PHILIPPINE CERTIFIED LIFTS AND

CONVEYANCES SPECIALIST, INC.


Date : August 27, 2022
Time : 01:00 to 5:00 pm
Hyundai Company History

Hyundai Elevator Co., Ltd. established


1984 Technical License Agreement with Westinghouse USA

1985 R&D Center was established

1991 ISO 9001 Certification by DNV (Det Norske Veritas)

1993 Established Hyundai Elevator Manufacturing Company in China

1997 ISO 14001 Environmental Certification by DNV

1999 Launched Korea’s First Machine-Room-Less Elevator

2001 CE Mark Certification for Elevators and Escalators

2009 Completion of the World’s tallest Elevator Test Tower (205 m)

2014 Established Hyundai Elevator Manufacturing Company in Brazil

2015 Installed Korea’s First Double-deck Elevators (LG U+ HQ)

2017 Won Gold Price iF Design for the First time in the Elevator Industry
Hyundai Asan Tower / R&D Center

“One of world’s tallest elevator test tower”

Total
Height 205m

Completion Apr. 2009

.
Passenger 18m/s 1 Unit
Elevator .
Specification Passenger 10m/s 3 Units
(Double Deck 1Unit)
.
Observation 7m/s 1 Unit
.
Passenger 2m/s 2 Units
.
Shuttle 1m/s 1 Unit
.
Freight 1.5m/s 1 Unit

Total 9 units
■ Ultra-high speed /Double deck elevator is under operation
SERVICES

INSTALLATIO MODERNIZATIO SERVICIN MAINTENANC


N N G E

WE AIM TO PROVIDE A FULL RANGE OF SERVICES TO FULLY ADDRESS CLIENT


NEEDS DURING ANY PART OF THE PROCESS, STARTING FROM RAPID
INSTALLATION TO 24/7, ON-CALL, AFTER SALES SERVICE.
REFERENCES & MEMBERSHIP
• Types of Elevator (Electric Traction & Direct Plunger Hydraulic )

• Hydraulic Elevator
- Up to 21.0 meters Bldg height
only or six (6) Storeys High
- Speed of 0.1 to 1.0 meter /
second
- Installation of Elevator
- 2 Floors = 26 days; 19 days
with Sunday and 3 hours
overtime everyday
- 3 TO 10 Floors = 26 days + (3
days per floor x No. of Floors)
- 11 to 50 Floors = 26 days + ( 4
days per floor x No. of Floors)
- (6 manpower inside the Shaft
Maximum)
1.0 The building transportation standards and
guidelines, NEII – 1 recommends that the room of
space temperature be maintained between 13°C and
32°C, 55°F and 90°F and with relative humidity not to
exceed to 80%.

2.0 Minimum Machine Room headroom clearance


shall be 2,400 mm.

3.0 Allowable Deviation of Hoistway clearance is +25


mm to + 50 mm
MACHINE ROOM LESS
ELEVATOR (up to 80 to 100 meters
bldg height only)
Other types of Elevators
HOSPITAL BED ELEVATOR (750 kgs, AUOTOMOBILE ELEVATORS
1000 Kgs and 1,600 Kgs (2,000 Kgs and 2,500 Kgs)
FIREMAN’S LIFT (Occupant
Evacuation Elevator)
• NFPA 5000 = 2 Fireman’s Lift
• 1 Fireman’s Lift = 900 sq. meter biggest
floor area
• 2 Fireman’s Lift = 901 to 2,000 sq. meter
biggest floor area
• Greater than 2,000 sq. meter 2 + 1 for
every 1,500 sq. meter thereof
• Maximum distance to any part of the floor
is 60 meters. Ordinary Passenger Elevator
is 45 meters.
• Hydrants 65 mm dia. near lift
Double
Deck
Traction
Elevator Sheave

Aero Dynamic
max. 2 x 2,500kg Capsule
(420m/min↑)
Main
Rope
max. 600m/min Floor
Adjustable
Motor

max. 600m
Counter
Weight Upper
Car
Car
Based on EN81-20/50 Frame

Lower
Car

Special Safety
(540m/min ↑)
Double Deck
Applicable buildings
Elevator
• Buildings with at least 2 Main entrances

• Big office buildings with lots of traffic

• Buildings that require to increase traffic and space

saving
DSS

• Buildings with minimized machine room

No.1 HDEL. GO GLOBAL! 35


Floor
Adjustable
Double
Deck
Saving
Elevator

Adjustable
2.5 ~ 7.0 m
World Best Practice
Application Handling
Capacity Rate
Double-deck Exclusive 1.8
elevator mode
Free mode 1.3

Single-deck elevator 1.0


No.1 HDEL. GO GLOBAL!
DUMBWAITER (50 Kg,75 kg, 100 kg, 200 kg & 500 kgs)

Freight Elevator (750 kg, 1000 kg to 5000 kg)

one (1) Freight Elevator = 28,000 Sq Meter

(Speeds 0.30 to 1.75 Meter per seconds)


SAMPLE OF SUPPLIERS SPEED (Hitachi)
Speed = Number of Floors /10 = Meter per Second
20 Floors/10 = 2.0 Meter per Second
CAR SPEEDS
Recommendations based on Building Height @ 0.20 Square Meter per Person Car Size

ELEVATOR CAR CAPACITY MINIMUM CAR SPEED CAR TRAVEL


USAGE

NO. OF METER / FEET / MINUTE


KGS LBS METERS FEET
PERSONS SECOND

• OFFICE BUILDING 1.8 – 2.0 350 – 400 38 0 – 125


- SMALL 1150 17 2500 2.55 – 3.00 500 – 680 39-68 126 – 225
- MEDIUM 1350 20 3000 3.6 700 69-84 226 - 275
- HIGH 1600 24 3500 4.0 800 85-115 276 - 375
5.10 1000 ABOVE 116 ABOVE 375

• HOSPITALS 0.765 150 18 60


1.0 200 19 – 31 61 – 100
1600 24 3500 1.3 – 1.53 250 – 300 32 – 39 101 – 125
1800 26 4000 1.8 – 2.0 350 – 400 39 – 54 126 – 175
2,000 28 2.55 – 3.0 500 – 600 55 – 77 176 – 250
3.6 700 78 ABOVE 250

• HOTELS 1,150 18 2500


AS OFFICE BUILDING
1,350 20 3000

• APARTMENT HOUSE 0.51 100 31 0 – 75


900 12 2000 1.02 200 32 – 45 76 – 125
1,150 17 2500 1.3 – 1.53 250 – 300 46 – 60 126 – 200
1.8 – 2.04 350 – 400 ABOVE 61 M ABOVE 200
2.0 CRITERIA FOR ELEVATOR SERVICE QUALITY

2.01 Interval or Lobby dispatch time


* Office 15 to 18 seconds
❑ PASSENGER ELEVATOR SELECTION
(22 seconds still good; 26 seconds borderline)
* Riders will not be conscious of any irksome
1. PME Code 2012 (p. 533)
delay in Elevator Service
2.02 SUGGESTED ELEVATOR INTERVALS
* 5 Floors / One Elevator
OFFICE BLDG. = 25 TO 30 Seconds
* 220 Persons / One Elevator (250 to 300)
HOTEL = 40 TO 60 Seconds
* Floor Area Divided by 9.3 M2 DORMITORIES = 60 TO 80 Seconds
Equals number of persons RESIDENTIAL
* Basis of Elevator Capacities on a * LOW INCOME = 80 TO 120 Seconds
five (5) minute rush method * MIDDLE INCOME = 60 TO 80 Seconds
- APARTMENTS = 8 TO 10% * PRESTIGE = 50 TO 70 Seconds
- OFFICE = 10 TO 13%
- COMMERCIAL = 13% TO 15%
* Glass shaft ANSI Z97.1 (p. 556)
* No pipes, Ducts to penetrate Elevator Shaft
and Machine Rooms
(Section 2510.2 p. 560 PME Code)
* POPULATION OF TYPICAL BUILDINGS FOR ESTIMATING ELEVATOR
REQUIREMENTS

NET AREA
SQ.M SQ.FT
OFFICE BLDG
PERSON PERSON

DIVERSIFIED
Single Purpose 10.80 120
Average uses 11.70 130
Upper Floors 10.8 – 17.05 120 – 145
Large Lower Floors 9.90 – 10.8 110 – 120

HOTELS PERSONS PER SLEEPING ROOM


Normal use 1.3
Conventions 1.9

HOSPITALS VISITORS PER BED


General Private 1.5
General Public 3-4
ELEVATOR CAR ACCESSORIES
VVVF = Variable Voltage
Variable Frequenecy
ASME 17.1/CSA B44 HANDBOOK
2016 Edition
EXQUISITE ENHANCED
DESIGN SAFETY
ESCALATOR
HY UNDAI ’ S E S CAL ATO RS O F F E R A NE W DI M
E NS I O N O F S AF E T Y, E F F I CI E NC Y, AND RI DE
Q UAL I T Y AND ARE E Q UI P P E D F O R
BO T H I NDO O R AND O UT DO O R US E .

The escalators of Hyundai Elevator connect severed


areas, transforming them into an open and mutual
spaces in a building. With a single drive station installed
at the top of the truss, the S-Series allows for a smooth
and compact design that maximizes space efficiency.

Vertical Height: 2m – 22m Inclination: 30


/ 35 degrees Use: Commercial Buildings &
Public Facilities

AUTOMATIC OPERATION DIRECTION


SYSTEM INDICATOR
30 degrees / 35 degrees

30 mpm (0.50 m/s) / 40 mpm (0.65 m/s)

0.40 meter depth / 0.20 meter rise step

3.0 Meter to 6.90 Meters; above 6.0 meters


intermediate support needed
Landing Space 1.8 to 2.40 meters (0.50 m/s);
3.0 to 3.60 metere (0.40 m/s)
0.80 meter width = 1 ¼ person per step
1.20 meter = 2 persons per step
EXQUISITE FLEXIBLE
LOOK DESIGN
MOVING WALK
HY UNDAI ’ S M O V I NG WAL KS O F F E R A NE W DI
M E NS I O N O F CO NV E NI E NCE,
S AT I S FACTI ON, AND E X CI T E M E NT F O R PA
SSEN G ER S.

Hyundai moving walks are available in horizontal,


inclined design within 12 degrees or in combined
design are widely applicable to various buildings and
facilities such as supermarkets, subways, department
stores, and railroad stations.

Vertical Height: 9m / 100m Inclination:


12 / 0 degrees Use: Commercial
Buildings & Public Facilities

FAILURE & OPERATION


MULTI- POST
DATA DISPLAY UNIT
MOVING WALK 0 TO 5 Degrees/moving ramp 12 Degrees up to 15 degrees