Nonloadbearing concrete masonry units (Hollow Blocks, Solid Units, End Flangs)

# No. Tests Required Testing Standard

Individual
1 Comressive Strength ASTM C 140
Average

Individual
2 Density ASTM C 140
Average

Individual

3 Absorption ASTM C 140

Average

Individual

4 Dimensional Tolerance ASTM C 140

Average

5 Total Linear Drying Shrinkage ASTM C 426 Average

Loadbearing concrete masonry units (Hollow Blocks, Solid Units, End Flangs)

# No. Tests Required Testing Standard

Individual
1 Comressive Strength ASTM C 140
Average
1 Comressive Strength ASTM C 140
Average

Individual
2 Density ASTM C 140
Average

Individual

3 Absorption ASTM C 140

Average

Individual

4 Dimensional Tolerance ASTM C 140

Average

5 Total Linear Drying Shrinkage ASTM C 426 Average

Cerbstone
# No. Tests Required Testing Standard

1 Apperance SASO 1248


1 Apperance SASO 1248

2 Dimensions SASO 1248

3 Transverse Strength SASO 1248

Water absorption ratio for


4 Water Absorption SASO 1248
more

Solid concrete interlocking paving blocks


# No. Tests Required Testing Standard
Individual

1 Compressive strength ASTM C 140

Average

Individual

2 Absorption ASTM C 140

Average

Units shall have an expos


thickness shall be ≤4. The
3 Dimensional tolerance ASTM C 140 length or width of test sp
specified dimensions. Me
more than 63.2 mm from

Specimens shall not have an


4 Abrasion resistance ASTM C 418
thickness loss shall not excee
Product Specs : ASTM C 90

Test limits

the average linear shrinkage of the three units tested shall not
exceed 0.065 %

Product Specs : ASTM C 90

Test limits
the average linear shrinkage of the three units tested shall not
exceed 0.065 %

Product Specs : SASO 1248


Test limits
ter absorption ratio for precast concrete kerbs and edgings during the test shall not be
more than 3% by weight for average samples.

Product Specs : ASTM C 936

Test limits
min. 8000 psi [55 MPa]

min. 7200 psi [50 MPa]

Max 5%

Max 7%

ts shall have an exposed face area 0.065 m2 , and their overall length divided by
ckness shall be ≤4. The minimum specified thickness shall be 60mm. Measured
gth or width of test specimens shall not differ by more than 61.6 mm from
ecified dimensions. Measured thickness of test specimens shall not differ by
re than 63.2 mm from the specified dimension.

mens shall not have an average volume loss greater than 15 cm3 /50 cm2 . The average
ness loss shall not exceed 3 mm.