Vibration Analysis & Diagnostic studies
VIBRATION ANALYSIS
REPORT
I. INDEX 02
II. SERVICES 03
III. VIBRATION STANDARDS 04
IV. SUMMARY REPORT 05
V. REPORT 06-07
VI. SPECTRUMS 08-13
1. VIBRATION ANALYZER
Hardware : ROZH-VIBRATION ANALYZER
Vibration analysis
Laser Alignment
Infrared Thermography
Training Programs
Alert 4.5mm/s-11.2mm/s
Alarm <11.2mm/s
Power 135 KW
As per ISO standards 10816 present vibration readings recorded at motor & fan both bearings are in
alarm condition (70% load condition).
Synchronous frequency of 10.5Hz (1X motor RPM) was observed at motor & fans both bearings.
Phase analysis has been carried out & 180 0 out of phase was observed in axial direction at fan both
bearings.
Cracks were observed at machine foundation base frame.
RECOMMENDATION:
Proper welding to be done at foundation base frame where ever cracks was observed & ensure proper
tightness at machine base frame fixing locations.
Inspect the vibro pads condition & if required replace the same on priority & ensure master leveling.
Phase analysis reveals 1800 out of phase indicative of bearing skewness at fan both bearings. Hence, it
is suggested to inspect the fan both bearings for fit tolerances & bearing internal clearances.
Precision alignment to be achieved between motor to fan.
Re-assess the health condition of equipment after above correction. & for determining further course
of analysis & action plan.
NOTE:
Immediate actions are required at present condition to avoid further deterioration of the equipment.