You are on page 1of 1

CO CO

S1
15-Watts LB
15-Watts LB
ELECTRICAL GENERAL NOTES
C1 ALL ELECTRICAL WORKS AND INSTALLATIONS HEREIN SHALL BE EXECUTED IN ACCORDANCE WITH THE LATEST
S2 CO CO APPROVED EDITION OF THE PHILLIPINE ELECTRICAL CODE (PEC), RULES AND REGULATIONS
OF THE LOACAL AND NATIONAL AUTHORITIES CONCERNED IN THE IMPLEMENTATION OF ELECTRICAL
15-Watts LB 15-Watts LB
LAWS AND ORDINACES AND THE LOCAL POWER UTILITY AND TELEPHONE COMPANIES.

S2
WORMASHIP SHALL BE EQUAL TO THE BEST STANDARD PRACTICE RECOGNIZED AND ADOPTED FOR THIS
TRADE. ONLY EXPERIENCED MEN UNDER THE DIRECT SUPERVISION OF A DULY LICENSED
15-Watts LB 15-Watts LB
ELECTRICAL ENGINEER SHALL EXECUTE ALL ELECTRICAL WORKS HEREIN INCLUDE. WORKS HERIN INCLUDE. WOKS SHALL
BE NEATLY PLACED, SECURELY FASTENED AND PROPERLY FINISHD.

15-Watts LB 15-Watts LB ALL MATERIALS USED SHALL BE NEW AND APPROVED FOR BOTH PURPOSE AND LOACTION INTENDED.

S2 ALL WIRES TYPE TW / THW SHAL BE INSULATED FOR 600 VOLTS AND SHALL BE INSIDE RIGID
CO uPVC PIPES. ELECTRICAL TRADE SIZES WERE USED (A MINIMUM OF 15mm DIAMETER FOR
CO
15-Watts LB 15-Watts LB CONDUITS AND 3.5mm sq FOR CIRCUITS RUNS). ALL CIRCUIT BREAKERS SHALL BE BOLT-ON
S1
NO BRANCH CIRCUIT SHALL BE HAVE A LOAD OF MORE THAN 80% OF ITS RATING.
ELECTRICAL SERVICE REQUIREMENTS SHALL BE 220 VOLTS, 1-PHASE, 60 HERTZ.
YPE AND INSIDE FACTORY STANDARD ENCLOSURES.

POWER LAYOUT
LIGHTING LAYOUT
FLOOR PLAN
FLOOR PLAN SCALE 1:100M
SCALE 1:100M

TO POWER SOURCE
220V, 2P, 60 HERTZ

M PB1 SCHEDULE OF LOADS


1 - # 8.0mm² TW QUANTITY POWER SWITCH CIRCUIT
1 - # 2.0 mm² THHN PB CKT. NO. (WATTS) CURRENT VOLTS
BREAKER PHASE CONDUIT SIZE WIRE SIZE
DESCRIPTION LIGHT CO OTHERS S1 S2 S3 3WAY
30AT, 2P
220 V 1 15-Watts PINLIGHT 10 150 0.68 2 3 220 10 20mm Ø PVC PIPE 2 - 3.5mm² THHN WIRE
2 CO 6 1200 5.45 220 10 20mm Ø PVC PIPE 2 - 3.5mm² THHN WIRE

10AT, 2P 10AT, 2P
1 2

TOTAL 1,350 6.14 220 30 AT 2P 32mm Ø PVC PIPE

Ic = [ ( 0.25 x 12.0) + (6.14)] (0.80) Ip = [ ( 2.00 x 12.0) + (6.14)] (0.80)


= 7.312 Amperes = 24.112 Amperes
SINGLE LINE DIAGRAM use 2- 8.0mm sq. THW wire + 1 - 2.0mm sq. THW wire 32mm Ø PVC Pipe use 30AT 2P 100AF 10KAIC 220V bolt-on type MCCB

DESIGNED BY: THIS DRAWING IS ISSUED FOR:


FROM THE OFFICE OF: PRC. NO. : 1518 SEAL PROJECT TITLE PROJECT OWNER: SHEET CONTENTS: AS BUILT ESTIMATE SHEET NO.

DRAFTED BY: BIDDING FABRICATION


VALIDITY : 04/24/2021
PROPOSED ONE-STOREY BUILDING PERMIT OWNER'S APPROVAL

PTR. NO. : 21399539 LIGHTING LAY-OUT


DATE:
CONSTRUCTION PRESENTATION E
OFELIO T. MIPARANUM RESIDENTIAL HOUSE NARCISO IRENEO B. GEORSUA POWER LAY-OUT
DATE : 03/19/19
SCHEDULE OF LOADS
IMPORTANT : MEASUREMENTS ARE VERIFIED ON SITE AND ALL DISCREPANCIES
SHOULD BE REPORTED TO THE ARCHITECT. 1 1
THIS DRAWING ACTING AS INSTRUMENT OF SERVICE IS THE INTELLECTUAL PROPERTY
ADDRESS : PANDACAN, PINAMUNGAJAN, CEBU T.I.N. : 104-186-880-000 LOCATION: BRGY. POBLACION, ALOGUINSAN, CEBU ADDRESS : BRGY. POBLACION, ALOGUINSAN, CEBU OF THE ARCHITECT & CANNOT BE REPRODUCED WITHOUT THEIR WRITTEN CONSENT.