What is CUI – Corrosion under

insulation on Cooling tower


CUI Locations Guideline in Vertical Vessel; 

The potential area for Corrosion Under Insulation (CUI) is the area where
water can be trapped in the insulation or fireproofing. For the vertical
vessel, there is a risk point as in the picture.

Critical Factors

a) It affects externally insulated piping and equipment and those that are in
intermittent service or operate between:
1) 10°F (–12°C) and 350°F (175°C) for carbon and low alloy steels,
2) 140ºF (60°C) and 400ºF (205°C) for austenitic stainless steels and
duplex stainless steels b) Corrosion rates increase with increasing metal
temperature up to the point where the water
evaporates quickly. For insulated components, corrosion becomes more
severe at metal temperatures between the boiling point 212°F (100°C) and
350°F (121°C), where water is less likely
to vaporize and insulation stays wet longer.
c) The design of the insulation system, insulation type, temperature, and
environment are critical factors.
d) Poor design and/or installations that allow water to become trapped will
increase CUI.
e) Insulating materials that hold moisture (wick) can be more of a problem.
f) Cyclic thermal operation or intermittent service can increase corrosion.
g) Equipment that operates below the water dewpoint tends to condense
water on the metal surface
thus providing a wet environment and increasing the risk of corrosion.
h) Damage is aggravated by contaminants that may be leached out of the
insulation, such as chlorides.
i) Plants located in areas with high annual rainfall or warmer, marine
locations are more prone to CUI than plants located in cooler, drier, mid-
continent locations.
j) Environments that provide airborne contaminants such as chlorides
(marine environments, cooling tower drift) or SO2 (stack emissions) can
accelerate corrosion.

Concerned Areas of CUI and Atmospheric Corrosion – Cooling Tower; 

The main factor that causes Corrosion Under Insulation (CUI) and


Atmospheric Corrosion is ” water and moisture. ” Therefore, the area that
gets sprayed from the cooling tower and nearby the cooling tower is more
likely to have CUI and Atmospheric Corrosion stronger than other areas
Likely Location of CUI for Tower – Instrument Connections
(Deadlegs); 

According to API RP 583, Carbon steel piping with temperatures above


175 C will not cause Corrosion Under Insulation (CUI) for the Tower with
Operating Temperature higher than 175 C, but there are pipes connecting
from the Tower to the Instrument that has a  Deadleg, the temperature will
drop lower due to lack of Flow and heat loss indefinitely Therefore, there
is a chance that CUI will exist.
Corrosion Under Insulation (CUI ) – Tower with Cold Insulation;

Continuous with the CUI in the Shutdown Inspection & Maintenance of


the Column or Tower covered with Cold Insulation:

1) Even if it is equipped with Cold Insulation, CUI will occur if the


operating temperature range CUI Range (the 12  C to 175 C for Carbon
steel according to API RP 583).

2) Temperature (Metal Temperature) affects directly the severity of


the CUI. The temperature between 77 – 110 C will cause the most
severe CUI and the intensity will decrease when the temperature
is lower, which can be seen and compare that the bottom versus the
top of the Tower.
Relate topic:

What is Cooling tower in refinery plant

Typical location of CUI corrosion in piping system