Thank you for purchasing a rotary flow meter of our make this time. This instruction manual explains
various cautions necessary for operation of this flow meter. The user is kindly requested to read
through this manual so that this flow meter may be used correctly and in safety for a long period of time
to his satisfaction.
For any inquiry about this flow meter or order of spare parts, please let us know the type and the serial
No. indicated on the nameplate without fail.
1.Outline
Rotary flow meter is a rotary piston type flow meter for liquid of simple construction. It uses ceramic as standard material for the
bearing in the liquid end has adopted a special resin with excellent chemical resistance, wear resistance, heat resistance and impact
resistance for the rotor. In addition, it also adopted a large register easy to read for the counting unit.
2.Type symbols
RS
Flange shape
Volume Symbol
Flange standard
Material symbol
Type of generator
Counter symbol
specifications
Supplementary
Nominal size
symbol
Rotary flow meter
A0 Volume small ● ● ● ●
Volume symbol
B0 Volume large ● ● ● ●
FC: Cast iron casting, CAC: Bronze casting, SCS14: Stainless steel casting; PPS: Special resin; GC: Carbon; AC: Corrosion-resistant aluminum
12 Without pulse output ● ● ● ● ● ● ● ●
Type of generator and pulse unit R7 Reed switch (contact) pulse 1m3/p × × × × (○) (○) (○) (○)
F FF flange ● ○ ○ ○ ○ ○ ○ ○
Flange shape
R RF flange ○ ● ● ● ● ● ● ●
Note) No explosion proof type is available in the photoelectric pulse generator type.
-2-
3. Installation procedure
1.Precautions on place of installation
Select a place satisfying the following conditions for installing this flow meter:
(1)Place subject to little vibrations.
(2)Place protected against rain and dew.
(3)Place with little dust.
(4)Place with little moisture.
(5)Place with little corrosive gas.
(6)Place not subject to any violent fluid pulsations.
(7)Place with little electromagnetic noise.
(8)Place easy to inspect.
(9)Place protected against direct sunshine.
(10)Batch pumps such as plunger type, diaphragm type, etc. are liable to produce pulsations in the fluid,
eventually leading to damage to rotor or instrumental error. Install an air chamber or accumulator to
eliminate pulsations completely.
4.Piping procedure
(1)Install the piping in a way not to apply any piping pressure to the flow meter.
(2)Install on the outlet side of the pump.
(3)Be sure to provide a strainer for this flow meter. The strainer shall be installed on the upstream side of the
flow meter as close to the flow meter as possible.
Clean the strainer element (net) regularly. If there is a lot of dust in the fluid, provide a supplementary
strainer of coarse mesh on the upstream side.
(4)Fit the arrow mark given on the lateral face of the flow meter to the direction of inflow of the fluid.
(5)When using the flow meter at a tank head, give a head larger than the pressure loss of the flow meter.
(6)When using a liquid packing, etc., take care to prevent the liquid packing, etc. from protruding into the pipe.
(7)Install in the specified posture.
(8)Do not wind any insulating material around the cooling fin of the flow meter equipped with cooling fins.
(9)Change of direction of dial plate
(a)loosen the dial case tightening nut or bolt.
(b)Turn the dial case by a desired angle (by 90°each time).
(c)Tighten the nut or bolt.
Dial case
Nut or Bolt
Size :M8
-3-
5.Wiring procedure
A flow meter with pulse generator shall be connected according to the instructions given on the following table:
White Brown
Red Black Black Blue
Terminal
layout
drawing
Receiver SIG +V 0V SIG +12V 0V
6.Example of installation
Vertical piping
Horizontal piping Horizontal piping
(Horizontal installation) (Vertical installation)
The mark ※ indicates a space necessary for disassembling and inspection. Install the piping in a way to secure
a dimension no small than the figures indicated on the table below.
unit:mm
025B0 040B0 050B0 080B0
Type・Size
040A0 050A0 080A0 100A0
※Dimensions 192 246 312 444
-4-
4.Functions & operating method
1. Indicating function
RSA0 type・・・・・The pointer turns clockwise according to the measured flow rate, to count the
(Pointer type) integrated value.
RSZ8 type・・・ The indication of the zero-reset counter and the total counter increase according to the
(Digital zero-reset type) measured flow rate.
・To reset the zero-reset counter to “0000”, turn the knob on the right side of the
counter anti-clockwize.
Note) The counter turns only in the direction of larger figures. Take care to avoid
any excessive turning.
Counter equipped with resetting
Symbol of Continuous total counter
Symbol of device
nominal Number of Minimum Maximum Number of Minimum Maximum
capacity
size figures unit capacity figures unit capacity
025 B0
4 0.1L 9,999L 7 1L 9,999,999L
A0
040
B0
4 0.1L 9,999L 7 1L 9,999,999L
A0
050
B0 9,999,999
4 1L 9,999×10L 7 10L
A0 ×10L
080
B0 9,999,999
4 1L 9,999×10L 7 10L
100 A0 ×10L
RSI0 type・・・ The measured instant flow rate can be read from the indication of the pointer.
(Instant flow rate indicator type) The indication of the total counter increase according to the measured flow rate.
Symbol of Full scale and division Total counter
nominal Symbol of
capacity Standard full Unit of Minimum Maximum
size scale division unit capacity
025 B0
5,000L/h 200L/h 0.02L 9,999,999×0.1L
A0
040
B0
12,000L/h 500L/h 0.2L 9,999,999L
A0
050
B0
24,000L/h 1,000L/h 0.2L 9,999,999L
A0
080
B0
50,000L/h 2,000L/h 2L 9,999,999×10L
100 A0
Note)230°for full-scale angle.
-5-
2.Output functions
●Reed switch pulse generator(Symbol:R)
Outputs no-voltage contact signals proportional to the flow rate.
Note) In case of shortage of contact capacity, use a relay box (of optional specifications).
2.2kΩ
L: 0.5V or under (At no-load)
SIG
-6-
5.Maintenance & inspection
Mixing of air in the liquid. Eliminate air by installing an air separator, etc.
Excessively large
totalized volume of flow
Take protective measures against penetration
meter against actual Empty piping before and after the flow meter.
of air into the piping.
liquid volume.
(Accuracy on plus side) High viscosity of operating liquid
Correct instrumental error by replacing the
(temperature, viscosity, etc. different from
correction gears.
specifications).
Excessively small
Low viscosity of operating liquid (temperature, Correct instrumental error by replacing the
totalized volume of flow
viscosity, etc. different from specifications). correction gears.
meter against actual
liquid volume. Wear or breaking of measuring unit parts. Disassemble and inspect the measuring unit
(Accuracy on minus Adhesion of dust, scale, etc. to the measuring according to the disassembling procedure of
side) unit. flow meter. Clean or replace parts.
Flow meter needs periodic maintenance and inspection to maintain measuring accuracy. Interval of inspection is basically
every year but this interval is changed depending on the frequency of use and the working environment.
It is recommended to make inspection of flow meter at our factory at least every three years.
-7-
6.Disassembling procedure
chamber cover
Lower magnet
Body
Measuring
chamber
Remove all body bolts。 Lift the lower magnet vertically and Remove the measuring chamber cover
Tool、Size separate the measuring chamber by lifting it vertically.
025B0、040A0 : Hex-head spanner(10mm)
from the main body while taking
040B0、050A0 : Spanner(24mm)
050B0、080A0 : Spanner(24mm) care not to damage the lower
080B0、100A0 : Spanner(30mm)
magnet.
Hole
Check if the rotor turns smoothly. Clean well the rotor and the Set the rotor shaft correctly in
measuring chamber sufficiently the hole for rotor shaft in the
with gasoline or water, etc. If eccentric bearing.
there is a contact between the
rotor and the partition wall when
you replaced the rotor, grind the
contact part gently with a fine
file.
Ditch
Clutch
Partition
Rotor Entrance
wall
shaft
-8-
7.Disassembly drawing
Counter unit(Type A0) 23A Counter unit(Type Z8) 23B
(including (including
20A,21A,22A) 20B,22B)
22A 22B
21A
20A 20B
※Note1 ※Note1
25
25
20C
25
(Intermediate gear)
Without
generator
31 (including 27,30)
27 (including 26)
25 26
25
15
10(including 7~10)
5
24
4
11 1
-11-
№ Parts name Q’ty № Parts name Q’ty № Parts name Q’ty
1 Measuring chamber set 1 14 Main body set (including 13) 1 22C Glass set – Type I0 1
Counter unit set – Type A0
2 Measuring chamber 1 15 Dial flange set 1 23A 1
(including 20A,21A,22A)
Non explosion-proof Counter unit set – Type Z8
3 Center axis 1 16 1 23B 1
reduction gear unit (including 20B,22B)
Non explosion-proof Counter unit set – Type I0
4 Partition wall 1 17 1 23C 1
generator case set (including 20C,21C,22C)
5 Eccentric bearing 1 18 Non explosion-proof pulse unit 1 24 Bolts for main body 8(6)
Non explosion-proof generator
6 Rotor set 1 19 1 25 Bolts for dial unit 4
set(including 16~18)
Explosion-proof reduction gear
7 Clutch 1 20A Dial set - Type A0 1 26 1
unit
Measuring chamber cover
Explosion-proof reduction gear
8 (including bushing , 1 20B Dial set – Type Z8 1 27 1
set (including 26)
suppression board)
Lower magnet set
9 1 20C Dial set – Type I0 1 28 Explosion-proof pulse unit 1
(including split pin)
Measuring chamber cover set Scale plate (including pointer) Pressure-resistant packing
10 1 21A 1 29 1
(including 7~9) Type A0 type metal fixture
Explosion-proof pulse set
11 Packing for body 1 21B Scale plate – Type I0 1 30 1
(including 28,29)
Explosion-proof generator set
12 Upper magnet set 1 22A Glass set – Type A0 1 31 1
(including 27,30)
Pressure cover set
13 1 22B Glass set – Type Z8 1 32 Cooling fins set 1
(including 12)
-12-