AC MUSH WINDING R

B
DIRECTION OF ROTATION OF GENERATOR
WINDING DIAGRAM
35
33 8
31 6
29 4
2

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36
2
29 4
31 6
33 8
35

SR FB SY SB FR FY

Y -Connection Delta - Connection

SR

CALCULATIONS SR FB
36
Slots per pole per phase, spp = (4*3) =3
Coil Span = Pole Pitch = 36
4 =9 FR

1 Pole Pitch => 180o (electrical) => 9 slots FB

Slot angle = 180 o FY


9 = 20 (electrical)
FR SB

Phase difference in phase sequence = 120o => 6 slots SB


SY FY
SY

WINDING TABLE (RYB SEQUENCE)


R : 1 2 3, 10 11 12, 19 20 21, 28 29 30 AC MUSH WINDING
Y : 7 8 9, 16 17 18, 25 26 27, 34 35 36
KIRAN P
B : 13 14 15, 22 23 24, 31 32 33, 4 5 6
S5 EEE - A B180894EE SHEET NO. 3
29 - 01 - 2021
ALL DIMENSIONS ARE IN mm