You are on page 1of 1

1 2 3 4 5 6 7 8 9 10

N GENERAL NOTES :
1. ALL DIMENSIONS ARE IN FEET & INCHES, UNLESS OTHERWISE
44'-712" SPECIFIED.
1'-4" 2. DRAWING SHOULD NOT BE SCALED, FOLLOW FIGURED DIMENSIONS.
10'-9" 10'-9" 5'-412" 6'-112" 11'-712" 6'-312" 3. ANY DISCREPANCY IN DRAWING SHALL BE BRING TO NOTICE OF
SITE BOUNDARY LINE STRUCTURAL CONSULTANT BEFORE EXECUTION OF WORK.
F 1'-4" F
STIRRUPS @ 4" C/C 4. THIS DRAWING SHOULD BE READ ALONG WITH THE RELEVANT
1'-412" STIRRUPS @ 6" C/C ARCHITECTURAL DRAWING.

8 412" 412" 412" 412" 1'-6" 5. IF THERE IS ANY REVISION IN DRAWING, FURTHER CONSTRUCTION
SHALL BE EXECUTED AS PER THE LATEST REVISED DRAWING, ON THE
C2 C1 C1 C2 FLOOR LV.
412"
ISSUE OF LATEST REVISION.
712" 6" 6" 6. GRADE OF CONCRETE SHALL BE M20.GRADE OF STEEL SHALL BE Fe500
7. CLEAR COVER FOR

9'-6"
FOOTING :2"(50mm)
412" 412" GROUND BEAM :1 1/2"(40mm)
7 COLUMN :1 1/2"(40mm)
412" 412" 412" 6" 6" BEAM :1"(25mm)
1
42" 412" 412" 1'-3" SLAB :3/4"(20mm)
6 C1 C1

2'-0"
C1 C1 C2 8. LAP LENGTH OF BARS : 50Ø, AT COLUMN LAPPING PROVIDE 4"
SPACING OF TIES, NO LAPPING ALLOWED AT BEAM-COLUMN JOINT.
9. DEVELOPMENT LENGTH (Ld) FOR REINFORCEMENT BARS
IN COMPRESSION : 40Ø

10'-9"
IN TENSION : 50Ø
E 10. IN CASE OF BEAM REINFORCEMENT, NO LAPPING SHALL BE ALLOWED E
IN FOLLOWING PLACES
6" 6" (a) TOP ROD NEAR COLUMN, L/4 ON EITHER SIDES OF COLUMN
5 412" 412" (b) TOP ROD OF CANTILEVER BEAM ALONG THE LENGTH AND

LAPPING ZONE

L
C2 C2 ALSO DEVELOPMENT LENGTH, BEYOND COLUMN
412" 412" 412"

4'-9"
(c) BOTTOM ROD AT MID SPAN OF BEAM
11. REMOVAL OF SHUTTERING / FORM WORK
4 412" 412" 412" (a) COLUMN : 24 HOURS

53'-9"
C1 C1 C1 (b) BEAM SIDES : 24 HOURS
(c) BEAM BOTTOM : LESS THAN 20' SPAN : 14 DAYS

6'
6" 6" : MORE THAN 20' SPAN : 28 DAYS
412" 412"
(d) SLAB : LESS THAN 20'SPAN : 14 DAYS
3 C1 C2
: MORE THAN 20'SPAN : 28 DAYS
HOWEVER 7 DAYS STRENGTH OF CONCRETE SHOULD BE 65% OF THE
TARGET STRENGTH, TO REMOVE FORM WORK.
12. THIS BUILDING IS DESIGNED FORGROUND +1 FLOORS

10'-9"
FLOOR LV.

2'-0"
D D
412" 412" 412" 6" 6"
2 412" 412" 412" 412" 412"
C1 C1 C1 C1 C2 LEGENDS :

10'-9"
412" 412" 412" 6" 6" Typical L/S of Column
1 41" 1
42" 1
42" 412" 412"
C2 2 C2 C2 C2 C2
2'-11"

1'-9"

2'-1"

C A B C D E F C

NOTE:
CENTRE LINE AND COLUMN LAYOUT - Larger dia bar
- Smaller dia bar

SCHEDULE OF COLUMNS
REV NO Date REVISION REMARKS
9" 9"
FOUNDATION TO ROOF LVL
COLUMN
REMARKS
TYPE CLIENT TDD DESIGNERS &
SIZE REINFORCEMENT DETAILS RINGS
1'

1'

B CONSTRUCTIONS B
C1 9"x 12" 4Y16 A Y8@6" -
C2 9"x 12" 6Y12 B Y8@6" - CENTER LINE, COLUMN LAYOUT &
COLUMN C1 DETAILS COLUMN C2 DETAILS DETAIL REINFORCEMENT DETAILS

Er.Y.BOOPATHI M.E(Struct), M.I.S.T.E,


LICENSED STRUCTURAL ENGINEER-GRADE-1
STRUCTURAL
CONSULTANT
PYRAMID STRUCTURAL CONSULTANT
Contact No : +91 9597691155
Mail id :pyramidstrconsultant@gmail.com

Scale 1:150
DRAWN CHECKED APPR3VED
A Date 15-08-2022 A

BD KR YB Paper A3
Size
Rev.no R0
DRAWING NO:- YB22047-ST01
Sheet.no (01 OF 01)

1 2 3 4 5 6 7 8 9 10