You are on page 1of 9

P1889-P1944-E.qxd 08.9.

2 8:12 PM Page 1926

Hand Valve

Series VH
Specifications

Fluid Air
Proof pressure 1.5 MPa
Max. operating VH200/300/400 1.0 MPa
pressure VH600 0.7 MPa
Ambient temperature and operating fluid temperature –5 to 60°C (No freezing)
VH600 Operating angle 90°
VH410 Lubrication Not required (Use turbine oil Class 1 ISO VG32, if lubricated.)

Option
VH210 VH310
Bottom ported VH300/400
Panel mounted VH200/300/400
Different 1(P) port location (On handle side) All models applicable ∗
∗ Note that 1(P) port of VH600 is located on handle side as standard.

Model
JIS Symbol
2 position Model Effective Mass
(A)(B) Series Port size Number of
Piping direction area
2 4 Rc positions (kg)
Body mounted Panel mounted (mm2)

3 (Closed center) VH200-02 VH210-02


1 3
4
(P)(R) VH2 1/4 3 (Exhaust center) VH201-02 7.5 0.42
VH211-02
2

Closed center 2 (Position) 1 3 VH202-02 VH212-02


(A)(B)
2 4 3 (Closed center) VH300-02/03 VH310-02/03
4 3
3 (Exhaust center) VH301-02/03 VH311-02/03 Rc 1/4:
1 3 17
(P)(R) 2 (Position) 1 2 VH302-02/03 VH312-02/03
VH3 1/4, 3/8 0.71
Exhaust center 3 (Closed center) VH320-02/03 VH330-02/03
(A)(B) Rc 3/8:
2 4 3 (Exhaust center) VH321-02/03 VH331-02/03 20
2 (Position) 4 3 VH322-02/03 VH332-02/03
12
1 3
(P)(R) 3 (Closed center) VH400-02 to 06 VH410-02 to 06 Rc 1/4:
4 3 45
3 (Exhaust center) VH401-02 to 06 VH411-02 to 06
Rc 3/8:
2 (Position) 1 2 VH402-02 to 06 VH412-02 to 06 49
VH4 1/4 to 3/4 1.28
Handle Operation Angle and Air Flow Direction
3 (Closed center) VH420-02 to 06 VH430-02 to 06 Rc 1/2:
(Refer to the figures of piping direction to the right.) 55
3 (Exhaust center) VH421-02 to 06 VH431-02 to 06
2 position 3 position Rc 3/4:
Flow Flow 2 (Position) 4 3 VH422-02 to 06 VH432-02 to 06 58
Flow Flow 12
direction direction direction N direction
2 (A) 4(B) 2 (A) 4(B) 3 (Closed center) VH600-06/10 Rc 3/4:
90° 45° 45° 2 1 185
VH6 3/4, 1 3 (Exhaust center) VH601-06/10 -
Rc 1: 9.7
4 194
2 (Position) 3 VH602-06/10

1926
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
P1889-P1944-E.qxd 08.9.2 8:12 PM Page 1927

Hand Valve Series VH

How to Order

VH 2 0 1 02
Made to Order
Nil Standard
Hand valve X116 Handle (Red)

Suffix symbol
Body size (Base size) Nil Standard
L Long handle (Applicable to VH300/400)
2 1/4 base
R 1(P) port 180° location change
3 3/8 base
∗ When specifying more than one option, indicate
4 1/2 base
symbols alphabetically.
6 1 base

Port size (Nominal size)


Piping/Mounting
Symbol Port size (Nominal size) Applicable body size
Symbol Piping Note) Mounting method 02 1/4 2, 3, 4
0 Side Body 03 3/8 3, 4
1 Side Panel mounting 04 1/2 4
2 Bottom Body 06 3/4 6
3 Bottom Panel mounting 10 1 6
Note) Only side piping is available for
VH200 and VH600 and 3(R)
port is located on the bottom.
Thread type
Function Nil Rc
0 3 position closed center F NPT
1 3 position exhaust center N G
2 2 position

Flow Characteristics
VH200 Effective area S=7.5mm2 VH300 Effective area S=20mm2 VH400 Effective area S=55mm2
Supply pressure MPa Supply pressure MPa Supply pressure MPa
1.0 1.0 1.0
1.0 1.0 1.0
0.9 0.9 0.9
Valve output pressure MPa

0.9 0.9 0.9


Valve output pressure MPa
Valve output pressure MPa

0.8 0.8 0.8 0.8


0.8 0.8
0.7 0.7 0.7
0.7 0.7 0.7
0.6 0.6 0.6 0.6 0.6
0.6
0.5 0.5 0.5 0.5 0.5
0.5
0.4 0.4 0.4 0.4 0.4
0.4
0.3 0.3 0.3 0.3 0.3 0.3
0.2 0.2 0.2 0.2 0.2 0.2
0.1 0.1 0.1 0.1 0.1 0.1

0 200 400 600 800 1000 0 1000 2000 0 2000 4000 6000

Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Flow rate (l/min (ANR))

VH600 Effective area S=194mm2


VM
Supply pressure MPa
0.7
0.7
VMG
Valve output pressure MPa

0.6

0.5
0.6
VR
0.5
0.4 0.4
VH
0.3 0.3
0.2 0.2
0.1
0.1

0 5 10 15

Flow rate (m3/min (ANR))

1927
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
P1889-P1944-E.qxd 08.9.2 8:13 PM Page 1928

Series VH

Construction
VH200 7
8 6
9
4
3
1
10
5

1 (P)

3 (R)
4 (B) 2 (A)
2

VH300/400 7 2
8 9

3
4
1 10

4 (B) 2 (A) 1 (P) 3 (R)

VH600

2 (A) 4 (B) 1 (P)


2
3 (R)

Component Parts
Material
No. Description
VH200/300/400 VH600
1 Cover Zinc die-casted Cast iron
2 Body Aluminium die-casted Cast iron
Part No. of Lock Nut
Replacement Parts for Panel Mounting
Part no. Series Part no.
Description No. Component parts Material
VH200 VH300 VH400 VH200 244010
3 Slide ring Resin VH300 24418
Maintenance
and repair kit ∗ 4 Slide ring spring Piano wire KT-VH2쏔쏔-N KT-VH3쏔쏔-N KT-VH4쏔쏔-N VH400 240258
5 O-ring NBR Note) Not applicable to the VH 600 series.
6 Handle head Zinc alloy
Handle head 7 Spring Piano wire
assembly ∗ 8 Pin Structural steel
24403A 24413A 24413A

9 Steel ball SUJ


6 Handle head Zinc alloy
7 Spring Piano wire
Handle head
assembly ∗ 8 Pin Structural steel 244036A 244125A 244125A
9 Steel ball SUJ
10 Handle —
Standard 244032 244032 244032
Handle 10 Long type — — 244127 244223
Red 244035 244035 244035
Note) Replacement parts for the VH600 series are not available.
∗ Including grease.
1928
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
P1889-P1944-E.qxd 08.9.2 8:13 PM Page 1929

Hand Valve Series VH

Dimensions: Body Mounted


( ): Long handle type
VH20쏔-02 VH30쏔-02/03

4 (B)
4 (B)
1 (P)

Max..PRESS 1.0MPa
1 (P) 3 (R)
Max..PRESS 1.0MPa

N 2
쏔62

쏔74
N 2

62
49

24

13

24

13
4

4
ZQ

ZQ
2 (A)
25

4 x ø5.5 49

2 (A)
4 x ø6.6

62

125 134 (159)


94 97 (122)
60 60
ø22

ø22
105 (109)
(90)
73

88.5

1 (P)
23
12

1 (P) 3 (R)
27
3 (R)

4 x 1/4
13.5

12 4 x 1/4, 3/8

VH32쏔-02/03
(Bottom ported)
4

2 (A)
ø4

2 A

1 (P)
3 R

1 (P) 3 (R)
1 P

4 B
4 x 1/4, 3/8
4 (B)

VM
VMG
VR
VH

1929
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
P1889-P1944-E.qxd 08.9.2 8:13 PM Page 1930

Series VH

Dimensions: Body Mounted


( ): Long handle type ( ): Long handle type
VH40-02 to 04 VH40-06

4 (B)

4 (B)
Max..PRESS 1.0MPa
Max..PRESS 1.0MPa

1 (P) 3 (R) 1 (P) 3 (R)

102

N 2
N 2
102
89

88

2 4

1 3
2 4

1 3
4

ZQ
ZQ
2 (A)

2 (A)
4 x ø6.6 4 x ø6.6

81 88
94

144 (191) 154 (191)


97 (145) 107 (145)

60 60

ø22
ø22
122 (130)

125 (132)
105.5

107.5

1 (P) 3 (R)
25
17

19
2

4 x 1/4, 3/8, 1/2 4 x 3/4

VH42-02 to 04 VH42-06
(Bottom ported) (Bottom ported)

2 (A) 2 (A)
A 2

6
ø4
R

1 (P) 3 (R) 1 (P) 3 (R)


1
P

ø86
ø54

4 B

4 (B) 4 (B) 4 x 3/4

4 x 1/4, 3/8, 1/2

1930
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
P1889-P1944-E.qxd 08.9.2 8:13 PM Page 1931

Hand Valve Series VH

Dimensions: Body Mounted

VH600-06/10

2 (A)

2
ø3
z(P)
쏔152
132

4 x ø11
4 (B)

132

≅ 300
≅ 223
M15 x 1.5
ø15

≅ 151
150
48
25

4 x Rc 3/4, 1
3 (R)

40
VM
VMG
VR
VH

1931
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
P1889-P1944-E.qxd 08.9.2 8:13 PM Page 1932

Series VH

Dimensions: Panel Mounted

( ): Long handle type


VH21쏔-02 VH31쏔-02/03

4 (B)
4 (B)

Max..PRESS 1.0MPa
3 (R)
Max..PRESS 1.0MPa

1 (P) 1 (P)

N 2
N 2
쏔62

쏔74
49

62
24

13

24

13
4

4
ZQ

ZQ
25

2 (A)

4 x ø5.5 49

2 (A)
4 x ø6.6

62

125 134 (159)


94 97 (122)
60 60
ø22

ø22
M33 x 1.5 M40 x 1.5
1.5

1.5

105 (109)
90
73

88.5
45

1 (P)

56
23
12

1 (P) 3 (R)
27
3 (R)

4 x 1/4
13.5

12 4 x 1/4, 3/8

VH33쏔-02/03
(Bottom ported)
Panel cut dimension
4

2 (A)
ø4

2 A

+0.3
2 x øA 0
0 .5
+0

øC
1 (P) 3 (R)
3 R
1 P
0.1
B

4 B
4 x 1/4, 3/8
4 (B)
Max. panel thickness D

(mm)
A B C D
VH200 3.2 40 35 3.5
VH300 3.2 51 41 6
VH400 3.2 64 51 8

1932
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
P1889-P1944-E.qxd 08.9.2 8:13 PM Page 1933

Hand Valve Series VH

Dimensions: Panel Mounted


( ): Long handle type ( ): Long handle type
VH41쏔-02 to 04 VH41쏔-06

4 (B)

4 (B)
1 (P) 3 (R) 1 (P) 3 (R)

쏔102
N 2

N 2
Max..PRESS 1.0MPa

Max..PRESS 1.0MPa
102
89

88
2 4

1 3

2 4

1 3
4

ZQ
ZQ

2 (A)
2 (A)

4 x ø6.6 4 x ø6.6

88
81
94

144 (191) 144 (191)


97 (145) 97 (145)

60 60

ø22
ø22

M50 x 1.5 M50 x 1.5

1.5
1.5

125 (132)
122 (130)
105.5

107.5
65

67
1 (P) 3 (R) 1 (P) 3 (R)
25

19
17

4 x 3/4
4 x 1/4, 3/8, 1/2

VH43쏔-02 to 04 VH43쏔-06
(Bottom ported) (Bottom ported)
2 (A) 2 (A)
A 2

6
ø4

1 (P)
R

1 (P) 3 (R) 3 (R)


1

VM
P

ø86
ø54
VMG
4 B

VR
4 (B) 4 x 3/4
4 (B)
4 x 1/4, 3/8, 1/2 VH

1933
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
P1889-P1944-E.qxd 08.9.2 8:13 PM Page 1934

Series VH
Specific Product Precautions
Be sure to read defore handling.
Refer to front matters 58 and 59 for Safety Instructions and pages 3 to 7 for 3/4/5 Port
Solenoid Valve Precautions.

Design Piping

Warning Caution
1. Not suitable for use as a selector valve or a divider 1. Ensure connection so that air is supplied to the
valve. port “1(P)” port.
The valve can malfunction due to air leakage. Air leakage may occur when the pressure is supplied from
other ports.
2. Not suitable for negative pressure.
The valve can malfunction due to air leakage. 2. Note that in the case of the option of different
“1(P)” porting position, porting indication on the
3. Do not supply air pressure from other ports than
body and flow direction by handle operation are
1(P) port.
Air leakage may occur when the pressure is supplied from reversed.
other ports.

Selection Environment

Warning Warning
1. Intermediate stop 1. When the valve is exposed to a large amount of
When stopping the cylinder piston in the middle using the dust, install a silencer into the port “3(R)”. When
3 position closed center valve, it is not possible to stop it dust enters the valve from the port “3(R)”, it may
correctly and precisely as the hydraulic equipment due to the
air compressibility. Do not use this valve because it has slight
cause air leakage.
air leakage and can not hold a stopping position. When it is
necessary to hold a stopping position, select an equipment to
prevent displacement and design the circuit.

Caution
1. Use in low temperature environments
The valve can be used at a temperature down to –5°C. Take
appropriate measures to avoid freezing of drainage, moisture,
etc.
2. Operation method
The valve must be switched to each position instantly and
securely. Stopping the handle halfway between the extreme
positions may cause malfunction.

1934
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

You might also like