You are on page 1of 1

88

FORMAT NO QA/SF/042
SULZER FIELD INSPECTION REPORT DATE 24-Apr-24
REPORT NO RIS-AM-116
CUSTOMER OFFSHORE FRONTIER SOLUTIONS PTE LTD ITEM DESCRIPTION BASE PLATE INSPECTOR NAME ANSAR MULLA
SUPPLIER JAMPOW FABRICATORS, KARAD PUMP MODEL BBS- sc 12X16X31J-1 MFS 450 MOC:- As per PO
PO NO 4502137927 LN NO 10; 20 PROD ORDER NO - TEMP DURING INSP 34°C
CASTING DRG NO REV -- WBS NO / SO NO Q/0100509664-0050-12 [LN 10] OFFERING
Raw Mtrl.
Q/0100525054-0060-12 [LN 20] STATUS Fully
Stage Pre M/ced
M/ced
M/C ING DRG NO 3-204423925 REV A CONNECTION - Inspection
QTY ORD SHIPPED OFFERED ACCEPTED REWORK REJECTED INSP DATE
1+1 - 1+1 0 24-Apr-24
QTY QTY QTY QTY QTY
REWORK POINTS (Visual, NDTand Dimension) 1st Offer 2nd Offer 3rd Offer
Note: This base plate offer for stage inspection of Load Test & NDT

CONCESSION REQUEST(Visual, NDTand Dimension) 1st Offer 2nd Offer 3rd Offer

GENERAL/VISUAL COMMENTS (Visual, NDTand Dimension &if any) 1st Offer 2nd Offer 3rd Offer
1. Load test witnessed done & found satisfactory of base plate Acc
2. UT & MT certificate & Other Document Reviewed and found acc Acc
3. NDT- UT on lug weld joint accessible area Witnessed found satisfactroy Acc
4. NDT - MP Test on Lug Weld Joint witnessed found satisfactroy Acc
5. Dimension will be checked after final machining of base plate Balance
6. Visual on welds will be check after final blasting & painting. Balance
HEAT No JOB NO- 24 JF SPI BP 007, 008

SUPPLIER QA SULZER QA