' is on a rental
pitch and drive (type length (length) basis, it shall be so stated
of steel)/kg/m2 at Heading.
interlocking steel
sheet piles;
02 If the piles are rake and/or
commencing from
(level) level in water, it shall be so
stated in Level Two.

03 Type of piling method to be


stated in the Heading e.g.
use of Hydraulic hammer or
Jack in Machine
04 Type of treatment, coating
or cathodic protection (if
any) shall be stated in Level
Two.

86
06 PILING WORKS
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
03 Cut-off or trim steel m 01 In varying length
sheet piles to the
required level

04 Structural steel item 01 design, supply and install


supports temporary internal strutting
including subsequent
removal from site and
closing of openings, etc.

09 Isolated steel piles

01 Mobilisation Item 01 allow for the provision of 01 To add 'Notes' preceding


necessary equipment, the Heading same as the
plant, tools and ancillary Pre-formed Concrete Piles
and for their transportation
to the site, handling,
assembling, erecting,
dismantling, moving about
site during the works and
any idle standing item and
demobilisation upon
completion, including any
excavation, filling earth to
make up levels and staging
required for moving of plant
from differing levels on site.

87
06 PILING WORKS
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
02 Supply, deliver to m 01 Universal bearing piles 01 (X-sectional 01 Type of treatment, coating
site, handle and pitch 02 Circular section piles dimension) x (mass) or cathodic protection (if
isolated steel piles kg/m any) shall be stated in
Level Two.

03 Drive only isolated m 01 Universal bearing 01 (X-sectional 01 If the piles are rake and/or
steel piles singly or in piles dimension) x (mass) in water, it shall be so
cluster; commencing kg/m described in Level Two.
from (level) level 02 Circular section piles
02 Type of piling method to
be stated in the Heading
e.g. use of Hydraulic
hammer or Jack in
Machine.

04 Form toe with and nr 01 To universal bearing 01 (X-sectional


including piles dimension) x (mass)
(dimensional 02 To circular section kg/m
description) Grade piles
(grade) plate welded
on as shown in
Drawing (drawing
nr)/model

05 Jointing of extension nr 01 To universal bearing 01 X-sectional


piles including all piles dimension) x
necessary mild steel (mass) kg/m
plates and welding; 02 To circular section
as shown in Drawing piles
(drawing nr)/model

06 Cut off tops of piles nr 01 For 01 X-sectional


and remove from the universal bearing dimension) x
site piles (mass) kg/m
02 For circular section
piles
88
06 PILING WORKS

ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
07 Capping plates 01 To universal 01 X-sectional
(dimensional bearing piles dimension) x (mass)
description) Grade kg/m
(grade) plate welded 02 To circular section
with and including (nr) piles
nr (dia.) diameter high
tensile U-bar girth
(girth) long as shown
in Drawing (drawing
nr)/model

89
06 PILING WORKS
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary

10 Soldier piles

01 Mobilisation Item 01 allow for the provision 01 To add 'Notes'


of necessary preceding the Heading
equipment, plant, as follows:
tools and ancillary and (a) The Contractor
for their transportation shall note that
to the site, handling, the soldier pile
assembling, erecting, system is a
dismantling, moving temporary work.
within site during the Its purpose is to
works and any idle act as planking
standing item and and strutting to
demobilisation upon the sides of the
completion, including basement
any excavation, filling excavation and
earth to make up will be removed
levels and staging as soon as the
required for moving of basement walls
plant from differing are constructed.
levels on site (b) Any other
requirements.

90
06 PILING WORKS
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary

02 Supply, deliver to site, m 01 For universal bearing 01 (X-sectional


handle and pitch piles dimension) x (mass)
soldier piles 02 For circular section kg/m
piles

03 Drive only soldier 01 Universal bearing 01 X-sectional 01 Type of piling method to


piles; commencing piles dimension) x (mass) be stated in the Heading
from (level) level kg/m e.g. use of Hydraulic
02 Circular section hammer or Jack in
piles Machine.
04 Jointing of extension 01 To universal 01 X-sectional
piles including all bearing piles dimension) x (mass)
necessary mild steel kg/m
plates and welding; 02 To circular section
as shown in Drawing piles
(drawing nr)

05 Cut off tops of piles 01 For universal 01 X-sectional


and remove from the bearing piles dimension) x (mass)
site kg/m
02 For circular section
piles

06 Timber boarding m2 01 Supply and install sawn 01 (dimensional


Group (group) description) boards
pressure-treated timber

07 Structural steel item 01 Design, supply and


supports install temporary
internal strutting
including subsequent
removal from site and
closing of openings,
etc.

91
06 PILING WORKS

ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
08 Removing soldier item 01 extracting piles,
piling upon removing boarding,
completion strutting and waling
from site; making good
all work disturbed

11 Testing

01 Pile dynamic analyser nr 01 working test piles of


(PDA) test (dia.) diameter/(size)
02 Static load test tested to (nr of times)
design working load
02 preliminary/ultimate
test pile of (dia.)
diameter/(size) tested
to (nr of times) design
working load

03 Pile integrity test nr 01 on (dia.)


diameter/(size) piles
04 Sonic logging test as
described

92
06 PILING WORKS
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
05 Proof coring as nr 01 Allow for proof coring 01 on (dia.)
described to a required depth diameter/(size) piles
from the pile head and
to pressure grout with
an approved material
the cored hole after
completion

06 Rock probing m 01 Allow for rock probing 01 on (dia.)


using percussion diameter/(size) piles
actuated rock drill {in (nr) nr}
boring into rock inside
a pile boring

93
07 DIAPHRAGM WALLS AND UNDERPINNING
07 DIAPHRAGM WALLS AND UNDERPINNING
01 Diaphragm Walls
02 Underpinning

Information to be provided in the 1. General requirements are applicable to all types of retaining wall and underpinning structure e.g. soil investigation reports,
Specification layout and detail drawing, limit of works, method of work, commencing level of excavation, etc.
2. Specification for the following: (to group those applicable to retaining and underpinning structure)
a. General g. Materials l. Drainage
b. Definition of retaining h. Execution m. Installation
structure
c. Dimension i. Geosynthetic quality n. Construction
d. Code of Practice assurance requirement o. Testing of fill material
e. Submittal design for j. Bedding and slope p. Tests of reinforcing
approval protection elements
f. Design criteria k. Separation and
stabilisation

Specific information to be 1. For diaphragm walls, the commencement level, the width and maximum depth; allowance for rock; type & grade of concrete for
shown in the 2D drawings or to diaphragm walls and capping beams; product name of the waterstop joints and its location at diaphragm walls; ground anchors
be input into the 3D models details (permanent or temporary) or temporary internal strutting to be designed by the Contractor.

2. For underpinning, the brief description of work and the method of underpinning; the depth and maximum width.

Specific rules of measurement 1. For diaphragm walls


a. If a top-down construction method is not adopted in the basement construction, then either temporary structural steel
supports or ground anchors (temporary or permanent) to diaphragm walls are required to be measured or itemised.
b. Specific rules of measurement' related to 'Excavating', 'In-situ Concrete', 'Reinforcement', and 'Formwork' items under
this Work Section shall be in accordance with those as stated in the appropriate Work Sections to which they
correspond.

2. For underpinning
a. In the event that the underpinning is of such an extent that it cannot easily be measured in accordance with these rules,
the works shall be measured in detail in accordance with the rules for the relevant trades required. In this case, the work
shall be described as 'In works of underpinning'.

94
07 DIAPHRAGM WALLS AND UNDERPINNING
Works and materials 1. For Diaphragm walls
deemed included' which are a. Excavation and disposal.
collectively referred to as b. Earthwork support.
'Preambles' c. Preliminary trenching.
d. All working space.
e. Disposal of ground and surface water.
f. Backfilling.
g. Surface treatments.
h. Vertical check including labour, test equipment and submission of records
i. Multiple handling of excavated materials and transporting about the site

2. For underpinning
a. Temporary support of existing structures
b. Excavation and disposal.
c. Earthwork support.
d. Preliminary trenching.
e. All working space.
f. Disposal of ground and surface water.
g. Cutting away existing foundations and footings and disposal
h. Preparing the underside of existing work.
i. Backfilling.
j. Surface treatment.
k. All new work associated with the process of underpinning.
l. All making good if specified

3 ‘Preambles' related to 'Excavating', 'In-situ Concrete', 'Reinforcement', and 'Formwork' items under this Work
Section shall be in accordance with those as stated in the appropriate Work Sections to which they correspond.

95
07 DIAPHRAGM WALLS AND UNDERPINNING
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary

01 Diaphragm walls

01 Mobilisation item 01 allow for the provision


of necessary
equipment, plant, tools
and ancillary and for
their transportation to
the site, handling,
assembling, erecting,
dismantling, moving
within the site during
the works and any idle
standing item and
demobilisation upon
completion, including
any excavation, filling
earth to make up levels
and staging required
for moving of plant
from differing levels on
site
02 Diaphragm wall 01 allows for the
records submission of records
duly signed by relevant
parties as work
proceeds.
03 Verticality check 01 allows for carrying out
vertically check to
diaphragm wall
inclusive of labour, test
equipment for the
completion of the tests
and submission of
records.

96
07 DIAPHRAGM WALLS AND UNDERPINNING
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED
04 Excavating m3 01 For diaphragm wall in 01 (width) wide; (depth)
alternate sections or maximum depth
other methods approved
by the S.O.; in whatever
soil strata; commencing
from existing ground
level; including removal
of surplus soil and filing
excavated trench with
bentonite slurry

02 Extra over for rock 01 using controlled blasting


excavation
02 using pneumatic tools

05 Concreting 01 Vibrated reinforced in-situ 01 (thickness) thick


concrete; Tremie II Grade diaphragm walls
C (grade) P; with (product
name/code)
waterproofing admixture
or other equal and
approved; including
vibrating and working
around reinforcement and
other sundry work in

02 Vibrated reinforced in-situ 01 capping beam


concrete; Grade C
(grade) P in

03 Plain in-site concrete; 01 blinding


Grade C (grade) P in

97
07 DIAPHRAGM WALLS AND UNDERPINNING
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
06 Waterstop joints m 01 (Product name/code) or 01 (width) wide horizontally;
other equal and approved in diaphragm wall
PVC waterstop;
embedded in concrete; 02 (width) wide vertically; in
including special welded, diaphragm wall
purpose-made or special
angles, intersections and
connectors {measured
net - no allowance made
for laps}

07 Mild steel bar kg 01 In diaphragm walls 01 (dia.) diameter; straight


reinforcement and bent
08 High tensile steel bar 02 In capping beams 02 (dia.) diameter; links,
reinforcement stirrups, binders and the
like
03 (dia.) diameter; curved

09 Fabric reinforcement m2 01 In diaphragm walls 01 BMC Ref. Nr. (reference


nr)

10 Formwork; sawn/class m2 01 Sides of capping beams


F1 to

98
07 DIAPHRAGM WALLS AND UNDERPINNING
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
11 Temporary internal item 01 Design, supply and 01 If the Consulting
strutting install temporary king Engineer designs such
post and internal temporary internal
strutting for diaphragm structing system, then
walls including such work is to be
provision of all measured in accordance
necessary piling with the rules of the Work
equipment to drive in Section: Structural
king post and the metalwork.
subsequent removal of
all temporary king post
and internal strutting

12 Cutting off diaphragm m 01 Cut off to the required 01 (thickness) thick


wall heads level; including diaphragm walls
cleaning off and
removal of debris from
the site and preparing
reinforcement for
capping beam

13 Ground anchors nr 01 (nr) KN working load; 01 through (width) wide 01 (length) long 01 Whether the ground
(nr) number of diaphragm walls; to anchors are permanent
strands; covered with whatever soil strata or temporary is to be
PVC sheath stated in the Heading.
and grease; including
strand holding
head, drilling, and
cement grout; as
shown in Drawing
(drawing nr)/model
14 Withdrawing ground item 01 This item is only required
anchors, removing if the ground anchors are
from the site; making temporary.
good all work
disturbed.

99
07 DIAPHRAGM WALLS AND UNDERPINNING

ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary

02 Underpinning

01 Underpinning m 01 (Brief description of 01 foundations


work); (depth) deep, 02 walls
--- maximum (width) wide; -------------------------------
(method of
underpinning)
nr 03 bases.

02 Concrete m3 01 Measured in accordance


with the rules of the
03 Formwork m2 appropriate trade or Work
Section stating that the
work is 'in underpinning'.

04 Reinforcement t

05 Brickwork or m2
blockwork

06 Tanking

100
08 CRIB WALLS, GABIONS, AND REINFORCED EARTH
08 CRIB WALLS, GABIONS, AND REINFORCED EARTH

Information to be provided in 1. General requirements e.g. soil investigation reports, tolerances, records, nuisance and damage, damage to structure,
the Specification safety precautions, definition etc.

2. Contractor Designed Crib Wall & Contractor Designed Reinforced Earth Wall
Performance Specification covering the
following:
a. Scope of f. Performance criteria
work
b. Submittals g. Delivery, storage, and
handling
c. Codes and h. Materials
standards
d. Design i. Fabrication
requirements

e. Testing Warranties

3. For gabion, the detail specification for the type of fill to baskets, specified treatment of basket fill and the specified
handling details.

Specific information to be 1. For crib wall and reinforced earth, the location, area, and height where are
shown in the 2D drawings or required.
to be input into the 3D 2. For gabions, the type and dimension (including the gauge) of gabions; the thickness and the formation of the wall
models built by gabions.

Specific rules of 1. For Contractor Designed Crib Wall (Crib Wall) & Contractor Designed Reinforced Earth Wall (R.E. Wall)
measurement a. As these are contractor designed items, they are priced as 'lump sum' items with the cost breakdown given
and in the event of any variation which does not affect the overall design, it would be evaluated based on the
unit rate derived from dividing the 'lump sum' price by the approximate area (measured on front face) given in
the Level 1 of the item description.

2. For gabions
a. Area is measured on the front face.

101
08 CRIB WALLS, GABIONS, AND REINFORCED EARTH
Works and materials deemed 1. For Contractor Designed Crib Wall (Crib Wall) & Contractor Designed Reinforced Earth Wall (R.E. Wall)
included' which are a. All ancillary and other works and expenditures whether or not separately mentioned or described in the
collectively referred to as Performance Specification or in the Bill which are indispensably necessary to carry out and bring to completion
'Preambles' of the works or which may contingently become necessary to overcome difficulties before completion.

2. For gabions
b. Gabion baskets are deemed to include assembling, tying, fixing, bracing and tying lids.
c. Filling is deemed to include compaction and overfilling of fill material.

102
08 CRIB WALLS, GABIONS, AND REINFORCED EARTH
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED

01 Crib walls, gabions, and reinforced earth

01 Contractor designed item 01 Design, 01 Breakdown cost 01 To add 'NOTES' preceding the
crib wall manufacture, first Heading as follows:
supply and install (i) Design fee a The Contractor shall
Crib wall engage a Specialist Sub-
{approximate area (ii) Investigation Contractor who has the
(area) m2}; as works expertise and experience to
shown in Drawing (iii) Excavation work design, supply and install
(drawing nr)/model to facilitate the such wall in accordance
construction of with the Performance
Crib wall Specification in the
(iv) Manufacture, Specification and the
supply and relevant drawings and to
deliver to site Crib the approval of the S.O.
wall components b The Contractor and his
(v) Piling (if any) Specialist Sub-Contractor
(vi) Erection and shall jointly be responsible
installation of Crib to ensure that such walls
Wall are in all respect adequate,
(v) Supply and install accurate, sufficient and fit
mass concrete for its purpose.
levelling pad c The Contractor shall submit
(vi) Supply, fill, all shop drawings and
spread, level, and samples as per
compact granular requirements stated in the
backfill Performance Specification
(vii) Other works to be and be endorsed by a
listed by the Professional Engineer
Contractor that registered with the Board of
are necessary to Engineer, Malaysia.
ensure
completion of the
Crib wall

103
08 CRIB WALLS, GABIONS, AND REINFORCED EARTH

ITEM OR WORK TO UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
BE MEASURED
02 Contractor item 01 Design, 01 Breakdown cost d Before pricing, the Contractor
designed manufacture, (i) Design fee is required to visit the site and
reinforced earth supply, and refer to the drawings for the
wall install extent, the location and the
reinforced earth (ii) Investigation works varying heights shown therein
wall to satisfy himself as regards to
{approximate (iii) Excavation work to facilities for transport and plant
area (area) facilitate the movement, means of access.
m2}; as shown construction of R.E. e Any other requirements (if any).
in Drawing Wall
(drawing (iv) Manufacture, supply
nr)/model and deliver to site
R.E. Wall
components
(v) Piling (if any)
(vi) Erection and
installation of R.E.
wall including
assembling, tying,
fixing, stacking and
tensioning
(v) Supply and install
mass concrete
levelling pad
(vi) Supply, fill, spread,
level, and compact
granular backfill
(vii) Other works to be
listed by the
Contractor that are
necessary to ensure
completion of the
R.E. Wall

104
08 CRIB WALLS, GABIONS, AND REINFORCED EARTH

ITEM OR WORK TO UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
BE MEASURED
03 Gabion basket m2 01 (dimensional 01 (width) wide walls 01 vertical
walls description)
rock-filled gabion 02 battering
with PVC-coated 03 curved on
wire gauge size plan
of (size); as 04 sloping
shown in 05 stepped
Drawing on face
(drawing
nr)/model

105
09 IN-SITU CONCRETE WORKS
09 IN-SITU CONCRETE
WORKS

01 In-situ concrete
02 Surface finishes to in-situ concrete
03 Formwork
04 Reinforcement
05 Designed joints in in-situ concrete
06 Accessories cast into in-situ concrete
07 In-situ sundries

Information to be provided in 1. Detailed specification of materials


the Specification 2. Classification of concrete mixes
3. Concrete compressive strength tests and compliance
4. Production of concrete
5. Construction with concrete
6. Reinforcement
7. Formwork and surface finish for the structure
8. Mass and lean concrete

Specific information to be 1. For in-situ concrete, type, strength requirement or a mix of the concrete for each structural or non-structural
shown in the 2D drawings or to member including one or more of the following requirements if required:
be input into the 3D models a. Any limitations on method, sequence of and speed of the pouring, and/or compacted or cured in a particular
way.
b. Watertight work with the use of waterproofing admixture.
c. Specially designed mix and/or a special type of cement e.g. rapid hardening cement, sulphur-resistant
cement, etc.
2. For surface finishes to in-situ concrete, the type of surface finishes to each of the concrete surfaces.
3. For formwork, no specific information as 'formwork' is NOT drawn or modelled.
4. For reinforcement, steel bars exceeding 12 metres in length.
5. For designed joints in in-situ concrete, type, brand, and details of the designed joints and location.
6. For accessories cast into in-situ concrete, type, and location.
7. For sundries, scupper drains, grouting, etc.

106
09 IN-SITU CONCRETE WORKS
Specific rules of measurement 1. For In-situ Concrete
a. Concrete volume is measured nett.
b. No allowance in volume to be made for deflection of formwork.
c. Deduction is not made for reinforcement, steel sections, cast-in accessories but voids irrespective of sizes
are to be deducted.
d. Concrete is deemed cast into formwork unless otherwise described.
e. Concrete is deemed finished as struck from basic finish formwork.
f. All top surfaces and soffits are deemed to finish horizontal unless otherwise stated.
g. All top surfaces are deemed finished tamped.
h. 'poured against faces of excavation', 'laid in bays', 'laid to falls, crossfalls, cambers and/or slopes
irrespective of a degree from horizontal', etc. are not being mentioned in the item descriptions but are
deemed to have been observed from the drawings or models and allowed for accordingly.

2. For Reinforcement
a. All mild steel and high tensile steel bar reinforcement shall be in lengths not exceeding 12 metres unless
otherwise stated.
b. No allowance has been made in the weights of steel reinforcement for tying wire, spacers, chairs, rolling
margin or the weight of weld metal and are deemed included.
c. Voids irrespective of any sizes for fabric reinforcement shall be deducted.
d. Bent fabric is deemed to include fabric that is wrapped around steel members.
e. Chairs and connectors are deemed included unless not at the discretion of the contractor.
f Fabric reinforcement shall deem to cut to size well lapped at joints and embedded and measured nett (no
allowance made for laps).

107
09 IN-SITU CONCRETE WORKS
3. For Formwork
a. No allowance in volume to be made for deflection of formwork.
b. Formwork to vertical surfaces i.e. columns, walls, etc. is to include for strutting to any height required.
c. `Left in' formwork shall mean formwork, which will form a permanent part of the Works.
d. Voids irrespective of any sizes shall be deducted.
e. No deduction shall be made for beam intersections.
f. Formwork to secondary beams shall be measured up the sides of main beams, but no deduction shall be
made from the formwork of the main beam where the secondary beam intersects it.
g. Formwork to beams that intersect with stanchion casings or columns shall be measured up to them on all
sides. No deduction shall be made from the formwork to stanchion casings or columns at these
intersections.
h. Strutting height ‘exceed 3.50m’ shall mean any height as shown in the relevant drawing above 3.50m.

Works and materials deemed 1. For In-situ Concrete


included which are collectively a. Providing preliminary trial mixes, tests on cement, aggregate, water, and mixed concrete
referred to as 'Preambles' b. Hoisting or pumping and placing in position
c. Tamping and/or vibrating to give thorough compaction
d. Working between and around reinforcement
e. Laying on any type of sub-base and for preparing and leaving surfaces to receive structural topping,
screeds, paving, rendering and the like
f. All construction joints whether Contractor or Consultant designed including temporary formwork to form
joggled joints and cleaning and preparing for subsequent pours (but water stops or other similar function
types shall be measured separately were required to be incorporated in construction joints)
g. Curing of concrete
h. Continuous pours of very large quantities
i. Forming and cutting and subsequent making good of:
(i) grooves, chases, rebates and the like;
(ii) mortices, holes and other sundry like items of concrete; and
(iii) opening in walls, floors, roof slabs and the like

108
09 IN-SITU CONCRETE WORKS
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED

01 In-situ concrete

01 Mass in-situ m3 01 In filling 01 generally 01 Limitations on method,


concrete; Grade 02 In blinding sequence of and speed of the
C(grade)P pouring, and/or compacted or
02 Vibrated reinforced 03 In foundations cured in a particular way (if any)
in-situ concrete; 04 In machine bases, plinths, is to be added to the Heading.
Grade C(grade)P casings to steel grillages
and the like 02 Watertight works with the use of
05 In footpaths, paving, road waterproofing admixture (if any)
and the like shall be so described in the
06 In slabs Heading.
07 In coffered/waffle slabs 03 Use of special designed mix
08 In steps, staircase and or/and a special type of cement
strings and the like e.g. rapid hardening cement,
09 In beams sulphur-resistant cement, etc (if
10 In transfer beams any) shall be so described in
11 In columns the Heading.
12 In walls 04 'Filling' includes to void, trench,
13 In structural toppings hollow piles and the like.
05 'Foundations' includes pad
m 14 In copings, kerbs, 01 (dimensioned footings, pile caps, raft
upstands, sills, lintels, description) foundations, strip footings,
fascias, fans, countertops 02 irregular shaped as column stumps, and the like.
and the like; including shown in Drawing
formwork and/or (drawing nr.)/model
reinforcement
15 In vehicular speed humps;
including formwork and/or
reinforcement

109
09 IN-SITU CONCRETE WORKS
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED
m 16 Extra over for forming 01 to underside apron 06 'Slabs' includes ground slabs
thickening slabs, footpaths, and beds, lift pit slabs,
paving and the like basement slabs, retaining wall
slabs, suspended floor slabs,
suspended roof slabs,
suspended landing slabs,
suspended ramp slabs,
suspended gutter slabs and
the like.
07 'Walls' includes basement
walls, retaining walls, lift pit
walls, shear walls, balustrade
walls and the like.
08 'Beams' includes ground
beams, floor beams, transfer
floor beams, ramp beams, roof
beams, landing beams,
staircase beams, arch beams
and the like.
09 'Columns' includes all types of
columns, piers, and stiffeners.
10 'Extra over for forming
thickening' shall deem to
include all necessary
excavation, sawn formwork,
sand blinding and hand
packing hardcore to slopes.

110
09 IN-SITU CONCRETE WORKS
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED

02 Surface finishes to in-situ concrete

01 Troweling smooth m2 01 to horizontal surfaces


02 Power floating 02 to sloping surfaces
03 Power floating; with 03 to vertical surfaces
(type of hardener, 04 to surfaces to fall or fall
dust proofers, and crossfall
waterproofers, 05 to surfaces forming
carborundum grains (dimension description)
or the like) anti-slip grooves at
04 Brushed finish (centre) centre

03 Formwork

01 Formwork; m2 01 Sides of foundations 01 vertical 01 The type of permanent


sawn/class F1 to 02 profile as shown in formwork and other
drawing (drawing associated works shall be so
nr.)/model described in the Heading.
02 Formwork; 02 Sides of machine bases, 02 Curved profile or sloping shall
wrot/steel/aluminium/ plinths, casings to steel be described in Level One;
plastic class F2 to grillages, and the like any particular/special profile
03 Formwork; 03 Sides of columns shall also be described by
steel/aluminium/class 04 Sides of beams referring to the drawing
F3 to nr./model in Level One.
04 Formwork; 03 Left-in/permanent' formwork (if
steel/aluminium/class any) shall be so described in
F4 to Level Two.
04 'Edges of beds' is for items
m2 05 Faces of walls 01 vertical related to 'apron slabs,
02 battered on one side footpaths, pavings, roads, and
the like' and ground floor
slabs.

111
09 IN-SITU CONCRETE WORKS
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED
m2 05 Sides of and soffits of 01 strutting not
beams exceeding
06 Sides and soffits of 3.50m
transfer beams

07 Sloping soffits of 02 strutting exceeding


staircases and strings 3.50m
08 Soffits of slabs
09 Soffits of coffered/Waffle
slabs
10 Soffits of transfer slabs

m2 11 Top surfaces 01 generally


12 Edges of beds
13 Edges of slabs
14 Edges of coffered/waffle
slabs
15 Edges of structural
toppings
16 Edges of staircases and
strings; cutting to the
profile of treads and risers
17 Edges of steps/undercut
risers

m2 18 Extra over for opening for 01 (dimensioned


doors or the like in walls description) as shown
(thickness) thick in Drawing (drawing
nr)/model
nr 19 Complex Shapes 01 (dimensioned
description) as shown
in Drawing (drawing
nr/model

112
09 IN-SITU CONCRETE WORKS
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED
05 Permanent formwork; m2 1 Soffits of slabs 01 strutting not 01 Type and ’brand’of permanent
(thickness) thick steel exceeding 3.50m formwork shall be described in
sheet (type) ; 02 strutting exceeding the ‘Heading’.
including welding to 3.50m
structural steelwork
as supports
2 Soffits of transfer slabs 02 strutting exceeding
3.50m
03 strutting exceeding
3.50m

06 Contractor Designed Item 1 Design, manufacture, 01 Breakdown cost 01 To add ‘NOTES’ preceding the
slipform system supply, and install (Contractor is ‘Heading’ as follows:
slipform, and use of the required to give a a) The Contractor is
slipform in accordance breakdown cost for responsibility to study the
with the Performance the use of slipform structural design as to whether
Specification in the which, among other it is suitable to use the slipform
Specification things, shall include and to ensure that the slipform
the supply cost o fall is in all respect adequate,
components of the accurate, sufficient and fit for
slipform e.g. hydraulic its purpose
pump components, b) The Contractor shall submit
yoke legs, walkaway all shop drawings and method
brackets, lifting jacks, statement for the slipform work
strand rods, etc, the including any change in the
installation cost, the concrete mix for the approval
usage cost, design of the S.O. before the
fee and the dismantle commencement to the works.
cost. c) Any other requirements (if
any).

113
09 IN-SITU CONCRETE WORKS
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED

04 Reinforcement

01 Mild steel bar kg 01 In foundations 01 (diameter) 01 Use of mild steel/high tensile


reinforcement diameter; straight steel bar reinforcement
02 High tensile steel bar In machine bases, plinths, and bent exceeding 12 metres length (if
reinforcement casings to steel grillages any) shall be so described in
02 and the like Level Two.

02 (diameter)
03 In footpaths, pavings, road diameter; links,
and the like stirrup, binders
and the like
04 In slabs 03 (diameter)
diameter; curved
05 In coffered/waffle slabs 04 (diameter)
diameter; helical
06 In walls 05 (diameter)
07 In beams diameter; as
chairs or stools
08 In columns 06 (diameter)
diameter; splice
connectors
sleeve and
wedges
09 In steps, staircase and 07 (diameter)
strings and the like diameter; welded
10 In structural toppings joints

114
09 IN-SITU CONCRETE WORKS
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED
03 Fabric reinforcement m2 01 In foundations 01 BMC Ref Nr
(reference nr)
02 In footpaths, pavings,
road and the like
03 In slabs
04 In coffered/waffle slabs
05 In walls
06 In steps, staircase and
strings and the like
07 In structural toppings

05 Designed joints in in-situ concrete

01 Expansion joints m 01 In slabs or beds 01 (width) wide 01 Construction joints located at


horizontally the discretion of the contractor
02 Construction joints 02 In walls 02 (width) wide are not measured.
vertically
03 In junction between slabs 02 The specific type from the
and walls manufacturer shall be so
described in the Heading.
03 Curved profile (if any) shall be
so described in Level Two.

115
09 IN-SITU CONCRETE WORKS
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED

06 Accessories cast into in-situ concrete

01 Spout pipes nr 01 Cast into concrete walls 01 (dimensioned 01 Kind of materials and if
description) painting required, the type
02 Weep pipes 02 Cast into concrete columns and number of coats shall be
03 Column guards 03 Cast into concrete slabs so described in the Heading.

07 In-situ concrete sundries

01 Forming scupper m 01 On slab 01 (dimensioned


drain description)

02 Grouting nr 01 Stanchion and grillages 02 (dimensioned 01 The mix of the grouting to be


bases description) added to the Heading.

116
10 PRESTRESS/PRECAST/COMPOSITE CONCRETE
10 PRESTRESS WORKS AND PRECAST CONCRETE

01 Prestress works
02 Precast concrete

Information to be provided in 1. Manufacture off-site


Specification 2. Storage
3. Handling and transport
4. Assembly and erection
5. Forming structural connections
6. Protection

Specific information to be 1. For prestress works, location and the various effective forces on each of the structures e.g. beams, slabs, etc. to
shown in the 2D drawings or to be prestressed.
be input into the 3D model 2. For precast concrete, the dimensions of each precast members e.g. columns, beams, slabs, walls, cladding,
staircase, sills, copings, drains, etc. and their locations; the grade of concrete and the reinforcement details for
associated works e.g. make-up strip, concrete topping, etc.

Specific rules of measurement 1. Deduction are not made for reinforcement, cast-in accessories, conduits, etc.
2. Fabric shall be measured as the area covered. No allowance has been made for laps.

117
10 PRESTRESS/PRECAST/COMPOSITE CONCRETE
Works and materials deemed 1. All precast concrete components is deemed to include:
included which are collectively a. Reinforcements and projecting reinforcements for lapping into the main structure
referred to as the 'Preambles' b. Lifting hooks
c. Moulds and casting
d. Keyed finish to external surfaces to receive tiling and fair finish to all other surfaces
e. Cast-in brackets, plates, U-bars, stainless steel bolts washers, and brackets, etc. welded or built into the main
structure
f. Holes, sleeves, rebates, notchings, sinkings, mortices and the like
g. Hoisting, placing in position, setting, bedding, jointing and pointing in cement mortar and/or grouting with non-
shrink cement and sand mortar including cutting-off lifting hooks
h. Temporary supports, ties, etc.
i. Concrete packing before fixing of precast units in position
j. Neoprene or plastic spacer tubes and applying silicone sealant to all joints
k. All making good
l. Casting in conduits, forming chases, opening, holes and the likes for Mechanical and Electrical installation.
m. Supply to include delivery transportation, protection, unloading to the site for storage

118
10 PRESTRESS/PRECAST/COMPOSITE CONCRETE
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE NOTES, COMMENTS AND
MEASURED GLOSSARY

01 Prestress works

01 Post-tensioning work item 01 Mobilisation 01 allow for the provision


of necessary
equipment, plant, tools
and ancillary and their
transportation to the
site, handling,
assembling, erecting,
dismantling, moving
about the site and up
the floors during the
works and any idle
standing time and
demobilization upon
completion

nr 02 Post-tension 01 to post-tension beam to 01 Post-tension work shall deem to


work provide an effective include tendons, duct, sheath,
force of (nr) KN over a anchor blocks, grout hose,
length of (length) and wedges, formwork for pour strip
(width) wide; all as and all necessary grouting,
shown in Drawing blockouts and making good
(drawing nr)/model works upon completion and to
02 to post-tension slab to be executed by an approved
provide an effective specialist.
force of (nr) KN over a
length of (length) and
an effective force of
(nr) KN over a width of
(width); all as shown in
Drawing (drawing
nr)/model

119
10 PRESTRESS/PRECAST/COMPOSITE CONCRETE
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE NOTES, COMMENTS AND
MEASURED GLOSSARY

02 Precast concrete

01 Precast Concrete Frame nr 01 Precast concrete 01 (dimensioned 01 If there is a corbel at the column
Structures frame description) columns; head, it should be stated in
as shown in Drawing Level Two stating the size.
(drawing nr)/model 02 Sloping beams shall be so
stated in Level Two.
02 (dimensioned
description) beams; as
shown in Drawing
(drawing nr)/model

120
10 PRESTRESS/PRECAST/COMPOSITE CONCRETE
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE NOTES, COMMENTS AND
MEASURED GLOSSARY
02 Precast Concrete m2 01 Hollow-core slabs 01 (thickness) thick 01 Sloping slabs/beams shall be so
Decking stated in Level Two.
02 Half slab

nr 03 Precast floor 01 (dimensioned


beams description)

m3 04 Vibrated 01 (thickness) thick 01 All necessary formwork is


reinforced in-situ concrete topping deemed included.
concrete; Grade
C(grade)P in
02 (width) gap and
(height) max. height
beam infill

kg 05 High tensile steel 01 in concrete topping


bar reinforcement slab
02 in make-up strip

m2 06 Fabric 01 in concrete topping


reinforcement slab
BMC (type) cut to
size well lapped at
joints and
embedded.

121
10 PRESTRESS/PRECAST/COMPOSITE CONCRETE
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE NOTES, COMMENTS AND
MEASURED GLOSSARY
03 Precast Concrete Walls, m2 01 Cladding panels 01 (thickness) thick 01 Horizontal, vertical or sloping
Partition and Panels 02 Wall units shall be so described in Level
Two.

04 Precast staircase nr 01 Straight flight 01 (dimensioned 01 'nr' means flight of stairs.


description) steps
02 U-flight 02 The nr of steps shall include the
03 L-flight middle landing slab (if any).
04 Spiral

05 Precast concrete sills, nr 01 Precast concrete 01 (dimensioned 01 Precast concrete surfaces water
lintels, copings, sills description) drain is deemed to include
channels, and channel 02 Precast concrete excavation, all moulds, finishing
slabs, drains and the lintels fair on exposed faces, hoisting,
likes 03 Precast concrete bedding and pointing in cement
cover slabs mortar (1:3), all ends, angles,
and all necessary formwork and
m 04 Precast concrete 01 overall (dimensioned reinforcement; laid to falls.
coping description)

m 05 Precast concrete 01 (dia) diameter


half round precast (internal)
concrete surface
water
drain/channel

122
11 MANSORY
11 MASONRY

01 Brick/block works
02 Glass block works
03 Natural stone rubble works
04 Sundries

Information to be provided in 1. Cement, sand, and mortar


the Specification 2. Types of bricks, blocks and glass block
3. Types of walling and stonework
4. Type of bond
5. Damp proof course
6. Bonding to other work
7. Mortar
8. Workmanship and construction

Specific information to be 1. For brick and block Walling, the type of brick/block and the thickness; finished fair and curved profile (if any)
shown in the 2D drawings or to 2. For glass block walls and natural stone rubble walls and dressings, thickness; the name of manufacturer/supplier
be input into the 3D models (if required) and curved profile (if any)
3. For all items in the Sundries, the width/thickness/diameter/length as the case may be.

Specific rules of measurement 1. Walls are measured on the centre line of the material unless otherwise stated.
2. 'Curved' means a curved profile at a radius as shown in the drawing.
3. No deduction is made for stiffeners and lintels for the measurement of wall area.
4. No allowance is made for laps for damp proof courses
5. Thicknesses stated are nominal.
6. All wall dimensions exclude applied finishes.

123
11 MANSORY

Works and materials deemed 1. For brickwork and glass block works, the following items is deemed to include:
included' which are collectively a. All rough and fair cutting
referred to as the 'Preambles' b. Oversailing and receding courses
c. Rough relieving and discharging arches
d. Wedging and pinning
e. Raking out joints for flashing, roof coverings, etc. and pointing with mortar
f. Bedding plates
g. Bedding and pointing frames
h. Parging and coring flues
i. Labour eaves filling
j. Plumbing
k. Angles
l. Forming square and rebated reveals, cut squint or birdsmouth
m. Forming, leaving or cutting chases, holes, and mortices
n. Cutting and pinning and/or building in
o. All making good
p. Sundry items of a like nature

124
11 MANSORY
2. For blockwork and natural stone rubble works, the following items is deemed to include:
a. All specially made block (or brickwork and/or in-situ concrete in lieu) or selected stone rubble
b. All rough and fair cutting
c. Oversailing and receding courses
d. Plumbing
e. Edges
f. Forming square and rebated reveals
g. Notches
h. Cutting and pinning at top
i. Cutting at ends and around openings
j. Cutting and bonding at intersections, angles, and irregular angles
k. Raking out joints for flashing, roof coverings, etc. and pointing with mortar
l. Bedding plates
m. Bedding and pointing frames
n. Parging and coring flues
o. Labour eaves filling
p. Forming, leaving or cutting notches, chases, holes, and mortices
q. Cutting and pinning and/ or building in
r. All making good
s. Sundry items of a like nature

125
11 MANSORY
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE NOTES, COMMENTS AND
MEASURED GLOSSARY

01 Brick and block works

01 Common Clay Brick m2 01 Walls 01 half brick thick 01 generally 01 To add 'NOTES' preceding the
02 Facing brick; finished 02 Walls; skin of 02 one brick thick Heading as follows:
fair on both sides and hollow walls 03 one and a half brick
pointed with a neat 03 Walls; built thick (a) Precast lintel or reinforced
recessed joint on the against other 04 brick on edge concrete lintel including all
works proceeds work (thickness) thick necessary formwork and
03 Engineering brick 04 Walls; used as reinforcement over
04 Cement and sand brick formwork doors/windows/opening
05 Solid concrete block 05 Walls; bonding to where necessary, all mild
06 Lightweight aerated other work steel bonding ties with one
core block end hooked and cast into
07 Hollow-core block concrete and the other end
08 Precast concrete vent build into brickwall and
block; finished fair on reinforced vibrated grade
both sides and pointed C25P stiffeners as shown
with a neat recessed in the relevant drawings are
joint on the works deemed included.
proceeds
09 Concrete Masonry (b) Laying of brick and block
Units (CMU) walling is deemed to
include cement mortar (1:3)
with plasticiser and for
laying of half brick/block
wall, it is deemed to include
a layer of 'exmet' at every
fourth course in addition.

(c) Any other requirements (if


any).

126
11 MANSORY
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE NOTES, COMMENTS AND
MEASURED GLOSSARY
m 06 Columns 01 overall 01 generally 02 For walls, tapering one side or
07 Attached (dimensioned two sides or curved profile shall
projection; description) be so described at Level Two.
finished fair and
pointed with a 03 For ‘columns’, whether ‘vertical’,
neat recessed ‘battered’, or ‘curved’ shall be so
joint on exposed described in Level Two.
faces
04 For ‘Attached projection’ whether
‘vertical’, ‘horizontal’, ‘raking or
‘curved’ shall be so described in
Level Two.
05 For ‘CMU’,whether CMU is of
m 08 Sills, steps, 01 overall 01 generally 'integrated or 'tongue and groove'
coping, thresholds (dimensioned type or normal type is to be
and the like description); brick- described in the Heading.
on-edge; finished 06 For 'sills, steps, coping,
fair face and thresholds and the like', 'bullnose
pointing to exposed bricks' or 'bricks with one
faces bevelled edge' and whether
horizontal, raking, curved or
weathering shall be so described
in Level Two.
.
m 09 Arches; including 01 Brick-on-edge; 01 forming arch;
centering; flat overall overall
(dimensioned (dimensioned
10 Arches; including description) description);
centering; finished fair
segmented face and
12 Arches; including 02 Brick-on-end; pointing to
centering; semi- overall exposed faces
circular (dimensioned
12 Arches; including description)
centering;
bullseye

127
11 MANSORY

ITEM OR WORK TO BE UNIT LEVEL 1 LEVEL 2 LEVEL 3 NOTES, COMMENTS AND


MEASURED GLOSSARY
m 13 Flush plain 01 (width) wide; 01 generally
bands; with horizontal
contrasting facing
bricks
14 Sunk plain bands; 02 (width) wide; raking
(length) set back
15 Projection plain 03 (width) wide;
bands; (length) curved
projection
04 (width) wide;
vertical

nr 16 Capping to piers 01 Brick on edge; 01 generally


and pilasters (dimensioned
description);
finished fair face
and pointing to
exposed faces
17 Bases to pilasters
18 Corbels
19 Key blocks

128
11 MANSORY
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE NOTES, COMMENTS AND
MEASURED GLOSSARY
10 Vibrated reinforced in- m2 01 In infill; well 01 Concrete Masonry 01 (thickness) thick 01 The 'm2' is the same area as
situ concrete; Grade compacted to Units (CMU) wall the CMU wall but not the actual
(Grade of concrete) 'quantity' required which can
only be computed by referring
11 High tensile steel bar kg 01 in infill to to the CMU detail for the infill.
reinforcement

02 Glass Block Works

01 Hollow glass block; m2 01 Walls 01 (thickness) thick 01 Curved profile or other profile
pointing both sides as shall be described in Level
works proceeds with Two.
(type of material) 02 If it is to be from a specific
manufacturer, it shall be so
described in the Heading.

03 Natural stone rubble works

01 Stone rubble work; m2 01 Walls 01 (thickness) thick 01 Curved profile shall be so


random stones from an described in Level Two.
approved source; built 02 Walls; tapering one
dry; uncoursed side;
03 Walls; tapering both
sides;

m 04 Extra over for 01 overall (dimensioned


capping; formed of description)
rough stones

129
11 MANSORY
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE NOTES, COMMENTS AND
MEASURED GLOSSARY

04 Sundries

01 Forming cavity m2 01 Cavity and building in 01 (width) wide


ends of wall ties

02 Cavity insulation m2 01 Expanded 01 (thickness) thick


polystyrene board; all
in accordance with
the manufacturer's
instructions
02 Rockwool insulation
slab; all in
accordance with the
manufacturer's
instruction

03 Damp proof courses m 01 Hessian reinforced 01 (width) wide 01 Damp proof courses are
bituminous felt deemed to include:
02 Polymer-based (a) forming laps, ends, and
bituminous felt angles
(b) pointing exposed edges
(c) bonding to damp-proof
membranes and the like
(d) cement mortar (1:3)
mortar

04 Weep and spout pipe nr 01 UPVC pipe; built into 01 (dimensioedl


bricks or block walls description)

05 Galvanised steel lintels nr 01 (dimensionaed


description)

130
12 WATERPROOFING
12 WATERPROOFING

01 Waterproofing and asphalt work

Information to be provided in the 1. Cementitious system


Specifications 2. Membrane system
3. Polythene moisture vapour barrier
4. Liquid applied roofing system
5. Guarantee/warranty

Specific information to be shown 1. The system and selected manufacturer's brief specification to each area.
in the 2D drawings or to be input 2. The extent of coverage.
into the 3D models

Specific rules of measurement 1. The area is measured flat - no allowance for upturns, skirting, etc and with no differentiation as to the size of the
2. area begin waterproofed.
All voids are deducted.
Works and materials deemed 1. Narrow widths
included' which are collectively 2. Forming arises, fair edges, butt joints, angles, ends, outlets and any other sundry items of a like nature
referred to as 'Preambles' 3. All surface preparation work and waterproofing treatment to the area around pipes, outlets, corners, ends,
angles, junctions, upturn, etc.

131
12 WATERPROOFING

ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary

01 Waterproofing and asphalt work

01 Cementitious system m2 01 (system from selected 01 Covering; to concrete 01 generally 01 Whether 'horizontal',
waterproofing base 'sloping' (irrespective of
manufacturer) or other 02 Coverings; to brickwork the degree), vertical,
equal and approved base raking or stepped shall
cementitious system be so described in Level
Two. In addition, if
curved profile, it shall
also be added in Level
Two.

02 Membrane system m2 01 (system from selected


waterproofing
manufacturer) or other
equal and approved
membrane system

03 Polythene moisture m2 01 (system from selected


vapour barrier. waterproofing
manufacturer) or other
equal and approved
polythene moisture
vapour barrier

132
12 WATERPROOFING

ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
04 Liquid applied roofing m2 01 (system from selected
system waterproofing
manufacturer) or other
equal and approved
---- liquid applied roofing -------------------------- --------------------
m system 01 Skirtings; to concrete 01 girth/height
base
02 Skirtings; to brickwork
base
03 Fascias; to brickwork
base
04 Fascias; to concrete base
05 Gutters; to concrete base
06 Channels; to concrete
base
07 Valleys of roof; to
concrete base
08 Kerbs; to concrete base

133
13 ROOFING
13 ROOFING
01 Roofing tiles
02 Metal roofing
03 Insulation
04 Flashings, gutters and the like
05 Roof-lights and special sheets

Information to be provided in 1. General - pitch and laps for each type of roof covering shall be strictly in accordance with the manufacturer's
the Specification instructions and all roof covering accessories shall be of the same material as the general covering.
2. Types of roofing tiles and their respective BS/ MS code and the requirements for laying of tiles and their accessories in
accordance with manufacturer's instructions.
3. Types of metal roofing and their respective BS/ MS code, and the detailed specification of surface finish, the
composition of the metal, the fixing requirements and the accessories, and the warranty required, all in accordance with
manufacturer's instructions.
4. Types of insulations and their respective BS/MS code and detailed specification.
Specific information to be 1. For roofing, quality, profile, type, name of the manufacturer/supplier and product series codes; timber battens/steel
shown in the 2D drawings or purlin; verge, hip capping, ridge capping, valleys and the like.
to be input into the 3D 2. For aluminium foil insulation, number of layers and whether single-sided or double-sided; for rockwool and glass fibre
models slabs, the thickness and weight per m3.
3. For flashings, gutters and the like, the type and gauge and the type of joints; diameter/girth; outlet at gutters.
Specific rules of 1. Slate or tile roofing, and roof decking shall be measured as carried out.
measurement 2. Bitumen-felt or other types of waterproofing membrane or screeds to RC roof are measured under the 'Waterproofing'
work section.
3. Sheet metal roofing and gutters shall be measured as the area of the finished surface.
4. Deduction shall be made for all voids irrespective of sizes.
5. When the word 'on' or 'fixed to’ follows by a sub-component in Level One or Level Two, it is assumed that the provision
of such sub-component is included in the building component/item unless stated otherwise.
'Works and materials deemed 1. For Roofing tiles and metal roofing
included' which are a. Laps
collectively referred to as b. All straight, skew and circular cutting at eaves, verges, top edges, abutments, valleys, hips and the like
‘Preambles' c. Holes for pipes and the like
d. Bedding, pointing, finishing with mortar fillets
2. For flashing and cappings
a. Laps, passing in the running lengths, fixing and pointing of edges and the types used either shown in the drawings
or accordance with the manufacturer’s recommendation.

134
13 ROOFING
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary

01 Roofing tiles

01 Clay roofing tiles m2 01 On and including 01 Pitch (nr) degree 01 generally 01 Quality, profile, and type
02 Concrete roofing tiles (dimensioned 02 Vertical coverings 02 complete with one shall be stated at the
03 Shingle tiles description) sawn 03 Conical as shown layer of single- Heading. Normally, the
04 Slate tiles pressure treated in Drawing sided aluminium name of the series from
Grade (grade) (drawing nr)/model foil sisalation the manufacturer shall also
timber battens at 04 Elliptical as shown be described.
(length) centres; in in Drawing
accordance with (drawing nr)/model
the manufacturer’s
instructions

02 On and including 05 Curved as shown


metal purlins; in in Drawing
accordance with (drawing nr)/model
the manufacturer’s -----------------------
instructions 03 extra over for ridge
------- tiles
m 04 extra over for hip
tiles
05 extra over for
valley tiles
06 extra over for
verge tiles

-----------------------
------- 07 extra over for
nr verge end capping
08 extra over for 3
ways presses
round apex
09 extra over for vent

135
13 ROOFING
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary

02 Metal roofing

01 Tile-effect metal decking m2 01 On and including 01 Pitch (nr) degree 01 generally 01 Quality, profile, and type
02 Profiled steel decking metal purlins with 02 Vertical coverings 02 complete with one shall be stated at the
03 Profiled aluminium alloy self-tapping screws 03 Conical as shown layer of single- Heading. Normally, the
decking and other fixing in Drawing sided aluminium name of the series from
accessories in (drawing nr)/model foil sisalation the manufacturer shall also
accordance with the 03 complete with one be described.
manufacturer's 04 Elliptical as shown layer of single-
instructions in Drawing sided aluminium
(drawing nr)/model foil sisalation and
02 On and including 05 Curved (thickness) mm
(dimensional thick glass fibre
description) sawn slab with
pressure treated galvanized
Grade (grade) chicken wire net
timber battens at
(length) centres; in
accordance with the -----------------------
manufacturer's 04 extra over for
instructions ridge cappings
------- 05 extra over for hip
m cappings
06 extra over for
valleys
07 extra over for
------- verges
nr -----------------------
08 extra over for
verge end capping
09 extra over for hip
end cappings
extra over for vent
10 cappings

136
13 ROOFING
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED

03 Insulation

01 Aluminium foil insulation m2 01 One layer of single- 01 pitch (nr) degree 01 If a curved profile, it shall be
sided; on 02 vertical coverings so described in Level Two.
timber/metal 03 conical as shown in
02 Battens drawing (drawing
One layer double- nr)/model
sided; on 04 elliptical as shown
timber/metal in drawing (drawing
battens nr)/model

02 Rockwool slabs m2 01 (thickness) thick;


13 Glass fibre slabs and (weight) kg/m3;
on and including
galvanised chicken
wire mesh

137
13 ROOFING
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED

04 Flashings, gutters and the like

01 Galvanised steel sheeting m 01 (gauge) gauge; with 01 box gutters; (girth) 01 Downpipes cast in the
02 Zincalume sheeting water-tight soldered girth; fixing with concrete columns or laid in
seams and joints; and including trench shall be so described
including painting approved in Level Two.
with (painting galvanised mild
system) to exposed steel brackets; 02 Flashing is to include
metal surfaces including extra for stepped, raking, curved, etc
stop ends and as shown in the relevant
rainwater pipe drawings.
02 outlets

half-round gutters;
(dia) diameter;
fixing with and
including approved
galvanised mild
steel
brackets; including
extra for stop ends
and rainwater pipe
outlets

138
13 ROOFING
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED
03 rainwater
downpipes; (dia.)
diameter/ (girth)
girth; fixing with
approved
galvanised mild
steel brackets;
including extra
04 bends and shoe
vent pipes with
mosquito proof wire
mesh; (dia.)
05 diameter
flashings; (girth)
06 girth
spout pipe; (dia)
mm diameter;
(length) mm long;
cast in concrete

03 Stainless steel sheeting m 01 (gauge) gauge; with


04 UPVC; (BS/MS code) water-tight soldered
seams and joints

05 Sundries nr 01 Galvanised steel 01 grating and frame;


to suit (dia) mm
diameter rainwater
outlet
02 dome shaped
grating and frame;
to suit (dia) mm
diameter rainwater
outlet

139
13 ROOFING
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED

05 Roof-lights and special sheets

01 Skylights nr 01 Extra over for 01 Pyramid shaped; 01 fixed to (type)


02 Dead roof lights extruded acrylic (dimensioned roofing
03 Opening roof lights 02 Extra over for description)
polycarbonate 02 Dome shaped;
(dimensioned
description)
03 Flat panels;
(dimensioned
description

140
14 CARPENTRY
14 CARPENTRY
01 Timber framing and prefabricated structures
02 Boarding, panelling, decking, casings, and linings
03 Proprietary Timber Roof Truss System
04 Metal accessories

Information to be provided 1. Schedule of timber grouping and usage


in the Specification 2. Schedule of timber species in accordance with strength grouping in accordance with MS 544
3. Schedule of moisture contents (M.C.) of timber for various positions in the building
4. Natural durability' classification of Peninsular Malaysia timbers for ground contact
5. Natural durability' classification of Sarawak timbers for ground contact
6. Timber grades and size tolerance
7. Treatment of timber
8. Moisture content and storage
9. Structural assemblies of timber
10. Timber joints
11. Glued laminated timber for structures
12. Products and materials
13. Carpentry works (generally)

Specific information to be 1. For timber framing, the following information on timber : (i) the specific type of timber e.g. Resak, Balau, etc. or 'Group' of
shown in the 2D drawings timber e.g. Group A, B, etc. (ii) sawn or wrot timber (iii) whether 'pressure treated' and (iv) size for each type of timber
or to be input into the 3D members e.g. rafters, purlins, wall plates, ceiling joists, etc. ; and the fixing and connection details.
models 2. For prefabricated structures, the following information on the timber and the structures, (i) the specific type of timber e.g.
Resak, Balau, etc. or 'Group' of timber e.g. Group A, B, etc, (ii) sawn or wrot timber (iii) whether 'pressure treated' (iv) size
for each type of timber members e.g. rafters, top and bottom chords, ties, struts, etc. comprised in each type of roof trusses
or portal frames and the 'reference' name given to each type of roof trusses or portal frames and its span over wall plates
and length of overhang; and the fixing and connection details.
3. For boarding, panelling, decking, casings and lining material, the types of material e.g. MBF, cement fibre sheet, SF
magnesium board. Plywood (MR bonded), etc; the usages e.g. for decking, panelling, casing, etc; and the fixing details.
4. For Proprietary Timber Roof Truss System, the type of roofing and ceiling that it supports.
5. For metal accessories, type and size, and detail.

141
14 CARPENTRY
Specific rules of 1. Length of members is the overall length with no deduction for splay cut or mitred ends.
measurement 2. Strutting is measured through the structural members being stiffened.
3. The length of a bolt is measured over the head.
4. No allowance is made for the mass of welds, bolts, nuts, washers, rivets, and protective coatings.

'Works and materials 1. Short lengths


deemed included' which are 2. Cutting, notching, boring, sinking, pelleting, fitting, rimming, mitering, halving, morticing, tenoning, dove-tailing, scarfing and
collectively referred to as wedging
‘Preambles' 3. All ends
4. Splayed edges
5. Temporary supports
6. Fixing with nails and glue
7. Sundry items of a like nature
8. For insulating board, wood wool board, etc, shall include for (i) narrow widths and small quantities (ii) Cutting and boring
holes for pipes, etc, & (iii) Setting out the ceiling as shown in the drawings with equal margins all round.
9. No allowance is made for the mass of welds, bolts, nuts, washers, rivets, and protective coatings

142
14 CARPENTRY
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary

01 Timber framing and prefabricated members

01 Timber framing m 01 Sawn 'Pressure Treated' 01 Rafters and 01 nominal 01 Specific types of timber
Group timber associated roof (dimensioned e.g. resak, Balau, etc.
02 Wrot 'Pressure Treated' timbers description) or 'Group' of timber
timber 02 Purlins e.g. Group A, B, etc.
03 Wrot Timber 03 Wall plates shall be described in
04 Roof and floor joists Level One.
05 Ceiling joist 02 Curved profile shall be
06 Beams described in Level
07 Posts or columns Two.
08 Partition and wall 03 Timber framing is
members deemed to include
09 Struts, ties and collars fixing and connecting
and the like with bolts, gang nails,
10 Kerbs, bearers and the slicing plates, gussets,
like webs, etc. on-site and
11 Herringbone strutting any type of joint e.g.
to floor joists tongued and grooved
12 Block strutting to floor joint, tongued, grooved
joists and V-jointed, rebated
13 Grounds joints, butt joints, etc.
14 Battens
15 Packing pieces 04 Prefabricated
---- ------------------------ ----------------------- structures, e.g. roof
m2 16 Battening plugged to 02 nominal trusses, portal frames,
walls and columns (dimensioned etc, is deemed to
17 Battening plugged to description) include all rafters, top
ceiling and beams members; at and bottom chord, ties,
18 Framework to eaves (width) wide struts, etc. and all
soffits centres fabricating, cutting,
19 Framework to ducts fixing and connecting
and pipe casings with bolts, gang nails,
20 Framework to false slicing plates, gussets,
beams webs, etc. off-site and
21 Framework to cornices its erection on-site
143
14 CARPENTRY
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
02 Prefabricated structures nr 01 Sawn 'Pressure 01 Roof trusses; Type 01 (type) pitch at including delivery to
Treated' timber (type) as shown in (degree) degree; site, hoisting and site
02 Wrot 'Pressure Treated' Drawing (drawing nr) / (length) span over bolting/gang nailing.
timber model wall plates; (length) If there are different
03 Wrot Timber 02 Portal frames; Type 02 overhang types of roof trusses
(type) as shown in (length) span; and portal frames, then
Drawing (drawing nr) / (height) high from separate supporting
model base to apex information at Level
Two and Level Three
shall be created for
each type.

144
14 CARPENTRY
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary

02 Boarding, panelling, decking, casings, and linings

01 Medium density fibreboard m2 01 Decking 01 To floors 01 plugged to concrete 01 Curved profile shall be
(MDF) 02 To landings 02 plugged on and so described in Level
02 Cement fibre sheet including Three.
03 SF magnesium board (dimensional
04 Plywood; MR bonded description)
05 Plywood; WBP bonded grounds; at (width)
06 Formica laminated plastic centres; plugged to
sheet concrete
02 Panelling 01 To walls and columns

03 Casing 01 To pipe casings

04 Boarding 01 To ceilings and beams


02 To soffits of staircases
03 To sloping roofs
04 To flat roofs
05 To gutter soffits and
sides
m 05 Lining 01 To treads; (width) wide
02 To risers; (width) wide
03 To fascias, verge and
barge; (width) wide
04 To eaves soffits;
(width) wide

145
14 CARPENTRY
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary

03 Proprietary Timber Roof Truss System

01 Design, fabrication, item 01 allow 01 To add 'NOTES'


deliver to site and preceding the Heading
installation of timber as follows:
roof trusses to support (a) Design, fabricate to
(the type of roofing site and furnish all
sheet/tiles), materials, tools, hoists,
('measured staging, temporary
separately') and at bracings, etc. for the
various heights up to a safe and proper
maximum of erection of fabricated
approximately (height) timber trusses which
above ground level are deemed to include
(approximate roof all rafters, top and
area) bottom chord, ties,
struts, bearers, wall
plates, packing pieces,
valley boards, timber
truss connectors,
straps, mild steel
holding down bolt,
gang nails, and other
associated items
required for the works
to the satisfaction of
the Architect/S.O. In
addition, the design,
the fee for which shall
deem included, shall
also suit the type of
ceiling to be installed at
the bottom chord; if
additional bearers, tie
beams, ceiling joist,
etc, to be added arising
146
14 CARPENTRY
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
therefrom, they are
also deemed included.
(b) Overall the design shall
be adequate, accurate
and fit for its purpose.
(c) Submission of all shop
drawings and samples
as per requirements
stated in the
Performance
Specification and to be
endorsed by
Professional Engineer
registered with the
Board of Engineer,
Malaysia.
(d) Any other requirements
(if any).

04 Metal accessories

01 Mild steel; including nr 01 Tie rod 01 (dimensioned


02 priming and painting 02 Bolts description)
Galvanised mild steel 03 Strips and clips 01 (girth length) girth and
(method of fixing)
04 Joist hangers 01 For joist (dimensioned
description)
05 Nail plates 01 Nominal (dimensioned
description) and
(method of fixing)
06 Connectors 01 (the connectors'
total thickness with description)
approved adhesive

147
15 GENERAL JOINERY

15 GENERAL JOINERY
01 Frames and finishings
02 Doors
03 Windows
04 Skylights
05 Staircases and steps
06 Balustrades, railings, and handrails
07 Proprietary operable wall system
08 Toilet cubicle system
09 Gypsum board partition
10 Furniture and fittings
11 Ironmongery
Information to be provided 1. Refer to ' Information to be provided in the Specification in 'Carpentry' where applicable.
in the Specification
2. Joinery works (generally)
3. Doors
4. Ironmongery

Specific information to be 1. For Frames and Finishings, specific type of timber e.g. Nyatoh, Resak, etc or 'Group' of timber e.g. Group A, B, etc.
shown in the 2D drawings
or to be input into the 3D 2. For Doors, specific type of timber e.g. Nyatoh, Resak, etc or 'Group' of timber e.g. Group A, B, etc for doors, door
models frames, architrave, etc; whether 'Pressured Treated'; types of doors e.g. flush door, panelled door, fire doors, etc with
full details including dimensions.

3. For Windows, specific type of timber e.g. Nyatoh, Resak, etc or 'Group' of timber e.g. Group A, B, etc for window
frames, mullion, transoms, cills, architrave, etc; types of windows e.g. casement windows, composite window, etc with
full details including dimensions

4. For Skylights, Staircases and Steps, specific type of timber e.g. Nyatoh, Resak, etc or 'Group' of timber e.g. Group A,
B, etc with full details including dimensions

For Balustrades, railings, and handrails, specific type of timber e.g. Nyatoh, Resak, etc or 'Group' of timber e.g. Group
5. A, B, etc with full details including dimensions

148
15 GENERAL JOINERY
6. For Proprietary Operable Wall System, the 'Brand' name; the number of panels; whether acoustic wall or other special
requirements

7. For toilet cubicle system, the 'Brand'; thickness and type of board; overall front length, wall depth, and wall height;
number of cubicles with doors

8. For gypsum board partition, the thickness of boards and the framing detail; finishing to the boards; if with glazing, the
thickness, and type of glass; if with insulation, the type; if a specific type is required, the 'Brand' name

9. For furniture and fittings, specific types of timber e.g. Nyatoh, Resak, etc or 'Group' of timber e.g. Group A, B, etc;
type of furniture and fitting e.g. cabinets, wardrobes, counters, shelving, etc and each of their dimensions.

10. For ironmongery, the schedule of ironmongery and the dimensioned description for each type.

Specific rules of 1. Length of members is the overall length with no deduction for splay cut or mitred ends.
measurement

'Works and materials 1. Short lengths and small quantities


deemed included' which 2. Narrow widths of boarding
are collectively referred to 3. Cutting and notching
as 'Preambles' 4. Holes
5. Fair, fitted, returned, shaped and housed ends
6. Regular and irregular mitres
7. Angles, junctions and heading joints
8. Planting on with nails or beads and the like punched in
9. Fixing with glue or other adhesive
10. Sundry items of a like nature
11. Plywood, hardboard and any other sheet materials of a like nature are to include for all necessary cutting of holes,
notches, etc.
12. Rebated, grooved, bevelled and the like frames
13. Ground or packing piece

149
15 GENERAL JOINERY
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED

01 Frames and finishing

01 Wrot and framed nr 01 Door frame sets; fixing 01 (x-sectional 01 Specific type of timber e.g.
'Pressure Treated' in position; prepare and dimensional Nyatoh, Resak, etc or 'Group'
timber apply (painting system) description) door of timber e.g. Group A, B, etc.
to all exposed timber frame to overall to be described in the
surfaces after fixing (dimensioned Heading.
description) door 02 If there are security bars in
opening; as shown the window frame sets, it
in Drawing (drawing shall be so described in Level
nr)/model One.
03 Curved profile (if any) shall be
so described in Level Two
nr 2 Window frame sets; 01 (x-section 04 Fixing in position' is to include
fixing in position; dimensional mild steel holdfast, infill,
prepare and apply description) window packing pieces, fixing
(painting system) to all frames to (overall cramps, dowels, etc.
exposed timber dimensional 05 Painting to door and window
surfaces after fixing description) window frames includes 'prepare and
opening; as shown prime' back of frames before
in Drawing (drawing fixing.
nr/model)

150
15 GENERAL JOINERY
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED
nr 03 Window frame sets; 01 to (overall
comprising (x-section dimensioned
dimensional description) window
description) of frames, opening; as shown in
(x-section dimensioned Drawing (drawing
description) of mullions, nr)/model)
(x-section dimensioned
description) transoms
and (x-section
dimensioned
description) cills; fixing
in position; prepare and
apply (painting system)
after fixing

nr 04 Fixed louvred window 01 (x-section


frame sets; fixing in dimensioned
position; prepare and description) window
apply (painting system) frames with grooves
to all exposed timber to (overall
surfaces after fixing dimensioned
description) window
opening; as shown in
Drawing (drawing
nr)/model

nr 05 Adjustable louvred 01 (x-section


window frame sets; dimensioned
fixing in position; description) window
prepare and apply opening; as shown in
(painting system) to all Drawing (drawing
exposed timber nr)/model
surfaces after fixing

151
15 GENERAL JOINERY

ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED
02 Wrot and framed m 01 Architraves; prepare 01 (x-section
'Pressure Treated and apply (painting dimensioned
timber finishing system) to all exposed description)
timber surfaces
02 Cornices; prepare and
apply (painting system)
to all exposed timber
surfaces
03 Mouldings, dado rails
and the like; prepare
and apply (painting
system) to all exposed
surfaces
04 Window boards;
prepare and apply
(painting system) to all
exposed surfaces
05 Skirtings; prepare and
apply (painting system)
to all exposed surfaces
06 Nosings and the like;
prepare and apply
(painting system) to all
exposed surfaces
07 Cappings; prepare and
apply (painting system)
to all exposed surfaces

152
15 GENERAL JOINERY
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED

02 Doors

01 Wrot and framed nr 01 Flush door ;(thickness 01 overall (dimensioned 01 Specific type of timber e.g.
'Pressure Treated' and type) plywood on description); hollow Nyatoh, Resak, etc or 'Group'
timber both sides and timber core construction of timber e.g. Group A, B, etc.
lipping all round; 02 pair overall to be described in the
complete with (dimensioned Heading.
(dimensioned description); hollow 02 Waterproof plywood, veneer
description and type of core construction; plywood, zinc sheet, and any
timber) door frame and including labour for other surface finishes to one
fixing in position; forming rebated side or both sides of the flush
prepare and apply meeting stiles door (if any) shall be so
(painting system) to all described in Level One.
exposed timber 03 If there is 'heelstones', it shall
surfaces after fixing; be so described in Level Two.
hanging; as shown in 04 If the 'door frames' does not
Drawing (drawing come with hinges, then '{butts
nr)/model measured separately}' shall
be added after 'hanging'' in
Level One.
nr 02 Panelled door; (the nr. 01 overall If there is 'architrave', its
of panels); complete (dimensioneddescrip 05 dimensional description and
with (dimensioned tion); solid core type shall be so described in
description and type of construction Level One.
timber) door frame and 02 If there is 'glazed single panel
fixing in position; pair overall 06 and the like' as part of the
prepare and apply (dimensioned door, its thickness and type of
(painting system) to all description); solid the glass and the dimensional
exposed timber core construction; description of glazing beads
surfaces after fixing; including labour for shall be so described in Level
hanging; as shown in forming rebated One.
Drawing (drawing meeting stiles If there is any moulding to the
nr)/model 07 panel, it shall be so described
in Level One.

153
15 GENERAL JOINERY

ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED
nr 03 Fire-rated door to 01 overall (dimensioned 08 If there is opening infilled with
Bomba's approval; description); (nr) wired glass with timber
covered both sides with hour rated beadings as observation
paint grade plywood 02 pair overall panel or infilled with louvres
with intumescent strips; (dimensioned covered one side with anti-
(dimensioned description); (nr) vermin wire netting, and the
description) (type) hour rated; including like to the door, they shall be
timber door frame; labour for forming so described in Level Two.
prepare and apply rebated meeting 09 If the 'door' is sliding or
(painting system) to all stiles folding on track, it shall be so
exposed timber described with the track
surfaces; including butt included in Level Two.
hinges and 10 Fixing in position' is to include
ironmongeries mild steel holdfast, infill,
packing pieces, fixing cramps,
dowels, etc.
11 Painting to door frames
includes 'prepare and prime'
back of frames before fixing.

154
15 GENERAL JOINERY
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED

03 Window

01 Wrot and framed nr 01 Casement Window; 01 overall (dimensioned 01 Specific type of timber e.g.
'Pressure Treated' complete with description) Nyatoh, Resak, etc or 'Group'
timber (dimensioned of timber e.g. Group A, B, etc.
description) (type of to be described in the
timber) window frame; Heading.
and fixing in position; 02 If there are mullion, transom,
opened in ( nr.) panels and cill within the window
infilled with (thickness) frame, each with its size shall
thick (type) glass with be described in Level One.
glazing beads; prepare
and apply ( painting
system) to all exposed
timber surfaces after
fixing; as shown in
Drawing (drawing
nr.)/model

155
15 GENERAL JOINERY
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED
nr 02 Composite window
comprising (nr.) nr. equal
panels; complete with
(dimensioned description)
(type of timber) packing
piece and (dimensioned
description) (type of
timber) window frame;
and fixing in position;
each panel infilled with
(thickness) thick (type)
glass with glazing beads;
prepare and apply
(painting system) to all
exposed timber surfaces
after fixing; as shown in
Drawing (drawing
nr.)/model
nr 03 Fixed louvre window;
complete with
(dimensioned description)
(type of timber) packing
piece and (dimensioned
description) (type of
timber) window frame with
grooves; Infilled with
(dimensioned description)
(type) glass louvres; and
fixing in position; prepare
and apply (painting
system) to all exposed
timber surfaces after
fixing; as shown in
Drawing (drawing
nr.)/model

156
15 GENERAL JOINERY
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED
nr 04 Adjustable louvre window; 01 Infilled with 01 overall
complete with (dimensioned (dimensioned
(dimensioned description) description) (type) description)
(type of timber) packing glass louvres fixed to
piece and (dimensioned and including (product
description) (type of name/code) a set of
timber) window frame; (single/dual control)
and fixing in position; galvanised steel
prepare and apply aluminium lacquered
(painting system) to all finished adjustable
exposed timber surfaces louvre frame including
after fixing fixing to window
frame and (nr) nr
jambs with (nr) clips
and (nr) operating
handle and all
necessary screws
and accessories; as
shown in Drawing
(drawing nr.)/model

157
15 GENERAL JOINERY
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED

04 Skylights
01 Wrot and framed nr 01 Skylights; complete with 01 overall 01 Specific type of timber e.g.
'Pressure Treated' (dimensioned description) (dimensioned Nyatoh, Resak, etc or 'Group'
timber (type of timber) frame; and description) of timber e.g. Group A, B, etc.
fixing in position; opened to be described in the
in ( nr.) of panels infilled Heading.
with (thickness) thick
(type) glass with glazing
beads; including all
ironmongery; prepare and
apply ( painting system) to
all exposed timber
surfaces after fixing; as
shown in Drawing
(drawing nr.)/model

158
15 GENERAL JOINERY
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED

05 Staircases and steps


01 Wrot and framed nr 01 Single flight staircases; 01 (dimensioned 01 Specific type of timber e.g.
'Pressure Treated' prepare and apply description) on plan Nyatoh, Resak, etc or 'Group'
timber (painting system) to all and (height) high of timber e.g. Group A, B, etc.
exposed timber to be described in the
surfaces after fixing; as Heading.
shown in Drawing 02 If the staircases are spiral, it
(drawing nr.)/model shall be so described in Level
02 Two straight flights One.
staircases and one 03 'Staircase' item shall deem to
intermediate landing; include, bearers, ground,
prepare and apply battens, bolts, and all other
(painting system) to all supports and fixing.
exposed timber
surfaces after fixing; as
shown in Drawing
(drawing nr.) / model

159
15 GENERAL JOINERY
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED

06 Balustrades, railings, and handrails


01 Wrot and framed nr 01 Balustrades; prepare 01 overall (dimensioned 01 Specific type of timber e.g.
'Pressure Treated' and apply (painting description) Nyatoh, Resak, etc or 'Group'
timber system); as shown in of timber e.g. Group A, B, etc.
Drawing (drawing to be described in the
nr.)/model Heading.
02 Railings; prepare and 02 Tempered glass or other
apply (painting system); types of glass/material
as shown in Drawing forming part of the
(drawing nr.)/model railing/balustrades shall be
03 Handrails; prepare and described in Level One.
apply (painting system); 03 Curved profile, moulded
as shown in Drawing cross-sectional shape,
(drawing nr.)/model circular cross-section and the
like (if any) shall be so
described in Level Two.
04 ''Balustrades', 'railing', and the
like items shall deem to
include associated handrails
and all components forming
the assembly and all
ornamental ends, ramps,
Quadrants and the like.
05 'Handrail' item shall deem to
include metal brackets or any
other fixing materials.

160
15 GENERAL JOINERY
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED

07 Proprietary Operable Wall System

01 Design, supply, nr 01 overall (dimensioned 01 The number of panels (if any) shall
fabricate, and install description) be so described in Level One.
Proprietary Operable 02 If the acoustic wall system or other
Wall System; as special requirements is required, it
shown in Drawing shall be so described in the
(drawing nr.)/model Heading.
03 To add 'Notes' preceding the
Heading comprising the following:
(a) Design, supply, install, and
commission shall be from
approved
manufacturer/supplier, and
the design shall be
adequate, accurate and fit
for its purpose.
(b) Submittal of all shop
drawings indicating the
System supplier's detailed
material and fabrication
specifications and
installation instructions
together with catalogues,
hardware, fastenings, and
other dates as required and
to relevant approval before
proceeding with the work.
(c) Submittal of a warranty (to
state the validity period) on
the materials and
workmanship in an
approved format.
(d) Any other requirements (if
any).

161
15 GENERAL JOINERY
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED

08 Toilet cubicle system


01 Toilet cubicles nr 01 Constructed of 01 overall (length) front 01 If specific 'brand' is required, it
system (thickness) thick (type) length, (depth) wall shall be so described in the
boards; as shown in depth and (height) Heading.
Drawing (drawing wall height; in (nr.) 02 ‘Toilet Cubicles System' is
nr.)/model cubicles with doors deemed to include lockset with
indicator, hinges, coat hook with
rubber bumper and all
necessary fittings all in
accordance with the
manufacturer's instructions.

162
15 GENERAL JOINERY
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED

09 Gypsum board partition

01 Full partition m2 01 Constructed of two skins of 01 painted on both 01 If there is door in the partition, it
(thickness) thick gypsum sides with shall be so described as '
board in taped and flushed (painting system) opened for door' & also to state
joint complete with g.i. 02 finished on both the type of framing for the door
framing and other sides with veneer but the door is measured under
necessary accessories; as wallpaper of Work Section 15: 'Joinery'.
shown in Drawing (drawing 'standard' colour 02 If specific 'brand' of gypsum
nr.)/model board is to be used, it shall be
so described in Level One.
02 Partially glazed m2 01 Constructed of two skins of 03 If there is any infill e.g. rockwool
partition (thickness) thick gypsum insulation, fiber glass insulation,
board in taped and flushed etc, it shall be described in Level
joint complete with g.i. One.
framing and other 04 Curved profile shall be so
necessary accessories; described in Level Two.
opened for and including 05 If veneer wallpaper is of special
(thickness) thick (type) color, it shall be so described in
glass panels with glazing Level Two.
gasket; as shown in
Drawing (drawing
nr.)/model

03 (nr.) hour Fire Rated m2 01 Constructed of two skins of


Proprietary Partition (thickness) thick (type) fire-
to Bomba's approval proof boards in taped and
flushed joint; complete with
(framing system) and other
necessary accessories; all
in accordance to
manufacturer's instruction;
as shown in Drawing
(drawing nr.)/model

163
15 GENERAL JOINERY
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED

10 Furniture and fittings


01 Wrot and framed nr 01 Cabinets 01 overall 01 Specific type of timber e.g.
'Pressure Treated' 02 Wardrobes (dimensional Nyatoh, Resak, etc or 'Group' of
timber 03 Counters description); as timber e.g. Group A, B, etc. to
04 Shelving shown in Drawing be described in the Heading.
(drawing 02 Furniture and fitting items are
nr.)/model deemed to include bearers,
grounds, battens, and all
components forming the
assembly including ironmongery,
glazing, type of surface finishing
and painting system as stated in
the drawings.

164
15 GENERAL JOINERY
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED

11 Ironmongery

01 Supply and fix nr 01 Nylon ring butt hinges 01 overall (dimensioned 01 If specific brand is required, it
02 Fix only 02 Stainless steel hinges description) shall be so described in Level
03 Cylindrical locksets One.
04 Mortice locksets 02 Fixing ironmongery is deemed to
05 Barrel bolts include the following:
06 Flush bolts (a) Fixing with screws of the
07 Cylindrical padlocks same finish as the
08 Door selectors ironmongery
09 Recessed flush pulls (b) Cutting, sinking, boring
10 Push plates and morticing as required
11 Door stops (c) Oiling, easing and
12 Set of sliding gears adjusting all moving parts
13 Master keying system (d) Taking out and refixing
for various locksets after painting where
necessary
(e) Leaving in perfect
working order
(f) Handing the keys
properly labelled to the
Architect/S.O. on
completion

165
16 STRUCTURAL METALWORK
16 STRUCTURAL METALWORK

01 Structural steelwork
02 Pressed steelwork

Information to be provided 1. The relevant Malaysian or British Standard for which each of type and grade of structural steel framework including
in the Specification bolts, washers, surface preparation, priming, etc. have to comply with
2. Clearance and tolerances
3. Connections, bolting, holes, welding
4. Handling, delivery to site and storage
5. Erection
6. Bedding and grouting
7. Testing on-site
8. Painting steelwork
9. Fire protection of structural steelwork
10. Shop drawings

Specific information to be 1. For structural steelwork (generally), the BS/MS code and grade of steel; type of surface preparation e.g. wire brush,
shown in the 2D drawings sandblasting to a required standard; type of paint and number of coats.
or to be input into the 3D 2. For unfabricated steelwork, in addition to those stated in Item 1, the types of structure and their respective structural
models steel sections with normal sizes and weight per m including the fixing and connections details.
3. For fabricated steelwork, in addition to those stated in Item 1, the types of fabricated steelwork with respective span and
height from ground to eave including size and weight per m for each structural steel sections comprised therein and the
fixing and connections details and with proper referencing for identification purposes.
4. For pressed steel, the type of steel, gauge, and type of section.
Specific rules of 1. Length of members is measured overall length with no deduction for splay cut or mitred ends.
measurement 2. In computing the weight of steelwork, no deduction is made for splay cuts, mitres, notches, holes, and slots.
3. The weight of irregularly shaped plates is computed net.

'Works and materials 1. The mass of framing includes all components.


deemed included' which 2. No allowance is made for the mass of welds, bolts, nuts, washers, rivets, and protective coatings.
are collectively referred to
as 'Preambles'

166
16 STRUCTURAL METALWORK
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED

01 Structural steelwork

01 Hot Rolled t 01 Stanchions and columns 01 H-sections 01 (dimensioned 01 The BS/MS code and grade of
Unfabricated 02 Beams and girders 02 Universal columns description) x steel, and the type of surface
Steelwork 03 Rafters 03 Universal beams (weight) kg/m preparation work e.g. wire brush,
02 Cold Formed 04 Struts 04 Castellated universal sandblasting to a required standard
Unfabricated beams and the type of paint and number of
Steelwork 05 Lip channel coats shall be stated at the
06 Angles Heading.
07 Joists 02 Curved, chambered, cranked
08 Square hollow members and the like (if any) shall
sections be so described in Level Three.
09 Rectangular hollow 03 Weight per cubic metre for mild
sections steel where it is not specified it is
10 Circular hollow assumed for the purpose of
section calculation to be 7.85 tonnes per
11 Universal structural m3.
tees 04 Fabricated steelwork e.g. portal
frames, roof trusses, girder trusses,
lattice trusses, is deemed to include
all stanchions, rafters, struts, top
chords, bottom chords, etc. making
up the trusses/frames, and all
welding, fabricating, cutting, fixing,
and shop bolting off-site or on-site
and its erection on-site including
delivery to site, hoisting, site bolting
and/or welding, etc., and all
necessary plates, cleats, brackets,
stiffeners, packing pieces, gussets,
shear connections and the like.

167
16 STRUCTURAL METALWORK
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED
03 Hot Rolled nr 01 Portal frames; Type 01 (span) overall span;
Fabricated Steelwork (reference) as shown in approximately
04 Cold Formed Drawing (drawing (height) high from
Fabricated Steelwork nr)/model ground to eaves
02 Roof trusses; Type
(reference) as shown in
Drawing (drawing
nr)/model
03 Girder trusses; Type
(reference) as shown in
Drawing (drawing
nr)/model
04 Lattice trusses; Type
(reference) as shown in
Drawing (drawing
nr)/model

05 Fittings, connections, nr 01 Plates, cleats, brackets, 01 (dimensioned


fixings, and stiffeners, packing description)
anchorages (for pieces, gussets, shear
unfabricated connectors and the like
steelwork); including 02 Anchor bolts
painting system (as 03 High strength friction
that of the grip bolts
associated 04 Hilti expanding bolts
unfabricated 05 Tie rods
steelwork) 06 Anti-sag rods

07 Wedging and grouting 01 (dimensioned


with non-shrink grout description)
stanchion bases

168
16 STRUCTURAL METALWORK
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED

02 Pressed steelwork

01 Pressed steel purlins m 01 Zincalume 01 (gauge) gauge;


and rails 02 Electro galvanised steel (type) section;
screwed with self-
tapping screws to
steel

169
17 METALWORK
17 METALWORK

01 Doors
02 Windows
03 Proprietary door frame
04 Adjustable glass louvre frame
05 Roller shutter
06 Roller grilles
07 Balustrades, railings, and handrails

Information to be provided in the 1. Mild steel and fabricated mild steel


Specification 2. Galvanizing
3. Stainless steel
4. Aluminium
5. Zincalume and zincanneal steel
6. Electro galvanized steel
7. Wrought iron
8. Roller shutters, roller grilles and the like
9. Balustrades, railings, and handrails

170
17 METALWORK
Specific information to be shown in 1. For Doors, details of doors including showing the dimensions, the type of material e.g. mild steel, galvanized
the drawings or to be input into the mild steel, aluminium, etc. with its thickness, type of door e.g. flush door, louvred door, proprietary door ( to
3D model state supplier/manufacturer's name and the type), etc. type of coating for aluminium doors e.g. natural
anodized, bronze anodized, etc. and its thickness, painting system for mild steel, and thickness and type of
glass if with glazing.
2. For Windows, details of windows including showing the dimensions, the types of material e.g. mild steel,
galvanized mild steel, aluminium, Zincalume, etc., with their thicknesses, types of window e.g. louvred window,
side hung window, composite window, etc., type of coating for aluminium windows e.g. natural anodized,
bronze anodized, etc. and its thickness, painting system for mild steel, and thickness and type of glass.
3. For Proprietary Door Frame, supplier/manufacturer's name or brand and door opening size.
4. For Adjustable Glass Louvre Frame, the type of material and whether single or dual control.
5. For Roller Shutter, the type of material e.g. galvanized mild steel, powder coated mild steel, extruded
aluminium, Zincalume steel, etc. model from supplier/manufacturer, whether lightweight, heavyweight or fire-
rated, whether manual or motor-operated, and with perforation holes or other feature.
6. For Roller Grilles, the type of material e.g. extruded aluminium, stainless steel, etc. model from
supplier/manufacturer, and whether manual or motor-operated.
7. For Balustrades, Railing, and Handrails, details including showing the height, the type of material e.g. mild
steel, galvanized mild steel, stainless steel, aluminium, etc. type of coating for aluminium e.g. natural anodized,
bronze anodized, powder-coated, etc. and its thickness, painting system or powder coat for mild steel, and if
with glass panels, the type e.g. tempered, laminated, etc. and its thickness.

Specific rules of measurement 1. Length of members is measured overall length with no deduction for splay cut or mitred ends.
2. The size given for irregular panes shall be the smallest rectangular size from which the pane can be obtained.

171
17 METALWORK
Works and materials deemed 1. General metalwork:
included' which are collectively a) Weight of weld metal and rolling margin
referred to as the 'Preambles' b) All straight, raking, bevel and splay cutting and notching
c) All shop and site drilling, holes and openings (no deduction in weight being made for same)
d) Marking, hoisting and erecting including temporary braces and supports.
e) Setting out, levelling and plumbing
2.
Gratings, ladders, stair balustrade, railings, and gates
All labour, materials, and appliances in welding.

All welded work exposed to view


3.
Filling welded smooth.

172
17 METALWORK
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED

01 Doors

01 Mild steel; (thickness) nr 01 Flush doors; 01 single-leaf; 01 If there is glazing, it shall be so


metal thickness; including complete with overall size described stating the thickness
prepare and apply (painting framing and (dimensioned and type of the glass and to
system) to all exposed (dimensioned description); as include the glazing gasket and
surfaces after fixing description and type) shown in Drawing sealant in Level One.
02 Galvanised mild steel; door frame; fixing in (drawing nr) / 02 If there is any anti-vermin wire
(thickness) metal thickness position and model netting to louvered doors, it shall
03 Powder-coated mild steel; including be so described in Level One.
(thickness) metal thickness ironmongery 02 pair; overall size, 03 If the door is 'Contractor designed
04 Stainless steel; (thickness) 02 Ribbed flush doors; (dimensioned window', it shall be so described
metal thickness complete with description); in Level One.
05 Aluminium; natural framing including labour 04 Fixing in position' is to include
anodised; (thickness) metal (dimensioned for forming mild steel holdfast, infill, fixing
thickness description and type) rebated meeting cramps, dowel, etc.
06 Aluminium; bronze door frame; fixing in stiles; as shown
anodised; (thickness) metal position and in Drawing
thickness including (drawing
07 Aluminium; powder-coated; ironmongery nr)/model
(thickness) metal thickness 03 Louvered doors;
08 Zincalume; (thickness) complete with 03 sliding; overall
metal thickness framing size
09 Electro galvanised steel; (dimensioned (dimensioned
(thickness) metal thickness description and type) description);
10 Zincanneal; (thickness) door frame and including sliding
metal thickness (dimensioned track; as shown in
11 PVC description) louvre Drawing (drawing
infills; fixing in nr)/model
position and
including
ironmongery

173
17 METALWORK
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED

02 Windows

01 Mild steel; (thickness) nr 01 Louvred windows; 01 overall size 01 If the window is 'Contractor
metal thickness; including complete with (dimensioned designed window', it shall be so
prepare and apply (painting framing; infilled with description) described in Level One.
system) to all exposed (dimensioned 02 If the windows are double-glazed,
surfaces after fixing description and type) it shall be so described in Level
02 Galvanised mild steel; glass; fixing in One including the airspace width
(thickness) metal thickness position and and the gas filling in between.
03 Powder-coated mild steel; including 03 If sub-frames are required, it shall
(thickness) metal thickness ironmongery; as be so described in Level One.
04 Stainless steel; (thickness) shown in Drawing
metal thickness (drawing nr)/model
05 Aluminium; natural
anodised; (thickness) metal 02 Side hung casement
thickness windows; complete
06 Aluminium; bronze with framing; infilled
anodised; (thickness) metal with (thickness) thick
thickness (type) glass;
07 Aluminium; powder-coated; including glazing
(thickness) metal thickness gasket and sealant;
08 Zincalume; (thickness) fixing in position and
metal thickness including
09 Electro galvanised steel; ironmongery; as
(thickness) metal thickness shown in Drawing
10 Zincanneal; (thickness) (drawing nr)/model
metal thickness

174
17 METALWORK
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED

03 Top hung casement


windows; complete
with framing; infilled
with (thickness) thick
(type) glass;
including glazing
gasket and sealant;
fixing in position and
including
ironmongery; as
shown in Drawing
(drawing nr)/model
04 Composite windows;
comprising (nr) nr top
hung casement
window/s and (nr)
fixed panels;
complete with
framing, mullion, and
transom; infilled with
(thickness) thick
(type) glass; fixing in
position and
including
ironmongery; as
shown
in Drawing (drawing
nr)/mode

175
17 METALWORK
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED

03 Proprietary door frame

01 Zincalume; (thickness) nr 01 Door frames 01 overall opening 01 Any specific manufacturer


metal thickness (dimensioned shall be stated in Level One.
02 Electro galvanised steel; description)
(thickness) metal thickness 02 The door frames is deemed
03 Zincanneal; (thickness) to include butt hinges, striker
metal thickness plate, wire ties and primer
and infilling back of the frame
with cement mortar.

176
17 METALWORK
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED

04 Adjustable glass louvre frame

01 Galvanised steel nr 01 Fixed to timber frame 01 set of single


aluminium lacquered control
finished adjustable louvre 02 set of dual control
frame

05 Roller Shutter

01 Galvanised mild steel nr 01 (model from the 01 to suit opening 01 If it is with perforation holes,
02 Mild Steel selected supplier / (dimensional colorbond steel, etc, it shall
03 Extruded aluminium manufacturer) description) be so described in the
04 BHP Zincalume steel lightweight roller Heading.
05 UV protected shutters
polycarbonate multiple 02 For 'fire rated steel', the fire-
panels 02 (model from the rated 'hour' shall be so
06 Fire-rated steel selected supplier / described in the Heading.
manufacturer)
heavyweight roller 03 For 'mild steel', if painted, the
shutters painting system shall be so
described in the Heading; if
03 (model from the powder coated, it shall be so
selected supplier / described in the Heading
manufacturer) fire- including its thickness.
rated shutters
04 Whether the roller shutter is
'manual spring operated' or
'motor operated including
motor, shutter box, push
button switch, guide rails and
all accessories' shall be so
described in Level One.

177
17 METALWORK
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED

06 Roller grilles

01 Aluminium nr 01 (model from the 01 to suit opening 01 For aluminium, type of


02 Stainless steel selected supplier / (dimensional coating e.g. natural anodized,
manufacturer) roller description) bronze anodized, powder-
grilles; coated, etc, and its thickness
is to be added in the Heading.

02 For 'stainless steel', whether


hairline finishing or other
finishing shall be so
described in Level One.

178
17 METALWORK
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED

07 Balustrades, railings, and handrails

01 Mild steel m 01 Balustrades; (height) 01 horizontal 01 For aluminium, type of


02 Galvanised mild steel high; including 02 raking coating e.g. natural anodized,
03 Stainless steel associated handrails; 03 curved bronze anodized, powder-
04 Aluminium as shown in Drawing coated, etc, and its thickness
05 Wrought iron (drawing nr)/model is to be added in the Heading.

02 Railings; (height) 02 If there is tempered glass


high; including panels or other types of
associated handrails; panels comprised in the
as shown in Drawing 'balustrades, railings or
(drawing nr)/model handrail', its type, thickness,
finishing, etc shall be so
03 Handrails described in Level One.

03 For 'mild steel', if painted, the


painting system shall be so
described in the Heading; if
powder coated, it shall be so
described in the Heading
including its thickness.

179
18 CLADDING AND COVERING

18 CLADDING AND COVERING

01 Contractor designed cladding


02 Contractor designed curtain walling
03 Perforated panels

Information to be provided in the Contractor designed cladding


Specification 1. Performance Specification' covering the following:
a. General
(i) Scope of work
(ii) Design concept
(iii) Delivery, storage, and handling
b. Design Criteria/Requirement
(i) Design wind loading
(ii) Deflection
(iii) Expansion and contraction
(iv) Flatness
(v) Acoustic treatment
(vi) Glass specification
(vii) Fire rating
c. Material Specifications and Finishes Requirements
(i) The material shall be aluminium composite panel of required thickness stating its composition,
mechanical properties, vibration and noise damping, thermal transmittance, the moment of inertia, panel
weight, finish and colour
The type of aluminium extrusions, fixing requirements, and type of weather seal
d. Fabrication and Installation
(i) Installation requirements
(ii) Care and protection
(iii) Warranties

180
18 CLADDING AND COVERING
Contractor designed curtain walling
1. Performance Specification' covering the following:

(i) Scope of work


(ii) Submittals
(iii) Codes and standards
(iv) Design requirements
(v) Testing
(vi) Performance criteria
(vii) Delivery, storage, and handling
(viii) Materials
(ix) Fabrication
(x) Types of glass and glazing material and their installation
(xi) Warranties
(xii) Fire rating

2 Perforated panels
(i) Thickness of metal
(ii) Type, spacing, pattern of perforations
(iii) Margin
(iv) Flatness of sheets and plates
(v) Fitting details

Specific information to be shown in 1. For cladding work, the brand name, the type of finishing and the type of system; dimension of fin and sunshade
the 2D drawings or to be input into (if any).
the 3D model
2. For curtain walling, the type of system, and type and thickness of the glazing.

3. For perforated panel, the type and thickness of the panel.

Specific rules of measurement 1. As cladding/walling is a contractor designed work, the items related thereto are either measured nett area or
net length with no allowance made for boundary work i.e. work associated with closing off or finishing off
claddings or covering at the external perimeter and at the abutment with different materials and opening work
i.e. work associated with closing off or finishing off claddings and coverings at the perimeter of an opening or a
void; in addition, these items would mean to be inclusive of all ancillary and other works and expenditure

181
18 CLADDING AND COVERING
whether or not separately mentioned or described in the Specification or in the Bill which are indispensably
necessary to carry out and bring to completion of the cladding/walling works or which may contingently become
necessary to overcome difficulties before completion.

Works and materials deemed 1. Aluminium composite panel' is deemed to include all aluminium runner sub-frames, non-magnetic stainless-
included' which are to be collectively steel fasteners, santoprene/EDPM gasket fixing anchors, aluminium brackets, stainless steel mandrel blind
referred to as 'Preambles' rivets, weather seal sealant, and all necessary accessories.

2. Aluminium fins is deemed to include galvanised mild steel bracketing, silicone sealant, and bracket rod infill.

Aluminium sunshade' is deemed to include fixing screws, bolts, nuts, and other accessories.
3.

4. Aluminium curtain walling' is deemed to include fixed and openable top hung panels formed by transoms,
mullion, and fins, steel support structures, glazing material, neoprene/EPDM glazing gasket, structural sealant,
and 2-hrs fire stop rockwool insulation, aluminium bend sheet capping and flashing, flame barrier, brackets,
bolts & nuts, weep holes, lockset and all other necessary accessories and cleaning upon completion.

5. Perforated panel' is deemed to include the support system, all necessary channel, angle bars, fixing anchors,
fixing brackets, metal screws, bolts and nuts, support plates and other accessories and painting systems
related thereto.

182
18 CLADDING AND COVERING
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED

01 Contractor designed cladding

01 Design fee item 01 allow 01 To add 'Notes' preceding the first


Heading as follows:
02 Aluminium composite m2 01 (product name/code) or 01 cladding to (a) Design, supply and install
panel other equal and plastered wall; as the cladding/walling shall be
approved in (type) finish; shown in the in accordance with the
complete with (type) Drawing (drawing Performance Specification
system; all in strict nr) / model in the Specification and the
accordance with the relevant drawings and to
manufacturer's 02 cladding to the relevant approval.
instruction concrete wall; as
shown in the (b) The design shall be in all
Drawing (drawing respect adequate, accurate,
nr) / model sufficient and fit for its
purpose.
03 Aluminium fins m 01 (product name/code) or 01 vertical; overall
other equal and (dimensioned (c) Submittal of all shop
approved in (type) finish; description) drawings and sample as per
all in strict accordance requirements stated in the
with the manufacturer's 02 horizontal; overall Performance Specification
instruction (dimensioned and to be endorsed by
description) Professional Engineer
04 Aluminium sunshade m 01 (product name/code) or 01 (width) wide registered with the Board of
other equal and Engineer, Malaysia.
approved in (type) finish;
complete with (type) (d) All laboratory testing by an
profile extrusion; all in accredited laboratory.
strict accordance with the
manufacturer's (e) Any other requirements.
instruction

183
18 CLADDING AND COVERING
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED

02 Contractor designed curtain walling

01 Design fee item 01 allow 01 To add 'Notes' preceding the first


Heading as follows:
(a) Design, supply and install
the cladding/walling shall be
in accordance with the
Performance Specification
02 Aluminium curtain walling m2 01 Unitised system in 01 glazing with in the Specification and the
(type) finish; all in (thickness) thick relevant drawings and to
strict accordance (type) glass; as the relevant approval
with the shown in Drawing (b) The design shall be in all
manufacturer's (drawing nr) / respect adequate, accurate,
instruction model sufficient and fit for its
purpose.
02 Stick system in (type) (c) Submittal of all shop
finish; all in strict drawings and samples as
accordance with the per requirements stated in
manufacturer's the Performance
instruction Specification and to be
endorsed by Professional
Engineer registered with the
Board of Engineer,
Malaysia.
(d) All laboratory testing by an
accredited laboratory
(e) Any other requirements (if
any).

02 Curved profile shall be so


described in Level Two.

184
18 CLADDING AND COVERING
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED

03 Perforated panel

01 Aluminium perforated m2 01 (thickness) thick in 01 cladding to 01 Curved profile shall be so


panel approved pattern; as plastered wall described in Level Two.
02 Powder coated perforated shown in Drawing 02 cladding to
metal panel (drawing nr) / model concrete wall
03 Expanded metal lathing 03 cladding to
panel opening

185
19 FLOOR, WALL AND CEILING FINISHES

19 FLOOR, WALL AND CEILING


FINISHINGS

01 Finishes to floors
02 Raised access floors
03 Finishes to walls and ceilings
04 Suspended ceilings
05 Accessories

Information to be provided in the 1. General specification and requirements of the components of the finishing.
Specification 2. Types of plaster work and their respective composition, mix and application.
3. Types of paving work and their respective composition, mix and application.
4. Types of tiling work and their respective compliance with MS and application.
5. Types of ceiling work and their respective specification including compliance with MS and the specification of
the suspension systems.
6. Types of granite and marble slabs and their respective source of supply, method of fixing, types of impregnators
used, requirement for dry-lay, etc.

Specific information to be shown 1. For paving, total thickness and surface treatment e.g. wood trowelled, steel trowelled, power-floated or the use
in the 2D drawings or to be input of hardener, dust proofers, carborundum grains or the like ; laid 'level' , 'falls' or 'falls and crossfalls' ; curved
into the 3D models profile ,anti-slip grooves and the like , and the use of waterproofing admixture (if required);
2. For flooring and tiles, the types, the sizes , names of the manufacturers /suppliers and the product series codes
and total thickness; use of waterproofing admixture (if required); laid in pattern or in more than one colour or
with underlay or required sanding and floor dressing, coved or nosing tiles or others (if required); curved profile
(in any);
3. Raised access floor - the type of panels, height, panels with service outlet boxes and fire barrier (if any); for
proprietary system, the name of manufacturer/supplier and the type in addition to the aforesaid.
4. For plaster/skim coat, the types and thickness; curved profile, forming grooves, sloping and the like (if any)
5. For suspended ceiling, the type, the size and thickness of panels; product name and series code of the
panels/board (if required) & type of suspension system; light troughs, bulkhead, access panels, arches, domes
and the like and precast plaster cornices and mouldings (if any).
6. For accessories, type and dimension; location.

186
19 FLOOR, WALL AND CEILING FINISHES
Specific rules of measurement 1. Area is measured net in contact with base.
2. Widths or thicknesses stated are the width or thickness of each finished face.
No measurement allowance is to be made in net area for laps, dressings or any other labour.
3. No deduction from the areas of finishing is made for grounds.
4. Width' is to be also meant the 'extreme' width where applicable.
5. High or Height is meant from the structural floor level to soffit of finish ceiling or isolated beam.

Works and materials deemed 1. For 'Finishes to floors' & 'Finishes to walls and ceilings'
included' which are collectively a. Narrow widths and small quantities.
referred to as 'Preambles' b. Temporary rules, temporary screeds, temporary supports and template.
c. Cleaning, raking out joints, hacking, slurrying and wetting the base to form a key.
d. All notching and holes.
e. Straight, raking and curved cutting.
f. Working or fitting up to and making good around frames, light fittings, grilles, air bricks, sanitary fittings,
switches, sockets, pipes, brackets and the like.
g. Joints between different types of finishes.
h. Joints between new and old finishes.
i. Dubbing out to achieve the nominal thickness stated.
j. Groin point and other intersections of curved surfaces.
k. In respect of linear items: Short lengths, formed, cut or purpose-made angles, junctions and ends.
l. In respect of in-situ finishings: internal angles, arises, rounded edges, quirks, throats, rounded coves and
external angles of any radius.
m. In respect of mosaic: setting one row of tesserae at an angle of 45 degrees at junctions of horizontal and
vertical surfaces.
n. In respect of carpeting: sewn and taped seams in carpets and underlays; matching patterns in patterned
carpets; stair rods, carpet clips and the like; ends, angles and intersections; square cutting, raking cutting,
curved cutting, notches, rounded corners, cutting around profiles of steps and the like.

187
19 FLOOR, WALL AND CEILING FINISHES
o. In respect of granite and marble slabs to walls and ceilings: metal anchorages and all necessary fixing
accessories; application of impregnator to all sides except the exposed surfaces.
p. Masking of adjacent work.
q. All other sundry items of a like nature.

2. For Raised access floors


a. If there are fire barriers, it would be deemed
to include all support work, scribing or forming to fit, angles, ends and working around structures, support
b. work and services.
Design is deemed to base on Design Criteria/ Performance Specification as per the Specification and is fit
for its purpose including the requirements for the submission of shop drawings, samples of all materials,
c. relevant details, etc. for approval of the Architect/S.O. before commencement of physical work.
The system is deemed to include the pedestal panels, grid system support and all necessary fixing
accessories.

3. For Suspended ceilings


a. Cutting or leaving openings for light fittings, air-conditioning grilles, etc. are payable separately only where
special members and extra hangers are required to support the fittings, grilles, etc. In all other cases, they
are deemed to be included in the rates for general ceilings.
b. Cutting of tiles or panels.
c. Forming small perforation in tiles or panels.
d. Suspension system including edge framings and hangers.
e. Narrow widths and small quantities.
f. Trimming around isolated columns, unless special members are required.

4. For Accessories
a. fixing ties,
b. temporary means of support.

188
19 FLOOR, WALL AND CEILING FINISHES
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED

01 Finishes to floors

01 Cement pavings m2 01 To concrete base 01 level; (thickness) 01 Watertight work with the use
02 Granolithic pavings thick of waterproofing admixture (if
any) shall be so described in
02 falls or falls and the Heading.
crossfalls;
average 02 Nature of surface treatment
(thickness) thick e.g. wood troweled, steel
troweled, power-floated or the
use of hardener, dust
proofers, carborundum grains
or the like shall be so
described in Level One.

03 Curved profile, forming anti-


slip grooves, etc. (if any) shall
be so described in Level Two.

m 02 To concrete base of 01 (dimensioned 04 Wood trowelled or steel


narrow-width description) trowelled or the like shall be
structures so described in Level One.

05 Curved profile (if any) shall be


so described in Level Two.

06 Narrow-width structures
include skirtings, risers,
treads, edges of slabs, wall
string to stairs, open strings,
kerbs, scupper drains and the
like.

189
19 FLOOR, WALL AND CEILING FINISHES
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED
03 Carpet tiles flooring m2 01 To troweled smooth 01 on level floor 01 generally 01 The sizes, the names of the
04 Machine turfed carpet screeded bed; 02 on floor: falls or manufacturers/suppliers, and
flooring (thickness) total falls and the product series code, if
05 Laminated strip flooring thickness with crossfalls; required, shall be so
06 Engineered timber flooring approved adhesive average described in the Heading.
07 Bamboo flooring 02 To troweled smooth (thickness) thick
08 Vinyl flooring surface; (thickness) 02 Watertight work with the use
09 Parquet flooring thick with approved of waterproofing admixture (if
adhesive any) shall be so described in
Level One.

---- --------------- --------------- 03 If any finishes were to lay in a


m 03 On concrete base 01 (dimensioned pattern or more than one
of narrow-width description) colour or with underlay or
structures required sanding and floor
dressing, they are to be so
described in Level One.

04 'total thickness' are the


10 Ceramic tiles m2 01 To screeded bed 01 on level floor 01 generally thickness inclusive of
11 Polished porcelain tiles (thickness) total 02 on floor: falls or finishes, the screed
12 Homogenous tiles thickness; with falls and adhesives, backing mortar,
13 Terrazzo tiles mortar; pointed with crossfalls;
keys, grooves and the like.
14 Glass mosaic tiles matching colour average
inclusive of (thickness) thick
05 ‘Narrow-width structures'
adhesives etc.
include skirtings, risers,
treads, edges of slabs, wall
02 To troweled smooth string to stairs, open strings,
screeded bed; (total kerbs, scupper drains and the
thickness) with like.
approved adhesive;
pointed with 06 Curved profile shall be so
matching colour
described in Level Three.

190
19 FLOOR, WALL AND CEILING FINISHES
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED
---- --------------- --------------- 07 For 'flooring', if 'underlay' is
m 03 On concrete base 01 (dimensioned required, it shall be so
of narrow-width description) described in the Heading.
structures
04 Extra over for
coved tiles 08 For 'flooring' if 'sanding and/or
Extra over for floor dressing is required, it
05
nosing tiles shall be so described in Level
One

15 Marble tiles/slabs m2 01 To trowelled smooth 01 on level floor 01 generally


16 Granite tiles/slabs screeded bed; 02 on floor: falls or
(thickness) total falls and
thickness with crossfalls;
approved adhesive; average
pointed with (thickness) thick
approved
cementitious grout;
grinding with an
approved machine;
coating with a coat of
approved masonry
water repellent
impregnator after
grinding; all in
accordance to the
specialist's
recommendation and
S.O.'s approval

191
19 FLOOR, WALL AND CEILING FINISHES
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED
---- --------------- ---------------
m 03 On concrete base 01 (dimensioned
of narrow-width description)
structures
---- ---------------
m 04 Extra over for
coved tiles

05 Extra over for


nosing tiles

192
19 FLOOR, WALL AND CEILING FINISHES
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED

02 Raised access floors

01 Contractor Designed m2 01 (dimensioned 01 to concrete 01 If any fire barriers within void


Raised Floor System description) (type base;(height) high below the raised floor, it shall
---- and finish) panel; --------------- be so described in Level One.
nr 02 extra-over for
panels with 02 If a proprietary system is
proprietary used, the type of system and
service outlet its manufacturer's name shall
boxes be added in the Heading.

193
19 FLOOR, WALL AND CEILING FINISHES
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED

03 Finishes to walls and ceilings

01 Plain plaster m2 01 To walls and 01 (thickness) thick 01 Wood trowelled or steel


02 Granolithic plaster columns trowelled or the like and the
03 Shanghai plaster use of plasticiser for 'Plain
04 Textured finish plaster 02 To ceilings and 01 (thickness) thick; plaster' shall be so
05 Lath plaster beams not exceeding described in the Heading.
06 Barium plaster 3.50m high
07 Skim coat 03 To soffits of 02 Curved profile, forming
staircases 02 (thickness) thick; grooves, sloping, and the
exceeding 3.50m like (if any) shall be so
high described in Level One.

03 'narrow-width structures'
---- --------------- -------------- include sills. capping, coves,
m 04 To narrow-width 01 (thickness) thick cornices, fascias,
structures and (girth) girth architraves, mouldings and
the like

194
19 FLOOR, WALL AND CEILING FINISHES
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED
08 Ceramic tiles m2 01 To screeded bed 01 To walls and columns 01 generally
09 Polished porcelain tiles (thickness) total
10 Homogenous tiles thickness; with
11 Terrazzo tiles mortar; pointed with
12 Glass mosaic tiles matching colour

02 To trowelled smooth
screeded bed;
(thickness) total
thickness with
approved adhesive;
pointed with
matching colour
---- -------------- ---------------
m 02 To narrow-width 01 (dimensioned
structures description)

195
19 FLOOR, WALL AND CEILING FINISHES
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
13 Marble tiles/slabs m2 01 To a metal support 01 To walls and columns 01 generally
14 Granite tiles/slabs system; (thickness) total
thickness; pointed with
approved sealants
coating with a coat of
approved masonry water
repellent impregnator

02 To screeded bed
(thickness) total
thickness; with mortar;
pointed with approved
sealants coating with a
coat of approved masonry
water repellent
impregnator

03 To trowelled smooth
screeded bed; (thickness)
total thickness with
approved adhesive;
pointed with approved
sealants coating with a
coat of approved masonry
water repellent
impregnator

---- --------------- ---------------


m 02 To narrow-width 01 (dimensioned
structures description)

196
19 FLOOR, WALL AND CEILING FINISHES
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
04 Suspended ceilings

01 Zinc-coated and m2 01 (dimensioned 01 On aluminium grid 01 ceilings; not 01 The product name and/or
aluminium/zinc-coated description) suspension system; all exceeding 3.50m series code, if required,
steel panels/board; in accordance with the high shall be so described in
02 Linear strip ceiling manufacturer's the Heading.
03 Plasterboard instruction 02 ceilings exceeding
04 Mineral Fibre boards 3.50m high 02 Whether 'exposed' or
05 Fibre cement ceiling 02 On hot-dipped 'concealed'
panels galvanized support suspension/support
06 Glass fibre reinforced system; all in system shall be so
gypsum (GRG) accordance with the described in Level Two.
manufacturer's
instruction 03 Curved profile, sloping
and the like shall be so
03 On timber framing; as described in Level Three.
shown in the drawing ---------------
---- (drawing nr.)/model 03 extra over for light
nr troughs; state the
size

04 extra over for


bulkheads; state
the size

05 extra over for


access panels;
state the size

extra over for


06 arches, domes
and the like; state
the size state the
size
197
19 FLOOR, WALL AND CEILING FINISHES
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary

05 Accessories

01 Metal lathing m 01 To walls and 01 (width/girth length) 01 The product name and
02 PVC corner strips columns width/girth series code (if any) shall
be so described in the
Heading.

03 Aluminium dividing m 01 Setting in beds 01 (dimensioned


strips description)
04 Brass dividing strips
Movement joints

198
20 GLAZING
20 GLAZING

01 Glazing
02 Contractor designed glass system

Information to be provided in the 1. Glass


Specification 2. Sealants
3. Glazing
4. Glazing to Timber Windows
5. Glazing to Metal Windows
Glazing to Louvred Windows
6.
Glazing to Patented Windows, Doors, Panels, Sky Lights, etc.
7.
Fixing of Glass Blocks
8. Cleaning on completion
9.
Specific information to be 1. For glazing, type and thickness of glass and the area where the glazing work is needed other than at the windows,
shown in the drawings or to be doors and other components.
input into the 3D model 2. For contractor designed frameless glass, the type and thickness of the glass and the area where such glazing work
is needed and other components which form part thereof e.g. doors.

Specific rules of measurement 1. Glazing supplied as part of a window, door or other component is measured elsewhere with those components.
2. Measurement of irregular shape glazing shall be based on the smallest rectangular area from which it can be
3. obtained.

Works and materials deemed 1. All raking and curved cutting.


included' which are collectively 2. All polished and bevelled edges unless given in the description.
referred to as 'Preambles' 3. Aligning patterned and wired glass.
4. Drilling holes and the like in the glass.
5. Cleaning off protective wax or tape coating in rebates prior to glazing windows, screens and door.
6. Gasket and glazing compounds recommended by glass manufacturers.
7. Additional costs involved in using sheets, which are larger than the manufacturer's standard stock sizes.
8. Cleaning off protective wax or tape coating in rebates prior to glazing windows, screens and doors.

199
20 GLAZING
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED

01 Glazing

01 Float glass; (thickness) m2 01 To wood with wood 01 generally 01 'clear', 'tinted', 'bronze-tinted',
thick beads 'sandblasted surface one
02 Figured glass; (thickness) side', 'acid embossed surface
thick 02 To metal with metal one side', etc, shall be so
03 Georgian wired glass; beads described in the Heading.
(thickness) thick
04 Tempered glass; 03 To double glazing; 02 Whether with 'glazing
(thickness) thick hermetically sealed; compound', 'neoprene
05 Laminated glass; infilled (thickness) gaskets', etc, shall be so
(thickness) thick airspace with gas described in Level One.
06 Tempered laminated glass;
(thickness) thick 03 Glass blocks are measured in
07 Acrylic panel; (thickness) accordance with the rules of
thick Work Section: Masonry.
08 Polycarbonate panel;
(thickness) thick 04 'Irregular in shape' other than
square or rectangular shall be
so described in Level One.

---- --------------- ---------------


nr 04 Louvre blades; to a 01 (dimensioned
slotted metal frame description)

05 Louvre blades; to a
slotted wooden frame

200
20 GLAZING
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED

02 Contractor designed glass system

01 Design fee Item 01 allow 01 To add 'Notes' preceding the first


Heading as follows:
(a) The design shall be in all
02 The contractor designed nr 01 Contractor designed 01 (thickness) thick respect adequate, accurate,
frameless glass shopfront frameless glass (type) glass; sufficient and fit for its
assemblies; as overall size purpose.
shown in Drawing (length) long x (b) Design, supply and
(drawing nr) (height) high installation of the glass
system shall be in
02 extra over for accordance with the
(type) doors; Performance Specification in
(dimensioned the Specification and the
description); relevant drawings and to the
including (type & relevant approval.
brand) floor
springs, (type) (c) Submittal of all shop
patch fittings, drawings and sample as per
(height) high requirements stated in the
(type) pull Performance Specification
handles and other and to be endorsed by
necessary Professional Engineer
ironmongery registered with the Board of
Engineer, Malaysia.

(d) All laboratory testing by an


accredited laboratory.

(e) Any other requirements (if


any).

201
20 GLAZING
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED
02 The 'assemblies' is deemed to
include the glass fins and
stiffeners, suspension and fixing
accessories, stabilisers, silicon
sealants, gaskets, bedding strips,
all jointing and glazing
accessories and all other work
necessary to complete the
installation.
03
Curved profile (if any) shall be so
described in Level Two.

202
21 DECORATION
21 DECORATION

01 Painting to all types of surfaces


02 Decorative papers or fabrics

Information to be provided in the 1. General


Specification 2. Painting to Timberwork
3. Painting to Metalwork
4. Painting to Masonry Works
5. Treatment to Fair Surfaces
6. Painting to Timber-Base Products
7. Painting to Gypsum Board and the like
8. Painting to Laboratory Bench Tops
9. Varnishing
10. Completion of Painting Work

Specific information to be 1. For painting, the painting system to each type of surfaces from a selected manufacturer.
shown in the drawings or to be 2. For decorative papers or fabric, 'product name' for the type of decorative papers or fabric from a selected
input into the 3D model manufacturer to each area.

Specific rules of measurement 1. The area or girth measured are that covered.
2. The girth of frames and the like is calculated from one edge to the other overall trims, architraves, stops and the like
3. and assume.
4. Painting to all types of doors and windows is measured flat on both sides.

Works and materials deemed 1. All cutting to the line


included' which are collectively 2. Multi-coloured work on differing surfaces
referred to as the 'Preambles' 3. All cutting to papers and fabric
4. Use of different colours to walls, ceiling, rubbing down, knotting, filing, stopping and the like
5. Rubbing down between coats
6. In respect of pipes and gutters, painting all tracks, wall hooks, holderbats, brackets, ears and the like
7. In respect of external paintwork, additional scaffolding and staging

203
21 DECORATION
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED

01 Painting to all types of surfaces

01 Prepare and apply m2 01 One coat of (product 01 Plastered walls 01 generally 01 'Narrow width structures'
name/code) wall and columns include sills, cappings, coves,
sealer and two coats cornices, fascias, architraves,
of (product 02 Skim-coated wall mouldings, skirting, dado
name/code) emulsion rails, bands, balustrades,
paint from 03 Fair face concrete railings, handrails, door
(manufacturer's vent block wall frames, edge of slabs, kerbs
name) or other equal and the like
and approved. 04 Gypsum board 02
wall If painting is by 'spraying
02 Two coats of method', it shall be so
(product name/code) 05 Cellulose fibre described in Level One.
emulsion paint from cement board
(manufacturer's wall
name) or other equal
and approved.

204
21 DECORATION
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED
06 Plastered ceilings 02 not exceeding
and beams 3.50m high
above finished
07 Gypsum floor level
plasterboard
ceilings
08 03 exceeding
Mineral fibre board 3.50m high
ceilings above finished
09 floor level
Cellulose fibre
cement board
ceilings

----- ---------------
m ---------------
m 10 Narrow-width 04 (dimensioned
structures description)

----- --------------- ---------------


m 11 Plastered open 05 (width) wide
stringer of the {extreme}
staircase including
working to the
profile of tread
and undercut
riser

205
21 DECORATION
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED
02 Prepare and apply m2 01 One coat of 01 Flush doors 01 generally
(product 02 Glazed doors
name/code) primer, 03 Louvred doors
one coat of (product 04 Panelled doors
name) undercoat 05 Glazed casement
and two coats of windows
(product name)
enamel paint from 06 Composite
(manufacturer's casement
name) or other windows
equal and approved
07 Skylights
02 (nr) coats of
(product
name/code) varnish
from
(manufacturer's
name) or other
equal and approved

03 (nr) coats of
(product
name/code) stain
and (nr) coats of
(product
name/code) lacquer
from
(manufacturer's
name) or other
equal and approved

------ -------------- ---------------


m 08 Narrow width 02 (girth) girth
structures

206
21 DECORATION

ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED
03 Prepare and apply m2 One coat of (product 01 Metal doors 01 generally
name/code) primer, one 02 Mild steel grille
coat of (product doors
name/code) undercoat 03 Mild steel louvred
and two coats of doors
(product name/code) 04 Glazed metal
enamel paint from casement
(manufacturer's name) windows
or other equal and 05 Composite metal
approved casement
windows
06 Metal skylights

---- --------------- ---------------


m 07 Narrow width 02 (dimensioned
structures description/girth)

m2 One coat of (product 01 Gutters 01 girth not 01 'Small pipe' shall mean any
name/code) primer, one 02 Flashings exceeding pipe which is equal to or less
coat of (product 03 Small pipes 300mm than 100mm diameter while
name/code) undercoat 04 Large pipes 'large pipe' for pipe more
and two coats of 02 girth exceeding than 100mm diameter.
(product name/code) 300mm
enamel paint from
(manufacturer's name)
or other equal and
approved

207
21 DECORATION
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED
kg One coat of (product 01 structural
name/code) primer, two steelwork
coats of (product
name/code) enamel
paint from
(manufacturer's name)
or other equal and
approved

02 Decorative papers or fabrics

02 Preparing, sizing and m2 01 (product name/code) 01 Walls and 01 generally 01 Wall and columns' and
hanging with approved (type) decorative columns 'Ceilings and beams' can be
adhesive paper from of any type of surfaces e.g.
(manufacturer's 02 Ceilings and plastered surfaces, gypsum
name) or other equal beams board surfaces, steel
and approved surfaces, etc.
---- --------------- ---------------
m 03 Narrow width 02 (dimensioned
structures description/girth)

208
22 DRAINAGE AND PIPING WORKS BELOW GROUND

22 DRAINAGE AND PIPING WORKS BELOW GROUND

01 Surface water drainage


02 External sewerage reticulation
03 External water reticulation
Information to be provided 1. Surface Water Drainage
in the Specification a. Excavation
b. Surface Water Drains
c. Culverts
d. Box Culvert
e. Backfilling of Trench

2. External Sewerage Reticulation


a. Scope of Works t. Change in line and grade am. Reinstatement of surfaces other than
roads
b. Definitions u. Trial Holes an. Appurtenant structure in the pipeline
c. Specialists, Inspection and v. Reinstatement of trial holes ao. Fill adjacent to structures
Testing
d. Tools w. Trench excavation in roads ap. Surface drains
e. Handling and storage of x. Trench excavation in surfaces aq. Existing services
pipes other than roads
f. Inspection at time of y. Supporting Trench ar. Fences and walls
installation Excavations
g. Installation of pipes z. Battered trench sides as. Crossing watercourses
h. Pipe laying aa. Inspection by Engineer at. Clean up
i. Closures and short sections ab. Disposing material from trench au. Materials for sewers
excavation
j. Cleanliness of pipelines ac. Trenches not to be left open av. Identification marks
k. Shop drawings and laying ad. Dewatering aw. Authorities' approval
diagrams

l. Installation ae. Submittals ax. Manufacturer's certificate


m. Concrete protection of af. Release of groundwater ay. Access to testing and manufacture
sewer pipe

209
22 DRAINAGE AND PIPING WORKS BELOW GROUND

n. Anchors and thrust blocks ag. Backfilling trench excavation az. Joints and jointing materials
o. Cutting pipes ah. Compaction ba. Testing pipelines
p. Deflection at certain joints ai. Miscellaneous bb. Manholes
q. Stream and river crossing aj. Soft refill material-special bc. As-Built Drawings
measures
r. Measurement of sewer ak. Surface reinstatement in
installation asphalt roads
s. Trench excavation al. Maintenance

3. External Water Reticulation


a. Excavation
b. Valve chambers
c. Marker post
d. Pipes, specials and valves
e. Handling, laying and pipe testing

Specific information to be 1. Rock level or estimated quantity of rock at the pipe trenches area.
shown in the 2D drawings 2. Details of all types of drains, piping works, manholes, sumps, marker posts, etc.
or to be input into the 3D 3. BS/MS codes for all types of pipes and valves, and brand and Class of culverts.
model

Specific rules of 1. The depth for excavation shall mean the invert depth of the pipe/drain; therefore, the actual depth of excavation shall add on
measurement the bed that the pipe/drain laid on.
2. Drains and pipes are measured from the external face of a manhole to the external face of manhole or accessory.

Works and materials 1. Excavating trenches


deemed included which a. Excavating in whatever type of material met with excluding rock as defined in the Specification met with on the surface
are collectively referred to or in the excavations.
as the 'Preambles' b. Getting the material out of the excavations.
c. Levelling bottoms of the excavations to falls or cambers, and compacting the same.
d. Trimming sides of the excavations from vertical, battering or sloping faces.

210
22 DRAINAGE AND PIPING WORKS BELOW GROUND

e. Upholding and maintaining sides of the excavations by whatever means necessary including the use of bentonite and
any special shoring or sheet piling etc. as may be necessary but which do not form a permanent part of the works to
be executed, but excluding any planking and strutting to be left in or any sheet piling etc. which form a permanent
part of the work to be executed.
f. Backfilling of selected excavated materials into the excavations and compacting the same by methods and in the
manners as specified in the Specification.
g. Multiple handling and transporting above the site.
h. Depositing, spreading and levelling in making up levels of surplus excavated materials within the site.
i. Keeping the excavations free from the storm, percolating or spring water by pumping or whatever other means
necessary.
j. Disposal of surplus excavated materials (the balance after backfilling) is to include for multiple handling of the
materials or transporting the material about the site as may be necessary prior to disposal.

2. Primary Stormwater Drainage and Culverts


a. Setting out the stormwater drainage works
b. All short lengths
c. Jointing and bedding and making smooth running joints
d. Building in ends of drain or culvert pipes into sumps.
e. Cutting culvert pipes for chamfers, ends, junction and for jointing
f. Additional beds and surrounds at junctions, beds, cascades, ends, etc.

3. Primary Soil Drainage


a. Pipework & Fitting Generally
(i) Setting out the primary soil drainage works
(ii) All necessary supports, saddles, slings, fixing bolts, foundation bolts for supporting pipework and equipment
during installation
(iii) All short lengths
(iv) Running joints
(v) Deflecting joints
(vi) Site tests on pipework including providing test certificates and carrying out tests on samples
(vii) Temporary stoppers or plugs for closing ends of uncompleted pipelines during the progress of works

211
22 DRAINAGE AND PIPING WORKS BELOW GROUND

(viii) Forming permanent vertical joints along with concrete pipe bedding as required.
(ix) Purpose-made brackets and hangers within chambers, etc.
(x) Building in ends of pipes into or concrete chambers including providing brick-on-edge arch and concrete lintels
over pipes and making good works around.
(xi) Cleaning out the interior of pipes and preparing ends of pipes for pipe joints and jointing.
(xii) Cutting pipes for chamfers, bends, junctions and for jointing, etc.
(xiii) All mechanical and flexible couplings and suchlike joints shall include all nut, bolts, plain and spring washers,
gaskets, etc. for making the complete connection.
(xiv) External protection on all flanged joints and flexible couplings.
(xv) All exposed cast iron or steel pipes in chambers or above ground etc. are deemed to include painting with three
coats of bituminous paint.
(xvi) Pipe fittings include bends, junctions, inspection pipes, rodding eyes and the like.

4. Testing and Commissioning of Pipelines and Manholes


a. The testing and commissioning of pipelines and manholes deemed to include the provision of all plant and
equipment comprising portable hydraulic pumps, blank, flanges, caps and plugs, pressure gauges, pipe
connections, corks, hoses, struts, thrust blocks and all labour and everything else necessary as described in
the Specification.

5. Water Reticulation and Fire Hydrants


a. Water Reticulation & Fitting Generally
(i) Setting out the water reticulation works.
(ii) Deflecting joints.
(iii) Site tests and works tests on pipework, mechanical couplings, etc. including providing test certificate and
carrying out tests on samples.
(iv) Temporary plugs or stoppers for closing cut ends of uncompleted pipelines during progress of works.
(v) Building in ends of the pipe into the concrete structure and making good works around.
(vi) Cutting pipes for chamfers, bends, junctions and for jointing.
(vii) Cleaning out the interior of pipes and preparing ends for pipe joints and jointing.
(viii) External protection on all running joints, flanged joints and flexible couplings.
(ix) Painting all uncoated surfaces of pipework, valves and fittings, etc. with two coats of bituminous paint before
or after laying and jointing.
(x) Valve, hydrants and such as specials are to include for all component pipes necessary for the complete
installation including all fixing accessories and extra joints to pipes.

212
22 DRAINAGE AND PIPING WORKS BELOW GROUND

(xi) Pipes are deemed to include for all running joints, short lengths, sockets, connectors, back nuts, elbows,
bends, tees, diminishing pieces, plugs and such as items.

2. Testing and Commissioning of Water Reticulation System


a. The testing and commissioning of the water reticulation system are deemed to include the provision of all plant
and equipment, portable hydraulic pumps, blank, flange, caps and plugs, pressure gauges, pipe connectors,
corks, hoses, struts, thrust blocks and all labour and everything else necessary as described in the
Specification.

213
22 DRAINAGE AND PIPING WORKS BELOW GROUND

ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED

01 Surface water drainage


02 External sewerage reticulation
03 External water reticulation

01 Excavating m3 01 For pipes and beds 01 (dia.) diameter 01 To add 'NOTES' preceding the
trenches pipes; (depth) Heading as follows:
average deep
(a) All excavation items shall
be deemed to commence
02 For precast concrete 01 (depth) average from reduced/platform
drains and beds deep level unless otherwise
stated.
03 For culverts (b) Any other requirements.

02 Extra-over for m3 01 Using pneumatic tools;


breaking up rock at removing from site
any depth and all 02 Using chemical means;
types of excavation removing from site

03 Using control blasting; to


Authority approval and
by the licensed
specialist; removing from
site

03 Imported graded m 01 Beds to pipes 01 (dimensioned


granular material description)
04 Imported sand 02 Beds and haunching to
(dia.) diameter pipes
05 Mass in-situ 03 Beds and surrounds to
concrete; Grade C (dia.) diameter pipes
(grade) P; including
04 Vertical casings to (dia.)
formwork diameter pipes

214
22 DRAINAGE AND PIPING WORKS BELOW GROUND

ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED
05 Beds and surrounds on
both sides of precast
concrete block drain;
including blinding

06 Precast concrete U m 01 Laid to falls on concrete 01 (width) Internal 01 Precast concrete U drain' and
drain beds {measured width x (depth) 'half-round precast concrete
07 Half-round precast separately}; in (length) deep to invert drain' shall deem to include all
concrete drain length moulds and finished fair on
08 Half-round glazed exposed faces.
ware drain
nr 02 Extra over for (height)
high cascades; including
all necessary concrete,
formwork and excavation

09 Precast concrete nr 01 Laid in between brick 01 (dimensional


struts; Grade C wall description)
(grade)P; including
reinforcement; as
shown in drawing
(drawing nr)/model

10 Precast concrete nr 01 To open drain; fair


slabs; Grade C finished to top
(grade) P including
reinforcement; as
shown in drawing
(drawing nr)/model

215
22 DRAINAGE AND PIPING WORKS BELOW GROUND

ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED
11 Cement and sand m2 01 Drain walls; including 01 half brick thick 01 Refer 'Preambles' for Masonry
brick (thickness) cement and which is applicable to these
12 Common clay brick sand rendering with an 02 one-brick thick items.
approved plasticiser 03 (thickness) thick
finished with steel trowel
on the exposed surfaces;
complete with (diameter)
diameter PVC as weep
holes with stone
aggregate wrapped with
a wire mesh filter.

216
22 DRAINAGE AND PIPING WORKS BELOW GROUND

ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED
13 Vitrified clay pipes m 01 Laid in trenches; 01 (diameter) diameter 01 The BS/MS code and the type
and fittings embedded in hand {nominal} of joints shall be described in
14 UPVC pipes and compacted (thickness) the Heading.
fittings granular bedding
15 Cast iron pipes and extending halfway up the
fittings side of the pipe; the
16 Precast concrete remainder side fill with
pipes and fittings selected backfill carefully
compacted; including all
necessary aggregate,
bends and other
accessories; all in
accordance to S.O.'s
approval; as shown in
Drawing (drawing
nr)/model.

17 Mild steel pipes m 01 Laid in trenches;


and fittings including all necessary
concrete-lined bends, junctions, tees,
internally and end caps and the
externally wrapped like; supported and
with bitumen including precast
impregnated concrete thrust block of
Hessian or other appropriate sizes;
equal and all in accordance to
approved S.O's approval; as
shown in Drawing
18 Heavy Duty (drawing nr)/model.
polyethylene
(HDPE) pipes and
fittings

217
22 DRAINAGE AND PIPING WORKS BELOW GROUND

ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED
19 Precast concrete m 01 (product name/code') 01 (dimensioned
box culverts Class (class) or other description)
equal and approved with {nominal}
dry weather flow; jointed
with cement and sand
(1:3) mortar laid in
trenches; including
(Thickness) concrete
blinding, (Thickness)
vibrated reinforced
concrete Grade 20 bed
with one layer of (BMC
Ref. No) including all
necessary excavation,
backfilling, formwork,
planking and strutting;
complete with precast
concrete lids; all in
accordance with the
manufacturer's
instructions

218
22 DRAINAGE AND PIPING WORKS BELOW GROUND

ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED
20 Precast concrete m 01 (product name/code) 01 (diameter) diameter
pipe culverts 'Class' (class) or other {nominal}; average
equal and approved; (depth) deep
jointed with and including
precast concrete collars
in cement and sand (1:3)
mortar laid and jointed in
trenches; including
(thickness) thick concrete
blinding, (thickness)
vibrated reinforced
concrete Grade 20

21 Brick manholes nr 01 Constructed of (size) 01 (dimensioned 01 If there are mild steel or


brick thick (type) brick description) stainless-steel steps, they
wall in cement and {internal} shall be so described in level
mortar (1:3); plastered One.
internally with (thickness)
thick high alumina
cement; on and including
(thickness) thick vibrated
reinforced concrete
Grade C(grade)P bed
with one layer of BMC
(nr)

219
22 DRAINAGE AND PIPING WORKS BELOW GROUND

ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED
22 Precast manholes nr 01 Constructed of precast 01 (dimensioned
reinforced concrete rings description)
and eccentric cone; {internal}
plastered internally with 02 (dimensioned
(thickness) thick high description) drop
alumina cement; precast manholes {internal}
reinforced cover slab; on
and including (thickness)
thick vibrated reinforced
concrete Grade C(grade)
P bed with one layer of
BMC (nr) with thickness)
blinding; raised with
(thickness) thick concrete
surround encasement;
complete with stainless
steel steps at (centre)
centres; approved heavy
duty ductile iron manhole
cover and frame to
manufacturer's detail;
including all necessary
excavation, formwork,
shoring; as shown in
Drawing (drawing
nr)/model

220
22 DRAINAGE AND PIPING WORKS BELOW GROUND

ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED
23 Brick sumps nr 01 Constructed of one brick 01 (dimensioned
thick (type) brick walls in description)
cement and mortar (1:3); {internal}
plastered internally with
(thickness) thick cement
and sand (1:6) plaster;
on and including
(thickness) thick vibrated
reinforced concrete
Grade C(grade) P bed
with one layer of BMC
(nr) with (thickness)
blinding; complete with
concrete benching,
uPVC half-round main
channel and galvanised
iron grating to suit
opening; including all
necessary excavation,
formwork and concrete
surround; as shown in
Drawing (drawing
nr)/model

221
22 DRAINAGE AND PIPING WORKS BELOW GROUND

ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED
02 Constructed of one brick
thick clay brick walls in
cement and mortar (1:3);
plastered internally with
(thickness) thick cement
and sand (1:6) plaster;
on and including
(thickness) thick vibrated
reinforced concrete
Grade C (grade) P bed
with one layer of BMC
(nr) with (thickness)
blinding; complete with
concrete benching,
uPVC half-round main
channel, (diameter) PVC
as weep holes complete
with (weight/m2)
geomembrane and
(thickness) thick
aggregate surround and
p.c. concrete slabs cover
to suit opening; including
all necessary excavation,
formwork and concrete
surround; as shown In
Drawing(drawing
nr)/model

222
22 DRAINAGE AND PIPING WORKS BELOW GROUND

ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED
03 Constructed of
(thickness) thick, and
(thickness) thick (type)
brick wall in cement and
mortar (1;3); plastered
internally with (thickness)
thick cement and sand
(1:6) plaster; on and
including (thickness)
thick vibrated reinforced
concrete Grade
C(grade)P bed with one
layer of BMC (nr) with
(thickness) blinding;
complete with
(weight/m2)
geomembrane and
(thickness) thick
aggregate surround and
p.c. concrete slabs cover
to suit opening; including
all necessary excavation,
formwork and concrete
surround; as shown in
Drawing (drawing
nr)/model

223
23 SITE WORKS

23 SITE WORKS

01 Roads, driveway and carpark


02 Hard landscaping
03 Sports surfacing
04 Resurfacing existing roads
05 Road signages

Information to be provided in the 1. General


Specification
2. Contractor Designed Keystone Retaining Wall
a. Performance Specification covering the following:
i. Scope of work vi. Performance criteria
ii. Submittals vii. Delivery, storage and handling
iii. Codes and standards viii. Materials
iv. Design requirements ix. Fabrication
v. Testing x. Warranties

3. Subgrade
4. Subbase
5. Crushed aggregate base course
6. Binder and wearing course
7. Various sport surfacing materials
8. Various road signages

Specific information to be shown 1. For Keystone Retaining wall, the location, area and height where are
in the 2D drawings or to be input required.
into the 3D models 2. For other hard landscaping works, the types and the product names (if required) and their details.
3. For Roads, driveway and carparks, the existing/platform levels, the details of the road, driveway and carpark and
kerbs, and the road marking.
4. For sport surfacing materials, the types and the product names (if required).
5. For resurfacing the existing road, the area for such work, the thickness of the premix, and the area where cutting and
bonding to the existing road.
6. For road signage, the types and the materials to be used for each signages.

224
23 SITE WORKS

Specific rules of measurement 1. For Contractor Designed Keystone


a. Retaining Wall
i. As these are contractor designed items, they are priced as 'lump sum' items with the cost breakdown given
and in the event of any variation which does not affect the overall design, it would be evaluated based on
the unit rate derived from dividing the 'lump sum' price by the approximate area (measured on front face)
given in the Level 1 of the item description.

Works and materials deemed 1. For others


included' which are collectively a. The areas measured are those in contact with the base.
referred to as 'Preambles' c. All thickness stated are nominal or finished after laying and compacting.

2. Unless stated as deemed included all associated excavations, disposal and fillings are measured in accordance with
Work Section 4: Excavating and filling.

3. Roads and path paving


a. All cutting and fitting
b. Sampling and testing of aggregates and bituminous mixtures as
specified
c. Protecting mixed material in transit and while awaiting tipping
d. Laying, rolling and consolidating sub-base, base course, binder and wearing course in layers or sequence as
required
e. Laying by the hand of narrow strips remaining alongside machine work
f. Making joints, working around manhole covers and other like projections
g. Finishing surfaces to gradient and falls
h. Added fillers to a bituminous mixture
i. Maintenance of surfaces as work progresses
j. Ends, angles, outlets and intersections
k. Setting pavings into recessed manhole covers

4. Road kerbs
a. Road kerbs are deemed to include all necessary excavation, backfilling, formwork, miters, bends, circular section,
etc.

225
23 SITE WORKS

ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL Notes, comments, and glossary
MEASURED THREE

01 Roads, drivewyas and carparks

01 Roads, driveways m2 01 Bulk excavation; to 01 oversite; average


and carparks road formation level (depth) deep
to form subgrade; get
out, load and cart
away surplus
excavated material
from site

m2 02 Grade road formation 01 on subgrade


level to gradient and
crossfall; well rolled

m2 03 Sand blinding; 01 (thickness) thick


spread and levelled {consolidated
to fall, well rolled and thickness}
compacted

m2 04 Crusher run; spread 01 (thickness) thick


and levelled to fall, {consolidated
well compacted thickness}

226
23 SITE WORKS

ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED
m2 05 Prepare, apply and 01 at a rate of (nr)
spread a layer of litre/m2
approved bituminous
tack coat on crusher
run surface

m2 06 Premix binder 01 (thickness) thick


course; laid on {consolidated
crusher run to thickness}
gradient and
crossfall, well rolled
and compacted

m2 07 Premix wearing 01 (thickness) thick


course; laid on binder {consolidated
course to gradient thickness}
and crossfall, well
rolled and
compacted; including
a layer of approved
tack coat

227
23 SITE WORKS

ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED
nr 08 Prepare and apply 01 (width) wide edge
(nr) coats of lines
thermoplastic 02 (width) wide edge
reflective paint on the lines
surface of premix; as 03 (width) wide stop
shown in Drawing lines
(drawing nr)/model 04 (width) wide centre
lines at (length)
spacing
05 (width) wide parking
lines
06 straight directional
arrows
07 turning directional
arrows
08 numbering for
parking lots

m 09 Cast-in-situ extruded 01 overall size, (width)


kerbs; laid on and wide x (height) high
including (width) wide
x (thickness) thick
plain in-situ concrete
Grade C (grade) P
bed; forming outlet
opening at (centre)
c/c; painting with
approved black and
white emulsion paint
in (nr) layers on
exposed surface; as
shown in Drawing
(drawing nr)/model

228
23 SITE WORKS

ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED
10 Precast concrete
kerbs with one side
batter and rounded
on one edge cost
inconvenient length
and jointed in cement
mortar (1:3); laid o
and (width) wide x
(thickness) thick plain
in-situ concrete
Grade C (grade) P
bed; forming outlet
opening at (centre)
c/c/; painting with
approved black and
white emulsion paint
in (nr) layers on
exposed surface; as
shown in Drawing
(drawing nr)/model

229
23 SITE WORKS

ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL Notes, comments, and glossary
MEASURED THREE

02 Hard landscaping

01 Contractor Designed item 01 Design, 01 Breakdown cost 01 To add 'NOTES' preceding the Level One
Keystone Retaining manufacture, as follows:
Walls supply and install
Keystone (i) Design fee a The Contractor shall engage a Specialist
Retaining Walls (ii) Investigation Sub-Contractor who has the expertise
{approximate area works and experience to design, supply and
(area) m2}; as (iii) Excavation work install such wall in accordance with the
shown in Drawing to facilitate the Performance Specification in the
(drawing nr)/model construction of Specification and the relevant drawings
Keystone and to the approval of the S.O.
Retaining Wall
(iv) Manufacture, b The Contractor and his Specialist Sub-
supply and Contractor shall jointly be responsible to
deliver to site ensure that such walls are in all respect
Keystone adequate, accurate, sufficient and fit for its
Retaining Wall purpose.
components
(v) Piling (if any) c The Contractor shall submit all shop
(vi) Erection and drawings and sample as per
installation of requirements stated in the Performance
Keystone Specification and be endorsed by
Retaining Wall Engineer, Malaysia.

(v) Supply and d Before pricing, the Contractor is required


install mass to visit the site and refer to the drawings
concrete for the extent, the location and the
levelling pad varying heights shown therein so as to
satisfy himself as regards to facilities for
transport and plant movement, means of
access.

230
23 SITE WORKS

ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED
(vi) Supply, fill, e Any other requirements (if any).
spread, level
and compact
granular backfill
(vii) Geogrids as
reinforcing
elements
(viii) Other works to
be listed by the
Contractor that
are necessary
to ensure
completion of
the Keystone
Retaining Wall

02 Setting nr 01 Seats; precast 01 overall size;


concrete; Grade (dimensioned
(grade) P; finished description)
with (type) plaster;
including
foundation, (type)
brick wall supports
plastered on all
exposed sides; as
shown in Drawing
(drawing nr)/model

231
23 SITE WORKS

ITEM OR WORK TO UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
BE MEASURED
03 Steps m2 01 (type) brick steps; 01 overall width
comprising (height) risers (width)
and (width) threads;
jointing in cement and
sand mortar (1:3) and
finished with (thickness)
thick (type) paving; as
shown in Drawing
(drawing nr)/model

04 Pavings m2 01 (product name) or other 01 on compacted


equal and approved subgrade
stamped concrete 02 on concrete base
pavings; finished with
bull floating and
embossed to the
required pattern and
colour as selected by the
S.O.-; finished with a
protective coating;
including all necessary
expansion joints with
approved sealant; all in
accordance with the
manufacturer's
instruction and S.O.'s
approval; as shown in
Drawing (drawing
nr)/model

232
23 SITE WORKS

ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED
02 (product name) or 01 on compacted
other equal and crusher run
approved interlocking 02 on concrete base
concrete pavers; laid 03 on compacted
on and including subgrade
(thickness) thick sand
bedding to the
required pattern and
colour as selected by
the S.O.; all in
accordance with the
manufacturer's
instructions and
S.O.'s approval; as
shown in Drawing
(drawing nr)/model

03 Footpaths; 01 finished with (type)


(thickness) thick paving
reinforced concrete
Grade (grade) P
slabs with (nr) layer
of BMC (ref nr); laid
on and including
(thickness) thick lean
concrete and
(thickness) thick
hardcore; including
all necessary
excavation and
formwork; as shown
in Drawing (drawing
nr)/model

233
23 SITE WORKS

ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED

03 Sport surfacing

01 Running track m2 01 Seamless, water 01 Comprising 01 on subgrade


impermeable prefabricated based
synthetic running layer, pore sealer
track system and wear cost
broadcasted with
EPDM granules; all in
accordance to
manufacturer’s
instructions

02 Badminton court m2 01 Cushion-backed 01 on concrete


mat indoor PVC synthetic
sport flooring system;
all in accordance to
manufacturer’s
instructions

03 Tennis court M2 01 Acrylic rubberized 01 On concrete


sport flooring made
of acrylic resin coats;
all in accordance to
manufacturer’s
instructions

234
23 SITE WORKS

ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED

04 Resurfacing existing roads

01 Resurfacing existing m2 01 Scarifying existing 01 to receive a new


roads road surface wearing course
(measured
separately); including
applying a layer of
approved bituminous
tack coat at the rate
(nr) litre/m2

m2 02 Premix asphalt 01 (thickness) thick


macadam wearing
course; laid on
scarified surfaces

item 03 Cutting in and 01 allow


bonding of
new/resurfaced
premix/existing road;
including making
good

235
23 SITE WORKS

ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED

05 Road signages

01 Supply and install nr 01 Supported by m.s 01 The other end 01 ‘BERHENTI’ sign
road signage post with one end mounted with non- 02 ‘No ENTRY’ sign
embedded in mass illuminated retro- 03 ‘No LEFT TURN’
concrete footing; reflective aluminium sign
including all sheet; as shown in 04 ‘NO THROUGH
necessary the drawing (drawing ROAD’ sign
excavation, nr/model) and in 05 ‘ROAD
formwork, welding accordance to Local INTERSECTION’
and fittings; painting Authority’s sign
to exposed surfaces requirement for

236
24 FENCING, TURFING AND PAINTING
24 FENCING, TURFING AND PLANTING

01 Fencing
02 Turfing and planting
03 Maintenance

Information to be provided in 1. Fencing


the Specification
a. General
b. Mild steel post and bracings
c. Types of fencing
d. Gates
e. Painting of fence and gates

2. Turfing and planting

a. General
b. Classifications and characteristics of plants
c. Size of plants
d. Handling and planting
e. Soil mixture, soil conditioners and chemical fertilizers
f. Turfing
g. Football and playing fields
h. Maintenance of plant and turf
i. Final handing over

Specific information to be 1. Fencing


shown in the drawings or to be
input into the 3D model a. For fencing, type of fencing and gates (if any) and their details

237
24 FENCING, TURFING AND PAINTING
2. Turfing and planting

a. Botanical name of turf, seeding, trees, shrubs, bulbs and/or tubers


b. Component details
c. Planting schedule
Specific rules of measurement 1. Fencing

a. Fencing is measured overall supports.


b. The height of fencing is measured from the finished surface of the ground to the top of the posts.

2. Landscape

a. Deduction is made for voids irrespective of the sizes.


b. The areas measured are those in contact with the base.
c. All thickness stated are nominal or finished after laying and compacting.

Works and materials deemed 1. Fencing


included' which are collectively
referred to as 'Preambles' a. Painting' is deemed to be the painting system to the relevant surfaces as provided in Work Section 21:
Decoration.
b. The 'Preambles' for Excavation items, In-situ Concrete items, Masonry items, Metal items, Finishing items and
Decoration items under this Work Sections are to follow the respective 'Preambles' in the relevant Work
Sections.

2. Landscape

a. All work is deemed external unless described as internal.


b. Carrying out of the Works in such sequence or section as the Architect/S.O. may direct.
c. Preparatory work in forking and loosening ground surface.
d. Dressing with fertilizer, tending, watering, covering with wet sacking, moving and protection of newly turfed
areas.
e. Raking in, harrowing and rolling for seeding.

238
24 FENCING, TURFING AND PAINTING
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary

01 Fencing

01 P.V.C. coated chain m 01 Supported by 01 (gauge) gauge 01 If the fencing is 'to sloping
link fencing (dimensional (dimensioned ground'-, 'set out to curve
description) mild steel description) mesh but straight between posts'
angle post with one overall (height) high. or 'set out to curve between
end embedded into posts'-, it shall be so
concrete Grade 15 described in Level Three.
footing at (length)
centre to centre
including all excavation
and formwork and
painting; complete with
(gauge) PVC coated
galvanised straining
wire thread; as shown
in Drawing (drawing nr)

02 Brick fencing with a m 01 Constructed of the 01 overall (height) high


mild steel grille upper half with mild
steel grille and the
lower half with half
brick thick (type) brick
at (height) high
complete with
plastering on both
sides and laid on and
including vibrated
reinforced Grade 20P
strip foundation with
one layer of BMC Ref
Nr (reference nr)
including all
excavation, blinding
and painting; as shown
in Drawing (drawing nr)
239
24 FENCING, TURFING AND PAINTING
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
03 (Brand name) anti- 01 Constructed of high 01 If the fencing is 'to sloping
climb fence (series nr) tensile steel wire ground', 'set out to curve
or other equal and finished in hot-dipped but straight between posts'
approved; galvanised; complete or 'set out to curve between
with posts with one end posts', it shall be so
embedded into described in Level Three.
concrete Grade 15
footing at (length)
centre-to-centre
including all excavation
and formwork and all
accessories; all in
accordance with the
manufacturer's
instructions

04 Mild steel gate 01 Complete with 1 pair 01 overall size, (length


purpose made hinges, and height) high
drop bolt, locking plate 02 pair; overall size,
and other necessary (length and height)
accessories and high
painting; as shown in
Drawing (drawing nr)

240
24 FENCING, TURFING AND PAINTING
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary

02 Turfing and planting

01 Close turfing 01 Preparing ground; 01 with (botanical name) 01 If the glass is laid 'on
including all necessary grass sloping surfaces; including
excavation, backfilling, securing turves with pegs', it
trimming and shall be so described in
(thickness) thick of Level Two.
black vegetable solid;
well-watered and
02 Spot turfing
applying approved
fertilizer until well
established

03 Grass seeding 01 applied at the rate of


(nr) per m2

04 Trees 01 Preparing ground; 01 (botanical name);


including all necessary (girth) girth; (height)
excavation, backfilling, trunk height
05 Shrubs trimming and black
vegetable soil;
complete with
supports, labelling, ties,
guards, etc. well-
watered, pruning and
applying approved
fertilizer until well
established

06 Bulbs ad tubers

241
24 FENCING, TURFING AND PAINTING

ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary

03 Maintenance

07 Maintenance of m2 01 Watering, pruning, 01 until the issuance of


turves replacing damaged or the Certificate of
defective trees and Practical Completion
08 Maintenance of trees plants, applying
and plants fertilizers and weed
killers and all other
maintenance as
specified

02 from the issuance of


the Certificate of
Practical Completion
until the issue of the
Certificate of Making
Good Defects

242
25 PLUMBING SERVICES
25 PLUMBING SERVICES

01 Cold/hot water installation


02 Sanitary pipework installation
03 Sanitary fittings

Information to be provided in the 1. General, Regulations and Requirements


Specification 2. Scope of Work
3. Technical Specification

Specific information to be shown 1. For cold/hot water installation, the type, the 'Class' and the 'BS/MS Code' of pipes, the diameter of each pipe;
in the 2D drawings or to be input type of taps and valves and their respective type of material; type of water tank and capacity; type of insulation
into the 3D model and the areas that required insulation.
2. For sanitary pipework installation, the type, and the 'BS/MS Code' of pipes and the type of pipe joints, the
diameter of each pipe; reducers, caps, and the like; accessories e.g. floor trap, gully trap, grease trap and
respective details; manholes and their details.
3. For sanitary fittings, schedule of sanitary fittings with the product names/codes and details (where necessary)
4. From Builder's Work In Connection With Sanitary Fittings, the detail of the Builder's work in connection with
sanitary fittings.

243
25 PLUMBING SERVICES
Specific rules of measurement 1. All piped works are measured overall pipe fittings.
2. Flexible pipes and extensible pipes are measured when they are not extended.

Works and materials deemed 1. The following are deemed to be included for pipe works
included' which are collectively a. Running joints, connectors, elbows and bends, sockets, backnuts, fire bends, tees, diminishing pieces,
referred to as 'Preambles' plugs, brackets, offsets, beaded ends, ornamental ends and the like
b. Joints of a special or ornamental character
c. Fittings involving a change of direction of piping
d. All short lengths
e. Sundry items of a like nature
f. For concealed pipework, all cutting to form chases and holes and subsequent making good of all works
disturbed

244
25 PLUMBING SERVICES
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary

01 Cold/hot water installation

01 Coated ductile pipe m 01 Laid in trenches; 01 (dia.) diameter 01 BS/MS Code' nr and the
and fittings; including necessary type of 'Class' shall be
mechanical coupling excavation and stated in the 'Heading'.
plain-end joints reinstatement
02 Steel pipe and fittings; 02 (dia.) diameter; fixed
mechanical coupling in vertical surface
plain-end joints
03 Medium-density 03 (dia.) diameter; fixed
polyethylene pipe and in horizontal surface
fittings; plastic
compression fittings
and joints
04 High-density 04 (dia.) diameter;
polyethylene (HDPE) embedded in wall/floor
pipe and fittings;
plastic compression
fittings and joints
05 Asbestos cement pipe
and fittings; rubber
ring coupling plain-end
joints
06 Galvanised mild steel
pipe and fittings;
screwed socketed
joints
07 UPVC pipe and
fittings; solvent welded
joints
08 Copper pipe and
fittings compression
fittings and joints

245
25 PLUMBING SERVICES
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
09 Acrylonitrile butadiene
styrene (ABC) pipe
and fittings; solvent
welded joints

10 Stopcocks, valves and nr 01 Bib taps 01 (dia.) diameter; 01 Type of material and
the like jointing to (type) 'BS/MS Code' nr shall be
pipes stated in Level One.
02 Stop valves
03 Gate valves
04 Butterfly valves

11 Water tanks nr 01 Galvanised pressed 01 Complete with 01 (dimensioned


steel sectional water covers, float description)
tank operated ball valves
02 Galvanised steel to (BS/MS code)
water tank with union
03 Glass fibre reinforced connections to 02 (litre) litres
plastic sectional water pipes; including nominal capacity
tank bearers and
04 Polyethylene water supports of any
tank kind

12 Insulation m 01 Preformed sectional 01 To pipes and 01 (dia.) diameter


pipe insulation; supports pipes
(thickness) thick and
(type) type; including 02 To flanged
(thickness) thick pipework and
protective covering supports
03 To boilers, cylinder, 01 overall size;
tanks and the like (dimensioned
description)

246
25 PLUMBING SERVICES
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
13 Testing and item 01 allow for testing the
commissioning whole of the cold/hot
water installation
system during laying
and on completion;
making good any
defects and leaving
everything in perfect
working order to the
entire satisfaction of
the S.O. and Local
Authority

02 Sanitary pipework installation

01 Cast iron pipes and m 01 With caulked lead 01 Soil and vent pipe 01 (dia.) diameter laid 01 BS Code' nr shall be stated
fittings joints in trenches in the Heading.
02 With flexible joints 02 Waste and vent including
pipe necessary
02 UPVC pipes and m 01 With rubber ring joints excavation and
fittings reinstatement
02 With solvent welded 02 (dia.) diameter
joints fixed in vertical
surface
03 (dia.) diameter
fixed in horizontal
surface

nr 04 extra-over for
reducers; (dia.)
diameter
05 extra-over for caps

247
25 PLUMBING SERVICES
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
06 extra-over for
access pipes;
complete with
inspection door
03 Accessories nr 01 Approved PVC Floor 01 Complete with 01 overall size (dia.)
trap approved stainless diameter
steel floor grating
setting in concrete 02 overall size
slab (dimensioned
description)

02 Complete with stop-


roach device setting
in concrete slab
02 Approved PVC Gully 01 Complete with half-
trap brick wall with
20mm thick high
alumina cement
rendering, concrete
base, concrete
cover slab and
stainless steel floor
grating
03 Grease trap 01 Complete with half-
brick wall with
20mm thick high
alumina cement
rendering, mild
steel chequer plate
and stainless steel
strainer bracket; as
shown in Drawing
(drawing nr)/model

248
25 PLUMBING SERVICES
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
04 Balloon gratings 01 galvanised wire
balloon grating; to
suit (dia.) diameter
pipes
04 Manhole/Septic Tank (Refer to Work Section 22: Drainage and piping works below ground)

05 Testing and item 01 allow for testing the


commissioning whole of the soil,
waste and ventilation
pipe system during
laying and on
completion; making
good any defects and
leaving everything in
perfect working order
to the entire
satisfaction of the
S.O. and the Local
Authority

249
25 PLUMBING SERVICES
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary

03 Sanitary fittings

01 Supply and Fix the nr 01 Vitreous china wash 01 (product 01 Level Two is an example as
following sanitary basin from name/code)' ; to the information that is
fittings in white (manufacturer's name) (dimensioned required to be provided for
colour unless or other equal and description) complete the particular type of
otherwise stated; approved with 3 semi-punched sanitary fitting as stated in
including tap holes, 13mm Level One. Different product
connections to pipes chrome plated waste name/code in Level Two will
with adaptors as fittings with chain and have different information
necessary jointing rubber plug waste, but this example will form a
and sealing 32mm plastic bottle template for the
compounds and all trap and ( product adjustments to suit.
necessary name) single-lever
accessories 13mm pillar tap; fixed
on and including a
pair of fixing bolts
WST 10 x 140
plugged and screwed
to tiled wall; all in
accordance to the
manufacturer's
instruction and
Architect's approval

250
25 PLUMBING SERVICES
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
nr 02 Vitreous china water 01 (Product
closet from Name/Code)'; close-
(manufacturer's name) or coupled washdown
other equal and approved pedestal WC with 'S'
trap, complete with 6
litre single flush
cistern and lid,'
(Product
Name/Code)' 13mm
chrome plated angle
valve with wall
flange, 13mm
stainless steel
reinforced flexible
hose, 300mm long,
and seat and cover
(soft close seat);
plugged and
secured closet to
tiled concrete floor
and jointing pan to
soil pipe complete
with all necessary
fixing and making all
connections; all in
accordance to the
manufacturer's
instruction and to the
Architect's approval

251
25 PLUMBING SERVICES
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
nr 03 Vitreous china soap holder 01 (dimensioned
from (manufacturer's description) semi-
name) or other equal and recessed soap dish
approved
02 semi-recessed
soap and sponge
holder

nr 04 Vitreous china urinal bowl 03 (product


from (manufacturer's name/code)'; wall
name) or other equal and hung top inlet urinal
approved bowl with ceramic
waste, plastic
flange, screws,
washer & mastic,
light urinal hangers,
fixing bolts and
cleansing nozzle;
'(product
name/code)
exposed 4 LPF 3/4"
top inlet flush
meter, straight flush
pipe and 3/4"
chrome plated inlet
pipe secured on g.i.
brackets to tiled
wall complete with
all necessary fixing
and making all
connections; all in
accordance to the
manufacturer's
instruction and to
the Architect's
approval

252
25 PLUMBING SERVICES
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
nr 05 Vitreous china toilet roll 01 (dimensioned
holder from description) semi-
(manufacturer's name) or recessed toilet roll
other equal and approved holder with rounded
corner
nr 06 Stainless steel urinal stall; 01 overall size 01 Level One is an example
including heavy gauge mild (dimensioned as to the information that is
steel stiffener; complete description); required to be provided for
with (Product Name/Code) including the particular type of
delayed shut-off valve and (dimensioned sanitary fitting. Different
all accessories; as shown description) Product Name/Code in
in drawing (drawing nr) concrete infill Level One will have
different information but
this example will form a
template for the
adjustments to suit.
nr 07 (product name/code)' or 01 (length) long
other equal and approved
acrylic long bath; complete
with pop-up waste,
overflow, trap, wall
mounted bath or shower
mixer with a flexible hose,
hand shower and bracket;
fixing and make all
connections

253
25 PLUMBING SERVICES
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
nr 08 (product name/code)' or 01 overall size
other equal and approved (dimensioned
stainless steel kitchen sink; description); single
complete with and bowl single drainer
including bracket, 38mm
PVC bottle trap and 02 overall size
standard waste fittings with (dimensioned
plugs and chain; 1 nr description); double
(product name/code) 1/2" bowl double drainer
wall mounted sink tap with
swivel spout, ball lever
handle and quarter turn
ceramic disc; fixing and
making all connections

nr 09 (product name/code)' or 01 (dia.) diameter


other equal and approved
bib tap; complete with all
necessary fixing and
making all connections

nr 10 (product name/code)' or 01 generally


other equal and approved
bidet hose with cleaning
nozzle, wall hook, 1/2"
angle valve with ball level
handle and quarter turn
ceramic disc; fixing to
piping

254
25 PLUMBING SERVICES
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
nr 11 (product name/code)' or
other equal and approved
shower-head; complete
with chromium-plated
screw down stopcock and
2 1/4" diameter CP brass
shower rose arm and
flange

nr 12 First quality '(product 01 (dimensioned


name/code)' or other equal description)
and approved polished
float glass mirror; complete
with aluminium edges and
8mm thick waterproofed
plywood backing; plugged
and four times screwed to
tiled/plastered wall;
including chromium dome
capping to screws

nr 13 (product name/code)' or 01 generally


other equal and approved
alpine robe hook; fixed to
the wall

nr 14 product name/code)' or 01 generally


other equal and approved
wall mounted paper towel
dispenser; including all
fixing

255
25 PLUMBING SERVICES
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
nr 15 (product name/code)' or 01 generally
other equal and approved
wall mounted liquid soap
dispenser with ouch
bottom type valve;
including all fixing

nr 16 (product name/code)' or 01 generally


other equal and approved
electronic hot air hand
dryer with hygienic non-
contact on/off switch;
including all necessary
fixing accessories and
connection

nr 17 (product name/code)' or 01 comprising


other equal and approved '(product
wall to wall grab rail; name/code)
including plugged and (length) long x
screwed tiled wall (dia.) diameter
stainless steel
angled grab rail
and '(product
name/code)'
(length) long x
(dia.) diameter
stainless steel
straight grab rail

256
25 PLUMBING SERVICES
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
02 Builder's Work In nr 01 Mass concrete stool 01 Constructed of 01 overall size
Connection With vibrated reinforced (dimensioned
Sanitary Fittings in-situ concrete description)
Grade 15P to
receive water
closet; including all
necessary
formwork; finished
on all exposed
surface with (type &
size of tiles) tiles
bedded and jointed
in cement and sand
(1:3) screeded bed
pointed in matching
colour cement
mortar and other
necessary works

257
25 PLUMBING SERVICES
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and
MEASURED glossary
02 Vanity countertop 01 Constructed of 01 overall size
vibrated reinforced (dimensioned
concrete Grade description)
25P; including all
necessary
formwork and
reinforcement;
forming opening to
receive vanity basin
(measured
separately) finished
on the exposed
surface with (type &
size of tiles) tiles
bedded and jointed
in cement and sand
(1:3) screeded bed
pointed in matching
colour cement
mortar and other
necessary works

258
26 MECHANICAL ENGINEERING INSTALLATIONS
26 MECHANICAL ENGINEERING INSTALLATIONS

01 Primary Equipment
02 Ducting
03 Pipeworks
04 Insulation to Ductworks
05 Insulation to Pipeworks
06 Ducting Accessories
07 Anti Vibration
08 Sundries

Information to be provided in the 1. Floor and site plan detailing the layout of systems
Specification 2. System schematics
3. Cross-sections and elevations
4. Detail layouts for plant rooms and main services installation areas.
5. Specific installation details for equipment and fittings.
6. Equipment schedules.
7. Type, quality and size or thickness of materials.
8. Regulations, Standard of Compliance etc.
9. Gauge, thickness or substance of the material
10. Any tests, performance test, witness test, specific test, etc.
11. Capacities, running condition, operational and static load etc. for main services installation

Specific information to be shown 1. For Air Conditioning, type, cooling capacity, type of gas use, type of pipe and BS/MS code and type of
in the 2D drawings or to be input accessories etc.
into the 3D model 2. For Gas Supply System, Refrigeration Installations & Chemical Installations, type of system, tank capacity, size
of pipe and MS/BS code, special fittings and accessories
3. For Fire Fighting System, type of system, tank capacity, size of pipe and MS/BS code, brass works for fittings
and accessories
4. For Medical Suction Installations, Pneumatic Tube Installations, Refuse Disposal Installations, Automatic Control
system, type of system, size of pipe or ducting and MS/BS code, special fitting and accessories

259
26 MECHANICAL ENGINEERING INSTALLATIONS
Specific rules of measurement 1. For Primary Equipment
a. Connection inside the primary equipment’s shall be deemed to be included.

2. For Pipe Works


a. Pipes measured over all pipe fittings, short running lengths and branches.
b. Flexible pipes and extensible pipes are measured when they are not extended.

3. For Duct Works


a. Ducting shall be measured over all pipe fittings, short running lengths and branches.
b. Flexible ducting and extensible ducting measured as fully extended.

Works and materials deemed 1. Classification of Works


included and general rules of a. Work together with its metalwork, supports and the like (unless associated with more than one installation)
measurement, all of which are to shall be classified as follows and given under an appropriate heading.
be stated in the Preambles (i) Air Conditioning Installations
(ii) Gas Supply System
(iii) Fire Protection Services
(iv) Refrigeration Installations
(v) Chemical Installations
(vi) Medical Suction Installations
(vii) Pneumatic Tube Installations
(viii) Refuse Disposal Installations
(ix) Kitchen Exhaust System
(x) Automatic Control Installations

2. Primary Equipment
a. All accessories deem to be included
b. Items of equipment and ancillaries shall be described with manufacturer's detailed specification

3. Pipe Works
a. The following are deemed to be included for pipe works
(i.) Labours on pipes (e.g. made bends, made springs, made offsets, beaded ends, ornamental ends,
etc.)
(ii.) Joints of a special or ornamental character.
(iii.) Pipe fittings over the pipe in which they occur. Cutting and forming openings and jointing piping to
fitting.
(iv.) Fittings involving a change of direction of piping.
(v.) Testing procedure, testing capacity, testing method

260
26 MECHANICAL ENGINEERING INSTALLATIONS
4. Duct Works
a. The following are deemed to be included:
(i.) Duct fittings over the duct in which they occur. Cutting and forming openings and jointing ducting to
fitting.
(ii.) Fittings involving a change of direction of ducting.
(iii.) Special connection and special joints in ducting.
(iv.) Labours on ductworks (e.g. made bends, made springs, made offsets, beaded ends, ornamental ends,
etc.)
(v.) Duct Service openings (if required.), ceiling opening etc.
(vi.) Fire Damper, electronic filter, Hepa Filter (if required).
(vii.) Testing procedure, testing capacity, testing method etc.

5. Equipment to Ducting
a. The following aredeemed to be included:
(i.) Type, size and method of fixing.
(ii.) All connections and jointing to the ducting works.

6. Insulation to Ducting, Piping and Equipment’s


a. The following are deemed to be included:
(i.) Working insulation around ducting fittings, special fittings and ancillaries.
(ii.) Includes smoothing the material and working around supports.
(iii.) Working insulation over flanges and pipe fittings.
(iv.) Working insulation around ancillaries.
(v.) Providing detachable mattresses and working insulation around special fittings and ancillaries.
(vi.) Room Sound Insulation (if required).

261
26 MECHANICAL ENGINEERING INSTALLATIONS
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED

01 Primary Equipment

01 Air Conditioning nr 01 Unit system 01 (Product 01 fixed to a Location of works, whether


Installations 02 Package system Name/Code) or horizontal internally, externally or in a plant
03 Central system other equal and surface room shall be so described in
04 Central system approved, 02 fixed to a Level Three
(modified) (dimensioned vertical surface
description), 03 fixed to plain
(capacity) ton, metal
(load) rating, 04 fixed to glass
associated
integrated or
remote
ancillaries,
controls, and
indicators or
components

262
26 MECHANICAL ENGINEERING INSTALLATIONS
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED
02 Gas Supply System nr 01 Meters 01 (Product 01 fixed on the
Name/Code) or external wall
02 Main gas other equal and
03 Condensate receiver approved,
(dimensioned
description),
(capacity) tonne,
(load) rating,
associated
integrated or
remote
ancillaries,
controls, and
indicators or
components

03 Fire Protection Services nr 01 Sprinklers 01 Wet pipe system 01 hanged to roof


02 Drenchers 02 Dry pipe system structure
02 hanged to floor
slab

03 Hose reels 01 Wet standpipe 01 fixed to


04 Hydrants 02 Dry standpipe horizontal
surface
05 Portable (state the type & 02 fixed to vertical
extinguishers capacity) surface
03 fixed to plain
metal
04 fixed to glass

263
26 MECHANICAL ENGINEERING INSTALLATIONS
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED
nr 06 Fire alarms 01 Control gear 01 (Product
02 Junction box Name/Code) or
03 Manual break- other equal
glass approved
(dimension
description)

nr 07 Smoke, fire and heat 01 (Product 01 generally


detectors Name/Code) or
other equal
approved
(dimensioned
description)

04 Refrigeration Installations nr 01 Unit system 01 (Product 01 fixed to a


02 Package system Name/Code) or horizontal
03 Central system other equal and surface
04 Central system approved, 02 fixed to a
(modified) (dimensioned vertical surface
description), 03 fixed to the
(capacity) tonne, plain metal
(load) rating, 04 fixed to the
associated glass
integrated or
remote
ancillaries,
controls, and
indicators or
components

264
26 MECHANICAL ENGINEERING INSTALLATIONS
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED
05 Chemical Installations nr 01 Cylindrical 01 (Product 01 fixed to a
06 Medical Suction 02 Containers Name/Code) or horizontal
Installations Special Containers other equal and surface
07 Pneumatic Tube approved, 02 fixed to a
Installations (dimensioned vertical surface
08 Refusal Disposal System description),
09 Vacuum Installations (capacity) tonne,
10 Cleanroom Installations (load) rating,
11 Other Installations associated
integrated or
remote
ancillaries,
controls, and
indicators or
components

12 Kitchen Exhaust System nr 01 Unit System 01 (Product 01 fixed to a


02 Package System Name/Code) or horizontal
other equal surface
approved 02 fixed to a
(dimensioned vertical surface
description)

13 Automatic Control nr 01 Air Conditioning 01 (Product 01 fixed to a


Installations Control System Name/Code) or horizontal
02 Lighting Control other equal surface
System approved 02 fixed to a
03 Integrated System (dimensioned vertical surface
description)

265
26 MECHANICAL ENGINEERING INSTALLATIONS
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED

02 Ducting

01 Air Conditioning m 01 Galvanised iron duct 01 Fixed to a 01 (dia.) diameter / 01 Ducting (measured overall
Installations 02 Metal duct horizontal surface (x-sectional ducting fittings, short running
02 Gas Supply System 03 Fibre glass duct 02 Fixed to a vertical dimension) length and branches).
03 Fire Protection Services 04 Polymer duct surface 02 Flexible and extensible
04 Refrigeration Installations 05 PVC duct 03 Fixed to the plain ducting profile shall be
05 Chemical Installations metal described in Level Two.
06 Medical Suction 04 Fixed to the glass 03 Curved ducting profile shall
Installations be described in Level Two.
07 Pneumatic Tube 04 Ducting fittings (heat, bolts,
Installations nut and washers) are deemed
08 Refuse Disposal to be included in the
Installations description.
09 Kitchen Exhaust System 05 BS/MS code and Class shall
10 Automatic Control be stated at Level One.
Installations

11 Duct supports nr 01 Hanger; (dimensional 01 Single run ducting 01 Technical Specifications


description) 02 Multiple runs include type, material, finish,
02 Spring hanger; ducting shape, dimensions.
(dimensioned 03 Combined
description) ducting and
03 Special hanger; pipework
(dimensioned
description)

266
26 MECHANICAL ENGINEERING INSTALLATIONS
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED

03 Pipework

01 Air Conditioning m 01 Galvanised iron pipe 01 Fixed to wall 01 (dia.) diameter / 01 Technical Specification
Installations 02 Copper pipe 02 Fixed in risers or (x-sectional includes normal size, BS/MS
02 Gas Supply System 03 PVC pipe service duct dimension) quality standard and internal
03 Fire Protection Services 04 HDPE pipe 03 Embedded in lining materials.
04 Refrigeration Installations 05 Special made pipe brickwall 02 Flexible and extensible pipe
05 Chemical Installations 06 Pre-insulated G.I. 04 Embedded in (if any) profile shall be
06 Medical Suction Pipe concrete described in Level Three.
Installations 05 Fixed to soffits of 03 The gas service pipe intake
07 Pneumatic Tube slab shall not pass through parts of
Installations 06 Fixed through the substructure which could
08 Refuse Disposal wall/floor be subject to settlement.
Installations including sleeves BS/MS code and Class shall
09 Kitchen Exhaust System 07 Laid in trench; be stated at Level One
10 Automatic Control including all
Installations necessary
excavation and
reinstatement

11 Pipe supports nr 01 Standard 01 Hanged to a 01 (dia.) diameter / 01 The length of the hanger is
02 Non-standard horizontal surface (nr) number for the varying length and
02 Hanged to a pipe works depend on the structure of the
vertical surface building must be referred to
the drawings

267
26 MECHANICAL ENGINEERING INSTALLATIONS
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED

04 Insulation to Ductwork

01 Air Conditioning m 01 Ductworks 01 Fibreglass 01 to main duct (x- 01 Technical Specification


Installations 02 Equipment’s insulation sectional includes normal thickness,
02 Gas Supply System 02 Spray insulation dimension) BS/MS quality standard, the
03 Fire Protection Services 03 Rockwool 02 to branch duct finish of material and internal
04 Refrigeration Installations insulation (x-sectional lining materials.
05 Chemical Installations 04 Expanded rubber dimension)
06 Medical Suction compound
Installations 05 Special green
07 Pneumatic Tube insulation
Installations
08 Refuse Disposal
Installations
09 Kitchen Exhaust System
10 Automatic Control
Installations

05 Insulation to Pipework and Equipment

01 Air Conditioning m 01 Fibreglass insulation 01 To (dia.) diameter 01 (Thickness) 01 Technical Specification


Installations 02 Rockwool insulation refrigerant pipe thick includes normal size, BS/MS
02 Gas Supply System 03 Expanded rubber 02 To (dia.) diameter quality standard, the finish of
03 Fire Protection Services compound suction pipe material and internal lining
04 Refrigeration Installations 04 Special green 03 To (equipment materials.
05 Chemical Installations insulation name) 02 Thickness and weight per M3
06 Medical Suction shall be stated in Level One.
Installations
07 Pneumatic Tube
Installations
08 Refuse Disposal
Installations
268
26 MECHANICAL ENGINEERING INSTALLATIONS
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED
09 Kitchen Exhaust System
10 Automatic Control
Installations

06 Ducting Accessories

01 Air Conditioning nr 01 Fire damper 01 Fixed to a 01 (x-sectional 01 Technical Specification


Installations 02 Air diffuser horizontal surface dimension) includes normal size, the
02 Gas Supply System 03 Air grille 02 Fixed to a vertical finish of material and BS/MS
03 Fire Protection Services 04 Access door surface 02 Described accordance with
04 Refrigeration Installations 05 Special equipment the details drawings and
05 Chemical Installations technical specification given.
06 Medical Suction
Installations
07 Pneumatic Tube
Installations
08 Refuse Disposal
Installations
09 Kitchen Exhaust System
10 Automatic Control
Installations

269
26 MECHANICAL ENGINEERING INSTALLATIONS
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED

07 Anti Vibration

01 Air Conditioning nr 01 Rubber mounts 01 Fixed to a 01 (x-sectional 01 BS/MS code and Class shall
Installations 02 Base spring mounts horizontal surface dimension) be stated at Level One.
02 Gas Supply System 03 Air spring mounts 02 Fixed to a vertical
03 Fire Protection Services 04 Seismic mounts surface
04 Refrigeration Installations 05 Neoprene base
05 Chemical Installations mounts
06 Medical Suction 06 Special base mounts
Installations
07 Pneumatic Tube
Installations
08 Refuse Disposal
Installations
09 Kitchen Exhaust System
10 Automatic Control
Installations

08 Sundries

01 Sundries Item 01 Air Conditioning 01 Identification and 01 plates


Installations diagram 02 discs
02 Gas Supply System 03 labels
03 Fire Protection 04 tapes
Services 05 symbols or
04 Refrigeration numbers
Installations 06 bands
05 Chemical 07 charts or
Installations diagrams
06 Medical Suction 08 other: type
Installations stated

270
26 MECHANICAL ENGINEERING INSTALLATIONS
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED
07 Pneumatic Tube
Installations
08 Refuse Disposal
Installations
09 Kitchen Exhaust
System
10 Automatic Control
Installations
02 Testing and Item 01 Air Conditioning 01 To include chemical
Commissioning Installations treatment, purging,
02 Gas Supply System sterilisation and pressure
03 System Validation Item 03 Fire Protection testing.
services
04 Operation and Item 04 Refrigeration
Maintenance Manuals Installations
05 Chemical
Installations
06 Medical Suction
Installations
07 Pneumatic Tube
Installations
08 Refuse Disposal
Installations
09 Kitchen Exhaust
System
10 Automatic Control
Installations

271
26 MECHANICAL ENGINEERING INSTALLATIONS
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED
05 Drawing preparation Item 01 Schematic drawings 01 Air Conditioning 01 Installation, coordination as
02 Floor plan drawing Installations installing and record
02 Gas Supply drawings.
System
Fire Protection
04 Services
Refrigeration
05 Installations
Chemical
Installations
06 Medical Suction
Installations
07 Pneumatic Tube
Installations
08 Refuse Disposal
Installations
09 Kitchen Exhaust
System
10 Automatic Control
Installations

272
26 MECHANICAL ENGINEERING INSTALLATIONS
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED
06 Training Item 01 Air Conditioning
Installations
02 Gas Supply System
03 Fire Protection
Services
04 Refrigeration
Installations
05 Chemical
Installations
06 Medical Suction
Installations
07 Pneumatic Tube
Installations
08 Refuse Disposal
Installations
09 Kitchen Exhaust
System
10 Automatic Control
Installations

07 Loose ancillaries Item 01 Keys, tools, spares, 01 Air Conditioning


chemical and the Installations
like. 02 Gas Supply
System
08 Post-completion services Item 01 Maintenance, 03 Fire Protection 01 See glossary of terms for the
adjustments, Services definition of completion.
servicing and the 04 Refrigeration
like. Installations
05 Chemical
Installations
06 Medical Suction
Installations

273
26 MECHANICAL ENGINEERING INSTALLATIONS
ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE Notes, comments, and glossary
MEASURED
07 Pneumatic Tube
Installations
08 Refuse Disposal
Installations
09 Kitchen Exhaust
System
10 Automatic Control
Installations

274
27 ELECTRICAL ENGINEERING INSTALLATIONS
27 ELECTRICAL ENGINEERING INSTALLATIONS

01 Primary Equipment
02 Equipment’s and fittings
03 Electrical Cable
04 Telecommunication cable
05 Final sub-circuit
06 Cable Containment
07 Lightning protection installation
08 Sundries

Information to be provided 1. Any regulations, rules, bylaws and the like


in the Specification 2. Kind and quality of material
3. Thickness of material
4. Any tests with which materials
5. Type and voltage
6. Method of fixing
7. Location

Specific information to be 1. For the main installation, need to specify type and capacity of distribution board, meter, main switch, ELCB and related
shown in the 2D drawings accessories.
or to be input into the 3D 2. For power installation, need to specify the type of switch socket, number of a gang and rating capacity.
model 3. For lighting installation, need to specify types of lighting, capacity and related accessories.
4. For electrical appliances, need to specify types and size of appliances including related accessories.
5. For conduit and fittings, need to specify the type, size and method of fixing.
6. For cables, need to specify the type, size and classification of the installation.
7. For lightning protection system, need to specify type and size of tapes, test clamps, air terminal and electrode chamber.

Specific rules of 1. For the main installation


measurement
a. Connection inside the primary equipment shall be deemed to be included.

275
27 ELECTRICAL ENGINEERING INSTALLATIONS
Works and materials 1. Classification of Works
deemed included and
a. Work together with its metalwork, supports and the like (unless associated with more than one installation) shall
general rules of
be classified as follows and given under an appropriate heading.
measurement, all of which
are to be stated in the (i.) Incoming Services
Preambles (ii.) Electrical Installations
(iii.) Clock Installations
(iv.) Telephone Installations
(v.) Alarm system Installation
(vi.) Sound Distribution System
(vii.) CCTV System Installations

2. Main installation
a. Packaged items of equipment and control gear shall be described in conjunction with the manufacturer's detailed
specification.
b. Connecting cable end or cable-tails to connector-blocks shall be deemed to be included with the item.

3. Cables containment
a. Bending, cutting, screwing, jointing and providing all conduit fitting, except those required shall be deemed to
be included with the conduit items.
b. Cutting and jointing conduits to fittings shall be deemed to be included.

276
27 ELECTRICAL ENGINEERING INSTALLATIONS
c. Cutting, jointing and providing all conduit fittings shall be deemed to be included.
d. Forming holes for conduit entry into other items of equipment shall be deemed to be included.
e. Components for earth-continuity shall be deemed to be included.
f. Cutting and jointing trunking to fittings shall be deemed to be included.
g. Cutting and jointing trays to fittings shall be deemed to be included.

4. Lightning Protection System


a. Cables for earthing shall be given in related drawings.
b. Connecting electrodes to conductors shall be deemed to be included.

Works and materials 1. Cables


deemed included and a. Determining circuits and providing draw-wires, draw-cables and the like shall be deemed to be included.
general rules of
b. Cables required to be colour coded or otherwise marked for identification shall be so described.
measurement, all of which
are to be stated in the c. Allowance for cable entering fitting, accessories, equipment and control gear shall be deemed to be included
Preambles with the items.
d. Removing and replacing existing covers, existing inspection lids and the like shall be deemed to be included.
e. Materials and heat for making the joint shall be deemed to be included.
f. Providing insulating material, jointing material, lock-nuts, bushes and the like shall be deemed to be included.
g. Connecting cable-tails to connector-blocks shall be deemed to be included.

2. Sundries
a. Plates, discs and labels for the identification of plants, cables, switches and the like shall be deemed to be
included with the item concerned.

277
27 ELECTRICAL ENGINEERING INSTALLATIONS

ITEM OR WORK TO BE
UNIT LEVEL ONE LEVEL TWO LEVEL THREE NOTES, COMMENTS &
MEASURED
GLOSSARY

01 Primary Equipment

Polyvinyl chloride (Dia.) diameter / (nr)


01 m 01 01 core in conduit 01 laid in trench
Incoming Services (PVC) cable
Steel wire armoured fixed to horizontal
02 (SWA) cable 02 surface
Crossed linked
03 polyethylene (XLPE) 03 fixed to a vertical
cable surface
04 Galvanised iron pipe

02 Electrical Installations nr 01 Main switch board 01 (Product 01 fixed to a horizontal 01 Primary equipment is
Name/Code) or other surface defined as plant or
equal approved, fixed to a vertical equipment from
(capacity) volt and 02 which a system
surface
including all originates, e.g. main
necessary switchboard,
accessories distribution board,
main control box and
02 Distribution board 01 Product Name/Code) the like.
amp circuit breaker,
(capacity) amp (nr)
MCB and (capacity)
amp (nr) RCCB (if
any)) and including
all necessary
accessories

278
27 ELECTRICAL ENGINEERING INSTALLATIONS

ITEM OR WORK TO BE NOTES, COMMENTS &


UNIT LEVEL ONE LEVEL TWO LEVEL THREE
MEASURED GLOSSARY
03 Meter 01 (Name of Service 01 generally
Provider) meter
board with (capacity)
amp cut off the fuse
and neutral link
including all
necessary
accessories

(Product fixed to horizontal


04 Generator 01 01
Name/Code) or other surface
05 Motor equal approved,
(capacity) volt and
including necessary
accessories

(Product
Name/Code) or other
equal approved,
06 Transformer 10 (capacity) volt and
including all
necessary
accessories

(Product fixed to a
07 Switch Gear 01 Name/Code) amp 01 horizontal
circuit breaker, surface
(capacity) amp (nr) fixed to a vertical
02
fuses and (nr) surface
switches and
including all
necessary
accessories

279
27 ELECTRICAL ENGINEERING INSTALLATIONS

ITEM OR WORK TO BE NOTES, COMMENTS &


UNIT LEVEL ONE LEVEL TWO LEVEL THREE
MEASURED GLOSSARY
01 (Product 01 fixed to a
nr 01 Main Board/PABX
03 Internet Installations Name/Code) or other horizontal surface
Telephone equal approved, 02 fixed to a vertical
04 02 Micro Filter
Installations (capacity) volt and surface
05 Server Installations 03 Modem/Router including necessary
accessories
06 Clock System nr 01 Main Board/ Main 01 (Product 01 fixed to horizontal
Installations Processor Name/Code) or other surface
Alarm System equal approved, 02 fixed to vertical
07 02 Recorder Panel
Installations (capacity) volt and surface
including necessary
08 Sound Distribution accessories
System
CCTV System 01 fixed to a
09 nr 01 Recording System 01 (Product
Installations horizontal surface
Name/Code) or other 02 fixed to a vertical
10 02 Visual Monitor equal approved, surface
Building Automation
System (capacity) volt and
Renewable including necessary
11 Energy/SCADA 03 Camera accessories
System

02 Equipment’s and fittings

01 Power nr 01 Switch socket 01 (nr) gang, (capacity) 01 fixed to floor 01 Terminal


02 Isolator amp and (type of 02 fixed to wall, equipment and
finish) face plate (height) mm fittings are defined
above floor finish as any item to
level which a system is
02 Lighting 01 Down light 01 (Capacity) amp and 01 fixed to horizontal distributed to, e.g.
02 High bay light all necessary surface luminaries,
03 Spot light accessories 02 fixed to vertical switches, actuators
04 Wall light surface and the like.
Compound light
05

280
27 ELECTRICAL ENGINEERING INSTALLATIONS

ITEM OR WORK TO BE NOTES, COMMENTS &


UNIT LEVEL ONE LEVEL TWO LEVEL THREE
MEASURED GLOSSARY
01 (Capacity) watt /(nr)
06 Fluorescent light
tube and all
07 Decorative light
necessary
08 Advertising light
accessories
09 KELUAR' sign lettering 02 (Capacity) watt /(nr)
Emergency lighting including (capacity)
(comprising battery, amp battery and all
10 fluorescent light and all necessary
necessary accessories
accessories)

01 (Dia.) diameter and 01 Product


all necessary Name/Code is to
03 Electrical appliances 01 Ceiling fan
accessories be described in
Level Two.
02 Wall fan
03 Industrial fan
04 Exhaust fan
05 Air extractor

03 Electrical Cable

01 (Dia.) diameter / (nr) 01 chased in brickwall 01 fixed to a 01 Generally, all cable


01 Polyvinyl chloride
m core in conduit 02 laid in suspended horizontal containment to be
02 (PVC) cable
ceiling surface measured inclusive
Steel wire armoured 03 fixed to wall of all fittings, i.e.
(SWA) cable 04 laid in trench 02 fixed to a vertical joint box,
03 Crossed linked 05 embedded in surface connectors,
polyethylene (XLPE) concrete/drywall flanges, bends,
cable tees, junctions,
reducers, spigots,
fire barriers and the
like.

281
27 ELECTRICAL ENGINEERING INSTALLATIONS

ITEM OR WORK TO BE NOTES, COMMENTS &


UNIT LEVEL ONE LEVEL TWO LEVEL THREE
MEASURED GLOSSARY

04 Telecommunication cable

(Dia.) diameter / (nr) Chased in brickwall fixed to a Generally, all cable


01 Telephone cable m 01 01 01 01
core in conduit (m/s) horizontal containment to be
surface measured inclusive
02 Laid in suspended fixed to a vertical of all fittings, i.e.
02 02
Ethernet cable ceiling surface joint box,
03 Fixed to wall connectors,
04 Laid in trench flanges, bends,
05 Embedded in tees, junctions,
concrete/dry wall reducers, spigots,
fire barriers and the
like.

05 Final sub-circuit

01 (Capacity) amp, (nr) 01 drawn into PVC Includes all


01 Final Sub-circuit for nr 01
number of points and / conduit containment not
Lighting (nr) and (nr) /(dia.) measured,
drawn into metal
diameter cable, 02 separately, junction
conduit
boxes,
01 (Capacity) volt, (nr) terminations, pots,
Final Sub-circuit number of points and / seals, glands, lugs,
02
Electrical appliances (nr) and (nr) /(dia.) connector blocks
diameter cable and shrouds.
Includes fixing
02
containment or
cables in chases,
surface or
suspended from
soffits.

282
27 ELECTRICAL ENGINEERING INSTALLATIONS

ITEM OR WORK TO BE NOTES, COMMENTS &


UNIT LEVEL ONE LEVEL TWO LEVEL THREE
MEASURED GLOSSARY

06 Cable containment

01 Conduit 01 Galvanised iron 01 Fixed to a horizontal 01 (dia.) diameter/ (x 01 Generally, all cable
m
02 Trunking 02 Metal surface cross-sectional) containment to be
03 Cable tray 03 Fibre glass 02 Fixed to a vertical measured inclusive
04 Polymer surface of all fittings, i.e.
05 PVC joint boxes,
connectors,
flanges, bends,
tees, junctions,
reducers, spigots,
fire barriers and the
like.

07 Lightning protection installation

01 Earthing electrodes nr 01 Precast 01 (x-sectional


02 PVC dimension), (nr)
number of electrode
and (depth) mm
depth of electrode

02 Air termination m 01 (Dia.) diameter 01 Includes all


copper/aluminium air connections, joints,
terminal and all test and clamps
necessary accessories
03 Conductor nr 01 (Dia.) diameter
copper/aluminium/GI
wire strip and all
necessary accessories
04 Test clamp 01 (nr) number of clamps
including bracket and
fixed to wall

283
27 ELECTRICAL ENGINEERING INSTALLATIONS

NOTES,
ITEM OR WORK TO BE
UNIT LEVEL ONE LEVEL TWO LEVEL THREE COMMENTS &
MEASURED
GLOSSARY

08 Sundries

01 Incoming Services Item 01 01 plates


Identification and
02 Electrical Installations 02 discs
diagram
03 Server Installations
03 labels
04 Clock Installations
05 Telephone
04 tapes
Installations
06 Alarm System
05 symbols or numbers
Installation
07 Sound Distribution
06 bands
System
08 CCTV System
07 charts or diagrams
Installations
08 other: type stated
09 Testing and Item 01 Incoming Services
Commissioning
02 Electrical Installations
10 System validation. Item 03 Clock Installations
04 Telephone Installations
11 Operation and Item 05 Alarm System
maintenance Installation
manuals. Sound Distribution
06
System
CCTV System
07
Installations
12 As-Built Drawing 01 Schematic drawings 01 Incoming Services
Item
preparation. 02 Floor plan drawing 02 Electrical
Installations
03 Server Installations
04 Clock Installations
05 Telephone
Installations

284
27 ELECTRICAL ENGINEERING INSTALLATIONS

NOTES,
ITEM OR WORK TO BE
UNIT LEVEL ONE LEVEL TWO LEVEL THREE COMMENTS &
MEASURED
GLOSSARY
06 Alarm System
Installation
07 Sound Distribution
System
08 CCTV System
Installations

12 Training. Item 01 Incoming Services


02 Electrical Installations
03 Server Installations
04 Clock Installations
05 Telephone Installations
Alarm System
06 Installation
Sound Distribution
07 System
08 CCTV System
Installations

13 Loose ancillaries. Item 01 Keys, tools, spares, 01 Incoming Services


chemical and the like. 02 Electrical
Installations
Post-completion Maintenance, 03 Server Installations
14 Item 01
services. adjustments, servicing 04 Clock Installations
and the like. 05 Telephone
Installations
06 Alarm System
Installation
07 Sound Distribution
System
08 CCTV System
Installations

285
28 TRANSPORTATION SYSTEMS
28 TRANSPORTATION SYSTEMS

01 Lift Installations, Escalator System and Conveyor System

Information to be provided 1. Floor and site plan detailing the layout of systems
in the Specification 2. System schematics
3. Cross-sections and elevations
4. Detail layouts for plant rooms and principal services installation areas.
5. Specific installation details for equipment and fittings.
6. Equipment schedules.
7. Type, quality and size or thickness of materials.
8. Regulations, Standard of Compliance etc.
9. Gauge, thickness or substance of the material
10. Any tests, performance test, witness test, specific test, etc
11. Capacities, running condition, operational and static load etc.
12. Mobilization of the equipment
13. Any other special requirements

Specific information to be 1. For lift, conveyor and escalator system overall dimension of the system shall be specified and location of the item
shown in the 2D drawings 2. For assembly of composite items of primary equipment or system shall be stated the dimension and location of the
or to be input into the 3D item
model 3. For, fire stopping and other associated fire protection work shall state the dimension and type of fire stopping with the
requirement of MS or BS

Specific rules of
measurement

286
28 TRANSPORTATION SYSTEMS

Works and materials 1. Classification of Works


deemed included and a. Work together with its metalwork, supports and the like (unless associated with more than one installation) shall be
general rules of classified as follows and given under an appropriate heading.
measurement, all of (i) Lift Installations
which are to be stated (ii) Escalator System
in the Preambles (iii) Conveyor System

2. Lift & Escalator


a. Lift and Escalator equipment etc.
b. Packaged items of equipment and ancillaries shall be described with the manufacturer's detailed specification
c. Size of equipment shall be given any limiting dimensions
d. Electrical connection shall be given in accordance with the Electrical Works Section
e. Platework, and supporting steelwork shall be given in accordance with Steel Works Section

3. Mobilization of Item
a. Mobilization shall include all equipment’s and related accessories for transportation of contractor's personnel,
equipment, and operating supplies to the site

4. Composite item
a. Composite item shall include lift and escalator car, sheave and motor, control panel and counterweight and guard rails

5. Fire Stopping
a. Kind and quality of materials
b. Technical specification and BOMBA approval certificate

6. Sensors and Direct Digital Control


a. Provide digital I/O Points to control major high energy usage equipment such as main switchboard, generators,
chillers, heaters, water treatment plant, tanks, cylinders, calorifiers, pumps, coolers, air-handling unit, fans, refrigerator
equipment, lift and escalator etc.
b. Special sensors and controller shall be described with the manufacturer's detailed specification
c. Size of risers required, cabling and layout
d. Electrical connection shall be given in accordance with the Electrical Works Section

287
28 TRANSPORTATION SYSTEMS

ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE NOTES, COMMENTS &
MEASURED GLOSSARY

01 Lift Installations, Escalator System and Conveyor System, Overhead Gantry/Crane

01 Primary Equipment nr 01 Passenger System 01 (Product 01 Related accessories include


02 Goods System Name/Code), associated integrated or
(dimension remote accessories, controls,
description), and indicators or components
(capacity) kg lift are deemed to be included.
capacity, (height) Cross-referenced to drawings
meter storey height to 02 and/or a full specification
a total storey height of detailing finishes.
(height) including Total storey height is defined
required car 03 from floor finish to the end of
specification and the roof beam.
associated integrated
ancillaries, controls,
and indicators or
component

02 Mobilization Item 01 Mobilization of the 01 (System Description) 01 Related accessories include


system off load and position associated integrated or
primary equipment remote accessories, controls,
and indicators or components
is deemed to be included.

01 Composite items 01 (System Description)


assembled of
composite items of
primary equipment’s

288
28 TRANSPORTATION SYSTEMS

ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE NOTES, COMMENTS &
MEASURED GLOSSARY
01 Systems 01 (System Description)
connections interface with and
connection to systems
supplied and installed
by others
03 Fire Stopping m 01 Putty 01 To vertical surface 01 (x-sectional 01 Technical Specification
02 Intumescent caulk 02 To horizontal surface dimension) include normal size and or
03 Grout areas of fixing.
04 Mortar

04 Sundries Item 01 Lift Installations 01 Identification and 01 plates


02 Escalator System diagram 02 discs
03 Conveyor System 03 labels
04 Overhead 04 tapes
Gantry/Crane 05 symbols or
numbers
06 bands
07 charts or
diagrams
08 other: type
stated

05 Testing and Item 01 Lift Installations 01 To include chemical treatment,


Commissioning 02 Escalator System purging, sterilisation and
03 Conveyor System pressure testing.
04 Overhead
Gantry/Crane
06 System validation. Item

07 Operation and Item


maintenance
manuals.

289
28 TRANSPORTATION SYSTEMS

ITEM OR WORK TO BE UNIT LEVEL ONE LEVEL TWO LEVEL THREE NOTES, COMMENTS &
MEASURED GLOSSARY
08 Drawing preparation. Item 01 Schematic 01 Lift Installations 01 Installation, co-ordination as
drawings 02 Escalator System installing and record drawings.
02 Floor plan drawing 03 Conveyor System
03 As-built drawing 04 Overhead
Gantry/Crane

09 Training. Item 01 Lift Installations


02 Escalator System
03 Conveyor System
04 Overhead
Gantry/Crane

10 Loose ancillaries. Item 01 Keys, tools, spares, 01 Lift Installations


chemical and the 02 Escalator System
like. 03 Conveyor System
04 Overhead
Gantry/Crane

11 Post-completion Item 01 Maintenance, 01 See glossary of terms for the


services. adjustments, definition of completion.
servicing and the Specify any
like. warranty/guarantee.

290
29 BUILDER’S WORK IN CONNECTION WITH MECHANICAL, ELECTRICAL AND TRANSPORTATION INSTALLATIONS
29 BUILDER'S WORK IN CONNECTION WITH MECHANICAL, ELECTRICAL AND TRANSPORTATION INSTALLATIONS

01 New Building Structure


02 Existing Building Structure

Information to be provided in the 1. Type of materials


Specification 2. Quality of materials description
3. Size or thickness of material description
4. Regulations, Standard of Compliance etc.

Specific rules of measurement


Specific information to be shown
in the 2D drawings or to be input
into the 3D model

Specific rules of measurement 1. An item shall be given for each and every services installation.
2. Example of installations are cold water services, lighting installation, power installation, lift installation.
3. In the case for large and complex projects, it may necessary to subdivide each installation into locations or levels.
4. This item means every type of general builder’s works necessary in connection with the service installation except
those items included in the specific service rules.

Works and materials deemed 1. Plant bases shall be given in accordance with Precast Concrete Works Section.
included and general rules of 2. Gratings, louvres etc. shall be given in accordance with Metalwork Section.
measurement, all of which are to 3. Platework, fuel hoppers, steel beams and supporting steelwork shall be given in accordance with Steel Works
be stated in the Preambles Section.

291
29 BUILDER’S WORK IN CONNECTION WITH MECHANICAL, ELECTRICAL AND TRANSPORTATION INSTALLATIONS

ITEM OR WORK TO BE NOTES, COMMENTS &


UNIT LEVEL ONE LEVEL TWO LEVEL THREE
MEASURED GLOSSARY
01 General builder's work Item 01 Mechanical 01 All items of the builder's
in connection with: engineering installation work shall be given in
02 Electrical services accordance with each
installation and every services
03 Transportation system installation.
02 Holes for pipes, 02 Builder's work in
mortices and sinkings Item connection with
plumbing and
mechanical services
installation shall be
group together and
given an appropriate
heading.

01 New building structure

03 Pipes and duct sleeves nr 01 Galvanised mild steel 01 Casting into Method of fixing shall be
02 Copper reinforced concrete 01 (dia.) diameter 01 described in Level Two.
/(x-sectional
03 PVC 02 Building into brick 02 Nature of the structure
dimension)
04 HDPE walls shall be described in
05 Special made thick
Level Two.
06 Pre-insulated G.I. 03 Building into block 03 Cutting holes for pipes is
07 Metal duct walls deemed to be included
08 Fibre glass duct and described in Level
09 Polymer duct Two.
04 Making good after the
installation is deemed to
include in the
description.

292
29 BUILDER’S WORK IN CONNECTION WITH MECHANICAL, ELECTRICAL AND TRANSPORTATION INSTALLATIONS

ITEM OR WORK TO BE NOTES, COMMENTS &


UNIT LEVEL ONE LEVEL TWO LEVEL THREE
MEASURED GLOSSARY
04 Support for services nr 01 Pylons 01 supporting pipework 01 (dia.) diameter / 01 Method of fixing shall be
02 Poles (x-sectional described in Level Two.
03 Wall-brackets dimension) 02 Nature of the structure
thick shall be described in
04 Pole-brackets
Level Two.
05 Pole stays
06 Ceiling brackets

05 Catenary cables m 01 Lazy wave 01 eyebolts 01 (dia.) diameter / 01 Method of existing for
02 Free Hanging 02 shackles (x-sectional eyebolts, shackles and
03 Steep Wave 03 straining screws dimension) straining screws shall be
04 U Shape thick described in Level
Three.
06 Bedding and nr 01 Grouting with cement 01 lift door jamb 01 (x-sectional
pointing/units of and sand (1:3) 02 special opening dimension)
equipment, ancillaries

02 Existing building structures

01 Cutting and pinning nr 01 01 in walls 01 for openings; 01 Nature of the structure


Size of supports
ends of support for (dia) diameter / shall be described in
description
equipment and (x-sectional Level Two.
ancillaries 02 in beams dimension) 02 System of fire-rated
shall be described in
Level Three.
03 in columns 03 Making good after the
installation and removal
of debris is deemed to
includ in the description.

293
29 BUILDER’S WORK IN CONNECTION WITH MECHANICAL, ELECTRICAL AND TRANSPORTATION INSTALLATIONS

ITEM OR WORK TO BE NOTES, COMMENTS &


UNIT LEVEL ONE LEVEL TWO LEVEL THREE
MEASURED GLOSSARY
02 Cutting and pinning nr 01 Galvanised mild steel 01 in walls 01 (x-sectional 01 Nature of the structure
ends of support for 02 in beams dimension) shall be described in
02 Copper pipe
pipes (exceeding 55mm Level Two.
nominal size) 03 PVC pipe 03 in columns 02 for openings; 02 Pipes shall be grouped
04 HDPE pipe (dia.) diameter / together.
05 Special made pipe (x-sectional 03 Pipes are measured
06 Pre-insulated G.I. Pipe dimension) overall fittings, short
running length and
branches.
04 System of fire-rated
shall be described in
Level Three.
Making good after the
installation and removal
of debris is deemed to
05
include in the
description.

03 Cutting and pinning m 01 Galvanised mild steel 01 in walls 01 (x-sectional 01 Nature of the structure
ends of support for dimension) shall be described in
02 Copper pipe
pipes not (exceeding Level Two.
55mm nominal size) 03 PVC pipe 02 in beams 02 spacing of the 02 Pipes shall be grouped
04 HDPE pipe support; (x- together.
05 Special made pipe 03 in columns sectional 03 Pipes are measured
06 Pre-insulated G.I. Pipe dimension) overall fittings, short
03 running length and
for openings; branches.
(dia.) diameter / 04 System of fire-rated
(x-sectional shall be described in
dimension) Level Three.
05 Making good after the
installation and removal
of debris is deemed to
include in the
description.

294
29 BUILDER’S WORK IN CONNECTION WITH MECHANICAL, ELECTRICAL AND TRANSPORTATION INSTALLATIONS

ITEM OR WORK TO BE NOTES, COMMENTS &


UNIT LEVEL ONE LEVEL TWO LEVEL THREE
MEASURED GLOSSARY
04 Cutting mortices and nr 01 In concrete 01 in floor slabs 01 (x-sectional 01 Nature of the structure
sinkings dimension) shall be described in
02 in walls
Level Two.
03 in beams 02 Cutting of floorboards
04 in columns and notching joists shall
be deemed included in
02 In brick walls 01 half brick thick the description.
02 one brick thick 03 System of fire-rated
shall be described in
one and a half brick
03 Level Two.
thick
(thickness Making good after the
04 04
description) thick installation and removal
of debris is deemed to
01 (x-sectional 01 generally include in the
03 In granite
dimension) description.
04 In marble
05 In ceramic tiles
06 In timber
07 In ceiling boards
In metal
08
05 Cutting chases m 01 (dia.) diameter / (x- 01 Nature of the structure
sectional dimension), shall be described in
(nr) number Level Three.

02 Chases in existing work


shall be deemed
included in the
description.
02 Making good after the
installation and removal
of debris is deemed to
include in the
description.

295
29 BUILDER’S WORK IN CONNECTION WITH MECHANICAL, ELECTRICAL AND TRANSPORTATION INSTALLATIONS

ITEM OR WORK TO BE NOTES, COMMENTS &


UNIT LEVEL ONE LEVEL TWO LEVEL THREE
MEASURED GLOSSARY
06 Lifting and replacing m 01 Existing chequered 01 (x-sectional 01 Existing floorboards
plates to floors dimension) (measured along the
route of the pipe or
02 (dia.) diameter / (x- ducting). No distinction
02 Existing floorboards sectional dimension) shall be made between
(nr) number routes parallel to or at
an angle to the
floorboards.

02 Making good after the


installation and removal
of debris is deemed to
include in the
description.

07 Boring or excavating nr 01 (mm) depth 01 Nature of filling and the


holes in the ground for treatment of surplus soil
poles and stays shall be described in
Level Three.

296