You are on page 1of 10

INTERACTIVE SCHEMATIC

Bookmarks X
*This document is best viewed at a
Options
screen resolution of 1024 X 768.
Features
Cover Page
To set your screen resolution do the following:
Tables RIGHT CLICK on the DESKTOP.
Component Select PROPERTIES.
Connector
CLICK the SETTINGS TAB.
Schematic
Machine Views
MOVE THE SLIDER under SCREEN RESOLUTION
Chassis View until it shows 1024 X 768.
Cab View CLICK OK to apply the resolution.
Engine View
*Due to different monitor sizes and PDF reader preferences
The Bookmarks panel will allow you to there may be some variance in linked schematic locations
quickly navigate to points of interest.

Click here to save a copy of


EC-C2 E-C60 this interactive schematic
EC-C3
to your desktop
E-C61

VIEW ALL CALLOUTS

EC-C1
When only one callout is showing on a
machine view, clicking on this button will
Click on any text that is BLUE and make all of the callouts visible. This
underlined. These are hyperlinks button is located in the top right corner
that can be used to navigate the of every machine view page.
schematic and machine views.

ELECTRICAL SYMBOLS BASIC HYDRAULIC


HOTKEYS (Keyboard Shortcuts) COMPONENT SYMBOLS
T

Pressure Temperature Level Flow


Pump

FUNCTION KEYS
Switch Switch Switch Switch Circuit Breaker
or Motor Variability

Click here to view the


Zoom In “CTRL” / “+” Schematic Symbols
Fluid
Conditioner
Spring
(Adjustable)

Zoom Out “CTRL” / “-” and Definitions page

Fit to Page “CTRL” / “0” (zero)


Hand Tool “SPACEBAR” (hold down)
Find “CTRL” / “F”
Search “CTRL” / “SHIFT” / “F”
SCHEMATIC SYMBOLS AND DEFINITIONS

VALVES INTERNAL PASSAGEWAYS PUMPS BASIC HYDRAULIC


ENVELOPES FLOW IN ONE
DIRECTION
FLOW ALLOWED IN
EITHER DIRECTION
PARALLEL
FLOW
CROSS
FLOW
FIXED DISPLACEMENT
COMPONENT SYMBOLS

One Position Two Position Three Position Unidirectional Bidirectional Pump


Infinite Two Three Variability
Positioning Position Position or Motor
PORTS VARIABLE DISPLACEMENT
NON- COMPENSATED

CYLINDERS Fluid Spring


(Adjustable)
Two-way Three-Way Four-Way Conditioner
Unidirectional Bidirectional
CONTROL
AB AB
Single Acting Double Acting
MOTORS Pressure
FIXED DISPLACEMENT Spring
P T P T Compensation
Normal Position Shifted Position Infinite Position

CHECK
Control
ACCUMULATORS Unidirectional Bidirectional
Valves
Line Restriction
(Variable)
VARIABLE DISPLACEMENT
Basic Spring Shuttle NON- COMPENSATED
Pilot
Symbol Loaded Line Restriction
Controlled Spring Loaded Gas Charged Restriction
(Fixed)

Unidirectional Bidirectional

MAIN AUX.
Line Restriction
PILOT CONTROL 2-Section
RELEASED PRESSURE ROTATING SHAFTS Variable and Pressure
Compensated
Pump

Unidirectional Bidirectional
External Return Internal Return
Attachment Pump: Variable and
REMOTE SUPPLY PRESSURE Pressure Compensated

Internal Hydraulic Pneumatic


Simplified Complete Supply Pressure Energy Triangles

COMBINATION CONTROLS
LINES MEASUREMENT

Solenoid Solenoid Solenoid Solenoid and Servo Thermal Detent Crossing Joining
or Manual and Pilot Pilot or Manual Pressure Temperature Flow

MANUAL CONTROL FLUID STORAGE RESERVOIRS

Push-pull Lever Manual Shutoff General Manual Push Button Pedal Spring Vented Pressurized Return Above Fluid Level Return Below Fluid Level

HYDRAULIC SYMBOLS - ELECTRICAL ELECTRICAL SYMBOLS


G
M T

Pressure Temperature Level Flow


Transducer Transducer Generator Electric Pressure Pressure Switch Temperature Electrical
Switch Switch Switch Switch Circuit Breaker
(Fluid) (Gas / Air) Motor Switch (Adjustable) Switch Wire

BASIC ELECTRICAL COMPONENT SYMBOLS HARNESS AND WIRE SYMBOLS


Wire, Cable, or Harness Assembly Identification:
Fuse: A component in an electrical circuit that will open the circuit if too much current flows through it. Includes Harness Identification Letters and Harness
Connector Serialization Codes (see sample).

Switch (Normally Open): A switch that will close at a specified point (temp, press, etc.). The circle indicates
that the component has screw terminals and a wire can be disconnected from it.
AG-C4 L-C12
111-7898 3E-5179
Switch (Normally Closed): A switch that will open at a specified point (temp, press, etc.).
No circle indicates that the wire cannot be disconnected from the component.
Part Number: for 1
Connector Plug
2
Ground (Wired): This indicates that the component is connected to a grounded wire.
The grounded wire is fastened to the machine. Receptacle
Plug
Pin or Socket Number
Ground (Case): This indicates that the component does not have a wire connected to ground. Harness Identification Letter(s): (A, B, C, AA, AB, AC, ...)
It is grounded by being fastened to the machine.
Harness Connector Serialization Code: The "C" stands for
"Connector" and the number indicates which connector in the
Reed Switch: A switch whose contacts are controlled by a magnet. A magnet closes the contacts of
harness (C1, C2, C3, ...)
a normally open reed switch; it opens the contacts of a normally closed reed switch.
L-C12
3E-5179
Sender: A component that is used with a temperature or pressure gauge.
The sender measures the temperature or pressure. 5A
T Its resistance changes to give an indication to the gauge of the temperature or pressure. Component
Fuse (5 Amps) 9X-1123 Part Number
Relay (Magnetic Switch): A relay is an electrical component that is activated by electricity.
It has a coil that makes an electromagnet when current flows through it. 325-AG135 PK-14
Harness identification code:
The electromagnet can open or close the switch part of the relay. Wire Gauge*
This example indicates wire group 325,
wire 135 in harness "AG". Wire Color
Solenoid: A solenoid is an electrical component that is activated by electricity. *Wire gauge is shown in AWG (American Wire Gauge)
It has a coil that makes an electromagnet when current flows through it. but could also be shown in metric denoted with mm
The electromagnet can open or close a valve or move a piece of metal that can do work. Deutsch connector: Typical representation
1
of a Deutsch connector. The plug contains all
Magnetic Latch Solenoid: An electrical component that is activated by electricity and held latched by a 2 sockets and the receptacle contains all pins.
permanent magnet. It has two coils (latch and unlatch) that make electromagnet Sure-Seal connector: Typical representation
when current flows through them. It also has an internal switch that places 1
of a Sure-Seal connector. The plug and receptacle
the latch coil circuit open at the time the coil latches. 2 contain both pins and sockets.
UENR8161-02
August 2019

336 and 336 GC Excavator


Hydraulic System - Attachment
TPK1-UP
GMJ1-UP
DKS1-UP
YBN1-UP
HDF1-UP
FGW1-UP
EBJ1-UP
FEL1-UP
GDY1-UP
JFW1-UP
TMK1-UP
WDN1-UP
DWL1-UP
JHD1-UP
WFF1-UP
SZT1-UP
TYH1-UP

Medium Pressure

© 2019 Caterpillar. All Rights Reserved. CAT, CATERPILLAR, LET’S DO THE WORK, their respective logos, “Caterpillar Yellow,” the “Power Edge”
and Cat “Modern Hex” trade dress, as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission.
COMPONENT LOCATION

Schematic Machine
Description
Location Location
Accumulator Gp - Hydraulic (Uncharged) D-11 1
Accumulator Gp - Hydraulic (Uncharged) I-10 2
Cylinder Gp - Boom J-9 3
Cylinder Gp - Bucket J-7 4
Cylinder Gp - Stick J-6 5
Filter Gp - Oil (Drain) A-7 6
Filter Gp - Oil (Hydraulic Return) A-8 7
Motor Gp - Piston (Fan, Suction) C-2 8
Motor Gp - Swing C-9 9
Motor Gp - Travel (LH) C-14 10
Motor Gp - Travel (RH) C-12 11
Pump Gp - Hydraulic (Fan) C-3 12
Pump Gp - Main Hydraulic C-6 13
Sensor Gp - Pressure (Boom Cylinder Head) I-8 14
Sensor Gp - Pressure (Bucket Cylinder Head) I-6 15
Sensor Gp - Pressure (Bucket Cylinder Rod) D-5 16
Sensor Gp - Pressure (Drive Pump) D-7 17
Sensor Gp - Pressure (Idler Pump) D-7 18
Sensor Gp - Pressure (Stick Cylinder Head) I-7 19
Sensor Gp - Pressure (Stick Cylinder Rod) D-10 20
Swivel Gp A-12 21
Valve Gp - Check (Return) I-11 22
Valve Gp - Check (Swing) C-10 29
Valve Gp - Check (Travel Pilot) D-11 23
Valve Gp - Main Control H-12 24
Valve Gp - Solenoid (Heavy Lift) H-4 25
Attachment: Medium Pressure
Pump Gp - Gear B-5 26
Valve Gp - Control (Bank 2) J-2 27
Valve Gp - Solenoid (Medium pressure) F-14 28
TAP LOCATION

Tap Schematic
Description
Number Location
AA Pilot Pressure (Control Valve) E-11
BB Pilot Pressure (Main Pump) C-4
CC Case Drain Pressure B-4
DD Case Drain Pressure ( Pump Gp - Fan) B-3
EE Att Valve 4 Extend Pressure G-14
FF Att Valve 4 Retract Pressure G-13
GG Medium Pressure H-1
14 13 12 11 10 9 8 7 6 5 4 3 2 1

(3) BOOM CYLINDER (27) VALVE GP - BANK 2


518-6326 (5) STICK CYLINDER
(MEDIUM PRESSURE)
(4) BUCKET CYLINDER 310-0165
521-0631 521-0639
J T2 J

BR2

<EXT> <RET>
Pa1 Pb1
(14) SENSOR GP - PRESSURE AR2
BOOM CYLINDER HEAD
344-7392
BR3 AR3
<RET> B1
(22) VALVE GP AL3 BL3
CHECK (RETURN)
I 490-3958 I
CV-T 2 SPEED SWG (15) SENSOR GP - PRESSURE <EXT> A1
FAN-T TRAVEL PRKG BK (2) ACCUMULATOR GP BUCKET CYL HEAD
D CONTROL CONTROL HYDRAULIC (UNCHARGED) 344-7392
(19) SENSOR GP - PRESSURE
C 352-6990 STICK CYL HEAD
HPi 344-7392
P
AL3 AL2 AL1 AR1 AR2 AR3 MPV-P
HPi PLS
(25) VALVE GP
Pi5 SG Pi4 PAC
SOLENOID (HEAVY LIFT) T1 PPS
B 524-0912 MPV-T GG
6 7 24 A
11 13 18 23 16 12
21 CV-Dr

H BPi Dr1 H
(24) VALVE GP - MAIN CONTROL P T
STD : 512-2722
HEAVY LIFT : 504-1792
MU

Dr2 Pi2 A AL3 AL2 AL1 SHS AR1 AR2 AR3 MU Pi3 Dr3
T <UP> <IN> <OUT> <L> <BKWD> <BKWD> <CLOSE> BKHS <DOWN> <UP> <OUT>

Dr4
56 FAN PUMP SOLENOID
ATTACHMENT VALVE #4 RETRACT
38
Pi7

BUCKET
PRESSURE SOLENOID

BOOM(1)
TRAVEL(R)
Pi6

SWING

STICK(2)
STR-TRAVEL
BOOM(2)
Pa1 Pb1 ATTACHMENT VALVE #4 EXTEND

TRAVEL(L)
37

STICK(1)
G PRESSURE SOLENOID G
EE FF Dr6 24 STRAIGHT TRAVEL SOLENOID
23 RIGHT TRAVEL BACKWARD SOLENOID
A2 B2 A1 B1
22 RIGHT TRAVEL FORWARD SOLENOID
<EXT> <RET> 21 LEFT TRAVEL BACKWARD SOLENOID
37 38 20 LEFT TRAVEL FORWARD SOLENOID
19 SWING RIGHT SOLENOID
P 18 SWING LEFT SOLENOID
17 BUCKET CYLINDER RETRACT SOLENOID
16 BUCKET CYLINDER EXTEND SOLENOID
15 PUMP TO STICK HEAD END SOLENOID
T 14 STICK CYLINDER EXTEND SOLENOID
SWG PRI

STK UNL

F F
13 STICK CYLINDER RETRACT SOLENOID
(28) VALVE GP - SOL 12 BOOM CYLINDER RETRACT SOLENOID
MEDIUM PRESSURE 11 PUMP TO BOOM HEAD END SOLENOID
259-7430
Dr7 10 BOOM CYLINDER EXTEND SOLENOID
9 HYDRAULIC LOCK SOLENOID
SRS <OUT> <IN> <R> <FWD> P2S P1S <FWD> BR1 <OPEN> BR2 BKRS <UP> <DOWN> BR3 <IN>
8 SWING PRIORITY SOLENOID
Pi1 BL3 BL2 BL1 P2 P1 Dr5 7 SWING BRAKE SOLENOID
6 TRAVEL SPEED SOLENOID
AA 5 STICK UNLOAD SOLENOID
2 MAIN HYDRAULIC PUMP #2 SOLENOID
1 MAIN HYDRAULIC PUMP #1 SOLENOID
E P2 P1 IDENT ELEC DEVICE NAME E

8 5 9 14 19 20 22 17 10 15

Pi8 SPi bST


(23) VALVE GP - CHECK
(TRAVEL PILOT)
6E-4701 BL3 BL2 BL1 bST BR1 BR2 BR3

HYDRAULIC CIRCUIT COLOR DESCRIPTIONS


(18) SENSOR GP - PRESSURE (17) SENSOR GP - PRESSURE (16) SENSOR GP - PRESSURE PILOT CIRCUIT
(IDLER PUMP) (DRIVE PUMP) BUCKET CYL ROD
PUMP 1 OUTPUT
(20) SENSOR GP - STICK CYL HEAVY LIFT CONTROL CIRCUIT
Psv 344-7392 344-7392 344-7392 TRAVEL LEFT CONTROL CIRCUIT
ROD END PRESSURE FAN CONTROL CIRCUIT
(1) ACCUMULATOR GP 344-7392
D HYDRAULIC (UNCHARGED)
SUPPLY LINE
STICK CONTROL CIRCUIT D
SWING CONTROL CIRCUIT
351-0320 DRAIN / RETURN LINE
SWING BRAKE CIRCUIT
PUMP 2 OUTPUT
TRAVEL SPEED CONTROL CIRUIT
BUCKET CONTROL CIRCUIT

(12) PUMP GP - HYDRAULIC TRAVEL RIGHT CONTROL CIRCUIT


BOOM CONTROL CIRCUIT
(FAN GROUP) MEDIUM PRESSURE CONTROL CIRCUIT

(13) PUMP GP STD : 524-0924


SWG MAIN HYDRAULIC GC : 524-0925
STD : 550-4341 P1 P2 Psv
PRKG BK
CONTROL GC : 550-4342 BB
(10) MOTOR GP - TRAVEL (LH) (11) MOTOR GP - TRAVEL (RH) (29) VALVE GP - CHECK
511-0315 511-0315 (SWING) a1 A1 ph1 ph2 A2 a2 FAN-T FAN-P
563-4442 (8) MOTOR GP - PISTON (FAN, SUCTION)
TRAVEL MOTOR (LEFT) TRAVEL MOTOR (RIGHT) STD : 505-5180
A B GC : 505-5179
C SWING MOTOR C
1 2 56
Pp3 Pp3 FAN-Dr PG
(9) MOTOR GP - SWING
STD : 505-0531
SWG-Dr FAN-P
DB GC : 505-7029
a5 FAN-Dr
a4 L
B L1
MU
M
T1 DRAIN
T1 PA PB
T2 FILTER LINE PATTERNS
T2
Pressure Line
AG BG BG AG Pilot / Load Sensing Pressure

B Dr
Drain / Return Lines B
Air Line
B1 ax S L2 L
Component Group
CC CALLOUTS
A B B A MPV-P DD
d P YY Taps (Pressure, Sampling, Sensor - by letter)
CV-Dr
A C (26) PUMP GP - GEAR DL DL D Connectors (By letter)

CV-T bST (6) FILTER GP - OIL 493-3206 Callout Number


(52) VALVE GP - CONTROL
Component

D
(Machine Location from Name

B (DRAIN)
Component LocationsTable)
138-1234 Part Number

AL1 BR1 491-6075


B' D'
A FA Dr FB B
BL1 AR1
A' C' Do not operate or work on this product unless you have
read and understood the instruction and warnings in the
d' P' relevant Operation and Maintenance Manuals and
relevant service literature. Failure to follow the instruc-
SWG-Dr (21) SWIVEL GP tions or heed the warnings could result in injury or

A 490-3995 death. Proper care is your responsibility.


A
2 SPEED
DRAIN BL2 AL2 THIS SCHEMATIC IS FOR THE 336, 336 GC AND 340 EXCAVATOR HYDRAULIC SYSTEM
TRAVEL
FILTER (7) FILTER GP - OIL ATTACHMENT: MEDIUM PRESSURE
CONTROL
(HYDRAULIC RETURN) MEDIA NUMBER: UENR8161-02
504-9687 SCHEMATIC PART NUMBER: 504-1801, CHANGE: 02, VERSION: HE
Components are shown installed on a fully operable machine with the key and engine off.
Refer to the appropriate Service Manual for Troubleshooting, Specifications and Systems Operations.
Refer to the Parts Manual using a specific serial number prefix in SIS before ordering parts from this schematic.

14 13 12 11 10 9 8 7 6 5 4 3 2 1
MACHINE - TOP RIGHT SIDE VIEW
VIEW ALL CALLOUTS

5
14

21

28 FF GG 27 29 EE 9
VIEW OF AREA “A”
(ROTATED FOR CLARITY)
4

3
26

A
10

11
MAIN CONTROL VALVE - FRONT
VIEW ALL CALLOUTS

15 AA

17
18

20
16

23
MAIN CONTROL VALVE - REAR
VIEW ALL CALLOUTS

25

2
19

24
22

1
PUMP GROUP - RIGHT SIDE VIEW
VIEW ALL CALLOUTS

13
7
DD

12

BB

6
CC

You might also like