By Pass
S
Output
P/N 2364241 Power 27675A AC IN / TB1 (1-2) L BUS BAR 27508A G Control Booth Live Monitor
STRIP UPS 27702
P
27694 P 27513A DET. POWER MAINS J1
16A
strip box V 27492A VIDEO IN
AWG10 AWG12
2315513
AWG10 AWG12
27550 27549
Opto-
Handswitch
H PDU & BUS BAR
Bridge 28254A S
LC Gantry S 27676A
H
J6 J2B Signals and 24Vdc
C1-
C1-CABINET G 28261A BUS BAR J5 Not Used J8 Not Used
27586A DETECTOR
Non UPS UPS
2350103 P 27586A Detector Supply L BUS BAR 27470A G
G 27468 BUS BAR
DL Keypad
AWG10
AWG10
AWG10
20A
J4A UPS Downscan supply 27684A P S 27512A Optic fiber L BUS BAR 27471A
w/ bulkhead
G BUS BAR from PDB
27722A S 27494A Serial Link with Power
J3A Detector AC 27513A P Detector water
Positioner power supply W 27511A
pipe in flow
C2 power 3 Phases SERVICE PWS J15
(Not for US) Detector water L BUS BAR 27030 G
C2-
C2-CABINET BUS BAR 27468A G 27510A
pipe out flow
27680A 2 Phase PDU
See Connecting Details * 27473A FE Laptop
BUS BAR
P TB02 3 Phase 400V CB1 TUBE
[
* Connecting Details X-Ray tube water S 27505A NO BULKHEAD (Free)
(For US only) J4B UPS/J2A Strip AC
27472A P G W 27666A
pipe out flow GND 27030 G
BUS BAR
S 27561A Emergency UPS Stop J17
Control Booth Power Strip 27667A X-Ray tube water
pipe in flow
[
Remote Box . Option
G 27681A BUS BAR J9 Strip AC P G
BUS BAR 27582A H 27589A ANODE I+
J TB02
3x 160A 3Ph to C2
Ceiling Power
27590A CATHODE I- P S 27452A J1
ECG Control Unit (Optional) J
AWG6 J1A 3rd MON OPTION BUS BAR 27501A P G
S S 27560A Data Reserved
2347573
AWG6
S 27686A 27664A X-ray tube stator cde J1
Jedi 27686A PDU ON/OFF J20
AWG6
J1B 4th MON OPTION BUS BAR 27502A P G 27665A X-ray tube temp status
V 27555A Red Video Reserved
FUSE BOX
P 27522A
Detector Conditioner Power J3B
V 27556A Green Video Reserved
G
PDB
P/N 2364241
27663A X-Ray tube ingrid 27508A
V 27557A Blue Video Reserved
16A
P 27669A J100 Power
AWG10 AWG12 motor V 27558A H SYNC Video Reserved
2315513
2358531
AWG10 AWG12
Detector Conditioner S 27670A J206 Collimator
V 27559A V SYNC Video Reserved
PDB
AWG10
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
** Connecting Details TECHNICAL ROOM
C2 Electronics Cabinet (positioner) NOTE: Cable group either 4-2, either 4-3 and 4-4 could be extended with cable group 4-1 not shown.
PDB Positioner Connection 3/4 LCD Monitor suspension
Bulkhead 3 EXAM ROOM CEILING
Room
20 BULKHEAD SYSTEM
24 m 36 m Box
Light Advantx LCA W/Bolus chasing 27083A P S
Control TB3 27682A S PDB On-Off CJ 512/1 28172 28173
DOSE DISP 2
S Dose Monitor Display 2 Legend:
21
Downscan supply CJ1 27684A P
A 14
Ground Room
Light 27686A S PDU On-Off CJ4
.
A
Switch
S W = Water Lines
(TSSC)
V VCIM console CJ712 27676A S 29183 28194
DOSE DISP 1
S Dose Monitor Display 1 = Signal Cables
15 27685A Downscan in CJ3
TB2 .
Without Fluoro UPS V
Shield 1 27678A S Downscan out CJ2 27495A V = Video Cables I = Internal Cable
12 2
X-Ray ON With Fluoro UPS RT Bus CJ301 BW 1 Location
13 3
28259A S
3 mon 28066 28067 BW-1 H = High Voltage Cables
18 Shield 4 Modular PDU/C2 V Live Fluoro Monitor
5
C2 power 3 Phases
from PDB (For US only) 4 mon 28070 28071
34 = Cable Run Numbers
X-Ray Power ON
Lamp 6 G P Elegance power cable TB602
27660A
P 2nd shielding
P = Power Cables
3 Phase 400V and GND 27661A
19 Shield 7 SUSPENSION
GROUND
16 8 24 V 27680A G P FL2/CB4 2 wires AC
27675A P 3 / 4 mon 28189 28190 G = Ground Wires FS = Field Supplied Cables
9 power cable CB600 G
X-Ray
Lamp
C2 power 3 Phases
from C1 (Not for US)
4-4 MONITOR (Independent of
Door POWER
17 Switch 3 / 4 mon 28186 28187 P Monitor Suspen Pwr Strip Power Cables)
11198A = MIS Numbers
BULKHEAD TABLE
B BW 2 Location B
27683A S Debug J18 3 mon 28068 28069 BW-2
V Roadmap Monitor
100 wires signal table data #1 BJ400 27672A S 4 mon 28072 28073
27679A S Ge Bus / Arcnet DJ23
*27673A - Not used for 2nd shielding or = Not included in GTC
100 wires signal table data #2 BJ201 27673A*
IQ
Innova Table BW 3 / Color 1 Location
Door Interlock TB2 See Connecting 25 wires UIF table power data BJ403 27674A P HOSPITAL 3 / 4 mon POWER ECG
28120 28121 P ECG Display Monitor OR
Details ** UPS LINE
X Ray On Light TB2
24 wires Motor power AJ200 27669A P or = Optional Selectable in GTC
ECG Control 3 mon 28045 28046
Unit COLOR 1
15 wires signal cable AJ300 27670A S OR V AW Monitor OR
27681A G BOLT WARNING: Prior to AW Video
100 wires signal cable data AJ 202 Splitter 4 mon 28047 28048
Remote Access Modem Line
27671A each installation, CONTROL BOOTH
ensure that the ECG BW-3 Dose Monitor Control
DL Video
4 mon 28076 28077 V
BW3 Monitor - 4TH 29183
Local Phone Walk Plug (DIRECT) 27587A power cable is Splitter
S DISPLAY
J32 / J1B Option 28194
connected to a line that
C is protected against
nd
2 shielding
S 27126A ION CHAMBER A
C
short circuit hazards,
Fluoro UPS I/F box (Option) according to local BW 4 / Color 2 Location S 27126B ION CHAMBER B
Hospital Main Fluoro UPS (Option) With Fluoro UPS
S 28259A J2 RT-bus C2 cabinet regulations and that HOSPITAL 28120 28121
POWER ECG
P
4 mon ECG Display Monitor OR
With Fluoro UPS UPS LINE Bolus Wallbox
the ECG monitor is
Power UPS control 28257A S
With Fluoro UPS
S 28257A J3 UPS control
powered according to
ECG Control ADVANTX LCA W/BOLUS
S 28258A J4 PDB control Unit
4 mon
COLOR 2
V P S 27083A CHASING
OR 28049 28050
3 x 380 to Ethernet 28262A S With Fluoro UPS
S 28260A J1 RT-bus C1 cabinet
IEC60601-1 AW Video AW Monitor OR
requirements (leakage Splitter 27041A INNOVA W/BOLUS CHASING
S Control Booth Roadmap
480 VAC EPO/ON/OFF 28256A S
With Fluoro UPS
G 28261A Bolt current and BW-4
DL Video BW4 Monitor - 3RD Monitor
(+Neutral for Fluoro grounding). Splitter 4 mon 28074 28075 V
J28 / J1A Option V 27500A VIDEO IN
UPS Option) 2nd shielding
C1 Electronics Cabinet (system)
3 / 4 mon
28195 28196
I/R RECEIVER
S
DL Infrared
Ethernet HUBS
With Fluoro UPS
Ethernet RJ POS J5 27662A S Remote Receiver Accessories Video Peripheral
D S 28262A Ethernet (Fluoro UPS J48)
V D
Rectifier
By Pass
27495A VIDEO IN
Output
AWG6
Jedi S 27677A X-Ray Tube Chiller Control DJ4 RS232 J3 (Generic IF Board) InnovaIQ Table
(Innova 2100-IQ only) 27701
AWG6
P 27674A J605 Table Pwr Data J2 27452A P S
LVPS 400 Relay command Oil Pump
FUSE BOX Power
PDB
AWG10 AWG12
STRIP NON UPS
28245 L BUS BAR
PDU P/N 2305956-2
strip box P 27722A DET. PW OUT J3 27471A
27550 27549
AWG10
AWG10
AWG10
27722A
VCIM On-Off Console with
PDU & BUS BAR Opto-
Bridge 28254A S Handswitch
H 28261A J6 J8 J2B LC Gantry H
G BUS BAR J5 Not Used UPS Not Used S 27676A Signals and 24Vdc
C1-
C1-CABINET Non UPS 28189/ 27586A DETECTOR
SUSPENSION 28190 G
2350103 G 27468 BUS BAR P 27586A Detector Supply L BUS BAR 27470A G
J4A Downscan supply 27684A
AWG10
AWG10
AWG10
[
* Connecting Details J4B UPS/J2A Strip AC
BUS BAR 27472A P G W 27666A X-Ray tube water
GND
(For US only) pipe out flow 27030 G S 27505A NO BULKHEAD (Free)
S 27561A Emergency UPS Stop J17 Control Booth Power Strip
[
27667A X-Ray tube water Remote Box . Option
J9 Strip AC 28186/ pipe in flow
G 27681A BUS BAR BUS BAR P G
28187 H 27589A ANODE I+ P S 27452A J1
J TB02
3Ph to C2
Ceiling Power
ECG Control Unit (Optional)
J
3x 160A 27590A CATHODE I-
AWG6
S 27686A J1A 3rd MON OPTION BUS BAR
27501A P G G 27508A
27686A PDU ON/OFF J20 S S 27560A Data Reserved
2347573
P/N 2364241
27663A X-Ray tube ingrid SUSPENSION 3 mon 28045 28046
CONNECTION
BOX
16A
P 27669A J100 Power COLOR 1 4 mon 28047 28048 V VGA
AWG10 AWG12 motor
2315513
Detector Conditioner
2358531
AWG10 AWG12
S 27670A J206 Collimator
PDB
AWG10
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16