You are on page 1of 1

FORMATE NO: RIS/SIR/010-REV.

01
RIKSONS CUSTOMER / SUPPLIER DATE : 8-Mar-24
INSPECTION
SERVICES INSPECTION REPORT INSPECTOR NAME: ANSAR MULLA
REPORT NO: AM-127
CUSTOMER: AR Wilfely India Pvt Ltd
SUPPLIER : The Sky Industries, Tilawni-Kolhapur
HEAT No.: PART NO- TSI/WILFELY/23/BF/42 & 43 FEB
PART DETAILS : Base Frame DRG. NO: ZBPA7258-200ML REV.00
PO NO / LINE : 2224/SKY/1 LN 5 GRADE : MS
OFFER INSPECTED ACCEPTED REWORK REJECT
PO QTY. REASON FOR REWORK / REJECTION
QTY QTY. QTY. QTY. QTY.
2 2 2 - 2 - Dimensional; Welding size rework

Inspection Summery / details as below,


# Rework Points / General Comments / Visual Rework Point :- REMARK
1. Depth 54 [-1.0] is observed as 1) 52.26/52.73 ; 2) 52.62/ 53.00 Rework
2. Fillet Weld- leg size 10 mm required actual observed 6-7 mm at found pump & motar base pad Rework
3. Documents Reviewed - MTC Balance
4. Visually Checked & found satisfactory Acc
5. GD & T not offered during Inspection FYI
6. After welding leg rework , Re-check again rework related area of dimension Re-check

# DEVIATION POINTS / CONCESSION REQUEST:- REMARK

NIL

TICK AS ''√ '' > √


FINAL INSPECTION REMARKS :
UNDER REWORK UNDER DEVIATION CLEARED FOR DISPATCH