You are on page 1of 2

UENR6333

November 2014

PBCB / WH1 / AH1 / CPH1


132
2
WS1 PAA1
M7 M8 AUXILIARY
(6A) (16A) A.C.
131
1 SUPPLY
133 131 134 87
A

C
LCL
AUDIBLE
ALARM
B

134
4 7

B C A C3.3, C4.4 and C7.1 Generator Set


Electrical System
ALTER- PANEL 5 LCL +
NATOR ENGINE C3.3: C4.4: C7.1:
131 HEATER HEATER HEATER
3 GT21-UP GT61-UP GTP1-UP
EC31-UP EC71-UP ECW1-UP
GT31-UP EC81-UP
4 5 EC41-UP GT81-UP
131
133

GT41-UP EC91-UP
E

EC51-UP GT91-UP
GT51-UP ECL1-UP
1

7
EC61-UP GTH1-UP
BATTERY BATTERY
CHARGER CHARGER 7 PANEL TERMINAL
AC DC 1 CUSTOMER AC TERMINAL
CONN CONN 1 CUSTOMER DC TERMINAL
1
DC CONNECTOR TERMINAL

© 2014 Caterpillar, All Rights Reserved Printed in U.S.A.

BATTERY
CHARGER
PAC1 or PGR1 PSV1 PSS1 FLSR PP01 PSB5
SPARE ANALOG L4
INPUT 17
7 88 90 L5
X1 1 2 3 SPEED SA1 7 5
1 4 2 1 3 L6
ST1 ADJUST
(RAISE)
VT1
3 N1
:10 :10 ST4 VT2 7
K1 K2 OFF SA1 7 5 EMER
E
:2 :2
VOLTS 2 STOP
ST2

(Dimensions: 39 inches x 28 inches)


AVR ADJUST (LOWER) (WITH
4 10K 10K B C D A 23 * :95
5 0.25W 0.25W 12 FIT PPO1 SECURITY
IF KEY)
FUEL FL
5 SY REQUIRED
X2 X3 LEVEL 6
1 2 3 4 5 6 SENSOR

UENR6333
* NOTE:FOR MCBs CONNECT 23 TO :96 SY
RR R\Fc:M RR R\Fc:UNNING
CONTACT
17A

PPE1 PPE2

CORE BALANCE CORE BALANCE


C.T. C.T.

L1 L4 L1 L4

30 Page,
L2 L5 L2 L5
G L3 L6 G L3 L6

N1 N1 N1 N1

EARTH LEAKAGE
EARTH FAULT
NEUTRAL
NEUTRAL
LINK
LINK
E E E E

EF1 EF2 EF1 EF2 7 7 :C1


5 7 7 :C1 5
ST ST
ST ST :C2
11 ST ST :C2 11
5 5
6 6

5 ST 5 ST
8 9 10 11 12 13 14 8 9 10 11 12 13 14
EARTH EARTH FAULT
LEAKAGE RELAY
RELAY

1 2 3 4 5 6 7 1 2 3 4 5 6 7
53A 5 53A 5

53A 53A
4 4
8 7 6 5 4 3 2 1

AVR 3 AVR 3
110V L1 P1 P2 L4 110V L1 P1 P2 L4
2 T1 T4 2 T1 T4
0V S1 S2 0V L2 S1 S2 110V
5 P1 P2 220V 5 P1 P2 L5 220V
E+ (OR F+) E+ (OR F+)
G G S1 S2 110V
6 L3 S1 S2 P1 P2 L6 E- (OR F-) 6 L3 P1 L6
E- (OR F-) P2

S1 S2 S1 S2

E E E E
F F
BASE BASE
4 5 6 1 2 3 U V N 4 5 6 1 2 3 U V N
NOTE: WIRE W (CONNECTED TO 102) IS NOTE: WIRE W (CONNECTED TO 102)
PANEL BODY REMOVED. PANEL BODY IS REMOVED
4 3 2 1 4 3 2 1
PANEL DOOR PANEL
DOOR
REF REF
F05 E07
4 5 6 1 2 3 4 5 6 1 2 3
REF 104 103 102 101 REF 104 103 102 101
E07 C10 C30 C50 C90 C90 C90 F05 C10 C30 C50 C90 C90 C90

M4 M5 M6 M4 M5 M6
(2A) (2A) (2A) (2A) (2A) (2A)
108 109 110 101 108 109 110 101
REF REF
G07 G07

C10 C30 C50 C90 108 109 110 101 C10 C30 C50 C90 108 109 110 101

31 47 57 39 13 11 9 7 31 47 57 39 13 11 9 7
IA IB IC RETURN VA VB VC NEUTRAL IA IB IC RETURN VA VB VC NEUTRAL

CURRENT VOLTAGE CURRENT VOLTAGE


SENSING SENSING SENSING SENSING

E E
1 PHASE 2 WIRE GEN 1 PHASE 3 WIRE GEN
PANEL WIRING 3 PHASE 4 WIRE
AVR 110V 3
L1 P1 P2 L4 L1 L4
2 T8 T11
0V S1 S2
L2 P1 P2 L5 L2 L5
5
E+ (OR F+) G
6 L3 S1 S2 P1 P2 L6 L3 L6
E- (OR F-)
N S1 S2 N N N1

E E E E
NOTE: IF 4 POLE
BASE CIRCUIT BREAKER FITTED
4 5 6 1 2 3 U V W N
PANEL BODY C10 C30 C50 C90 C90 C90
4 3 2 1
PANEL DOOR

REF
E07
D REF 104 103 102 101
D
REF
G05 G07

M4 M5 M6
(2A) (2A) (2A)
108 109 110 101

C10 C30 C50 C90 108 109 110 101

31 47 57 39 13 11 9 7
IA IB IC RETURN VA VB VC NEUTRAL

CURRENT
SENSING
VOLTAGE
SENSING
EMCP 4.1 / 4.2
(Dimensions: 39 inches x 28 inches)

O/P 1 I/P A I/P B I/P I/P I/P 3 I/P 4 I/P I/P


UENR6333

RLY1 RLY2 RLY3 RLY4 RLY5 RLY6 RLY7 RLY8 CAN2 MODBUS
C POWER ENG FUEL START AUDIBLE COMMON GEN SPARE SPARE SPARE
CAN1 1 2 5 6 5V OIL COOLANT FUEL EARTH MAGNETIC C
J1939 RS485 EMERG REMOTE LOW SPARE SPARE EARTH O/LOAD SPARE RETURN
0-32VDC CRANK CONTROL AID ALARM ALARM RUN J1939 SUPPLY PRESS. TEMP LEVEL PICKUP
(EMCP4.2 ONLY) (EMCP4.2 ONLY) STOP START COOLANT FAULT S/D OR OIL
S/D LEVEL S/D
GND - + GND + - GND + - GND + - S/D
TEMP GND + -
60 52 51 61 48 58 35 43 33 41 32 40 26 27 2 25 15 1 24 14 68 42 50 34 63 62 64 4 5 3 70 55 54 53 45 44 36 28 16 56 38 30 29 37 46 65 66 67

REF 5 7 4 17 3 17 10 17 87 5 88 5 90 5 61 62 63 64 65 66 17 24 LCL SP1 SP2 SP3 SP4 SP5 5V OP ET SA1 30 30 30 41 42


G07

8 9 10 11 12 13
17 18 19 20 21 22
:85 :85 :85
120 120
REF ECR FCR SAR OHM OHM
D05,D01 :86 :86 :86 6
14 PANEL 7
D04 REF REF
E-STOP 5 D07 E07
REF 7 7 7 7 7 7 61
5 15
D05,D01 120
D04 M3 7 88 90 62 OHM 17A
16 SA1 7 5
(6A) SERVICE
M2 1 2 3 CANOPY 4 2 1 3
30 Page,

M1 CONN 1 1
(25A) (16A) E-STOP
61 G
51 + 53 PAC1 & PGR1 17D SPARE ANALOG
VFC CONN FIT INPUT
:30 :30 :30 62 F 2 2
ECR/1 SAR/1 FCR/1 SPEED ADJUST IF
:87 :87 :87 CONN REQUIRED
51R REF 7 A
B 7W 1A 1 2 3 4 D07 5
B
1 2 3
REF 5 B
E07 REF
4 ST1 ST2 7 5
5 51A 58 19 53A 7 61 62 E07 LCL 5V OP ET 30 41 42
REF REF
D07 E07

1 10 9 23 3 12 13 18 19 20 15 22 28 33 37 34 35 36

5 + 51A 58 19 53A ST1 ST2 5V OP ET 30 41 42

GLOW MPU
PLUG REF
C07
56 57 ET

+ LCL 5 5V OP ET
53A 53A 53A 53A ST1 ST2 56 57 41 42
+ 51A + 1
MPU
REF
C03 3
A C B OP
SS
+ 19
E 2
1
12V
M 1 4 10 3 11 LOW COOLANT NOTE A: FOR USE WITH 1103/1104 ENGINE
7 PANEL TERMINAL FCS FLPS CSA LEVEL CONN ONLY
NOTE B: FOR USE WITH 1103C ENGINE
A 1 CUSTOMER AC TERMINAL ONLY A
2 ELECTRONIC GOVERNOR
1 CUSTOMER DC TERMINAL 5
1
DC CONNECTOR TERMINAL
NOTE B THIS SCHEMATIC IS FOR THE C3.3, C4.4 AND C7.1 GENERATOR SET ELECTRICAL SYSTEM
5 NOTE A 5 5 5 5 MEDIA NUMBER: UENR6333
3 PHASE 4 WIRE SCHEMATIC PART NUMBER: 451-5447, CHANGE: 01, VERSION: DK
1 PHASE 2 WIRE SCHEMATIC PART NUMBER: 451-5449, CHANGE: 01, VERSION: DK
1 PHASE 3 WIRE SCHEMATIC PART NUMBER: 451-5450, CHANGE: 01, VERSION: DK

ENGINE WIRING
OPTIONS SCHEMATIC PART NUMBER: 451-5451, CHANGE: 01, VERSION: DK
Components are shown installed on a fully operable generator set in a non powered state.
Refer to the appropriate Service Manual for Troubleshooting, Specifications and Systems Operations.
Refer to the Parts Manual using a specific serial number prefix in SIS before ordering parts from this schematic.

8 7 6 5 4 3 2 1