You are on page 1of 1

GENERAL NOTES

DIMENSIONS NOTED ON ARCHITECT'S DRAWINGS ARE FROM


STRUCTURAL ELEMENTS NOT FINISHES, UNLESS OTHERWISE
INDICATED
All relevant details, levels, dimensions, setting out positions are
to be checked prior to any work commencing and any
discrepancies are to be brought to the attention of the Architect.
The Architect accepts no responsibility for errors resulting from
misinterpretation of the drawings.
Bathrm All dimensions are given in millimeters unless otherwise noted.
A: 2 m2 Drawings are to read in conjunction with Engineer's drawings.
Contractor to keep full set of drawings on site.
Maid Contractor is responsible for the correct setting out of the
building on site with particular reference to boundaries and
A: 9 m2 building lines.
Contractor and Engineer to verify all levels and dimensions on
Family Living Room site and check same against Architect's drawings before
Staircase commencing work.
A: 27 m2

22G x 250
Figured dimensions to be used as preference to scaled

23R x 183
A: 17 m2
dimensions.
6 Large scale details to be used where available.
5

3
Kitchen COPYRIGHT:
2
The copyright of the literary works, artistic works and published
1 A: 12 m2 editions
UP
contained herein is vested with LEAD INNOVATIVE
ARCHITECTURE
Any adaption, distribution, sale or for hire, or any form of
reproduction of these works, in any part or in their entirety, by
WC any party other than LEAD INNOVATIVE ARCHITECTURE is an
infringement of this copyright, and LEAD INNOVATIVE
A: 2 m2 ARCHITECTURE reserves the right to claim damages from any
Bathrm party infringing this copyright, unless these rights are varied in
A: 3 m2 writing.
Store
A: 3 m2 DRAWING NOTES

Guest
A: 15 m2 Dining CLIENT ENDORSEMENT :
It is agreed that the client, by its signature to this drawing,
A: 13 m2 accepts and approves the
conceptual design and / or technical informations contained
herein.
CLIENT / CLIENT REPRESENTATIVE : DATE :

Revision History
RevID ChID Change Name Date

Foyer
A: 4 m2
WC Main Living Room
A: 3 m 2 A: 33 m2

Project Status:
FOR CONSTRUCTION

LEAD INNOVATIVE ARCHITECTURE


5D KANTA ROAD, KADUNA, NIGERIA RC 1483607
T E L : +2 3 4 7 0 3 8 0 5 1 1 0 9 , + 2 3 4 7 0 3 7 8 5 4 9 5 8
E M A I L : leadinnovativearchitecture@ gmail.c o m

Project:
PROPOSED RESIDENTIAL DEVELOPMENT
FOR MR. MUHAMMAD NASIDI
LOCATION; RIJIYAR ZAKI, UNGOGO L.G.A,
KANO STATE

Layout ID Designed by Revision


A.01.6 A. Tanimu (Arc) 00
SCALE: Checked by DATE
1:100 Arc. A. Zakari APRIL, 2021
#LayID
B

0. GROUND FLOOR 1:100


GSPublisherVersion 0.1.100.100