You are on page 1of 8

PLTU Kanci I PLTU Kanci II Brebes I Brebes II Trafo I Trafo II

NO DESCRIPTION
R S T R S T R S T R S T R S T R S T
Bay Line
1 LIGHTENING ARRESTER
- Insulation Resistance Test
- Counter
- Photo nameplate/ SN
2 CURRENT TRANSFORMER VOLTAGE ( CVT ) LINE
- Insulation Resistance Test
- Ratio
- Wending Resistance
- Burden
- Grounding
- Photo Nameplate/ SN
3 DISCONNECTING SWITCH/ EARTHING
- Timing
- Insulation Resistance Test
- Contact Resistance
- Grounding
- Photo NAmePlate/ SN
4 CURRENT TRANSFORMER
- Insulation Resistance test
- Ratio OK OK OK OK OK OK OK OK OK OK OK OK
- RDC OK OK OK OK OK OK OK OK OK OK OK OK
- Knee Point OK OK OK OK OK OK OK OK OK OK OK OK
- Burden OK OK OK OK OK OK OK OK OK OK OK OK
- Grounding
- Photo NamePlate/ SN
5 CIRCUIT BREAKER
- Timing
- Open 1
- Open 2
- CO Time
- OC Time
- OCO
- Insulation Resistance Test
- Minimum Voltage Test
- SF6 Gas Analyzer
- Photo NAmePlate/ SN

6 DISCONNECTING SWITCH BUS I


- Timing
- Insulation Resistance Test
- Contact Resistance
- Grounding
- Photo NAmePlate/ SN
7 DISCONNECTING SWITCH BUS II
- Timing
- Insulation Resistance Test
- Contact Resistance
- Grounding
- Photo NAmePlate/ SN

Bay Transformer
1 LIGHTENING ARRESTER
- Insulation Resistance Test
- Counter
- Photo nameplate/ SN

2 CURRENT TRANSFORMER
- Insulation Resistance test
- Ratio OK OK OK OK OK OK
- RDC OK OK OK OK OK OK
- Knee Point OK OK OK OK OK OK
- Burden OK OK OK OK OK OK
- Grounding
- Photo NamePlate/ SN

4 CIRCUIT BREAKER
- Timing
- Open 1
- Open 2
- CO Time
- OC Time
- OCO
- Charging TIme
- Insulation Resistance Test
- Contact Resistance
- Minimum Voltage Test
- SF6 Gas Analyzer
- Photo NAmePlate/ SN
5 CURRENT TRANSFORMER
- Insulation Resistance test
- Ratio
- RDC
- Knee Point
- Burden
- Grounding
- Photo NamePlate/ SN
6 DISCONNECTING SWITCH BUS I
- Timing
- Insulation Resistance Test
- Contact Resistance
- Grounding
- Photo NAmePlate/ SN
7 DISCONNECTING SWITCH BUS II
- Timing
- Insulation Resistance Test
- Contact Resistance
- Grounding
- Photo NAmePlate/ SN

Bus Coupler
1 DISCONNECTING SWITCH BUS I
- Timing
- Insulation Resistance Test
- Contact Resistance
- Grounding
- Photo NAmePlate/ SN
2 CURRENT TRANSFORMER BUS I
- Insulation Resistance test
- Ratio OK OK OK OK OK OK
- RDC OK OK OK OK OK OK
- Knee Point OK OK OK OK OK OK
- Burden OK OK OK OK OK OK
- Grounding OK OK OK OK OK OK
- Photo NamePlate/ SN
3 CIRCUIT BREAKER
- Timing
- Open 1
- Open 2
- CO Time
- OC Time
- OCO
- Insulation Resistance Test
- Minimum Voltage Test
- SF6 Gas Analyzer
- Photo NAmePlate/ SN
4 DISCONNECTING SWITCH BUS II
- Timing
- Insulation Resistance Test
- Contact Resistance
- Grounding
- Photo NAmePlate/ SN
5 CURRENT TRANSFORMER BUS II
- Insulation Resistance test
- Ratio OK OK OK OK OK OK
- RDC OK OK OK OK OK OK
- Knee Point OK OK OK OK OK OK
- Burden OK OK OK OK OK OK
- Grounding
- Photo NamePlate/ SN
NO DESCRIPTION
1
Incoming Bus Section Outgoing 2
NO DESCRIPTION
R S T R S T R S T
MV
2 CURRENT VOLTAGE TRANSFORMER ( CVT )
- Insulation Resistance Test
- Ratio
- Wending Resistance
- Burden
- Grounding
- Photo Nameplate/ SN
3 EARTHING SWITCH
- Timing
- Insulation Resistance Test
- Contact Resistance
- Grounding
- Photo NAmePlate/ SN
4 CURRENT TRANSFORMER
- Insulation Resistance test
- Ratio OK OK OK OK OK OK OK OK OK
- RDC OK OK OK OK OK OK OK OK OK
- Knee Point OK OK OK OK OK OK OK OK OK
- Burden OK OK OK OK OK OK OK OK OK
- Grounding
- Photo NamePlate/ SN
5 CIRCUIT BREAKER
- Timing
- Open 1
- Open 2
- CO Time
- OC Time
- OCO
- Insulation Resistance Test
- Minimum Voltage Test
- Photo NAmePlate/ SN

6 HV Test Cable (R-S-T-N) Trafo - Incoming Bus Section - Bus Riser


- Insulation Resistance Test
Before Dielectric Test (semua kabel)
After Dielectric Test (semua Kabel)

- High Voltege Test Cable


Duration 15 m, 48 KVDC

7 KWH
8 Relay
- Download Setting Relay (refer to Data Setting PLN)
- Individual test Relay
Outgoing 3 Outgoing 1 Outgoing 4
R S T R S T R S T

OK OK OK OK OK OK OK OK OK
OK OK OK OK OK OK OK OK OK
OK OK OK OK OK OK OK OK OK
OK OK OK OK OK OK OK OK OK