Bilge Water Separator and 15ppm Bilge Alarm Monitor Instruction Manual

press “MODE” key to return to PPM READING SCREEN

2.4.2.3 Equipment connection

15ppm Bilge Alarm Monitor connection to a PC will be done through a serial


non crossed wire, from output RS-232 located in lower part of monitor, to serial port of
PC. On table below a detailed configuration of wire:

DB-9 MALE DB-9 DB-9 DB-9


FEMALE MALE FEMALE

PC MONITOR

DESARROLLOS TECNICAS INDUSTRIALES DE GALICIA, SA (DETEGASA) LA CORUÑA, SPAIN Page 68 of 63


Bilge Water Separator and 15ppm Bilge Alarm Monitor Instruction Manual

Connector DB-9 Female (PC) Connector DB-9 Male (Monitor)

Pin Line Pin Line

2 RX 2 TX

3 TX 3 RX

5 GND 5 GND

DESARROLLOS TECNICAS INDUSTRIALES DE GALICIA, SA (DETEGASA) LA CORUÑA, SPAIN Page 69 of 63


Bilge Water Separator and 15ppm Bilge Alarm Monitor Instruction Manual

2.5 Data transfer

Data transfer from PC will not start until cable has been connected and monitor
has been configured into data transmission mode (See section 2.3.3.3.)

To make transference, use program “BAlarm”, previously installed on PC. Run


this program by double-clicking “BAlarm” icon.

To select serial port where monitor is connected, select “Communications-


>COMport…” from top menu. It will appear a dialogue window to select port from a
list. Once it is selected, press "OK".

To start data transfer, select “Communications->Download”. If monitor is


correctly connected and in data transmission mode, transfer should start automatically.

DESARROLLOS TECNICAS INDUSTRIALES DE GALICIA, SA (DETEGASA) LA CORUÑA, SPAIN Page 70 of 63


Bilge Water Separator and 15ppm Bilge Alarm Monitor Instruction Manual

Program will now transfer all data stored on memory card. This process can take
some minutes, depending on amount of transmitted data and other factors. It is common
that, during communication process, transmission stops for a few seconds and continues
automatically. This occurs due to failures on transmission medium and protocol used.

If an error occurs, program will finish communication and inform to user. In this
case, check connections and configuration of serial port. Check also that monitor is on
transmission mode.

If transmission ends correctly, communication window will disappear and


received data process will start. This process can take some minutes, depending on
amount of data stored on monitor memory and capacity computer.

2.5.1 Data presentation

Data is shown in two tables and a graphic.

STATE

TABLE

EVENTS
GRAPHI
TABLE
DESARROLLOS TECNICAS INDUSTRIALES DE GALICIA, SA (DETEGASA) LA CORUÑA, SPAIN Page 71 of 63