FROM SEC S/S

13.8kV, 3PH, 3W, 60Hz


X/R = 12, 500MVA

Zpu = U 3ɸ
F1 0.0166 +
j0.1993

Zpu = TR-01
F2 0.4243 +
j2.9699

Zpu = C1
F3 0.1274 +
j0.2638

Zpu = C2 Zpu = C3
34.3000 + 2.8693 +
F4 j9.8800 F5 j2.7111

Zpu = M1 Zpu = M2
96.4699 + 17.8462 +
j277.8333 j119.4982
FAULT IMPEDANCE (POSITIVE/NEGATIVE SEQUENCE) FOR F1

F1

F1

F1
FAULT IMPEDANCE (POSITIVE/NEGATIVE SEQUENCE) FOR F2

F2

F2

F2
FAULT IMPEDANCE (ZERO SEQUENCE) (Z0)
Fault No. R(0) P.U. jX(0) P.U.

F1 0.0166 0.1993

F2 0.4243 2.9699
F3 0.5517 3.2337 (Zpu = TR-01) + (Zpu = C1)

F4 34.8517 13.1137 (Zpu = TR-01) + (Zpu = C1) + (Zpu = C2)

F5 3.421 5.9448 (Zpu = TR-01) + (Zpu = C1) + (Zpu = C3)

FAULT IMPEDANCE (POSITIVE/NEGATIVE


SEQUENCE) (Z1) / (Z2)
Fault No. R(0) P.U. jX(0) P.U.
F1 0.0166 0.1989
F2 0.4366 3.0593
F3 0.5566 3.3035
F4 30.8831 13.3192
F5 3.1493 5.8543